MPH Maximum pressure bar F l o w r a t e s t o l / m i n 6
echnical data housing (Materials) Head: luminium: MPH ---- nodised luminium: MPH 6-8 Painted luminium: MPH 66 Cover: Nylon: MPH --- luminium: MPH nodised luminium: MPH 6 Painted luminium: MPH 66 Steel: MPH 8 Insert assembly: Nylon (only for: MPH ---) luminium (all the other) Diffuser: Zinc Plated Steel (excluded MPH 8) inned Steel: MPH 8 Valve: Phosphated Steel Pressure Working pressure: bar emperature From - C to + C ypass valve Opening pressure,7 bar ±% Opening pressure, bar ±% (excluded for MPH 8) housings Δp pressure drop he curves are plotted utilising mineral oil with density of.86 kg/dm to ISO 968. Δp varies proportionally with density. Δp bar,,7,, MPH - - - / 8 6 Flow rate l/min / Δp Elements type Series MR elements: bar Oil flow from inside to outside. Seals Standard NR series,6 MPH Optional FPM series V MPH FILERS RE PROVIDED FOR VERICL MOUNING, / Weights (kg) Length MPH -,6,7,8,,6 MPH -,6,7,8,,6 MPH,6,9,,6 - MPH 6 6, 7, 7, 8,, MPH 66 - - -, MPH 8 8 - Δp bar,8, / 6 8 6 Flow rate l/min Volumes (dm ) Length MPH -,6,7,8,,6 MPH -,6,7,8,,6 MPH,,, 8, - MPH 6 7, 9,, 9, MPH 66 - - -,6 MPH 8 6, -,6, MPH 6 Compatibility (to ISO 9) Housings/Diffuser compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). Δp bar,8, he filter elements are compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol (series W required). 8 7 96 Flow rate l/min NR seals series, compatible with: Mineral oils, synthetic fluids. queous emulsions, water and glycol. FPM seals V series, compatible with: Synthetic fluids type HS-HFDR-HFDS-HFDU 7
,, MPH 66 DN 8 6, MPH 6-66, bar Δp bar, DN Δp bar,7 bar,, 8 96 9 Flow rate l/min 8 7 96 Flow rate l/min, MPH 8 MPH 8, DN,7,7 bar Δp bar, Δp bar,,, 6 8 Flow rate l/min 6 8 Flow rate l/min Valves ypass valve pressure drop ir breather Pressure drop,7 MPH - - -, bar,, MPH - Δp bar,,7 bar Δp bar,,, 8 6 Flow rate l/min 6 8 Flow rate l N /min MPH : C With air breather μ : D With anti-splash and SP μ, bar Δp bar,7 bar 6 8 6 Flow rate l/min 8
Recoended maximum flow rate - Pressure drop of filter assembly equal to Δp, bar. - Oil kinematic viscosity /s (cst). - Density,86 kg/dm. Filtration Length 6 6 P P M - M6 - M9 MPH - - 6 6 89 9 7 98 7 8 8 98 8 6 6 7 6 6 6 8 8 87 8 MPH 9 8 9 6 7 6 8 7 7 66 7 7 7 7 7 MPH 6 6 7 6 98 7 69 6 7 87 8 6 77 99 6 8 68 MPH 66 7 6 699 89 8 7 7 7 7 7 7 MPH 8 77 7 8 66 9 8 68 99 7 6 6 68 6 9 Flow rate l/min 9
Dimensions MPH Without air breather H Indicator port 8 H H 97 Ø 86 Seal O-Ring With diffuser Without diffuser Ø 8 Ø 7 6 68 Holes on the tank hread connections Ø 87 - Ø 89 M Ø - Ø 6 G G G G G G6 G7 G8 G9 G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN G /8 G /8 G /8 /8 NP /8 NP /8 NP /8 NP /8 NP /8 NP Length H 9 9 H 7 H 6
MPH 6 H 8 99 Ø 86 Flat seal H With diffuser Without diffuser H Version S Without air breather Ø 8 Ø 7 Version C With air breather Version D and P nti-splash and SP 8 Indicator port 7 68 Holes on the tank - 6 Ø 89 - Ø 9 M 98 indicator port G / - / NP ON REQUES hread connections G G G G G G6 G7 G8 G9 G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN G /8 G /8 G /8 /8 NP /8 NP /8 NP /8 NP /8 NP /8 NP Length H 88 88 8 8 8 H 9 7 88 H hread hread connections connections G - G - G G - G - G6 G7 - G8 - G9 G /8 /8 NP SE 6-9/6-8 UNF G / / NP SE 8 - / - 6 UNF 6
MPH 99 H Ø 86 Flat seal H With diffuser Without diffuser H 8 Ø 8 Ø 7 Version S Without air breather Version C With air breather Version D and P nti-splash and SP Indicator port 8 Ø 7 68 98 88 Holes on the tank indicator port G / - / NP hread connections Ø 89 - Ø 9 Ø - Ø 6 M ON REQUES Length H 88 88 8 8 8 H 9 7 H G G G G G G6 G7 G8 G9 G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN G /8 G /8 G /8 /8 NP /8 NP /8 NP /8 NP /8 NP /8 NP 6
MPH H With diffuser 6 Ø 86 Without diffuser Flat seal H 99 H 8 Ø Ø 8 Ø 7 Indicator port C Holes on the tank - 6 Ø 87 - Ø 89 M Indicator port 68 68 hread connections and C G G G G G G6 G7 G8 G9 G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN C G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /6 - UN G /8 G /8 G /8 /8 NP /8 NP /8 NP /8 NP /8 NP /8 NP Length H 88 88 8 8 8 H 9 7 H indicator port G / - / NP ON REQUES hread connections G - G - G G - G - G6 G7 - G8 - G9 hread connections G /8 /8 NP SE 6-9/6-8 UNF G / / NP SE 8 - / - 6 UNF 6
MPH connection port MPH connection port H 9 H 9 9 9 H H Ø Ø Ø 6 Ø D version O version 9 H H Ø 6 Ø D version O version Seal Flat seal Holes on the tank Holes on the tank Ø, Ø, Ø 7 M Ø 7 M hread connections Flange connections* G G G G G7 G8 G / G / / NP / NP SE - 7/8 - UN SE - 7/8 - UN - G / - / NP - SE - /8 - UN G /8 G /8 /8 NP /8 NP /8 NP /8 NP Length H 7 7 7 7 H 8 H 7 8 F F F F / SE psi/m / SE psi/m / SE psi/unc / SE psi/unc - / SE psi/m - / SE psi/unc *Connections table DN - SE flange see page G /8 G /8 /8 NP /8 NP 6
MPH 6 MPH 66 H H 8 H Flat seal 6, 7, H 8 H Flat seal H, Ø 6 Ø 6, Ø 6 D version O version 86 Ø 6 Ø 6 D version O version 86 Holes on the tank 9 Ø Ø 66, M 9 9 M Ø Ø 66, Holes on the tank MPH 6 Length H 78 8 8 8 88 H 6 8 89 MPH 6 Flange connections* F F F F H 6 9 / SE psi/m / SE psi/m / SE psi/unc / SE psi/unc SE psi/m SE psi/unc *Connections table DN - SE flange see page G /8 G /8 /8 NP /8 NP MPH 66 Length H 8 88 H 8 88 MPH 66 Flange connections* 9 H 6 9 F F SE psi/m SE psi/m G /8 G /8 *Connections table DN - SE flange see page 6
MPH 8 Connection type F - F (DN - SE) Connection type F - F6 - F7 - F8 (SE - SE) Indicative view for connection DN - SE Indicative view for connection SE -SE H Flat seal 8 87 H H H Ø Ø Ø 7 D version O version Holes on the tank M, Ø 9 Ø, G /8 Indicator port Ø SE - SE Flange connections* Length H 9 6 9 79 H 8 98 878 H H 7 7 DN - SE Flange connections* F DN PN /6 UNI F DN PN /6 UNI SE psi/m SE psi/unc F F6 F7 F8 SE psi/m SE psi/unc SE psi/m SE psi/unc SE psi/m SE psi/unc *Connections table DN - SE flange see page 66
Spare parts a d b c f e Item Description Q.ty FILER Series MPH assembly Seal Kit NR FPM 9 9 a Cover seal Ø 9 x b External seal for insert assembly with diffuser External seal for insert assembly without diffuser 6 66 O-R 7 Ø 69, x, c Diffuser seal O-R Ø 78,97 x, d Insert assembly 9 9 e Head seal without air breather Ø 9 x f seal Ø 7, x 67
Spare parts i 6 a g d h h b g c f e Item Description Q.ty FILER Series MPH FILER Series MPH assembly a b c Seal Kit Cover seal External seal for insert assembly with diffuser External seal for insert assembly without diffuser Diffuser seal NR FPM 6 66 Ø 9 x 6 66 O-R 7 Ø 69, x, O-R Ø 78,97 x, NR FPM 8 8 Ø 9 x 6 66 O-R 7 Ø 69, x, O-R Ø 78,97 x, d Insert assembly internal seal 69 696 69 696 e f Head seal seal 6 6 Ø 7, x 67 67 Ø 7, x g ir breather screw seal 66 67 66 67 h i 6 Plug - nti-splash seal SP seal ir breather filter element C version ir breather filter element D version ir breather filter element P version O-R Ø,99 x,6 O-R 68 Ø 7,7 x,78 micron L micron SPGLP micron SPGLP O-R Ø,99 x,6 O-R 68 Ø 7,7 x,78 micron L micron SPGLP micron SPGLP 68
Spare parts a d b c f e Item Description Q.ty FILER Series MPH assembly Seal Kit NR FPM 67 68 a Cover seal Ø 9 x b External seal for insert assembly with diffuser External seal for insert assembly without diffuser 6 66 O-R 7 Ø 69, x, c Diffuser seal O-R Ø 78,97 x, d Insert assembly internal seal 69 696 e Head seal 66 66 f seal Ø 7, x 69
Spare parts a b c d e Item Description Q.ty FILER Series MPH MPH 6 assembly Seal Kit NR FPM NR FPM a Cover seal Ø 9 x,7 Ø 9, x,7 b Insert assembly external seal O-R 7 Ø,7 x, O-R Ø, x, c Insert assembly internal seal 67 6 68 69 d Head seal 69 66 6 66 e seal O-R Ø 9,9 x,6 O-R Ø 9,9 x,6 7
Spare parts a b c d e Item Description Q.ty FILER Series MPH 66 assembly Seal Kit NR FPM a Cover seal Ø 9, x,7 b Insert assembly external seal O-R Ø, x, c Insert assembly internal seal 68 69 d Head seal 6 66 e seal O-R Ø 9,9 x,6 7
Spare parts a b c d e Item Description Q.ty FILER Series MPH 8 assembly Seal Kit NR FPM 6 a Cover seal 68 66 b Insert assembly external seal Ø 9, x,7 c Insert assembly internal seal 68 69 d Head seal 6 66 e seal O-R 7 Ø, x,6 7
Ordering information MPH - assembly MPH MR Example : MPH C D S G P Example : MPH E D C G M6 P 8 6 9 Example : MR P Example : MR M6 P 6 7 8 9 - Style - length - y-pass valve S Without bypass C,7 bar E, bar - Execution O Without diffuser and with magnetic column * D With diffuser and with magnetic column E Without diffuser and without magnetic column * F With diffuser and without magnetic column 7 - Connections MPH - G G G G G G6 G7 G8 G9 G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN 8 - Inorganic microfibre 6 μ Inorganic microfibre μ Inorganic microfibre μ M M6 M9 Wire mesh Wire mesh Wire mesh bsolute filtration ßx (c) Nominal Filtration - ir breather S C D P Without air breather () With air breather μ () nti-splash and SP μ air breather () nti-splash, SP μ air breather and pressurization, bar P P 9 - Option P Resin impregnated paper Resin impregnated paper MP Filtri standard Nominal Filtration () Excluded MPH 6 - seals & reatment V W Z NR FPM NR, Head anodized - filter element compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) FPM, Head anodized - filter element compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) * Use of diffuser reccomended MP Filtri - he filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved he data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or coercial requirements. he colours of the products shown on the cover are purely guideline. Copyright. ll rights reserved. 7
Ordering information MPH - assembly MPH MR 6 Example : MPH E D C G P Example : MPH C O G P 9 6 Example : MR P Example : MR P 7 8 9 - Style - length - y-pass valve S C E - Execution * * O D E F 6 - seals & reatment V W Z Without bypass,7 bar, bar Without diffuser and with magnetic column With diffuser and with magnetic column Without diffuser and without magnetic column With diffuser and without magnetic column - ir breather (omit for MPH ) S C D P Without air breather With air breather μ nti-splash and SP μ air breather nti-splash and SP μ air breather pressurization, bar NR FPM NR, Head anodized - filter element compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) FPM, Head anodized - filter element compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) 7 - Connections - C MPH Connections MPH Connections and C G G G G G G6 G7 G8 G9 8 - Connections - Option P G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /8 - UN G - G - G G /8 G / 9 - Connections G - G - G6 /8 NP / NP MP Filtri standard C G / G G / / NP NP / NP SE - /6 - UN SE 6 - /6 - UN SE - /6 - UN Inorganic microfibre μ 6 Inorganic microfibre 6 μ Inorganic microfibre μ 6 Inorganic microfibre 6 μ Inorganic microfibre μ M M6 M9 P P Wire mesh Wire mesh Wire mesh Resin impregnated paper Resin impregnated paper G7 - G8 - G9 SE 6-9/6-8 UNF SE 8 - / - 6 UNF bsolute filtration ßx (c) Nominal Filtration Nominal Filtration * Use of diffuser reccomended 7 MP Filtri - he filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved he data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or coercial requirements. he colours of the products shown on the cover are purely guideline. Copyright. ll rights reserved.
Ordering information MPH -6-66-8 assembly MPH MR 6 7 8 9 Example: MPH C D S G P 8 6 9 Example: MR P - Style 6 6 66 6 8 8 - length - y-pass valve S C - ir breather S Without air breather 6 - seals & reatment V W Without bypass,7 bar E, bar (not available for MPH 8) - Execution * * O D E F Without diffuser and with magnetic column With diffuser and with magnetic column Without diffuser and without magnetic column With diffuser and without magnetic column NR FPM 6 66 8 NR, Head and Insert assembly anodized. compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) 7 - Connections MPH G G G G G7 G8 F F F F G / G / / NP / NP SE - 7/8 UN SE - 7/8 UN / SE psi/m / SE psi/m / SE psi/unc / SE psi/unc MPH 6 - G / - / NP - SE - /8 - UN - / SE psi/m - / SE psi/unc F F F F / SE psi/m / SE psi/m / SE psi/unc / SE psi/unc SE psi/m SE psi/unc MPH 66 MPH 8 DN-SE F SE psi/m F DN PN /6 SE F SE psi/m UNI psi/m F DN PN /6 SE UNI psi/unc MPH 8 SE-SE F F6 F7 F8 SE psi/m SE psi/unc SE psi/m SE psi/unc SE psi/m SE psi/unc 8 - Inorganic microfibre 6 μ Inorganic microfibre μ Inorganic microfibre μ M M6 M9 Wire mesh Wire mesh Wire mesh bsolute filtration ßx (c) Nominal Filtration Z FPM, Head and Insert assembly anodized. compatible with fluid HF, HF, HFC (only for filter element type xx and Mxx) P P Resin impregnated paper Resin impregnated paper Nominal Filtration 9 - Option * Use of diffuser reccomended P MP Filtri standard MP Filtri - he filter functions as described in this bulletin are valid exclusively for original MP Filtri filter elements and replacement parts. ll rights reserved he data in this publication are purely guideline. MP Filtri reserves the right to make changes to the models described herein at any time it deems fit in relation to technical or coercial requirements. he colours of the products shown on the cover are purely guideline. Copyright. ll rights reserved. 7