EPM1510SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Similar documents
Power Modules (Power Supplies with Ultra-low Standby Power Consumption) DC V

MPM0527SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

BPM2417SJ Datasheet. Power Modules (Power Supplies with Ultra-low Standby Power Consumption) TAMURA CORPORATION Rev.

Efficiency More than 80% Rated input voltage Rated output current Output voltage tolerance ±5%

Maximum input voltage 420V or less Including peak value

No-load power 50mW or less (17mW TYP) Rated input voltage. Ripple noise 300mVp-p or less Rated output current

DM Series Gate Driver Module

Five Improvements by Power Supply Modules. Switching power supply and power modules. External Dimensions / Pin assignment, SPM Series

Absolute Maximum Ratings Item Symbol Min Max Unit Conditions Note Input voltage for DC/DC converter V IN Vdc Between Vin(+) to Vin(-)

RP Instruction Manual

Applications. Output Voltage (V) V21 = 2

EVS RP6020. Instruction Manual

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

DC/DC Converter Application Information

DC/DC Converter Application Information

DATA SHEET FUSIBLE ALLOY THERMAL SENSITIVE PELLET TYPE, 2 AMPERES RATED CURRENT

DATA SHEET ORGANIC THERMAL SENSITIVE PELLET TYPE 10 AMPERES RATED CURRENT

S-8209B Series Usage Guidelines Rev.1.5_02

ACTIVE ORING CONTROLLER MODULE

Ratings 0402 inch size : Type ERBRD ERBRD R X 0R25 0R3 0R37 0R50 0R75 R00 R25 R50 2R00 2R50 3R00 Rated Current (A)

Metal Film Fuse Resistors

DRB-1 Series Instruction Manual

DRL-1 Series Instruction Manual

<Designed to meet harmonic current regulations> Board type, ultra-small size, and low cost

MYPMA01218RCF-CAB Non-isolated type

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

User s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation

Small Type High-Speed Response POL DC-DC Converter BSV-nano Series

High Temperature Film Capacitor for Automotive

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

User s Manual Power Supply IM E. 5th Edition

MEMS Gauge Pressure Sensor

Selection Guide SANKEN ELECTRIC CO.,LTD

Basic Characteristics Data

DC/DC Converter Reference Circuit

Switching Power Supply

Notice for TAIYO YUDEN Products

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

LS200 Series Instruction Manual

PS6R 480W Switching Power Supply

3. Block Diagram Pin Number, Function Pin No. Symbol Function 4. Environmental Conditions 1 Vin1 Ch1 Voltage Input Terminal 2,3 Vin23 Ch2,3 Voltage In

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

G3PE-Single-phase. Solid State Relays for Heaters

Pressure Sensor/PS-A (ADP5)

Basic Characteristics Data

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

G3PE-Single-phase. Solid State Relays for Heaters

CCG Series Instruction Manual

TDK-Lambda ZWS240BP/A SPECIFICATIONS

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

HL (AZH) Limit Switches

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

High-power Solid State Relays G3PH

POWER-WIN TECHNOLOGY CORP.

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Table 2 Models BST12M-0.7S03PDM BST12M-0.7S06PDM BST12M-0.7S10PDM Conditions Input voltage range

DC-DC Converter DATA Sheet

C B. Operating up to 5000m altitude 5 year product warranty Models

HWS 15A-150A Series. Instruction Manual

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

DC9~ typ max 40max 80max. 71 typ max. 120max 120max. 120max. 120max. 60max. 48max. 20max

China - Germany - Korea - Singapore - United States - smc-diodes.com

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Solid State Relays G3NA. Model Number Structure. Model Number Legend

Ordering Information. MEMS Gauge Pressure Sensor 2SMPP. MEMS Gauge Pressure Sensor Featuring Small Size and Low Power Consumption

362 Clamp Meter. Users Manual

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

PRODUCT SPECIFICATION File: EA-400H2U-02 Date: Feb., 16, 2005

ZWD100PAF. Conformity to RoHS Directive

MD60 Series 60W DINergy Power Supply

PFE700SA Series Instruction Manual

720 W / 24 V On-board Battery Charger. for industrial applications. Product Data Sheet

AC/DC Converter MBP250-2A13D13M

PHU series. Caution. Products in this catalog are in preparation for mass production. For automotive. PiezoHapt TM Actuators PHUB A

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

PRODUCT SPECIFICATION File: EA- 400ET1-10 Date: Jul., 28, 2006

Model Number Structure

DC-DC Converter DATA Sheet

Portable Instruments. Bulletin 2000-E

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DC-DC Converter DATA Sheet

1 Terminal Block A-22

Model Number Structure

GB60S 60W Single Output General Purpose Series

High-power Solid State Relays G3PH

PRODUCT SPECIFICATION File: EA-600ETF-C10 Date: Mar. 29, 2010

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

UCS-CHR24V55W. Combined Power Supply & Battery Charger. Data Sheet

MJWI20 SERIES FEATURES PRODUCT OVERVIEW. DC/DC Converter 20W, Highest Power Density MINMAX MJWI20 Series

Transcription:

Power Modules (Power Supplies with Ultra-low Standby Power Consumption) EPM1510SJ Datasheet Features 1.Easy to design compact AC/DC due to small number of external components 2.Enables significant reduction in power consumption of no-load and light load 3.Corresponding world wide input and PFC output voltage (Vin:DC110V~450V) 4.Unique Tamura design insures significant reduction in buzz under light-load conditions for lower noise level 5.Reinforced insulation Applications Industrial equipment Information processing equipment AV equipment Home electric appliances Other standby power supplies and compact power supplies Certified safety standards UL60950-1, CSA C22.2 No.60950-1 (E132244) IEC60950-1(CB), IEC60065(CB) Certified input voltage range DC110-340V Applicable safety standards UL/CSA/IEC/EN60950-1 UL/CSA/IEC/EN60065 IEC/EN60335-1 Applicable input voltage range DC110-340V DC110-340V DC110-450V Application circuit Method to select external parts for input rectification and smoothing as well as output smoothing is supported by the application note. 1 / 9

Input-output condition Item Specification Conditions Note Input voltage range DC110~450V Average voltage (DC50V~450V) (Refer to the Input voltage derating curve) Maximum input voltage 450V or less Including peak value EPM1510SJ Datasheet Input ripple voltage lower limit Rated input voltage Rated output voltage Rated load current 80V or more DC140V, DC340V 15V 1A Ripple voltage of the AC input rectified Electrical specification Ta=25 Item Specification Conditions Note Efficiency 80% or more Rated input voltage Rated output current Output voltage tolerance ±5% Line regulation 100mV or less Input voltage DC110V~450V Load regulation 250mV or less Output current 0~1A No-load power 80mW or less Rated input voltage Ripple 150mVp-p or less Rated input voltage Ripple noise 200mVp-p or less Rated output current Measurement circuit 14 Drain Module 12 +DC IN E1 W1 C101 11 Vcc 10 -DC IN 9 VccW 8 SecW +DC OUT -DC OUT 4 5 6 7 C201 L201 C202 150mm 150mm C203 C204 V1 P1 LM1 RL1 C102 E1 : DC power supply W1 : Power meter WT210 (YOKOGAWA) RL1: Electronic load V1 : Voltmeter Class 0.5 P1 : Differential probe DP-100(KG) LM1: Ripple noize meter RM-103(KG) C101 : 450BXC33M (RUBYCON) C102 : CD70ZU2GA102M (TDK) C201 : 25ZLG330M (RUBYCON) C202 : 25ZLG330M (RUBYCON) C203 : 25ZLG47M (RUBYCON) C204 : 50F2D104K (RUBYCON) L201 : PJ5H-2R2M (KORIN ) 2 / 9

Protection Item Specification Conditions Note Overcurrent protection 1.3A or more Hiccup mode Overvoltage protection 16.5~22V Latch off EPM1510SJ Datasheet Overheat protection Latch off Insulation Item Specification Conditions Note Dielectric withstand voltage AC3.75kV 1min Cutoff 2mA (Between Pri-Sec) Insulation resistance 100MΩ or more DC500V (Between Pri-Sec) Environmental conditions Item Specification Conditions Note Operation temperature -20 ~80 Refer to the Ambient temperature derating curve Operating humidity Storage temperature Storage humidit 20~95%RH (No condensation) -25 ~85 5~95%RH (No condensation) Ambient temperature derating curve Reduce the load current according to the following temperature derating table. Input voltage derating curve Reduce the load current according to the following input voltage derating table. 100 80 100 80 Load factor(%) 60 40 20 Load factor(%) 60 40 20 0-20 -10 0 10 20 30 40 50 60 70 80 Ambient Temperature( ) 0 50 60 70 80 90 100 110 120 ~ Input voltage(vdc) 3 / 9

Output Voltage [V] Output Voltage [V] Input Power [W] Efficiency [%] Input Power [mw] EPM1510SJ Datasheet Typical characteristics Ta=25 100 90 80 70 60 50 40 30 20 10 Efficiency DC140V DC340V 80 70 60 50 40 30 20 10 Input power (at no load) 0 0 100 200 300 400 500 600 700 800 900 1000 0 100 150 200 250 300 350 400 450 Output Current [ma] Input Voltage VDC [V] 16.0 15.5 Load regulation DC140V DC340V 1.0 0.9 0.8 0.7 Input power (at light load) 0.6 15.0 0.5 14.5 0.4 0.3 0.2 DC140V DC340V 0.1 14.0 0 100 200 300 400 500 600 700 800 900 1000 0.0 0 5 10 15 20 25 30 35 40 45 50 Output Current [ma] Output Current [ma] 16.0 Line regulation No load (0A) 15.5 Rated load (1A) 15.0 14.5 14.0 100 150 200 250 300 350 400 450 Input Voltage VDC [V] 4 / 9

Outline dimensional drawing Unit:mm 5 / 9

Recommended hole diameter and land size The round pulling out figure is a pin numbering. Component side Unit:mm Terminal function and connection Secondaries Pin No. Name Explanation of terminals 1 2 3 4 SecW No terminal No terminal No terminal Non-contact terminal Don't connect with other circuits. Output terminal (+) 5 +DC OUT 6 Non-contact terminal Don't connect with other circuits. Output terminal (-) 7 -DC OUT Primaries Pin No. Name Explanation of terminals 8 9 VccW 10 -DC IN Non-contact terminal Non-contact terminal DC voltage input terminal (-) Don't connect with other circuits. Don't connect with other circuits. 11 Vcc 12 +DC IN 13 14 Drain Terminal for start-up time adjustment DC voltage input terminal (+) No terminal Terminal for noise adjustment 6 / 9

Application circuit example EPM module AC85V~AC276V (50/60Hz) 14 Drain L F101 L101 D101 12 +DC IN C101 C102 11 Vcc SecW 4 N 10 -DC IN +DC OUT 5 L201 +DC OUT 9 VccW 6 C201 C202 -DC OUT 7 -DC OUT 8 C103 Symbol Description Part No. Manufacturer D101 Diode D2SB60 SHINDENGEN L101 Inductor LF-4Z-E363H KORIN L201 Inductor PJ5H-2R2M KORIN C101 Capacitor LE104-MX OKAYA C102 Capacitor 450BXC47M RUBYCON C103 Capacitor CD70ZU2GA102M TDK C201 Capacitor 25ZLG330M RUBYCON C202 Capacitor 25ZLG330M RUBYCON F101 Fuse FIH 250V 1.6A NIPPON-SEISEN Mount the fuse on the input Live side to ensure safety without fail. Recommended parts:fih 250V 1.6A~2.5A/NIPPON-SEISEN Depend on the applying safety standard, please add the discharge resistance in paralell with C101. 7 / 9

Usage cautions Always mount fuse on the Live side of input for ensuring safety because the fuse is not built-in the product. Please select the fuse considering conditions such as steady current, inrush current, and ambient temperature at your own responsib Recommended parts: FIH 250V 1.6A~2.5A / NIPPON-SEISEN When using a fuse having large rated current or high capacity input electrolytic condenser, by combining another converter and input line and input electrolytic condenser, fuse may not blow off in the case of abnormality. Do not combine high voltage line and fuse. Important notice The content of this document is subject to change without prior notice for the purpose of improvements, etc. Ensure that you are in possession of the most up-to-date information when using this product. The operation examples and circuit examples shown in this document are for reference purposes only, and TAMURA Corporation disclaims all responsibility for any violations of industrial property rights, intellectual property rights and any other rights owned by TAMURA Corporation or third parties that these may entail. The circuit examples and part constants listed in this document are provided as reference for the verification of characteristics. You are to perform design, verification, and judgment at your own responsibility, taking into account the various conditions. TAMURA Corporation constantly strives to improve quality and reliability, but malfunction or failures are bound to occur with some probability in power products. To ensure that failures do not cause accidents resulting in injury or death, fire accidents, social damage, and so on, you are to thoroughly verify the safety of their designs in devices and/or systems, at your own responsibility. This product is intended for use in consumer electronics (electric home appliances, business equipment, Information equipment, communication terminal equipment, measuring devices, and so on.) If considering use of this product in equipment or devices that require high reliability (medical devices, transportation equipment, traffic signal control equipment, fire and crime prevention equipment, aeronautics and space devices, nuclear power control, fuel control, in-vehicle equipment, safety devices, and so on), please consult a TAMURA sales representative in advance. Do not use this product for such applications without written permission from TAMURA Corporation. This product is intended for use in environments where consumer electronics are commonly used. It is not designed for use in special environments such as listed below, and if such use is considered, you are to perform thorough safety and reliability checks at your own responsibility. Use in liquids such as water, oil, chemical solutions, or organic solvents, and use in locations where the product will be exposed to such liquids. Use that involves exposure to direct sunlight, outdoor exposure, or dusty conditions. Use in locations where corrosive gases such as salt air, C12, H2S, NH3, SO2, or NO2, are present. Use in environments with strong static electricity or electromagnetic radiation. Use that involves placing inflammable material next to the product. Use of this product either sealed with a resin filling or coated with resin. Use of water or a water soluble detergent for flux cleaning. Use in locations where condensation is liable to occur. This product is not designed to resist radiation. This product is not designed to be connected in parallel. Do not operate this product in a parallel, or N+1 redundant configuration. 8 / 9

Do not use or otherwise make available the TAMURA products or the technology described in this document for any military purposes, including without limitation, for the design, development, use, stockpiling or manufacturing of mass destruction weapons (e.g. nuclear, chemical, or biological weapons or missile technology products). When exporting and re-exporting the products or technology described in this document, you should comply with the applicable export control laws and regulations and follow the procedures required by such laws and regulations including, without limitation, Japan -Foreign Exchange and Foreign Trade Control Law and U.S.- Export Administration Regulations. The TAMURA products and related technology should not be used for or incorporated into any products or systems whose manufacture, use, or sale is prohibited under any applicable domestic or foreign laws or regulations. Please contact your TAMURA sales office for details as to environmental matters such as the RoHS compatibility of product. Please use TAMURA products in compliance with all applicable laws and regulations that regulate the inclusion or use of controlled substances, including without limitation, the EU RoHS Directive. TAMURA assumes no liability for damages or losses occurring as a result of your noncompliance with applicable laws and regulations. TAMURA assumes no liability for damages or losses incurred by you or third parties as a result of unauthorized use of TAMURA products. This document and any information herein may not be reproduced in whole or in part without prior written permission from TAMURA. 9 / 9