International Journal of Advance Engineering and Research Development. Automatic Power Factor Correction in EHV System

Similar documents
ELG4125: Flexible AC Transmission Systems (FACTS)

Paper ID: EE19 SIMULATION OF REAL AND REACTIVE POWER FLOW ASSESSMENT WITH FACTS CONNECTED TO A SINGLE TRANSMISSION LINE

International Journal of Advance Research in Engineering, Science & Technology

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Implementation of FC-TCR for Reactive Power Control

IJRASET 2013: All Rights are Reserved

POWER FACTOR CORRECTION USING SHUNT COMPENSATION

Reactive Power Management Using TSC-TCR

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Reactive Power Compensation by Innovative TSC-TCR type SVC Controller

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Microcontroller Based Power Factor Correction Using SCR

International Journal of Emerging Technology and Innovative Engineering Volume 2, Issue 4, April 2016 (ISSN: )

ABB n.v Power Quality in LV installations

Performance of FACTS Devices for Power System Stability

Supercapacitor Based Power Conditioning System for Power Quality Improvement in Industries

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Overview of Flexible AC Transmission Systems

Enhancement of Power System Stability Using Thyristor Controlled Series Compensator (TCSC)

An Overview of Facts Devices used for Reactive Power Compensation Techniques

A Review on Reactive Power Compensation Technologies

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

American Journal of Science, Engineering and Technology

Okelola, M. O. Department of Electronic & Electrical Engineering, Ladoke Akintola University of Technology, P.M.B. 4000, Ogbomoso, Nigeria

Modeling and Simulation of TSR-based SVC on Voltage Regulation for Three-Bus System

Electrical Power Electric power electrical electric power Electric power electric electric

Power Factor Correction

Recent Trends in Real and Reactive Power flow Control with SVC and STATCOM Controller for transmission line

Maintaining Voltage Stability in Power System using FACTS Devices

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

Induction Generator: Excitation & Voltage Regulation

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Technical News. Power Factor Correction. What technology is best for you? Specialists in electrical and automation products, systems and solutions

Improving Voltage of Grid Connected to Wind Farm using Static VAR Compensator

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

SIMULATION ANALYSIS OF STATIC VAR COMPENSATOR BASED ON THE MATLAB/SIMLINK

IMPROVING VOLTAGE PROFILE OF A GRID, CONNECTED TO WIND FARM USING STATIC VAR COMPENSATOR

TRANSMISSION LOSS MINIMIZATION USING ADVANCED UNIFIED POWER FLOW CONTROLLER (UPFC)

Implementation SVC and TCSC to Improvement the Efficacy of Diyala Electric Network (132 kv).

Systematic Survey for Role of Reactive Power Compensating Devices in Power System

Is Uncorrected Power Factor Costing You Money?

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System

International Journal of Advance Engineering and Research Development

Power Factor Improvement Using Automatic Power Factor Compensation (APFC) Device for Medical Industries in Malaysia

Tiruchengode, Tamil Nadu, India

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

Recent Trades in Distribution System

Chapter 3.1: Electrical System

COMPARISON OF STATCOM AND TCSC ON VOLTAGE STABILITY USING MLP INDEX

DYNACOMP. The top-class reactive power compensator

Alternator as a voltage Generating source and its response to the leading power factor loads

Statcom Operation for Wind Power Generator with Improved Transient Stability

Design and Simulation of Grid Connected PV System

Power Factor Correction

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Dynamic Reactive Power Control. By V. R. Kanetkar Full Time Consultant Technical Services at Veretiv Energy Private Limited Thane (West)

Eskisehir Light Train- Correcting Capacitive

VARIABLE FREQUENCY DRIVE AND ITS INDUSTRIAL APPLICATIONS

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

Comprehensive Analysis of Slip Power Recovery Scheme

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

Real And Reactive Power Saving In Three Phase Induction Machine Using Star-Delta Switching Schemes

Study and Measure the Active and Reactive Power Developed By a Three Phase Induction Generator with Capacitive Load

TECHNICAL TERMS AND ABBREVIATIONS

International Conference on Emanations in Mordern Engineering Science & Management (ICEMESM-2018)

Pump ED 101. Power Factor (Part 2) - - Electricity Behaving Better

Enhancement of voltage profile for IEEE-14 Bus System by Using STATIC-VAR Compensation (SVC) when Subjected to Various Changes in Load

Concepts of Reactive Power Control and Voltage Stability Methods in Power System Network

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

POWER FACTOR IMPROVEMENT CONCEPT FOR LARGE MOTORS

Analysis of Grid Connected Solar Farm in ETAP Software

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation

White Paper Load Banks for Power System Testing

STATIC VAR COMPENSATION FOR SINGLE PHASE INDUCTION MOTOR OPERATION

PQC - STATCON The ultra fast Power Quality Compensator

Improving Power System Transient Stability by using Facts Devices

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Electrical Power System A Review

POSSIBILITIES OF POWER FLOWS CONTROL

A Comparative Analysis of Speed Control Techniques of Dc Motor Based on Thyristors

ABSTRACT I. INTRODUCTION. Nimish Suchak, VinodKumar Chavada, Bhaveshkumar Shah, Sandip Parmar, Vishal Harsoda

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Benefits of HVDC and FACTS Devices Applied in Power Systems

THE METHODS OF REACTIVE POWER COMPENSATION IN THE 25 kv, 50 Hz CONTACT NETWORK

BIDIRECTIONAL FULL-BRIDGE DC-DC CONVERTER WITH FLYBACK SNUBBER FOR PHOTOVOLTAIC APPLICATIONS

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators,

Transcription:

Scientific Journal of Impact Factor(SJIF): 3.134 e-issn(o): 2348-4470 p-issn(p): 2348-6406 International Journal of Advance Engineering and Research Development Volume 2,Issue 5, May -2015 Automatic Power Factor Correction in EHV System Bhavin Seta 1, Prof. Deepa Karvat 2 1 StudentElectrical,P.I.E.T 2 Asst. Prof. Electrical, P.I.E.T Abstract This paper investigates the power factor correction of electrical loads is a problem common to all industrial companies. Earlier the power factor correction adjusting by capacitor manually. The power factor correction equipment are different type. Such as, Synchronous Alternator, Synchronous Compensator, Static var Compensator, Banks of Static Capacitors. The Static capacitors are give up the reactive power in the system. Whereas the variation in load to the different Static capacitor are used. The power factor is a ratio of the actual power to the app arent power. And the Reactive Power is very useful in the power system. Because the inductive load is used in power system and the system is absorbed the reactive power. The designing auto-adjustable power factor correction is to ensure the power factor unity. Keywords- Capacitor, Power factor, Phase Angle, Power System Load, Equipment of Power Factor Angle I. INTRODUCTION Power factor is a ratio of active or usable power measure in kilowatts (KW) to the total power measured in kilovolt amperes (KVA). the cosine of angle between Voltage and Current in A.C Circuit is Known As power factor. the power factor value is very from 1% to 100%, here 100% is called the unity power factor. and the 1% means all the power supplied as a reactive power. The improvement in power factor, first the process of the energy stored in capacitors and inductive devices. As the voltage in the A.C circuits are very from zero to maximum voltage. during starting time the inductive devices are gives up energy from its electromagnetic field, and capacitors are stored energy in the electrostatic field. as the maximum point the voltage is in decreasing condition. at the time capacitors gives up energy and inductive devices stored energy. the capacitors may be considered as a kilovolt amp- reactive (KVAR) generator. the concept of the capacitors as a kilovolt amp-reactive (KVAR) generator is helpful in power factor improvement. Apparent Power(KW): Where V= phase to phase Voltage I= line current. Active Power(KVA): S=V I---(1 ) Eq. 1 S= 3 V I---(3 ) Eq. 2 Eq. 3 So, The Power Factor(cos ): Eq. 4 Eq. 5 Where, S = Apparent Power P = Active Power. The power factor angle is Shown in the Fig 1. @IJAERD-2015, All rights Reserved 762

POWER FACTOR: Fig. 1 Power Triangle In alternating current circuits, the current absorbed by a load can be represented by a two components: 1. Active Component(IR): 2. Reactive Component(IQ): In the most common case, the ohmic-inductive load is present. so, the total current I lags with respect to the active component. the power factor cos is a ratio between the active component IR and total current I, is the phase angle between the voltage and current. Where, P= Active Power Q= Reactive Power Phase angle( ):- ACTIVE POW ER: REACTIVE POW ER: cos = (I R /I) = P/S Eq. 6 =cos^(-1) (P/S) Eq. 7 Here, P=S cos Eq. 8 Q=S sin Eq. 9 Q/P= tan Eq. 10 X L =2πfL Eq. 11 Z=R+jX_L Eq. 12 tan =(X L R) Eq. 13 =tan^(-1) (X L R) Eq. 14 P= V I cos ---(1 ) Eq. 15 P= 3 V I cos ---(3 ) Eq. 16 @IJAERD-2014, All rights Reserved 763

Q=V I ( (1-cos^2 ))---(1 ) Eq. 17 Q= 3 V I ( (1-cos^2 ))---(3 ) Eq. 18 Most apparatus connected to the power supply network required not only active power but also certain amount of reactive power. reactive current are maintain the magnetic field of motor and transformer. series inductance in transmission lines also consumes reactive power. inductive circuit also required a reactive power. reactive power generated by a rotating compensator or capacitors. II. POWER FACTOR CORRECTION The low power factor is mainly due to the effect of the power loads are inductive load, it takes lagging current s. the improvement in power factor some loads are connected in parallel with the load. one of such device is capacitors. It takes leading current. POWER FACTOR CORRECTION EQUIPMENT: 1) Synchronous Alternator: 2) Synchronous Compensator (SC): 3) Static Var Compensators (SVC): 4) Banks Of Static Capacitors: 1) Synchronous alternator: Synchronous alternators are used for the generation of electrical energy. they are supplied electrical power to the final loads through transmission and distribution systems. It is als o very the generated voltage and consequently the regulate reactive power without the change in a technical data. 2) Synchronous Compensators: This Devices are Used in Nodes of the Power Transmission and Sub-Transmission network for the Regulation of Voltage and Reactive Power Flows. Synchronous Compensator are not Used in the Power Distribution Network. Because, their higher installation and Maintenance cost also high. 3) Static Var Compensator: Development Of Power Electronics in replacement of Synchronous Compensator With Static System for the Control of Reactive Power Such as, 1. TSC- Thyristor Switch Capacitors 2. TCR- Thyristor Controlled Reactors The Upper Compensators are Reactive Power Compensator Based on The Electromechanical Components. In Which Co mpensators, The Switching of the capacitors are not used to Opening and Closing of the Contactors, But Control by The Anti-parallel Thyristors. TSC is a Step by Step Control of reactive Power Delivered by the Groups of Capacitors. And TCR is a Continuous Control of reactive Power Drawn By the Inductor is Possible. These Devices are Used in the High and Very High Voltage networks. 4) Banks Of Static Capacitors: The Capacitor is a Passive Dipole Consisting of Two conducting Surface Called Plates, Isolated From One to Another Through A Dielectric Materials. The Last generation of capacitors are dry types and improve their electrical characteristics using specific treatment. No risk of pollution in a dry type capacitors. when the alternating voltage is applied across the plates of capacitors, the capacitor is subjected to charge and discharge cycles. when the capacitor is in charging mode than the reactive energy stored. the capacitor is in discharging mode than the inject such energy in the circuit to which is connected. Capacitor energy equation such as, Eq. 35 Where, E c = Capacitor energy C = Capacitance V = Applied Voltage Because of their Capability of storing and delivering energy, Capacitors are used as a power factor correction banks. and reactive power in the static device as a capacitors banks are used. @IJAERD-2014, All rights Reserved 764

III. SIMULATION AND RES ULT Fig. 1 Three Phase Bus System Fig. 2 Secondary Side Phase Angle Fig. 3 Capacitor Banks @IJAERD-2014, All rights Reserved 765

Fig. 3 Ideal S witch @IJAERD-2014, All rights Reserved 766

CONCLUS ION: From the simulation result, I conclude that the Power Factor Angle is very useful in the Power System and which is measured by the Phase Difference of the Voltage & Current. The Output Waveform of the Phase Angle to the Switch is connected, because the Two value Compared By the Switch. The Individual Switch Output is Connected to the Individual Capacitor Bank Also. So, the Automatic Power Factor Correction are Use in this Waveform. REFERENCES [1] ABB "Power factor correction and harmonic filtering in electrical plants". [2] Mr.A Kumar Tiwari, Mrs. Durga Sharma, Mr. Vijay Kumar Sharma " Automatic Power Factor Correction Using Capacitive Bank " Int. Journal of Engineering Research and Applications www.ijera.com ISSN : 2248-9622, Vol. 4, Issue 2( Version 1), February 2014, pp.393-395. [3] Thomas M. Blooming, P.E, Daniel J. Carnovale, P.E " Capacitor Application Issues" IEEE. [4] Md. Raju Ahmed, M. J. Alam " Power Factor Improvement by Pulse Width Modulated Switched Single Capacitor" Proceedings of India International Conference on Power Electronics 2006 [5] "Guide To Reactive Power Compensation With Capacitors" High voltage technology. [6] T. W. Schroeder, W. C. Bloomquist "Automatic Control and Switching Equipment for Capacitor Banks and Its Application" AIEE. [7] M. H. Shwehdi, M. R Sultan "Power Factor Correction Capacitors; Essentials and Cautions". @IJAERD-2014, All rights Reserved 767