Uninterruptible Power System

Similar documents
Uninterruptible Power System

Uninterruptible Power System

Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation and Operation Back-UPS BX550CI-CN

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

BRAVER UPS. (Uninterruptible Power System) User s Manual

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Installation and Operation Manual Back-UPS BX1100CI-CN

Back-UPS CS Back-UPS CS 350

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Installation and Operation Manual Back-UPS BR800/1100CI-IN

1. INTRODUCTION. Features:

Informer Compact Series

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

General Precautions. Personnel Precautions

Uninterruptible Power System. Line Interactive Network Protection Pure Sine Wave Output UPS. Rack Mount Models 1000VA/ 1500VA/ 2000VA/ 3000VA

Sola/Hevi-Duty S3K Series Mini-Tower UPS

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

Uninterruptible Power Supply

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

UTILITY INPUT MAINS OUTLET

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

U n i n t e r r u p t i b l e P o w e r S y s t e m

Eclipse Plus VA UPS and Surge Suppressor User s Manual

CP900EPFCLCD User s Manual K

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

661-SK [1]I:\USV_TEAM\USV_MANUAL\Roline\LineSecureII\661-SK [1].d oc U P S. Uninterruptible Power System

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

Thank you for choosing EATON products. Safety information and operating instructions are included in this manual. Do not attempt to operate the UPS

User Manual 1KVA-5KVA INVERTER / CHARGER

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

R series solar charger inverter 1000W to 6000W

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

User Manual Rittal PMC UPS 6kVA

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

Installation and Operation Manual Back-UPS BR1000-CH

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

3000VA 120/208/230VAC

User Manual 1.5KVA-3KVA INVERTER / CHARGER

Uninterruptible Power Supply USER MANUAL Version 1.4. Always On UPS Systems Inc. GES-801L, GES-102L, GES-152L, GES-202L, GES-302L

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Liebert PowerSure PSI UPS

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

USER MANUAL ONLINE UPS

Limousin II User Manual

Foreword

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

USER MANUAL. Uninterruptible power supply MODEL: 53965,

PR1000ELCD / PR1500ELCD User s Manual

LIFT 1500 VA UNINTERRUPTIBLE POWER SUPPLY UPS USER MANUAL

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

User Manual 1KVA-5KVA INVERTER / CHARGER

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Solar Hybrid Inverter SP Brilliant Series

User Manual V1.0 MaxiFlex 3000

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

UPS Wizard User s Manual

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

Solar Hybrid Inverter SP Efecto Series

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

Phoenix Inverter

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

Installation and Operations Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

OPERATIONAL MANUAL .TYPE - ONLINE UNINTTERRUPTIBLE POWER SUPPLY

USER MANUAL. PowerMust 1080 LCD (1KVA), Online, IEC PowerMust 2016 LCD (2KVA), Online, IEC PowerMust 3024 LCD (3KVA), Online, IEC

Foreword. Manual instruction

Sola 3000 Guide Specifications

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

Solar Hybrid Inverter SP Efecto Series

Transcription:

USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible Power System AVR Protection Compact & Reliable Design UPS-7700CR-Rack-01

CONTENTS PAGE 1. CAUTION....1 2. INTRODUCTION SYSTEM DESCRIPTION...2 FEATURES...2 3. SYSTEM CONCEPT BLOCK DIAGRAM...3 NORMAL OPERATION...3 AC UTILITY FAILURE. 4 4. OVERVIEW FRONT PANEL 5 REAL PANEL 6 5. INSTALLATION AND OPERATION 7 6. BATTERY FACTS 8 7. SPECIFICATIONS 9 8. TROUBLE SHOOTING... 10 SPECIFICATIONS Capacity VA 1000VA 2000VA 110VAC, 115VAC, 120VAC, 220VAC, 230VAC or 240VAC Voltage Input -30%, +25% Frequency 50Hz or 60Hz (Auto-sensing) Voltage (Batt. Mode) 110VAC, 115VAC, 120VAC, 220VAC, 230VAC or 240VAC ±10% AC mode: 47-53Hz for 50Hz or 57-63Hz for 60Hz ; Output Frequency Battery mode:50hz or 60Hz +/- 1Hz Waveform Modified sine wave Transfer Time Less than 6ms (typical) Battery Type 12V/7AH *2PCS 12V/9AH *2PCS Battery Recharge Time 5 hours to 90% of full capacity Indicator LCD I/P & O/P Voltage & Frequency, Load %, Battery % Battery Back-up Two short tones every 8 seconds Battery Low Four short tones every second Alarm Overload Beeping continuously Fault Beeping continuously Overload Yes Protection Short Circuit Batt. Low Cut-off AC Fuse and Electronics Circuit (Line mode) ; Electronics Circuit (Back-up mode) No battery drain after cut-off Physical Dimension, D*W*H 337 mm*19 *2U Environment Operating Temperature Noise Level 32-104 at full load, 0~90% relative humidity (non-condensing) Less than 40db (at 1 meter) Interface Contact Closure USB port - 9 -

TROUBLE SHOOTING If the UPS failed to operate properly, please review the following checks firstly. If the problem remains, please consult sales agent for service. Is the Master power switched on? Is the UPS plugged into a correctly working outlet? Is the line voltage within the rating specified? Is the fuse on the rear panel blown? Is the UPS over loaded? Is battery not fully charged? Dead battery? Charger failure? Please provide the following information when call for service. 1. Model number, serial number. 2. Date of the problem occurred, date of purchase. 3. Full description of the problem including load, LCD, and alarm status, installation condition, working environment, etc. Trouble-Shooting Chart Problem Possible Cause Caution To Take IMPORTANT SAFETY INSTRUCTIONS Thank you for selecting this uninterruptible power system (UPS). It provides you with better protection for connected equipment. Please read this manual! This manual provides safety, installation and operating instructions than will help you derive the fullest performance and service life that the UPS has to offer. Please save this manual! It includes important instructions for the safe use of this UPS and for obtaining factory service should the proper operation of the UPS come into question. Please save or recycle the packaging materials! UPS can not turn on LCD not light Battery voltage less than 10VDC PCB failure Load less than 25W at battery mode Recharge the battery Replace the PCB, call for service Normal: No load shutdown function is active The UPS`s shipping materials were designing with great care to provide protection from transportation related damage. There materials are invaluable if you ever have to return the UPS for service. Damage sustained during transit is not covered under the warranty. UPS always at battery mode Power cord lose AC fuse burn out PCB failure Plug in the power cord Replace the AC fuse Replace the PCB, call for service Battery not fully charged Back up time too short Battery defective Recharge the UPS at least 5 hours Recharging the Battery; Call for service Buzzer continuous Overload Remove some loads beeping - 10 -

BATTERY FACTS The battery is the only periodically serviceable parts in the UPS. An expected life is approx. 3 5 years. However, frequent long discharges or ambient temperatures above 80 F will shorten battery life. Therefore, it is recommended to replace the batteries every 3 years after initiating the unit. Recharge batteries every 3 months is necessary if it is not in use because it may cause batteries over-drain. WARNING Only a qualified technician should replace the battery. Batteries have high short-circuit current capacity; mistakes in connecting or disconnecting can cause connections to arc or weld and could cause severe burns. STORAGE The UPS should only be stored if the battery is fully charged. Avoid storage temperatures above 80 F as battery life is significantly shortened. Every 90 days remove the unit from storage and plug it in for 24 hours to recharge the batteries. Batteries may be damaged if left in storage and not recharge every 90 days. IMPORTANT NOTICE Please use same type and same rating of batteries for replacement. Do not replace it with the battery that exceeds specified rating. CAUTION The UPS contains voltages that are potentially hazardous. All repairs should be performed by qualified service personal. The UPS has its own internal energy source (battery). The output receptacles may be alive even when the UPS is not connected to an AC supply. The UPS is suitable for computers and electronic equipment with substantially rectifier or capacitive loads, not suitable for electronic equipment with significant inductive loads, such as motors & fluorescent lamps. Be sure to operate within the power rating of the UPS. Below 1/2 or 1/3 of rated power is recommended for longer backup time & longer battery life. Do not place the UPS near excessive humidity, under sunshine, or close to heat-emitting sources. If the UPS is out of order, please detach power cord and consult your dealer right away. Do not remove cover if there is no serviceable part inside. The unit should be supplied by grounded source. Do not operate the unit without ground source. The socket-outlet should be installed near the equipment and be easily accessible. Do not plug the UPS power cord into itself. That will result in a safety hazard. Installation should be performed by a qualified technician or electrician in accordance with local electrical codes. - 8-1

System Description INTRODUCTION The product is line interactive UPS with LCD display, the newest technology and powerful function. The Line Interactive UPS is designed with 2- steps Boost and 1-step Buck AVR to stabilize input voltage. Input voltage range is -30%, +25% but output regulation is +/-10%. The Line Interactive UPS provides you with the ability of perfect protection of your critical devices. Features Controlled by a technologically advanced microprocessor guaranteeing high reliability Rack / tower convertible design. Equipped with 2-steps boost & 1-step buck AVR to stabilize output voltage Provides lightning, surge, overload, and short-circuit protection. Constant current, constant voltage battery charger (CCCV Battery Charger). UPS will shut down upon battery low ; UPS will restart automatically upon AC recovery (Auto-restart). Built-in DC start function enables UPS to be started without AC power supplied Tel / Modem / Fax / Internet surge suppression. Management software is designed to monitor and control UPS status. Built-in DC start function enables UPS to be started without AC power supplied INSTALLATION AND OPERATION Upon receipt of the UPS, inspect the shipping carton for damage. If there is any obvious damage, immediately report it to the selling dealer or the delivering carrier. If there is no damage to the shipping carton, unpack the unit and inspect the unit for damage. The UPS is designed for installation in a protected environment within a temperature range from 32 F to 104 F and relative humidity of 0 90% without condensation. Do not block inlets and outlets. Install the system in a location free from excessive dust and chemical fumes. Check the identification label to verify the UPS voltage and power rating match the available line voltage and load requirements. Operation: 1. When UPS is connected to city utility, but UPS is not powered on, UPS will charge battery automatically and LCD display will show UPS off. 2. To turn on the UPS unit, press the power On/Off Switch once. To turn off the UPS unit, press the power On/Off Switch again. 3. DC Start. When the UPS is off and there is no power utility, it s still possible to cold start the UPS unit to power the loads 4. When UPS is under battery mode and battery voltage is too high or low, buzzer will beep. 5. Buzzer will beep twice every 8 seconds when city utility is black out. - 2-7

Rear Panel European socket type: SYSTEM CONCEPT The purpose to present this chapter is to give you more precise conception about how UPS works.. 1. Block Diagram INPUT OUTPUT AVR. CHA. INV. Nema 5-15R socket: Fig. 1 shows how UPS works. 1. Outlets 2. AC Input 3. AC breaker 4. Tel / Modem Spike Protection Port: Telecom transfer ports provide users to extend the applications. 5. Communication Interface Port: USB port. 6. Surge Protection Only 7. External Battery Connector (Optional) 2. Normal Operation There are two main loops when AC Utility normal the AC output loop and the battery charging loop. The AC output gets power from AC utility input and pass through AVR to support power to load. In the same time, the AC utility input is converted by AC/DC CHA and support charging power to charge batteries. INPUT OUTPUT AVR. CHA. INV. Fig. 2 shows how the UPS works when AC Utility normal. - 6-3 -

3. AC Utility Failure If AC utility fails, the UPS quickly detects the problem and activates the inverter. The inverter. The DC/AC inverter changes DC power from the batteries into AC and provides continuous uninterruptible power to load. Front Panel 3 OVERVIEW INPUT OUTPUT AVR. CHA. INV. Fig. 3 shows how the UPS works when AC Utility Failure 1 2 1. Master Power Switch: Turn on / off the UPS. 2. UPS test Switch: When UPS is working on AC mode, it also activates the UPS s self-test by press this button. 3. LCD display No. Indication Description 1 Input Voltage Indicate input line voltage value. Input voltage will blink continuously in back up mode 2 Output Voltage Indicate output voltage value. 3 Battery Capacity Estimated battery capacity, the accuracy is influenced by UPS operation mode and load level. 4 Load Level The load level, percentage of full load. 5 Fault FAULT will show up and alarm will beep continuously when UPS in fault condition 6 Alarm mode The audible alarm is enabled. In the back up mode a short touch at the control button will reset the alarm mode. - 4-5