STOCKTROL-H VIBRATING LEVEL SWITCH. Instruction Manual June 2002

Similar documents
P U L S A R point 210

Instruction Manual September milltronics A SERIES

MSI SINGLE IDLER BELT SCALE

MILLTRONICS UNIVERSAL SCALE NIVERSAL SCALE Rev. 1.2

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

Instruction Manual August milltronics MSI BELT SCALE

Instruction Manual August milltronics MMI BELT SCALE

Instruction Manual December milltronics RBSS

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

DIAMOND POINT VIBRATING PROBES

CVR-625. Compact Vibrating Rod Instruction Manual

VLS SERIES Vibration Type Level Sensor

MWL Milltronics Weight Lifter. Instruction Manual June 2001

Vibrating Level Switches for Liquids & Solids HYC-VLS02 Elect. Iss. 02 SIL 2 APPROVED VIBRATING LEVEL SWITCHES FOR LIQUIDS AND SOLIDS

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

ST-H SENSOR. Instruction Manual PL-527 January Rev. 1.6

Instruction Manual May milltronics MWL WEIGHT LIFTER

Rotary Paddle Bin Monitor MODEL KA & KAX

Mobrey dry products level measurement and control

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

Instruction Manual March ile-37 SENSING HEAD

ROTARY Point Level Measurement for Inventory Control

BMRX Series Rotary Level Indicator

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

Soliswitch FTE20. Technical Information. Point level switch for granular solids

Instruction Manual October milltronics MD-36 SPEED SENSOR

ELT SCALE APPLICATIONS

Super-Safe-Plus Roto-Bin-Dicator

Process Protection Motion sensors

MMI-2 2 IDLER BELT SCALE

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

PROCAP Capacitance Level Sensors

BMRX Series ROTARY LEVEL CONTROL

PROCAP Capacitance Level Sensors

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Soliswitch FTE30. Technical Information

ILE-61 SENSING HEAD. Instruction Manual PL-376. November 2001

Level Measurement Point level measurement - Vibrating switches

R F C a p a c i t a n c e TrueCap

Instruction Manual July milltronics MMI BELT SCALE

Motion sensors. Milltronics MFA 4p 6/17. Overview

Level Limit Switch soliphant FTM 930/931/932/ Z

Process Protection Motion sensors

for free flowing solids NIVOROTA ROTARY PADDLE LEVEL SWITCHES LEVEL SWITCHES

ROTARY PADDLE LEVEL SWITCHES

IOM. LP-100 & LP-200 Pulse Point TM Installation & Operation Manual

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

RS85 Vibrating fork level switch

Process Protection Motion sensors

Belt Scales Accessories. Milltronics Test Chain. Operating Instructions 04/2013. Milltronics

Belt Scales. Milltronics MUS Belt Scale. Operating Instructions 06/2012. Milltronics

Just Level. Table of Contents. Model CPH Capacitive Proximity Switch TECHNICAL INFORMATION. Principle of Operation 2. Applications 3.

Level Measurement Point level measurement - Rotation paddle switches

Belt Scales. Milltronics MWL Weight Lifter. Operating Instructions 11/2011. Milltronics

PRO REMOTE Series CAPACITANCE PROBE

BinMaster Price Book

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Screw Lift Conveyor for Efficient Elevation When Your Handling Problem Calls for Elevating Bulk Materials

Installation, Operation & Maintenance Instructions

THE LEADER The Leader IN DRY BULK in LEVEL Dry MEASUREMENT

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

TrueCap RF Capacitance Level Sensor

MSI SINGLE IDLER BELT SCALE

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Model R7 Rotating Paddle Level Sensor Ideal for powders, solids, and granular material

GP Rev a ( ) DCN0533

FICHA TÉCNICA DE PRODUTO

ST-50 SERIES ULTRASONIC TRANSDUCER

Contents R4 1. Capacitive Proximity Sensors

Vertical Screw Elevator

process measurement solutions The dry products level control catalogue

Roto-Bin-Dicator PRO Installation & Operation Manual

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

PRO REMOTE 25 LV CAPACITANCE PROBE

Thermocouple Thermometer Models

AUTOWEIGH FEEDER AUTOWEIGH FEEDER SERIES 1200/3600. Instruction Manual PL Rev. 1.1

Kondunivo Table of contents

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Z4-Series DREXELBROOK DATA SHEET. Easy-Installation. Z-tron IV Point Level Switch, a reliable low-cost, on/off level switch.

Capanivo Series CN 4000

Honeyville Cyclones. Sizes Ranging from 575 CFM to 57,000 CFM

ISO-9001:2000 certified Aplus Finetek Sensor, Inc.

Rosemount 2160 Wireless Vibrating Fork Liquid Level Switch

Instruction Manual September milltronics WEIGHFEEDER 800

Point level measurement Capacitance switches

GP50 Vibrating Fork Level Switch. Vibrating level switch for powders and granular solids K-TEK Products

Industry Product Siloheight Status Chemical ABS pellet 3m good Chemical ABS Powder, PP & PE Pellet etc good Chemical Activated carbon 3m watch out

MSI BELT SCALE APPLICATION GUIDELINES

Mini-Roto TM Paddle Wheel Installation & Operation Manual

INSTALLATION / INSTRUCTION MANUAL

Model 550 Series Vibration Switches

Florham Park, NJ USA Call (ASCO) for sales or service

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

m WARNING! READ m BEFORE INSTALLATION

Bin-Dicator FEATURES AND BENEFITS

The Magiflex Level Control System Installation and Setting up Instructions

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

ABB Instrumentation. Noflote designed for control of conductive liquids. Reliable on/off liquid level control for alarms or pump control

Transcription:

STOCKTROL-H VIBRATING LEVEL SWITCH Instruction Manual June 2002

Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the connected equipment. These warning notices are accompanied by a clarification of the level of caution to be observed. Qualified Personnel This device/system may only be set up and operated in conjunction with this manual. Qualified personnel are only authorized to install and operate this equipment in accordance with established safety practices and standards. Warning: This product can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and maintained. Note: Always use product in accordance with specifications. Copyright Siemens Milltronics Process Instruments Inc. 2002. All Rights Reserved This document is available in bound version and in electronic version. We encourage users to purchase authorized bound manuals, or to view electronic versions as designed and authored by Siemens Milltronics Process Instruments Inc. Siemens Milltronics Process Instruments Inc. will not be responsible for the contents of partial or whole reproductions of either bound or electronic versions. Disclaimer of Liability While we have verified the contents of this manual for agreement with the instrumentation described, variations remain possible. Thus we cannot guarantee full agreement. The contents of this manual are regularly reviewed and corrections are included in subsequent editions. We welcome all suggestions for improvement. Technical data subject to change. MILLTRONICS is a registered trademark of Siemens Milltronics Process Instruments Inc. Contact SMPI Technical Publications at the following address: Technical Publications Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, Ontario, Canada, K9J 7B1 Email: techpubs@milltronics.com For the library of SMPI instruction manuals, visit our Web site: www.siemens-milltronics.com Siemens Milltronics Process Instruments Inc. 2002

INTRINSIC SAFETY WARNING Substitution of components may impair intrinsic safety. This device must be grounded to insure intrinsic safety. AVERTISSEMENT La substitution de composants peut compromettre la sécurité intrinsèque. Mettre ce dispositif à la terre pour en assurer la sécurité intrinsèque. SPECIFICATIONS Power: Enclosure: - 115/230 V, 50/60 Hz, 4 VA - cast aluminum - 3/4" NPT conduit entrance hole Probe: - type S-4-316 stainless steel ( see exceptions ) - 1-1/2" NPT mounting - 1,000 kpa (150 PSI) maximum pressure rating - insertion length: - standard is 203 mm ( 8" ) - extended is 460 mm to 1510 mm (18" to 60" )in 150 mm ( 6" ) increments * dimensions are nominal - assembly: - standard is welded - extended: - threaded ( extension is 304 S.S.or plated steel ) - welded (food grade) Temperature: - electronics: -40 to 40 C (-40 to 105 F) - process material: -40 to 88 C (-40 to 190 F) Minimum Material Density: - 32 kg/m 3 ( 2 lb/ft 3 ) Maximum Pressure: Sensitivity: - 1000 KPa - high or low, jumper selective Relay: - time delay: - 1 sec from loss of vibration - 2 to 5 sec from resumption of vibration - failsafe: - high or low, jumper selective - output: - DPDT (2 form C) contacts, rated at 250 V AC, 5 A Weight: Approvals: - 3.4 kg (7.5 lb) - CSA, FM : see device nameplate PL-301 3 98/04/05

Applications The Stocktrol - H Vibrating Level Switch detects the absence or presence of dry bulk solids in bins, silos and hoppers. It can be mounted to give high or low level alarms. The following list highlights some of the materials that the Stocktrol - H has been successful in monitoring. animal feed coffee beans gravel sawdust beans coffee, ground milk powder soda candies dehydrated mud peanuts spices carbon black fine ground glass polystyrene powder styrofoam pellets cellulose powder flour polystyrene chips sugar cement freeze-dried coffee potato chips tea leaves chalk grains puffed cereals tobacco cereals frozen french fries salt wood shavings clay powder granular plastics sand Operation General The Stocktrol - H is a vibrating level switch that provides a contact output indicating a high or low level in a bin. The signal from the electronic circuit excites a crystal in the probe, causing the blade to vibrate. When material contacts the blade of the probe, the vibration stops. This is sensed by the electronic circuitry which forces the relay to change state after a one second time delay. When the blade is freed, the vibration will resume after a few seconds of time delay and the relay will revert to its normal operating status. The shape of the blade and its vibrating action make it self- cleaning. Relay status LED 1 is illuminated when the relay is energized Sensitivity There are two sensitivity settings that can be selected by the J6 jumper on the circuit board. The A position is normally used first when setting up the Stocktrol-H. If the Stocktrol-H fails to give an alarm, set the jumper to B. The B position is used typically on sticky or relatively dense materials. PL-301 4 98/04/05

Failsafe / Relay The Stocktrol - H operates in either failsafe high (FSH) or failsafe low (FSL). The failsafe mode is selected by the J1 jumper on the circuit board: FSH - for high level alarm, the relay is de-energized ( LED off ) when the blade is in contact with material or power has failed. FSL - for low level alarm, the relay is de-energized ( LED off ) when the blade is free or power has failed. Failsafe operation is achieved by using the normally open contact of the relay in the annunciator or control circuit. F S L status F S H status bin relay LED bin relay LED n.c. n.o. on n.c. n.o. on NORMAL ALARM / FAILURE n.c. n.o. off n.c. n.o. off Installation The Stocktrol - H standard insertion length is normally screwed into the bin wall at the level to be monitored. The probe must be kept out of the path of falling material so as not to be damaged. If this is not possible, a shield must be constructed over the probe as shown. A shield must also be used when the Stocktrol - H is used for low level indication. gasket mounting flange angle iron bin wall PL-301 5

The extended version is designed for top mounting, whereby the probe is suspended vertically such that the blade will reach into the material at its maximum level. In cases where the extended probe is installed horizontally and a shield is required, it should be extended and adequately supported, over the length of the probe. THE MAXIMUM VERTICAL FORCE ON THE BLADE IS 20 N m (15 FT LB). When the probe is inserted horizontally, it must be turned until the blade is vertically oriented. This reduces the chance of material resting on the blade, causing false alarms. Alignment of the blade is verified by the two slots in the mounting gland nut. These will be facing up and down when the blade is vertically oriented. When screwing the Stocktrol - H into the bin, use a wrench on the mounting gland nut. CONDUIT ENTRY SHOULD BE FROM THE BOTTOM TO AVOID ACCUMULATION OF CONDENSATE IN THE ENCLO- SURE. DO NOT SCREW BY TURNING THE HOUSING. slot mounting gland nut PLAN VIEW - horizontal installation note : slot signifies orientation of blade tank wall SIDE VIEW - horizontal installation PL-301 6

LAYOUT AND CONNECTION All wiring must be done in conjunction with approved conduit, boxes and fittings and to procedures in accordance with all governing regulations. Field wiring must be on terminal block side only to maintain intrinsic safety. relay shown in de-energized condition relay status LED alarm jumper power connection relay connection (dry contacts) sensitivity jumper connection to probe component view side view terminal block view Notes : COM. = common or ground N.C. = normally closed N.O. = normally opened PL-301 7 98/04/05

STOCKTROL - H OUTLINE 25 mm (1") 104 mm (4.1") 51 mm (2") blade 100 mm ( 3.95" ) 1-1/2" NPT mounting 183 mm (7.2") 305 mm (12") approx. 3/4" NPT conduit entrance STANDARD probe 203 mm (8") approx. 25 mm (1") 104 mm (4.1") 51 mm (2") 1-1/2" NPT mounting blade 100 mm ( 3.95" ) 183 mm (7.2") 267 mm (10.5") approx. 3/4" NPT conduit entrance EXTENDED WELDED probe nominal insertion length ** ( see sizes below ) 25 mm (1") 104 mm (4.1") 51 mm (2") threaded extension * 1-1/2" NPT mounting blade 100 mm ( 3.95" ) 183 mm (7.2") * Threaded Extension 267 mm (10.5") approx. 3/4" NPT conduit entrance EXTENDED THREADED probe nominal insertion length ** ( see sizes below ) Supplied and assembled by Milltronics - 1" NPT schedule 80, 304 S.S. or plated steel. Refer to original equipment order. ** Nominal Insertion Length mm 460 610 760 910 1060 1210 1360 1510 inches 18 24 30 36 42 48 54 60 PL-301 8

PL-301 9 98/04/05 SCHEMATIC Stocktrol - H with S-4 probe Switch settings are typical. Refer to Operation for details. ref. 10D763

Siemens Milltronics Process Instruments Inc. 1954 Technology Drive, P.O. Box 4225 Peterborough, ON.Canada K9J 7B1 Tel: (705) 745-2431 Fax: (705) 741-0466 www.milltronics.com c Siemens Milltronics Process Instruments Inc. 2002 Subject to change without prior notice *7ml19981fk01* Printed in Canada Rev. 1.0