First V84.3A Gas Turbine Installation at Hawthorn Station

Similar documents
Shop Test Result of V64.3 Gas Turbine

Engineering Success by Application of STAR-CCM+ for Modern Gas Turbine Design

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Technology Application to MHPS Large Frame F series Gas Turbine

The Enhanced Platform

Design and Test of Transonic Compressor Rotor with Tandem Cascade

SGT5-8000H/SCC5-8000H 1S. First experience of Commercial Operation at Irsching 4. Russia Power Moscow, March

Industrial RB211 Gzero Gas Turbines

RIKT Isothermal Turbocompressors. With integrated cooling

RIKT 71 Isothermal Turbocompressor

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

New Robotic Technologies for Inspecting Two Pole Electric Generators while the Rotor Remains in Place

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

SGT-2000E gas turbine series

THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E St, New York, N.Y CT-11

SIGENTICS HV Series S-modyn

Generating unit functional document submission form

THE SIEMENS SGT-750 GAS TURBINE: DEVELOPED FOR THE OIL AND GAS INDUSTRYAnders Hellberg Siemens Industrial Turbomachinary S Finspong Sweden

93 MWe natural gas fired Combined Cycle Power Plant

Engineering Success by Application of Star-CCM+ for Modern Gas Turbine Design

Consultant Jim Berry, USA, discusses the ways in which dual driven pipeline compressors can offer flexible and cost-saving operational modes.

World s Largest Air-cooled Turbogenerator in operation

SGT-2000E gas turbine series

The SGT5-8000H proven in commercial operation

Fuse: On-wing engine inspection

Generators for the age of variable power generation

Design specifications

CycloBlower XP Series offers 20 psig continuous pressure and 17 "Hg continuous vacuum.

Power-GEN Middle East

Appendix B6 Gas Turbine Unit Cause Codes

WET COMPRESSION. What it Is Not. What it Is. Is not traditional inlet air cooling, like a fogger or a chiller

Shop Test of the 501F A 150 MW Combustion Turbine

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Operating Results of J-series Gas Turbine and Development of JAC

SGT5-8000H / Irsching 4 Siemens H class gas turbine Pioneering efficiency with world class flexibility

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Engineers Ireland Site Visit 23 rd March 2010

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

(With the possibility of conversion to HFO firing)

Siemens SGT6-5000F Gas Turbine Technology Update

Electrical Machine Service. Overhaul, Conditioning, On-Site Service and Diagnostics. Excellent Technology, Efficiency and Quality

Efficient, dependable and off the shelf. Pre-engineered gas-turbine driven pipeline compressor packages. Answers for energy.

Chapter 9 GAS POWER CYCLES

Development and Performance Evaluation of High-reliability Turbine Generator

9. Examples of hydro energy conversion

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

Modern Design for Variable Speed Motor-Generators:

Investigation of converging slot-hole geometry for film cooling of gas turbine blades

Compact, flexible, highest availability.

The American Society of Mechanical Engineers

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Development of a Gas Turbine Generator On-Board Electric Power Source for MAGLEV Trains

Compact, flexible, highest availability. H-compact PLUS

Peaking plant Bayonne (NJ/USA) A flexible solution to support a volatile grid based on aero-derivative turbines

Electric Drive - Magnetic Suspension Rotorcraft Technologies

Power Generation Services Solutions for challenging Markets

EXPERIENCE OF 29MW SGT-700 GAS TURBINE IN POWER GENERATION APPLICATIONS

PRODUCTS. Multi-Stage Steam Turbines. Proven reliability and efficiency

Making Electricity since December Melody Collis Facilities Engineering Assistant Manager Toyota Motor Manufacturing Canada

THE EFFECT OF BLADE LEAN ON AN AXIAL TURBINE STATOR FLOW HAVING VARIOUS HUB TIP RATIOS. Dr. Edward M Bennett

ALCOHOL LOX STEAM GENERATOR TEST EXPERIENCE

SGT5-8000H - Product Validation at Irsching 4 Test Center. Dr. Roland Fischer Phil Ratliff Willibald Fischer. Siemens AG, Energy Sector Germany / USA

Chapter 6. Supercharging

CycloBlower Industrial Series. Positive Displacement Blowers & Vacuum Pumps

Marine generators Proven generators for reliable power on board

Pressurized Air Cooled Generators

Research on vibration reduction of multiple parallel gear shafts with ISFD

Industrial Steam Turbines. The comprehensive product range from 2 to 250 megawatts. Answers for energy.

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE

Extended requirements on turbogenerators

Balancing and over-speed testing of flexible rotors

Foundations of Thermodynamics and Chemistry. 1 Introduction Preface Model-Building Simulation... 5 References...

Comparing FEM Transfer Matrix Simulated Compressor Plenum Pressure Pulsations to Measured Pressure Pulsations and to CFD Results

Texas Technology Showcase March 2003 Houston, TX

SGT5-2000E Latest Service Improvements for Optimized Operations, Maintenance and LNG Fuel Conversion Upgrade Grit Hennig

APS 2000 Shop Findings Report

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

AGN 076 Alternator Bearings

New Generator Products

THE AMERICAN SOCIETY OF MECHANICAL. ENGINEERS 345 E. 47th St., New York, N.Y

B kv Gas-insulated Substations

XQ-5200 Solar T60 Gas Turbine-Generator 5,200 ekw Iso Conditions 13.8 kv

When should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy

Document Code: 1 (8) Issuing date: Status:

FLAME COOLING AND RESIDENCE TIME EFFECT ON NO x AND CO EMISSION IN A GAS TURBINE COMBUSTOR

GSG Diffuser Style Barrel Pump ISO (API 610) Type BB5

MD High Pressure Stage Casing Pump

MSD Axially Split Multistage Pump

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

POWERING EVERYONE. Unlocking the Potential JULIO MESTRONI, APPLICATION ENGINEERING LEADER

Paper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE

Chapter 9 GAS POWER CYCLES

Unit s 1 & New Berlin Road No.109 Jacksonville, Florida Global Power Generation Services, All Rights Reserved.

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

F-class OpFlex controls advancements

TurboPHASE: Cost- Effective and Efficient Peaking Power

T5S4P3 Synchronous Condensers Application. Mr. Marco Schenone Mr. Sandro Tuscano Mr. Alessandro Oldrati

High Speed Gears - New Developments

Appendix G Examples and Recommended Methods

Transcription:

THE AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47th St., New York, N.Y. 10017 97-GT-357 The Society shall not be responsible for statements or opinions advanced in papers or cgicussion at meetings of the Society or of its Divisions or Sections, or printed In its publications. Discussion Is primed only if the paper is published in an ASME Journal. Authorization to photocopy material for Internal or personal use under circumstance not fang within the fair useprovisions ot Me Copyright Act is granted by ASME to libraries and other users registered with the Copyright Clearance Center (CCC) Transactional Reporting Service provided that the base fee ot S0.30 per page is paid directly to the CCC, 27 Congress Street Salem MA 01970. Requests for special permission or bulk reproduction shadd be addressed to the ASME Technical Publishing Department CcpyrigM 0 1997 by ASME All Rights Reserved. Printed in U.S.A First V84.3A Gas Turbine Installation at Hawthorn Station / T. Johnson B. Becker J. Seume H.Termuehlen Kansas City Power & Light Siemens / KWU Siemens / KWU Siemens Power Corporation Abstract The first V84.3A gas turbine as tested at the full-load test facility of the Siemens gas turbine factory in Berlin, Germany has now been installed at the Kansas City Power & Light ( KCP&L ) Company's Hawthorn Power Station. The unit will be started in spring of this year and is scheduled to be available in June for the 1997 summer peak. In times when active power is not in demand, the generator can be operated as a synchronous condenser. For this mode of operation, a synchronous clutch has been installed between the gas turbine and the generator. The advanced V84.3A gas turbine has been chosen because of its high simple cycle efficiency based on the measured 38% in the test facility, providing peaking capacity with a minimum on fuel costs. In addition, later conversion to highly efficient combined cycle operation can easily be performed without the need for external air or even steam cooling systems. Introduction Hawthorn Power Station History The Hawthorn Power Station became the first large power plant of KCP&L to satisfy the growing demand for electricity in the late 1940's. Located nine miles northeast of downtown Kansas City at the Missouri River, it occupies a 550 acre site. The first two coal-fired steam units #1 and #2 were ordered in 1948. Both 66 MW non-reheat units went into commercial operation in 1951. Further increasing demand for electric power required ordering more efficient reheat steam turbine units in 1950 and 1953 rated at 100 MW each to be available for commercial operation in 1953 and 1955, respectively. In 1965, KCP&L announced their then largest single project by installing a 500 MW reheat steam unit at the Hawthorn Station site. When this unit #5 went into operation in 1969, it increased KCP&L's capacity by 50%. Hawthorn Station V84.3A Gas Turbine Proiect On February 8, 1995 a contract was signed to install the first V84.3A gas turbine at the Hawthorn Station site. After the units #1 through #4 were retired in 1982, unit #5 generated only 450 MW/500 MVA at the Hawthorn site. The demand for more capacity led to an upgrade of the steam cycle of this unit to generate power in excess of 480 MW. During peak demand in the winter and even more in the summertime, unit # 5's maximum capacity was not suffcient and became limited by its generator's apparent power capacity (MVA Rating). Therefore, the decision was made to install a V84.3A gas turbine for supplying additional peaking capacity for about 500 hours per year to cover both the summer and winter peak demand. In addition, a synchronous clutch will allow the gas turbine generator to operate as a synchronous condenser for about two months in the winter and three months in the summertime, producing a maximum of 83 MVAR apparent capacitive power for supporting the system, in particular allowing unit #5 to operate at full-load without its generator limiting the maximum capacity of this unit. Presented at the International Gas Turbine & Aeroengirte Congress & Exhibition Orlando, Florida June 2-June 5,1997

Figure 1. Hawthorn Power Station Layout V84.3A Gas Turbine Site Arrangement With Hawthorn units #1 through #4 being retired but not demolished, selecting the proper arrangement of the gas turbine became important. Shown in Figure 1 is the arrangement of the V84.3A unit indicating that also the space for installing a heat recovery steam generator (HRSG) would be available. There is even sufficient space between the unit #1 through #4's old machine house and the V84.3A gas turbine to install a second gas turbine after demolishing some of the old boiler equipment. & Whitney and Siemens under a long-term technology exchange agreement signed in 1988. 01 Figure 3 shows how the compressor flow path design of the V84.3 gas turbine was changed into the V84.3A compres- The 100 MW size steam turbine of unit #4 could be rebuilt and used for repoweringln. Another option would be supplying a new steam turbine to optimally match the steam conditions of one or two new HRSG's. Such a steam turbine could be installed into the old machine house after removing unit # 1 and #2 steam turbine 121. V84.3A Gas Turbine The first V84.3A gas turbine is shown in Figure 2 leaving the gas turbine factory to be shipped to the Hawthorn Stationl,41). This unit was developed as the most advanced gas turbine featuring an aero-engine derived flow path designed by Pratt Figure 2. First V84.3A Gas Turbine Ready for Shipment 2

ea 10-41116 1 Flow Path -Vief:( ra BIM.... ism Oda 14+.1771 ""711111 4a) Controlled Diffusion Air-Foil Design V84.3 Compressor Section Present Profile Flow Path 1411 Tbmait.a. a"........,,,,,, II lignikomulkw.t304.7.. unir ----- dita-10111 I 111t4b ai -Ilan mannittmens, kr Advanced CDA Profile Controlled illusion Airfoil 4b) Side Wall Correction Chard Length Itisma ectrot E V84.3A Compressor Section Figure 3. Comparison of Compressor Flow Path Design Win Floor 40.adarf Urge sor design. The 15-stage compressor of the V84.3A unit has been designed for about the same flow capacity and pressure ratio as the 17-stage compressor of the V84.3 machine. However, a steeper increase of the curved inner diameter contour at about the first five stages was adopted providing a larger sum of circumferential rotating blade velocity, which consequently permits the reduction of compressor stages without having an adverse effect on performance. For the three-dimensional compressor blade profiles, illustrated in Figure 4, controlled diffusion air-toil design as applied earlier for the V84.3 first stages of rotating blades was now used for designing the entire compressor flow path (4a). This technique provides a higher level of stability during deceleration of the flow and a thinner boundary layer on the suction side of the compressor blade profiles. ttoordary Layer In addition, this figure shows the side wall correction for the stationary compressor grading at the hub and blade tip Figure 4. Compressor Flow Path Design 3

sections (4b). A more wedge-shape leading edge and a more rounded suction side reduces locally high velocity components. Through more uniform deceleration, the boundary layer even at the trailing edge does not experience any flow separation. By reducing the flow at the vicinity of the hub and blade tip, boundary losses are minimized. The turbine design has been adopted from the previous Siemens 4-stage design concept. However, more sophisticated blade cooling technique as well as metallurgical advances such as single crystal blading have been applied. With the exception of the last stage rotating blades, all turbine stationary and rotating blades are air cooled. Cooling air is provided at different pressure and temperature levels from compressor extractions to provide the best possible cooling effect and at the same time achieve optimal unit thermal performance. Flow straightening profiles in the turbine exhaust section are supplied to reduce exhaust losses. The high-performance blading of the 4-stage turbine section is illustrated in Figure 5. Free-standing blades are utilized in all stages to provide optimal flow conditions without any disturbance caused by dampening or shroud members. Also illustrated in this figure are the four stages' stationary blades. The turbine blading is designed for improved performance due to the minimization of any turbulent boundary zone and to provide a low entry velocity at the leading edge pressure side of the blade with continuous increase of the flow acceleration. All blades are designed for reliable long-term operation with the most efficient blade profiles. Figure 6 illustrates the sophisticated first-stage stationary blade cooling which receives cooling air for the leading edge of the blade from the compressor discharge at the blade row's inner diameter. The trailing blade section, which operates at a reduced main flow pressure level, receives cooling air from its outer diameter through the compressor discharge chamber formed by the outer casing surrounding the combustor Extensive film cooling is used to improve the cooling efficiency and to eliminate the need for an external first stage cooling air intercooling system. The applied high temperature blade design technology has been proven in aircraft engines operating at much higher firing temperatures. Figure 5. Four-Stage Turbine Blading Figure 6. First Stage Stationary Turbine Blade 4

Hybrid Burner Ring ( HBRTm) Combustor The HBR combustor with its 24 hybrid burners, illustrated in Figure 7, combines all the advantages of optimal combustion, including: High efficiency combustion Low NO. and CO emissions High operating flexiblity Minimum cooling air demand Fully symmetrical design utilizing a small variety of tiles Optimal size and number of burners Compact design with good accessibility Opti mal circumferential temperature distribution Multiple fuel capability Figure 8. Inspection of Burner in HBRTM Combustor Figure 7. Hybrid Burner Ring (HBRTM) Combustor The development of the HBRTM combustion system is a further step in reducing NO, emissions. At high firing temperatures, a decrease in cooing air requirements leads to an increase in combustion air for lower temperature permits combustion which internally reduces the NO. emission. Such an increase in combustion air is the result of optimizing the cooling air system. Heat shield pads are cooled by jet impingment which requires only a minimum amount of cooling air being taken from the compressor discharge flow. Based on extensive hybrid burner experience and test results from the full-load test facility, NO. emissions of less than 25 ppm when burning natural gas is expected'" ). The HBRTM combustor provides excellent accessibility. Two manholes are easily opened, and a full inspection of all hightemperature components as well as maintenance work can be performed. Figure 8 illustrates the inspection of one of the 24 burners. Gas Turbine Full-Load Tests In December 01 1994, this first V84.3A gas turbine reached an output of 170 MW on the test stand, shown in Figure 9 11, Full-load testing was performed over the last years in this facility to develop high-temperature gas turbines. The water friction break of the test stand can handle more than 180 MW at 3600 rpm. Figure 10 reveals the steps taken to fullload test the.3 and.3a-series gas turbine models over a period of approximately three years, starting with test of the V84.3 gas turbine with a flow path developed by Siemens'''. The next step was to introduce within the same envelope dimensions of the outer casing the flow path design jointly developed by Pratt & Whitney and Siemens which was installed and initially tested with horizontally arranged cylindrical combustion chambers.''' The last test series was performed with the latest development of the HBRTM combustor. This testing has been successful in supporting the extensive development work to build reliable advanced gas turbines. The efficiency of 38% was already confirmed during the initial test with HBRTM combustors in December of 1994. For reliable long-term operation, measurements of gas turbine blade temperatures and stress levels are of highest importance. Since full-load testing was performed, actual data under most severe operating conditions even with rated speed deviations were collected. Redundant measurements of blade temperatures were performed by thermocouples and infrared pyrometer sensor, providing a solid base of information about blade surface temperatures, temperature distribution and the proper function of the blade cooling. The data from the test facility, when compared to the originally calculated expected data, were in close agreement. Redundant measurement of dynamic blade stressing by strain gages and optical dual-probes also showed good agree- 5

Alt Inlet Housing OC Data Acquisition Con Id n Si I ubricallon Oil Supply Figure 9. Full-Load Test Facility avz-", '" ansztir V84.3 Gas Turbine with Cylindrical Combustion Chambers - ment with the calculated expected stress levels. Figure 11 shows that the dynamic stressing under full-load conditions in all four turbine blade rows are below 22% of the permissible dynamic stress level. To gain further long-time insight into the V84.3A gas turbine operating behavior, an agreement has been signed to perform a Durability Surveillance test program with EPRI, which will include an infrared pyrometer measurement of the first stage turbine blade temperatures. Air-Cooled Generator V84.3A Gas Turbine with Cylindrical Combustion Chambers V84.3A Test Gas Turbine with HBR Combustor Figure 10. V84.3A Gas Turbine Full-Load Test Sequence The air-cooled 200 MVA / 16 kv generator has been lifted from the railroad car onto the foundation at the Hawthorn power station by a hydraulic gantry lift as illustrated in Figure 12 1101. The complete generator was the heaviest piece to be handled at the site. The generator is designed for a power factor of 0.85 and 170 MW output at a cold gas (air inlet) temperature of 40 C (104 F); operating within Class B insulation limits [am to ANSI]; however, Class F insulation is provided. The capacity diagram in Figure 13 reveals the generator operating capacity under various operating conditions. The maximum capacity changes with the cold gas temperature. As shown, the capacity increases at 10 C (50 F) to 242 MVA. 6

0.6 Os 0.3 0.2 0,1 2 3 Turbine Wade Rows Figure 11. Measured Dynamic Loading of Rotating Turbine Blades With the selected direct cooling system, the air inlet temperature for the gas turbine and generator is the same. Both the gas turbine and generator following a decrease in inlet temperature by an increase in their maximum output. The generator capacity diagram also reveals the operating range for the generator operating in a synchronous condenser mode. When under excited and operating without active power at a power factor of zero, the apparent capacity of the generator is 87 MVAR. The internal generator design is shown in Figure 14, providing an optimal cooling scheme for both the stator and rotor 4 ISO 130 120 ILO 1 110 t 1 W 6 4 Mvar -1 20 2 2 Tr i w i so 100 140 160 42 010 0.70 1111 11tairAIIIMINIM Vall111121111aMil avactstasomann WE illawsity "t tdc MIECORMIPSWItittall IMMERSIMallitsn 40 kt"ti:slis.11111111 11 AIMIIREIRMENSC00011 ' EMMEN 1 11 LIMEIMMINIIIIR 020 CIAO 060 0.70 000 005 0.20 1.00 50 SO 103 120 140 160 ISO 199 239 NO 250 Power Factor Figure 13. Reactive Capacity Curve Cob! Gas.175 lamoimilf5 10.0 C 40.0C 60.0C 0.975 without any local hot spots. The arrangement of single-stage compressor fans on each side of the rotor ideally supplies cooling air into multiple flow paths of the stator and rotor. Air filters are installed upstream of the generator air intake 0.95 090 Figure 12. Lifting of Generator onto Foundation 7

Section Section A - A Generator B Terminals Pedestal Bearing :L a4.111 C Generator Endw(nding Support Generator Frame Uhl ill 10' ra"1 1 1" 11111, ii H! I mnir Spring Mounted Generator Core Air Fan Figure 14. Air-Cooled 200 MVA Generator to avoid contamination of the generator internals.the active generator core is assembled into the lower housing after it was VPI-treated. This vacuum/pressure impregnation (VPI) process is performed in the vacuum chamber and oven shown in Figure 15 providing a protective layer over the total winding assembly and the laminated iron core of the generator, making it extremely resistant against any environmental influence. MICALIASTIC insulation is used, which has proven unchanged high quality insulation performance for decades in generator windings for any rating and under most severe site conditions worldwide. Synchronous Clutch For the first time in the U. S., a large heavy-duty gas turbine will be equipped with a synchronous clutch for operation of the generator as a synchronous condenser. For this mode of operation, the generator has to be synchronized to the grid, motoring at rated speed. Such operation of the generator can only be performed with the turbine being disconnected from it. The clutch shown in Figure 16 is installed between the gas turbine and the generator to allow the following modes of operation to be performed: Figure 15. Generator Impregnation Facility Figure 16. Synchronous Clutch Installation 8

Gas turbine and generator run in unison during load operation Generator operates as a synchronous condenser at rated speed and turbine runs at turning gear speed Start-up of gas turbine driven by generator and frequency converter Shut down of gas turbine and generator in unison or gas turbine only For performing these functions, a synchronous clutch of the SSS Clutch Company has been selected, featuring an automatic engagement and locking system as shown in Figure 17, assembly drawing 17a.mi The automatic engagement system consists of a helical splined stub shaft and an axially moving bushing with two rows of teeth for the clutch engagement as well as the ratchet and pawl system matching the clutch engagement teeth (17b). This mechanical systern automatically engages the clutch whenever the turbine speed tries to exceed the generator speed. This function is performed by the helical sliding assembly moving from the disengaged to the engaged position. For unit start-up with the generator and its frequency converter driving the turbine, the clutch must be locked by the hydraulic locking system (clutch engaged and locked). This automatically controlled hydraulic locking is not needed for normal load or synchronous condenser operation. The various functions of the clutch are illustrated below (17c). Before the clutch can automatically disengage, it must first be 17a) Assembly Drawing Input Shaft Input Assembly Sliding Assembly Brake Unit Output Assembly Casing Output Shaft Clutch Disengaged (Unlocked) Locking Input Device Shaft Servo-Control Unit Mounted Oil on Clutch Housing Pressure Clutch Teeth Output Clutch Ring Sealing R ngs Keyplate Sealing Rings Locating Dowel Locking Teeth Clutch Engaged (Ready to Lock) Pawl and Ratchet Mechanism Helical Splines Oil Pressure Input Journa Bearing Oil Catcher Locking Sleeve Oil Catcher Output Journal Bearing As the Clutch Input Overtakes the Clutch Output. the Pawls Engage with the Ratchet Clutch Output Pawl,147,\N Ratchet Clutch Engaged (Locked) Oil Pressure Clutch Input and the Driving and Driven Teeth are Perfectly Aligned for Engagement. 17b) Clutch Teeth Alignment 17c) Modes of Operation Figure 17. Synchronous Clutch 9

GAS TURBINE HOUSE Gas Turbine Generator Air Intake Duct Diffuser Neutral Cubicle Bus Duct Synchronous Condenser Clutch Generator Circuit Breaker Motor Control Center Blade Cleaning Skid Dehumidifier Propane Tank CO, Fire Protection Tank VO Cabinet CO, Transfer Pump 74' Exhaust Stack 67' Luba Oil Cooler fl Continous Monitoring System Start-Up Transformer Transformer Excitation Transformer POW Control Center Luba OP Enclosure MECHANICAL CONTAINER fra Fuel Oil Skid Purge Water Skid atqbaffiroslainififiln Fuel Gee Skid NO. Reduction Skid Hydraulic Skid CO, Purge Tank Customer Interlace Point Figure 18. V84.3A Gas Turbine Arrangement unlocked. For changing from synchrounous condenser operation to positive power operation, the generator has to be brought down to turning gear speed. To accellerate this process a brake unit is provided. After locking the clutch at turning gear speed the gas turbine can be started up by the generator and its frequency converter. Both clutch stub shafts are supported by tilted pad journal bearings and the generator stub also features a thrust bearing. Relative axial movement between the turbine and generator stubs is therefore not possible in any clutch operation mode. V84.3A Simple-Cycle Plant Layout Conclusion After the successful testing of the first V84.3A gas turbine, it has arrived at the Hawthorn Station on January 11, 1997 to be assembled with the already supplied generator and synchronized clutch. Because of the already available full-load gas turbine test data including an efficiency in excess of 38%, it is expected that the simple cycle plant will perform as expected. Installation and start-up of the gas turbine plant will proceed to meet the requirement for generating summer peak capacity. Initial operation should start in springtime to optimize operation under various operating conditions including synchronized condenser operation of the generator. The V84.3A simple cycle plant arrangement drawing of Figure 18 shows the gas turbine-generator with all its auxiliaries from the stack to the transformer. The various auxiliary systems are pre-assembled and pre-tested in containers ready for interconnection and start-up. Fin-fan lube oil coolers are provided and together with the direct air-cooled generator arrangement, they eliminate the need for any cooling water supply. A 206-foot tall stack has been installed. Its transition duct connects to the gas turbine diffuser. 1 0

References PI Daledge, K., Rogers, T, Meyer, R. and Termuehlen, H., "Repowering of Steam Power Plants with Gas Turbines in the United States" Power-Gen Europe '94 Conference, KOln, Germany, May 17-18, 1994 I21 0eynhausen, H., Bergmann, B., Balling, L and Termuehlen, H., "Steam Turbine Development for Advanced Combined Cycle Power Plants" International Joint Power Generation Conference, Houston, Texas, October 14-16, 1996 DI Becker, B., Schulenberg, T and Termuehlen, H., "The 3A- Series Gas Turbines with HBR Combustors" America Society of Mechanical Engineers Turbo Expo, Houston, Texas, June 5-8, 1995 NI Becker, B. and Termuehlen, H., "Evolution of Siemens Gas Turbine Technology" Mexico Power 96, Monterrey, Mexico, October 8-10, 1996 (51 Maghon, H., Berenbrink, P, Termuehlen, H., Gartner, G., "Progress in NO. and CO Emission Reduction of Gas Turbines", ASME-Paper 90-JPGC/GT-4, 1990 NISchetter, B., Schabbehard, H. W. and Termuehlen, H, "Hy- brid Burner Combustion of Fuel Oil in a Premix Mode" Power- Gen Americas '94 Conference, Orlando, Florida, December 7-9, 1994 In Boehm, W., Raake, D., Regnery, D. and Seume, J., "Testing the Model V84.3A Gas Turbine - Experimental Techniques and Results" Power-Gen '96, Orlando, Florida, Dec. 4-6, 1996 Maghon, H., Becker, B., Schulenberg, T, Kraemer, H. and Termuehlen, H., "The Advanced V84.3 Gas Turbine" American Power Conference, Chicago, Illinois, April 13-15, 1993 191 Jansen, M., Zimmermann, H., Kopper, F. and Richardson, J., "Application of Aero-Engine Technology to Heavy-Entry Gas Turbines" Gas Turbine and Aero-Engine Congress, Houston, Texas, June 5-8, 1995 1101 Senske, K., Markus, H.v., "Air-Cooled Generators Air for 300 MVA' Modern Power Systems (MPS) May 1993 I'll Hendry, M. L. and McGough, J. C., "Synchronous Condensing Using the Generator of Peak Load Plant" International Gas Turbine Conference, Houston Texas 1995 11