HV/LV Memo. ECE 492 Spring Abstract. Latest Revision: 16 May Prepared by: Brendan Flood

Similar documents
Abstract. Acceptance Test Plan Draft - TSV 1

Abstract. GLV Systems Test Plan 1

Scrutineer name: Start time: End time: The ESO will be the central team contact during Electrical Ask for the ESO

Acceptance Test Report

TECHNICAL INSPECTION SHEET

Maintainability Report

The international electrical symbol consisting of a red spark on a white-edged blue triangle must be affixed in close proximity to each switch.

2015 Formula Hybrid Electrical System Form (ESF)

2016 FSAE ELECTRIC INSPECTION SHEET

2019 Formula SAE Japan Local Rules Number 1 Issued: December 26, 2018(Second Edition)

PRELIMINARY DESIGN REVIEW. LFEV-ESCM-2014 February 13, 2014

Contents. Formula Student UK Appendix FSUK-C-2

PacMan BoB QA Test Plan

Xtalin Accumulator Monitoring System and. Xtalin Accumulator Balancing System devices

Electrical System Form FSAE-E2013 University of California, San Diego Triton Racing Car: E215

Formula Hybrid 2011 Preliminary Electrical Inspection

Formula Hybrid 2015 Electrical Inspection

UCEM High Voltage Battery Design for Electric Vehicle

OICA Draft Proposal for the ELSA Meeting July in Bonn

Abstract. GLV Systems PDR 1

Formula Hybrid ESF -- Part 1

Lithium Power Pack LITHIUM-ION BATTERY SYSTEM. With epro Plus Battery Monitor

LinkPro High Voltage Adapter Installation and Wiring Guide. Initial Release 01/14/10 Rev 1.0

UCEM Tractive Accumulator System. ECE 4901 Senior Design I

RU BMS Power Supply and Battery Management System Owners Guide

Technical Regulations 2019

Connecting other lithium systems to Multis and Quattros

CHAPTER 19 DC Circuits Units

APPLICATION NOTE. Conext Solar Charge Controllers: Ground Fault Protection. Document Number: AU-1.0. Exclusion for Documentation.

SUBSTATION EQUIPMENT - Page 1 of 8

Design Standard. Purpose: Design Standard:

ELECTRICAL INTERFACE TO DC BRUSHLESS MOTORS SUPPLIED IN TECNADYNE THRUSTERS, LINEAR & ROTARY ACTUATORS & HPU s

Photovoltaic Solar Plan Review

INSTALLATION INSTRUCTIONS

Line Gard. Underwriters Laboratories (UL) Applicable Code Notation

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Three-Phase Pole Mounted Recloser

User's Manual O

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

GeePower Energy Technology Co., Limited

4 x 0-10Vdc Channels Fused 24V o/p terminals for actuator power Direct or buffered output signals

Why Orion BMS Internal Fuses Blow

Sonnenschein Lithium HC (High Current)

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-4800 BBS-4800E

XLR Energy Storage Module

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Quik-Spec Coordination Panelboard Specifications

AT30 SERIES BATTERY CHARGER

A3Z OPERATING MANUAL

Spring Reinforced. 30A & 60A Box. Spring. 30A Screw (R) Spring. 30A Screw. Spring Reinforced. 30A Pressure Plate

SECTION DC POWER SUPPLY/BATTERY CHARGER

SPECIFICATIONS NB SKILLS TRADE 19 AUTOMATION AND CONTROL

EV Power - A-Series 8 Cell, 16 Cell and 24Cell Chargers Installation & Usage Instructions.

C&D VRLA Batteries Extended Run Time for Small UPS Machines

ARAI Date of hosting on website: 27 th October 2015 Last date for comments: 27 th November 2015

HARDWIRE VS. WIRELESS FAILSAFE CONTROL SYSTEM. The answer is No.

GFS - New Charging Technology

A6Z OPERATING MANUAL

AF series contactors (9 2650)

Vigilant Automatic Transfer Switches

Contents. DX Ignition Page 2

EV Power - Battery Control Unit Instructions. 8 Cell 24V

Class T 300 & 600 Volt Fuse Blocks F B 300 & 600V CLASS T FUSE BLOCKS RATINGS: FEATURES/BENEFITS: RECOMMENDED FUSE USAGE: CLIP & CONNECTOR TYPES

BMS16 v cell Lithium Battery Management System

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

ATevo SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Chapter 16. This chapter defines the specific provisions regarding type-approval of hybrid electric vehicles.

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

BOOST POWER 1212 Product Description

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

AT EVO SERIES BATTERY CHARGER

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Specification of Battery Charger

2016 Photovoltaic Solar System Plan Review List

Implementation of low inductive strip line concept for symmetric switching in a new high power module

IMPORTANT - Present the vehicle for inspection in the following order:

SDM72 Start on Demand Modules

DH50 SERIES. DATASHEET Rev. A

WARREN COUNTY, N.Y. M/E REFERENCE

MINE CHARGER INSTALLATION AND OPERATION MANUAL MODEL NUMBERS: MSP MSQ MSR MSS

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

EVS RP6020. Instruction Manual

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

National Electric Transportation. Meeting

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Manual. Lynx Ion 24V/180Ah Lithium Ion Batteries

Electricity MR. BANKS 8 TH GRADE SCIENCE

HousePower BMS. CleanPowerAuto LLC

TE S GLOBAL REACH $13.3B sales worldwide Figures shown are fiscal year 2013 sales in billions(b). 2,375 engineers 10 design centers 38 manufacturing s

AF series contactors (9 2650)

GENERAL SPECIFICATIONS

Transcription:

HV/LV Memo ECE 492 Spring 2013 Latest Revision: 16 May 2013 Prepared by: Brendan Flood Abstract This document examines the high-voltage (tractive) and grounded low-voltage systems of the LFEV-ESCM system to prove that they meet Formula Hybrid requirements.

HV/LV MEMO 1 Table of Contents EXECUTIVE SUMMARY 2 INTRODUCTION 2 GALVANIC ISOLATION ENCLOSURES CABLES VOLTAGE, CURRENT, AND ENERGY VOLTAGE LIMITS ENERGY LIMITS VOLTAGE INDICATORS CURRENT PATHS 7

HV/LV MEMO 2 Executive Summary Introduction As a high-energy power system, the LFEV-ESCM contains high-voltage systems that can discharge at currents in excess of 200 amperes. To control this, the high-voltage systems are combined with low-voltage-powered control circuitry. Safety requirements and good engineering practice dictate that high-voltage and low-voltage systems be electrically (galvanically) isolated. This means that the two systems can neither share a current path to ground, nor share a common ground. The analysis presented below shows how the LFEV- ESCM maintains separation between the high-voltage (hereafter HV or tractive) assemblies and the low-voltage (grounded low-voltage or GLV) assemblies. Additionally, the Formula Hybrid competition imposes energy limits on the accumulator system of the vehicle. A quick analysis proves that the LFEV-ESCM s energy storage capacity is within these limits.

HV/LV MEMO 3 Requirements Analysis Voltage and Energy Limits EV1.2.4 The GLV system must be a low-voltage system; see EV1.1.2. In EV1.1.2, a low-voltage system is defined as less than 30VDC. Our system uses a 24-volt Hengfu power supply to power the GLV system, so this requirement passes. EV3.3.3 Maintenance plugs, additional contactors or similar measures must be taken to allow electrical separation of the internal accumulator segments such that the separated segments contain a maximum voltage of less than 120 VDC fully charged and a maximum energy of less than 12 MJ. The separation must affect both poles of the segment. Each separated accumulator segment will contain seven 3.2V, 60Ah cells. When fully charged, the cells reach up to 3.4V open-circuit voltage. This means that the maximum voltage of a fullycharged pack is 23.8V, well under the 120VDC requirement. Also, seven 60Ah cells at 3.4V each, the pack s stored energy can reach up to 1428Wh, which is 5.14MJ. This is less than the 12MJ requirement and passes, as well. Galvanic Isolation EV3.6.5 Any GLV connection to the AMS must be galvanically isolated from the HV. The only GLV connection to the BMS system occurs at the I2C isolator chip, the Analog Devices ADuM1250. This part is UL-rated up to 2500Vrms for 1 minute. It has basic voltage isolation up to 400Vrms and reinforced regulation up to 125Vrms. 1 Since this is the only connection point from the BMS to the GLV system, it passes this requirement.

HV/LV MEMO 4 EV4.1.3 Traction system and GLV circuits must be physically segregated such that they are not run through the same conduit or connector, except for interlock circuit connections. Throughout the system, the HV and LV wiring is separated. The only place where it could be argued is in the charging cable (CW0 on the ICD). This contains the charging positive and negative terminals as well as a safety loop dummy connection. Because the safety loop is an LV system and the charging path carries 25A, some might think this is a concern. However, the cable is designed so that connecting the charger automatically breaks the safety loop, so the discharging path can never be closed while the charger is connected. Also, since the maximum pack voltage is under 30VDC (25.2VDC when charging), the charger is technically not a highvoltage system. All other wiring and cabling clearly separates HV and LV wires. EV4.1.4 GLV circuits must not be present in the accumulator container except for required purposes, for example the AMS and the AIRs. The BMS and the AIRs are the only GLV circuits in the accumulator container, so this requirement is passed. EV4.1.5 Where both tractive system circuits and GLV circuits are present within an enclosure, they must be separated by insulating barriers made of moisture resistant, UL recognized or equivalent insulating materials rated for 150 C or higher (e.g. Nomex based electrical insulation), or maintain the following spacing through air, or over a surface (similar to those defined in UL1741): U < 100 VDC: 1 cm (0.4 inch) This requirement fails on the BMS board but passes on the Load Controller PCB. This has been proven by inspection on the ATR.

HV/LV MEMO 5 EV4.6.4 The tractive and GLV systems must be galvanically isolated. Two points of connection between the tractive and GLV systems exist. One is between the BMS and the high-current path in the pack. As discussed, the BMS is specifically exempt from this requirement. To show that the BMS connection to the pack is safe, we analyze the circuit in Figure 1, shown below. Figure 1 The current path across the terminals of a cell, through the BMS and through the cell An open-circuit resistance measurement of the BMS taken at its voltage measuring points yields about 8 kω. Since the cell s open-circuit resistance is 2 mω, less than one one-millionth of the current through the high-current path flows through the low-current path. Given a short-circuit current draw of about 1000 A, this means that less than 1 ma would go through the BMS board. All on-board components are rated up to this rating, and indeed, the board draws a higher current than this for its normal operation (around 20 ma). The second place of HV/LV connection is the Load Controller. To ensure that separation is maintained, a Bender IR155-3210 Insulation Monitoring Device (IMD) is installed in the Load Controller. Test points from both the tractive and GLV systems connect to this device, which uses a test resistance and current pulses to ensure that the two systems remain separated. Because the competition requires the use of this device, its connection between HV and LV systems is not concerning. Its internal resistance, as rated by the manufacturer, is above 1.2 MΩ, so even if the pack short-circuits across this connection, less than 1 ma would flow.

HV/LV MEMO 6 Voltage Indicators EV3.3.8 The accumulator voltage indicator must be directly controlled by voltage being present at the connectors using hard-wired electronics. (No software control is permitted). Activating the indicator with the control signal which closes the AIRs is not sufficient. The accumulator voltage indicator was not included in the system, and thus this requirement fails. EV4.11.4 The TSAL must not be powered by high voltage. EV4.11.5 The TSAL must be directly controlled by voltage being present at the output of the accumulator and powered by the GLV system (no software control is permitted). Activating the indicator with the control signal which closes the AIRs is not sufficient. The Tractive System Active Light (TSAL) shows when voltage is being applied on the pack side of the isolation relays between the pack and the load. The diagram below shows that the TSAL turns on if full system voltage is applied or if the AIRs are closed. Figure 2 Diagram of the TSAL PCB in the Load Controller

HV/LV MEMO 7 If HV is present on J1, the light (the diode in the middle of the diagram) is powered and turns on. Also, if the control signal to close the AIRs (on J3) is on, this will turn the switch that will also turn on the LED. The switch is an optoisolated switch, thus maintaining separation between the GLV and tractive systems. Current Paths EV4.6.9 Only intentional current paths may be used. Steel may not be used as part of the current path. No plastic in the terminal stack-up. All high-current paths flow through aluminum bars or copper wiring. Some steel bolts are used to fasten aluminum bars together, and during testing it was observed that one bolt (connecting the RelaySideJumper pieces) heated in excess of 60 C when discharging at 360A. Unfortunately, it was too late in the project to properly analyze this joint to see how much current passed through it. There is a similar joint on the other end of the pack connecting a cell terminal to the discharging fuse; it is recommended, in future implementations of the Battery Pack, that the RelaySideJumper with the steel bolt be replaced with a press-fitted bar like the one on the opposite side of the pack to avoid this heating issue.

HV/LV MEMO 8 Appendix A: References 1. Analog Devices ADuM1250, Hot-Swappable Dual I2C Isolator, datasheet: http://www.analog.com/static/imported-files/data_sheets/adum1250_1251.pdf