Access Management Standards

Similar documents
CHAPTER 9: VEHICULAR ACCESS CONTROL Introduction and Goals Administration Standards

Lake County Building Department

M I D - C O A S T REGIONAL PLANNING COMMISSION 166 SOUTH MAIN STREET, SUITE 201 ROCKLAND, ME (207)

800 Access Control, R/W Use Permits and Drive Design

TRAFFIC MANAGEMENT STANDARDS CITY OF GARLAND TRANSPORTATION DEPARTMENT

2. ELIGIBILITY REQUIREMENTS

CONTENTS I. INTRODUCTION... 2 II. SPEED HUMP INSTALLATION POLICY... 3 III. SPEED HUMP INSTALLATION PROCEDURE... 7 APPENDIX A... 9 APPENDIX B...

Plan Check Policies and Guidelines

DRIVEWAY ENTRANCES GENERAL. 1. Description

DIRECTIONAL DRIVEWAYS AT HIGHWAYS WITHOUT CURB

2.0 Development Driveways. Movin Out June 2017

SPEED CUSHION POLICY AND INSTALLATION PROCEDURES FOR RESIDENTIAL STREETS

CHAPTER 2 ZONING AND DEVELOPMENT

Plan Check Policies and Guidelines

CROW WING COUNTY HIGHWAY DEPARTMENT APPLICATION FOR PERMIT TO CONSTRUCT DRIVEWAY ACCESS TO ROADS UNDER COUNTY JURISDICTION CONSTRUCTION INFORMATION

ORDINANCE NO

DRIVEWAY/APPROACH PERMIT APPLICATION Applicant Type: Architect/Engineer Contractor Owner

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

MOTOR VEHICLE ORIENTED BUSINESSES.

APPENDIX C1 TRAFFIC ANALYSIS DESIGN YEAR TRAFFIC ANALYSIS

ARTICLE 8 OFF-STREET PARKING AND PRIVATE DRIVEWAY STANDARDS

Department of Planning and Land Services Development Engineering GATES PERMITTING, DESIGN & INSPECTION GUIDE

Purpose: General Provisions:

CITY OF PORTSMOUTH DEPARTMENT OF PUBLIC WORKS (DPW) DRIVEWAY RULES AND PROCEDURES

ELMORE COUNTY HIGHWAY DEPARTMENT

1. INTRODUCTION 2. PROJECT DESCRIPTION CUBES SELF-STORAGE MILL CREEK TRIP GENERATION COMPARISON

CHAPTER 140 DRIVEWAYS

LAWRENCE TRANSIT CENTER LOCATION ANALYSIS 9 TH STREET & ROCKLEDGE ROAD / 21 ST STREET & IOWA STREET LAWRENCE, KANSAS

Fire Apparatus Access Roads in Marysville

FIRE DEPARTMENT ACCESS Based on the 2012 edition of the International Fire Code

# TO: FROM: PREPARED BY: DATE: SUBJECT:

POLICIES FOR THE INSTALLATION OF SPEED HUMPS (Amended May 23, 2011)

TRAFFIC CALMING PROGRAM

CAR 10-1 TRAFFIC CALMING CAR 10-1 OPR: Engineering 06/06

TRAFFIC DEPARTMENT 404 EAST WASHINGTON BROWNSVILLE, TEXAS City of Brownsville Speed Hump Installation Policy

DRIVEWAY STANDARDS EXHIBIT A. The following definition shall replace the definition of driveway in Section 62:

GUIDELINES FOR ADVERTISING SIGNS

Traffic Impact Statement (TIS)

Community Design Standards

TRAFFIC IMPACT ANALYSIS

The Township Guide to Parking Restrictions

APPENDIX C-2. Traffic Study Supplemental Analysis Memo

The Design-Builder shall meet local road criteria provided by the local governing agencies.

Traffic Generation November 28, Mr. Todd Baker Baker Properties, LLC 953 Islington Street Suite 23D Portsmouth, NH 03801

ENGINEERING BEST PRACTICE BP2.2.1

Table of Contents INTRODUCTION... 3 PROJECT STUDY AREA Figure 1 Vicinity Map Study Area... 4 EXISTING CONDITIONS... 5 TRAFFIC OPERATIONS...

POLICY AND PROCEDURE FOR SPEED HUMP INSTALLATION. Effective Date: July 10, 2013

CHAPTER 3. Driveways (Rev. 9/04, Ord )

King Soopers #116 Thornton, Colorado

Knox County Zoning Ordinance Amendments: Section Off-street parking lot layout, construction and maintenance. 4-A-15-OA

CHAPTER 15 STREET LIGHTING TABLE OF CONTENTS

TOWN OF MARANA, ARIZONA LAND DEVELOPMENT CODE

STAFF REPORT # CHANGE OF ZONING

SPEED HUMP POLICY and PROCEDURES for RESIDENTIAL AREAS

SPEED HUMP POLICY. It is the policy of Hamilton Township to consider requests for speed humps as outlined below:

Maintenance Maintenance of streetlights with the City of Belton is administered as follows:

Construction Realty Co.

DESIGN STANDARDS SECTION DS 3 STREETS

POLICY FOR THE ESTABLISHMENT AND POSTING OF SPEED LIMITS ON COUNTY AND TOWNSHIP HIGHWAYS WITHIN MCHENRY COUNTY, ILLINOIS

TIMBERVINE TRANSPORTATION IMPACT STUDY FORT COLLINS, COLORADO JANUARY Prepared for:

PERMIT FOR INSTALLATION ON COUNTY RIGHTS-OF-WAY: ACCESS DRIVEWAYS RESIDENTIAL

TRAFFIC IMPACT STUDY DERRY GREEN CORPORATE BUSINESS PARK MILTON SECONDARY PLAN MODIFICATION

Parking Areas and Driveways for Single and Two Family Dwellings

3.1 Overview of ATCO Electric s URD System Design

TITLE 16. TRANSPORTATION CHAPTER 27. TRAFFIC REGULATIONS AND TRAFFIC CONTROL DEVICES

Re: Amend Sections and File No ZA Marcus Lotson, Development Services Planner

Subchapter 20 Transportation

Town of Vermont Driveway Permit Ordinance

180 ZONING 180. ARTICLE XXX Parking Minimum required automobile parking spaces. [Amended by Ord. No. 464; by Ord. No.

Appendix C. Traffic Study

Proposed location of Camp Parkway Commerce Center. Vicinity map of Camp Parkway Commerce Center Southampton County, VA

Town of Goshen Driveway Regulations

EMERGENCY ACCESS POLICY

UNIFIED DEVELOPMENT CODE (UDC) INTERPRETATION. Commercial Vehicle Sales, Parts Sales and Services Facility

HARDEE COUNTY ROAD AND BRIDGE DEPARTMENT Driveway-Culvert Installation Permit

April 7, Mr. Blake Shutler Compass Homes Development LLC Summit Homes Construction, LLC PO Box 6539 Dillon, CO 80435

ZONING CODE PARKING REGULATIONS

Parking and Loading. Page 1 of 7

PART A: DRIVEWAY RULES CONTENTS

CITY OF WOODSTOCK APPLICATION FOR TRAFFIC CALMING/STREET CLOSURE

Chapter ACCESS, PARKING AND TRAFFIC*

Vista Municipal Code

3.15 SAFETY AND SECURITY

Article 6: Off Street Parking and Loading Standards. Table of Contents. page

Driveway Entrance Policy for Residential Properties - District 3 - All Wards

Support: The Crossbuck (R15-1) sign assigns right-of-way to rail traffic at a highway-rail grade crossing.

Background. Request for Decision. Pedestrian Lighting Standards for Road Right-of-ways. Recommendation. Presented: Monday, Mar 17, 2014

KENT COUNTY ROAD COMMISSION

TRAFFIC IMPACT ANALYSIS FOR. McDONALD S RESTAURANT IN CARMICAEL Sacramento County, CA. Prepared For:

DEVELOPMENT AGREEMENT APPLICATION MULTI-UNIT RESIDENTIAL DEVELOPMENT FOURTH STREET NEAR BEDFORD HIGHWAY SUBMITTED BY: LYDON LYNCH ARCHITECTS

CATEGORY 500 PAVING SECTION 535 PAVEMENT SURFACE PROFILE

CITY OF PLACENTIA RESIDENTIAL PERMIT PARKING PROCEDURES AND GUIDELINES 2017

TRAFFIC ENGINEERING ASSESSMENT MOUNT EDEN ROAD, MOUNT EDEN

INDUSTRIAL DEVELOPMENT

traversing them. Speed dips may be installed in lieu of speed humps where the 85 th percentile speed on a street is at least 36 mph.

a. A written request for speed humps must be submitted by residents living along the applicable street(s) to the Public Works Department.

City of Pacific Grove

TRAFFIC IMPACT STUDY FOR SONIC DRIVE-IN RESTAURANT. Vallejo, CA. Prepared For:

ARTICLE 7 OFF-STREET PARKING AND LOADING/UNLOADING 7.02 OFF STREET PARKING AND LOADING SPACE REQUIREMENTS

THE CORNERSTONE APARTMENTS TRAFFIC IMPACT STUDY R&M PROJECT NO

Transcription:

Access Management Standards This section replaces Access Control Standards on Page number 300-4 of the Engineering Standards passed February 11, 2002 and is an abridged version of the Access Management Policy approved by City Council on February 24, 2003. Administration The administrative procedures and related information for the implementation of access management guidelines include the following: Permit Application Process Location and Number of Driveways Variances Necessity for Traffic Impact Studies Access Permit/Deny Process NOTE: All interior lots on Access Level 7 streets should be exempted from these procedures. However, corner lots on Access Level 7 and all lots that access other than Access Levels 7 streets should follow these procedures. Permit Application Process A permit is required for a parcel or lot under the following conditions when: 1. Lot splits occur; 2. New access connection permits are requested; 3. Substantial enlargements or improvements are planned by developers; or 4. Significant change in trip generation figures are anticipated from the existing developments. The applicant requesting an access point should comply with the following steps: 1. Prior to the initial request for site plan approval or a building permit, the applicant should obtain a copy of the access requirements of the City of Sidney Engineering Department. 2. As a preliminary submittal, the applicant should provide at a minimum, a letter of explanation and request for consideration with the following information to the City Engineer.

Scale: 1 in. = 50 ft. unless otherwise approved by the City Engineer The name, address and telephone number of the owner(s) and that of the applicant, where the applicant is an agent (contractor, tenant, consultant) of the owner. The name of the property or development A location map with an appropriate scale showing the location of the property with respect to the area. All existing and approved access points within approximately 300 ft. of the property on both sides of the road. The identification of any legal rights-of-way or easements affecting the property as it relates to the roadway and proposed right-of-way acquisitions plus alternate access arrangements if appropriate (i.e., an access easement across neighboring property to a secondary road). The existing and proposed dimensions of the highway including through and turning lanes, shoulders, curbs, medians, bike paths, sidewalks, etc. Location and dimensions of the proposed access. 3. Upon review of the preliminary submittal by the City Engineer, the applicant should submit the final site plan(s) and, if required, the necessary support documentation. This documentation can include engineering plans, a traffic impact study, a cost estimate for highway improvements, and other supplemental studies. This is a final step in the application process. NOTE: The City Engineer has the right to waive any of the above information for a minor access point or for a temporary access situation, if the City Engineer determines that such information is not needed to secure a safe, low-impact access permit. 4. Any application that involves access to the Limited Access State Highway System shall be reviewed by the Ohio Department of Transportation for conformance with state standards. A letter of acceptance from ODOT shall be submitted before final approval is granted. Location and Number of Unsignalized Driveways Be default, each property is allowed one access point either independent or shared. For any additional access points, the applicant needs to provide enough justification that the additional access points improve the safety and traffic operations of the traffic movements from or into the development and do not deteriorate the traffic operations on the accessing street. When more than one driveway is requested, the property should have enough lot frontage to allow the driveways with the minimum spacing requirements shown in Tables 3-1 to 3-4.

The location and number of driveways should be based on the following factors: 1. Size of the development (Minimum-use, Minor, Medium, or Major Traffic Generator) 2. Access level of the accessing street (Access level 1 to 7. Access levels 1 and 2 do not allow direct access) 3. Speed limit of the accessing street (25 MPH to 55 MPH) 4. Available lot frontage 5. Location of lot (interior vs. corner) 6. Location of opposite driveways. Figures 5-1 to 5-4 show the typical locations of driveways. Figures 5-1 and 5-2 are the conditions for properties with a single driveway requirement interior and corner lots respectively. Figures 5-3 and 5-4 are the conditions for the properties with multiple driveway requirement interior and corner lots respectively. As shown in the figures, the following parameters are used to define the location of driveways. These parameters will help in determining not only the location but also the number of allowable driveways based on the available lot frontage. L 1 Minimum distance between driveways. Minimum requirements are shown in Tables 3-1 to 3-4. L 2 Minimum distance from the Property Line (P/L). The values are one-half of L 1. L 3 Minimum distance from the cross-street Right-of-way (R/W). Minimum requirements are shown in Table 3-5. L 4 Acceptable distance from the cross-street R/W line. The values are maximum of L 1 or L 3. L Minimum required lot frontage. Figure 5-1: Typical Location of Driveway One Driveway Interior Lot Figure 5-2: Typical Location of Driveway One Driveway Corner Lot P/L Lot 1 P/L R/W Lot 1 P/L L 2 L L 2 C r o s s L 4 L L 2 Access Street S t r e e t Access Street

Figure 5-3: Typical Location of Driveway Multiple Driveways Interior Lot P/L Lot 1 L P/L L 2 L 1 L 1 L 2 Access Street Figure 5-4: Typical Location of Driveway Multiple Driveways Corner Lot C r o s s R/W L 4 L 1 L L 1 L 2 S t r e e t Lot 1 Access Street P/L Where: L = Minimum Lot Frontage L 1 = Unsignalized driveway spacing (Value from Tables 3-1 to 3-4) L 2 = L 1 /2 L 3 = Lateral Clearance (Value From Table 5-1) L 4 = Maximum of L 1, L 3 Access Classification Map The access classification map within the City of Sidney is shown in Figure 2-2.

Figure 2-2: Access Classification Map

When determining the location and number of unsignalized driveway access, special attention should be given to the following conditions: The size of generator should be computed based on: o Land use of the whole parcel (parcels which are proposed to be split into smaller lots). o Land use of the lot itself (for all existing and approved lots). Minimum-use generators should be restricted to a single driveway unless justified. If the property has alternative access possibilities, the access should be encouraged on to the highways with lower access classification. If any property shares the driveway s of another property, the value of L 2 =0 in figures 5-1 to 5-4 only on the shared side. Therefore, minimum lot frontage requirements for such properties can be reduced by the value of L 2. Access points in to three legged signalized intersections should not be allowed unless it is justified through the traffic impact study. Wherever the unsignalized approaches on both sides of the accessing street are not aligned, safe off-sets as shown in Table 3-6 should be maintained as agreed by the City Engineer. Minimum-use generators are exempted from this requirement. Minimum-use and minor generators should be exempted from the requirements of barriers shown in Figures 2-6 and 2-8 for access onto undivided Access level 3 and 4 streets respectively. Minimum-use and minor generators should be exempted from the requirement of exclusive left turn lanes on access level 5. Minimum-use and minor generators should be exempted from the requirement of exclusive left turn lanes on access level 6. If an undivided roadway becomes divided, left-turn access should be subject to elimination in one or both directions.

Unsignalized Driveway Spacing Guidelines developed for unsignalized driveways are based on speed and access level of the main road, and size of the development (or traffic generator). Four magnitudes of traffic generators are used in developing the spacing criteria: Minimum-Use Generator Developments that generate up to a total of 50 vehicle trips in the peak hour in both directions. Minor Generator Developments that generate a total of 51 to 250 vehicle trips in the peak hour in both directions. Medium Generator Developments that generate a total of 251 to 500 vehicle trips in the peak hour in both directions. Major Generator Developments that generate a total of more than 500 vehicle trips in the peak hour in both directions. Note that these generators sometimes warrant signals for some or all of its driveways. The latest Trip Generation Manual published by the Institute of Transportation Engineers (ITE) should be used as a tool in determining the type of generator. The manual includes data/methods to estimate the number of trips generated for a developments based on the land use and size of the center. Based on the estimated number of trips, the development can be classified under one of the four generators. The peak hour to identify the number of trips is defined as the peak hour of the generator. Such a peak hour can fall on any day of the week and any time of the day. Minimum spacing guidelines for unsignalized driveways for minimum-use, minor, medium and major generators are shown in Tables 3-1, 3-2, 3-3, and 3-4 respectively. As shown in the tables access levels 1, 2, 3 and 7 are not included. Access levels 1 and 2 do not allow direct access on to the highways that are designated as access levels 1 or 2. Therefore, there are no driveways spacing guidelines for access levels 1 and 2. Access level 3 streets do not exist currently and therefore spacing guidelines for this category are not included. Since the location and spacing of driveways on access level 7 streets are based on only safety, there are no driveway spacing standards set for access level 7 streets. Table 3-1: Minimum Lot Width/Driveway Spacing (in feet) for Minimum-use Generators Access Speed in MPH Level 25 30 35 40 45 50 55 4 100 120 140 160 180 200 220 5 75 90 105 130 145 160 175 6 50 60 70 80 90 100 100

Table 3-2: Minimum Lot Width/Driveway Spacing (in feet) for Minor Generators Access Speed in MPH Level 25 30 35 40 45 50 55 4 130 160 190 220 250 280 310 5 100 120 140 160 180 200 220 6 75 90 105 130 145 160 175 Table 3-3: Minimum Lot Width/Driveway Spacing (in feet) for Medium Generators Access Speed in MPH Level 25 30 35 40 45 50 55 4 175 210 245 280 315 350 385 5 125 150 175 200 225 250 275 6 100 120 140 160 180 200 220 Table 3-4: Minimum Lot Width/Driveway Spacing (in feet) for Major Generators Access Speed in MPH Level 25 30 35 40 45 50 55 4 230 275 320 365 410 455 500 5 175 210 245 280 315 350 385 6 125 150 175 200 225 250 275 Corner Lots For corner lots, access spacing for the first access point from cross-streets of access level 2 though 7 shall also meet lateral access restrictions. Table 3-5 shows the lateral access restrictions. The distance between the first access point of a corner lot from a cross-street shall be the maximum of a relevant value from Tables 3-1 to 3-4 and the value from Table 3-5. Table 3-5: Minimum Lateral Clearance (in feet) for Corner Lots Generator Type Access Level of Cross Street 2 4 5 6 7 Minimum-Use 100 100 50 50 50 Minor 125 125 75 75 75 Medium 150 150 100 100 100 Major 330 330 150 150 150

Opposing Driveways On undivided roadways, access on both sides of the road should be aligned. Wherever this is not possible, driveways should be off-set based upon the generator types on both sides of the road as shown in Table 3-6. Minimum-use generators should be exempted from this requirement. Generator Type on Accessing Side Table 3-6: Minimum Off-sets between Opposing Driveways Generator Type on Opposite Side Minimum Off-set Minor Minimum-Use N/A Minor Minor 150 to 200 feet Minor Medium 150 to 200 feet Minor Major 300 to 400 feet Medium Minimum-Use N/A Medium Minor 150 to 200 feet Medium Medium 150 to 200 feet Medium Major 300 to 400 feet Major Minimum-Use N/A Major Minor 300 to 400 feet Major Medium 300 to 400 feet Major Major 300 to 400 feet Signalized Intersections Intersection/driveway signalization in conjunction with highway access shall be permitted only when the signal is warranted. Traffic signal warrant analysis shall be based upon the latest Ohio Manual of Uniform Traffic Control Devices (OMUTD) published by the Ohio Department of Transportation (ODOT). Turn lane requirements at signalized locations should be based on capacity analysis using the latest Highway Capacity Manual (HCM) methods. Driveway Design Elements When a new driveway is placed or an existing driveway is modified, it is important to follow design standards that make the traffic movements on the driveway safe and easy to operate and maintain. This section includes design standards for basic elements of the driveway - design vehicle; driveway width; turning radii; driveway profile; driveway pavement; and driveway storage lengths.

The standards shown in this chapter are for unsignalized driveways only. For signalized intersections/driveways, a detailed study and analysis should be done before the design is initiated and such design should be based on standard engineering practices. The recommended standards to the city for unsignalized driveways are based on the State Highway Access Management Manual by ODOT. Driveway design is dependent upon several factors. The driveway type will determine what type of vehicles are to be considered in the design which, in turn, affects the access width along with the radius and/ or flare dimensions. Driveway Types Residential A driveway providing access to a single family residence, to a duplex, or to an apartment building containing not more than four dwelling units. Commercial A driveway providing access to an office, business, retail or institutional building, or residential facility having five or more dwelling units. These establishments are customarily serviced by trucks as an incidental rather than a principal driveway use. Industrial plant driveways whose primary function is to serve administrative or employee parking lots are considered commercial driveways. Farm/Field A driveway providing access to an agricultural tract of land. Industrial/Retail A driveway directly serving a substantial numbers of truck movements (equal to or greater than 10 trucks per day) to and from loading docks of an industrial facility, warehouse, or truck terminal. A centralized retail development, such as a community or regional shopping center, may have one or more driveways, specially designed, signed and located to provide access for trucks. These also are classified as industrial driveways. Driveway Dimensions Dimensions of any driveway should be based on the latest revision of City of Sidney Engineering Standards. Driveway Profile Profiles of any driveway should be based on the latest revision of City of Sidney Engineering Standards. Driveway Pavement Pavement details of any driveway should be based on the latest revision of City of Sidney Engineering Standards.

Driveway Storage Lengths (Throat Lengths) Adequate driveway storage length or Throat Length as shown in Figure 4-1 is necessary for access points to: Enable vehicles entering highway to enter at comfortable distance between vehicles, and Prevent spill back onto the development internal road system Figure 4-1: Location of Driveway Throat In general, traffic volume is the main controlling factor in evaluating storage lengths. Storage requirements should be based on the peak highway traffic hours, or the peak hour of the generator, whichever is larger. The latest Trip Generation Manual, Published by the Institute of Transportation Engineers (ITE), should be used as a tool to determine the peak hour traffic volumes of the generator. After determining traffic volumes, storage lengths can be computed using the latest edition of the Location and Design Manual: Volume One by ODOT. Some general requirements are suggested for storage lengths of each driveway based on the type and size of the generator, but these requirements may vary according to the projected volume of the individual driveway. 1. Storage lengths of at least 50 ft. should be provided for minimum-use and minor traffic generators. 2. Storage lengths of at least 150 ft. with two (2) exit lanes or more should be provided for medium traffic generators. 3. Storage lengths of greater than 200 ft. with two (2) exit lanes or more should be provided for major traffic generators.

Variances In circumstances where the City Engineer find that approved access requirements may result in extraordinary hardships or practical difficulties, the City Engineer may allow variances to the access requirements. In order to review a request for a variance, the City Engineer may require a Traffic Impact Study or other information or studies. For any variance, the applicant should submit a written petition to the City Engineer. The City Engineer will grant a variance whenever it is determined that all of the following conditions are met: 1. The granting of the variance would not result in undue delay or congestion or unsafe conditions to the motoring public using the roadway. 2. The applicant must provide proof of unique or special conditions that would not allow the development to procure reasonable access as per the guidelines. Please note that the City Engineer will not grant a variance if any of the following can be applied to the proposed access: Where reasonable alternate access by an existing road or street other than the primary road is possible. Where indirect or restricted access can be obtained. Where reasonable engineering or construction solutions can be applied to mitigate the condition. 3. The applicant must provide proof that access is essential to the development needs and clear documentation of the practical difficulty or unnecessary hardship. No variance should be granted where such difficulty or hardship is self-created in the opinion of the City Engineer. Upon receipt of relevant information, facts, documentation, and necessary data and /studies, the City Engineer will review the information and inform the applicant concerning its finding and conclusions on granting a variance. Traffic Impact Studies A traffic impact study may be an integral part of the access permit process. It should generally deal with site-generated traffic, the directional distribution of traffic and the assignment of the site traffic onto existing and/or proposed roadways. In certain circumstances, for Traffic Impact Studies, the City Engineer may require the inclusion of off-site traffic from other proposed developments that will impact area roads.

A Traffic Impact Study is required when: 1. All developments that can be expected to generate more than 250 peak-hour vehicle trips on the adjacent street, or for a lesser volume when the developments are in high accident locations, currently congested areas or areas of critical local concern. 2. When the original traffic impact study is more than three (3) years old, access decisions are still outstanding, and/or changes in development have occurred in the site conditions. The study is to be prepared under the supervision of qualified traffic engineers with specific experience in the preparation of traffic impact studies. The studies should be completed in accordance with the standards published by the Institute of Transportation Engineers in its latest Manual of Transportation Engineering Studies. Access Permit / Deny Process Upon review of all relevant information provided by the applicant for an access permit, the City Engineer has the right to either grant or deny the permit. A detailed process to be followed by the City Engineer for access approval/denial is shown in a flow chart as Figure 5-5. The process considers: (1) the size of development for which access is required, (2) the functional and access classification of the roadway to which access is requested, (3) the type of access requested to the allowable levels and types of access, (4) highway and intersection capacity, (5) geometric design considerations, (6) the type of proposed traffic control, (7) relevant spacing standards along with minimum lot frontage criteria, and (8) the need to, if required, apply a variance to the permit criteria. If the application is approved with conditions, the applicant shall resubmit the plan with the conditional changes made. The plan, with submitted changes, will be reviewed within 10 working days and either approved or denied. If the access permit is denied, the City Engineer should provide a written accounting detailing why the application has been rejected. Appeal Process If the applicant does not agree with City Engineer s decision on the access permit, the applicant may appeal to the City Manager. Permit Review Process Flow Chart The permit review process for the City of Sidney is shown in Figure 5-2.

Figure 5-2: Permit Review Process