No. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.

Similar documents
FITEL S153A Ver.2 Hand-held Active Alignment Splicer

S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

Tools. Features. KIT Installer tool

All In One Fusion Splicer

Reasons for reissue of this instruction sheet are provided in Section 8, REVISION SUMMARY.

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900 µm Instructions

OPTICAL FIBER FUSION SPLICER

3M No Polish Connector 8800-APC/AS SM SC/APC, Angle Splice, 250/900-µm. Instructions. October C

Crimp & Cleave Termination Instructions

Optical Fusion Splicer

Instruction Sheet Simplex and Duplex. LightCrimp Plus LC. Fiber Optic Connector Kits Feb 2017 Rev E

CORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL

3M No Polish LC/APC Connector SM, Angle Splice, 250/900 µm 8830-APC/AS

Crimp & Cleave Termination Instructions

Optical Fusion Splicer AbsySplicer-AV6472 ABSYS S.A.

Verizon FTTP Tool Kits and Accessories An Evolant Solutions Product

3M No Polish LC Connector SM and MM, Flat Splice, 250/900 µm

FOSCHF Horizontal Fiber Optic Splice Closure

SNP-8 Series Single mode FC CONNECTOR PLUG - for Angled-PC, Conical Shape -

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

OFS-80. Optical Fiber Fusion Splicer. User s Manual

LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

FAST-SC Connector. Any questions should be directed to AFL Telecommunications.

THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.

OFS Assembly Instructions Instruction Sheet for LC Comcode: Fiber Optic Behind-The-Wall (BTW) Connectors

Universal Splice Tray Installation Instructions

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

INSTALLATION INSTRUCTIONS

MIL-PRF type fiber optic termini F722 - F724

Horizontal Fiber Optic Splice Closure (FOSC) Installation Manual

Table of Contents. Type 65 Micro-Mass Fusion Splicer

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

Hand Tools and Accessories for AMP NETCONNECT

INSTALLATION INSTRUCTIONS

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

COYOTE Terminal Dome Closure 6.5" x 22"

Fiber Connector Shelf (CCS)

FIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf

PTR-200 SERIES FIBER RECOATERS AND PROOF TESTERS. A Complete Series of Products for Coating Restoration and Reliability Testing

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

SJOF-BS604A Fiber Optic Splice Closure User Manual Rev.0

Instruction Manual SAT-17T OPTICAL FUSION SPLICER

Patching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

INSTRUCTION MANUAL 910FS

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

MAINTENANCE MANUAL ARC FUSION SPLICER FSM 40S LEVEL 2

FIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails

OFS-935C. Fusion Splicer. Operation Guide

COYOTE LCC (Low Count Closure)

Terminator DP/FAK-5 and FAK-5L

Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Fiber Optic Splice Module

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

Fiber optic splice closure

Environmental Distribution Center (EDC-06P-NH)

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

P/N: , Rev-E, 14/07/2016 Modified on 07/ V/60Hz

HSC-O1. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC)

C Power Connection Kit

Volition. VF-45 Quick Install kit. and Maintenance Cleaning Kit. 3Innovation

INSTALLATION INSTRUCTIONS

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

SNR-FOSC-D. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-D. Installation Manual

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

SNR-FOSC-F. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-F. Installation Manual

The Sumitomo Type-37 Micro-Core Fusion Splicer GUIDE TO OPERATION

Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) OT-8903-AE. Installation Manual

ZDVP-740 Máquina de Fusão Ótica. Introduction

SNR-FOSC-H. Dome Mechanical Seal Fiber Optic Splice Closure. Dome Mechanical Seal Fiber Optic Splice Closure (FOSC) SNR-FOSC-H. Installation Manual

Fiber Splice Panel Rack Mount User Manual

Tender for procurement of Passive Components of LAN & Wi-Fi and their installation. Corrigenda. Annexure/Clause For Read

B1-OPCL Installation Manual

OPTICAL FIBER CLOSURE

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Horizontal Fiber Optic Splice Closure (FOSC) FOSC-GPJ-A024. Installation Manual

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

System Date of Issue Bulletin Number Bulletin Type. Title: Elimination of AC Connectors J29a and J29b

Backside License Plate Mount for Jeep JK Wrangler

FiberConnect Bare Fiber Adapter. nrit

American Standard ProAx Triaxial Camera Connectors Installation Instructions

Chengdu Qianhong Communication Co., Ltd. Fiber Optic Splice Closure. GJS03-M8AX-JX-144D-Mechnical Sealing Way.

8400 Series Fiber Distribution System

MODEL 5500 Tire Repair Station

Bulk Wire. Year Description Part # BLACK PART # RED

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

COYOTE STP (Service Termination Point)

Instructions for Use - Opt-X 1000i Enclosure

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

80703 & Backside License Plate Mount for Jeep JK Wrangler (80707) & 10+ (80703)

SNR-FOSC-D-T. Installation Manual SNR-FOSC-D-T. Dome Heat Shrinkable Seal Fiber Optic Splice Closure (FOSC)

Terminator ZP/FAK-5 and 5L

ORIENTEK T40 Optical Fiber Fusion Splicer. User s Manual

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

Transcription:

TOUCH Plus SC Splice-On Connector for Cordage Standard assembly procedure of TOUCH Plus SC Splice-On Connector is as below. Caution : Wear eye protection glasses when handling optical fibers. 1. Preparation (1) Package (2) Recommended Assembly Tools (3) Heating Parameter #1 #2 #3 #4 #5 No. Parts 1 Nut + Boot Assembly 2 Grip 3 Splice Protection Sleeve 4 Stopper 5 Plug Frame Unit No. Tool Vendor P/N 1-1 Fusion Splicer 1-2 1-3 Holder for 900 μm coating diameter fiber Holder for TOUCH Plus SC SOC 2 Fiber Cleaver 3 Jacket Slitter 4 3-Hole Fiber Stripper 5 Kevlar Scissors S123C, S153A, S178A S712S-900 S712C-SGCH9-R S325A, S326A S240A S211B SS-01 6 Scale any any 7 Marker (oil-based) any any Parameter for heater program on S123C, S153A or S178A for TOUCH Plus SC SOC splice protection sleeve Heat Temp Heat Time 180 deg C 60 sec. 8 Cleaning paper any any 9 Ethanol any any Page 1/6

TOUCH Plus SC Splice-On Connector for Cordage 2. Assembly Procedure (1) Pick up Plug Frame Unit from package and put onto holder. (2) Slide Nut and Boot Assembly onto cable. (3) Measure length of jacket to be stripped and mark at 25mm and 130mm. (4) Strip jacket and kevlar at 25mm. (5) Split jacket lengthways at 130mm. (6) Slide Stopper onto buffer cord. (7) Slide Splice Protection Sleeve onto buffer cord. (8) Measure length of buffer coating to be stripped and mark at 25mm. Page 2/6

TOUCH Plus SC Splice-On Connector for Cordage (9) Strip buffer coating at 25m, and put it onto holder. (10) Cleave fiber. (11) Set holders on splice machine, and splice fibers. (12) Slide Splice Protection Sleeve toward holder, and pick up spliced fiber cord. (13) Put spliced fiber cord onto heating stage. * Note (14) Confirm heating of Splice Protection Sleeve properly made. (15) Slide Stopper to Plug Frame Unit and twist it 90 degree to be assembled. (16) Spread kevlar over the tail of Stopper. (17) Slide Nut and Boot Assembly over kevlar, and screw. (18) Screw Nut and Boot Assembly until it stops. (19) Assemble Grip onto Plug Frame Unit. (20) Assembly completed! Page 3/6

TOUCH Plus SC Splice-On Connector for φ900µm Buffer Cord Standard assembly procedure of TOUCH Plus SC Splice-On Connector is as below. Caution : Wear eye protection glasses, when handling optical fibers. 1. Preparation (1) Package (2) Recommended Assembly Tools (3) Heating Parameter #1 #2 #3 #4 No. Parts 1 Grip 2 Splice Protection Sleeve 3 Boot Assembly 4 Plug Frame Unit No. Tool Vendor P/N 1-1 Fusion Splicer 1-2 1-3 Holder for 900 μm coating diameter fiber Holder for TOUCH Plus SC SOC 2 Fiber Cleaver 3 3-Hole Fiber Stripper S123C, S153A, S178A S712S-900 S712C-SGCH9-R S325A, S326A S211B 4 Scale any any 5 Marker (oil-based) any any 6 Cleaning paper any any Parameter for heater program on S123C, S153A or S178A for TOUCH Plus SC SOC splice protection sleeve Heat Temp Heat Time 180 deg C 60 sec. 7 Ethanol any any Page 4/6

TOUCH Plus SC Splice-On Connector for φ900µm Buffer Cord 2. Assembly Procedure (1) Pick up Plug Frame Unit from package and put onto splice holder. (2) Slide Boot Assembly onto buffer cord. (3) Slide Splice Protection Sleeve onto buffer cord. (4) Measure the length of buffer coating to be stripped and mark at 25mm. (5) Strip the coating of the buffer cord. (6) Put stripped buffer cord onto splice holder. (7) Cleave the fiber. (8) Set holders on splice machine, and splice fibers. (9) Slide Splice Protection Sleeve to tail of Plug Frame Unit, and pick up spliced fiber cord. Page 5/6

TOUCH Plus SC Splice-On Connector for φ900µm Buffer Cord (10) Put spliced fiber cord onto heating stage. * Note (11) Confirm heating of Splice Protection Sleeve was properly made. (12) Slide Boot Assembly to Plug Frame Unit and twist it 90 degree to be fixed. (13) Assembly completed! * Note : Please contact to Electric/ and their representatives for modification of heater on splice machine. Copyright 2013 SEIKOH GIKEN Co., Ltd. www.seikoh-giken.co.jp/en/ Page 6/6