FLORIDA DEPARTMENT OF TRANSPORTATION

Similar documents
ADDENDUM NO. 2 DATE: March 3, BID TITLE: Replacement of Two (2) Twenty Ton Overhead Crane Hoists, Trolley Packages, and Associated Equipment

Notice is hereby given of the following changes and questions and answers to the above referenced Bid:

VENDOR GRAND TOTAL INTENDED AWARD

FLORIDA DEPARTMENT OF TRANSPORTATION QUESTIONS AND ANSWERS

New Panelboard for Lot H, EV Charger Energization, Las Positas College. Scope of Work and Technical Specifications

BID SPECIFICATIONS 2018 TERMINAL BUILDING STANDBY GENERATOR PROJECT

COMMERCIAL QUICK REFERENCE

BID NUMBER: ITB-DOT-14/ SJ Page 1 of 5 STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION BID TABULATION

10 Commercial, Industrial, Agricultural Services

ADDENDUM NO. THREE (3) INSTALL BACKUP GENERATOR TERMINAL BUILDING SALISBURY-OCEAN CITY: WICOMICO REGIONAL AIRPORT SALISBURY, MARYLAND

Section 6 Electric Metering: Residential

4 FEET HIGH CHAIN LINK FENCE AND GATE. TO INCLUDE TOP RAIL AND ALL OTHER HARDWARE, POSTS, ETC. NOT INCLUDED BELOW.

Indianapolis Power & Light Company

Oncor Placard Guideline (rev 01/03/2012)

Customer Substation Manual

CITY OF TACOMA ENVIRONMENTAL SERVICES DEPARTMENT

ADDENDUM #2 TO BID # BID NUMBER: ISSUE DATE: Friday, January 18, 2019

D9-3. No. WIRING DIAGRAM CONNECTIONS FOR UNDERGROUND SELF CONTAINED METERS JRH JED krich95 LINE LINE ABCN SOURCE SOURCE GROUND GROUND STUD STUD SOURCE

WEST BRANDYWINE TOWNSHIP 198 Lafayette Road West Brandywine, PA Fax FEE: $75.00 (Up to 200 S.F.)

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Creative Bus Dba Getaway Bus REPRESENTING New England Wheels

City of Hammond Purchasing Department RFP # General Maintenance and Repair Service Contract City Generators

Electric Service Conversion Overhead-to-Underground Xcel Energy Electric Connections. Minnesota North Dakota South Dakota

UNDERGROUND SERVICE. Items to consider. There will be charges from ComEd if you convert from overhead to underground service.

Approved Meter Sockets and Cabinets

LIFT STATION 11 ONE-LINE DIAGRAM

RESIDENTIAL NEW CONSTRUCTION PACKET CITY OF VERO BEACH UTILITIES. Important Notice to Builders/Contractors/Developers From Electrical Engineering

Approved Contractor Construction e-guide Residential Commercial

CREATIVE BUS SALES, INC. REPRESENTING MOBILITY VENTURES, LLC

DESIGNER SUPPLEMENTAL INSTRUCTIONS DSI NO. MCA-DSI-0018

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

South Dock Replacement Prescott Park. This addendum forms part of the original document marked: Bid#44-14 South Dock Replacement Prescott Park.

COUNTY OF ROCKLAND Department of General Services Purchasing Division

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

10. METERING General Requirements

ECS CONNECTION OF LARGE LV SERVICES TO SECONDARY DISTRIBUTION SUBSTATIONS

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

See NT POWERCOS , Classification Based On Service Size.

enclosures and tanks kw gensets Specification sheet

Chapter 6 Generator-Voltage System

TABLE OF CONTENTS. Important Notices Underground Plant Protection Information. Commercial/Industrial Information Sheet

For Conduit Inspections

AGRICULTURAL UNDERGROUND SERVICE 500 HP OR LESS

City of Mobile. Recycling Equipment Rental & Hauling BID NUMBER: 5024

BID SPECIFICATIONS FOR (1) 300kW STANDBY GENERATOR

Appendix A Technical Specifications Class I, II, III, IV Sewage Pumping Lift Station Wet Well Cleaning and Hauling

UNDERGROUND SERVICES - SECONDARY

New Commercial Service Request-Job Process

Quik-Spec Coordination Panelboard Specifications

ADDENDUM #1. A. Alternate Bid Item #3A - The procurement and installation of a new 12,000 gallon UL 2085 rated AGT tank for

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

ELECTRIC SERVICE RULES UTILITY/CATV SERVICES Issued Jan 2016

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

GENERAL INFORMATION 1.01 PURPOSE

Expedited Permitting Process for Electric Vehicle Charging Stations

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

CHAPTER V RESIDENTIAL WIRING

ADDENDUM NO. 1. April 6, Project: Gas and Diesel Bid for School System Stations

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

PURCHASING DEPARTMENT

ADDENDUM NO. 1 INVITATION FOR BIDS FOR LUBRICANT AND FLUID SUPPLY. RFP NO.: 2018-SP-03 Date Issued: March 13, 2018

Metering and Service Installation:

FOR SALE Acres Improved Agricultural Land Former Aquaculture Facility in Martin County, Florida SW Martin Highway, Indiantown, FL 34956

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Identify nozzle placement options

ATTACHMENT I BID SCHEDULE IFB NO , CHURCH FARMS EAST STORAGE TANK AND BOOSTER PUMP STATION

FLORIDA SHERIFFS ASSOCIATION, FLORIDA FIRE CHIEFS ASSOCIATION, & FLORIDA ASSOCIATION OF COUNTIES

Pentahead bolts See note 2. Conduit run as specified. Company facility. Refer to drawing SS8.6-2 or SS8.6-3 STANDARD SERVICE INSTALLATION

Requirements for Secondary Voltage Revenue Metering (750 V and less)

The Green Meter Adapter (GMA) program will become effective on January 15, Customers may start applying for a GMA on January 15, 2018.

Electrical Safety Program

INVITATION TO BID PURCHASING DEPARTMENT P. O. BOX E. CENTRAL AVENUE THIRD FLOOR VALDOSTA, GEORGIA 31601

DOCUMENTATION PACKAGE

Customer Requirements Downtown Secondary Network Service

STOUGHTON UTILITIES ELECTRIC SERVICE RULES AND INFORMATION

Electric & Gas Service Requirements (Greenbook) Overview

City of Manhattan Beach Community Development

Grounding Systems. Equipment Grounding & Grounded Conductors

CONTENTS. Foreword...iii. 1. Introduction...1

Construction and Connection of Street Light Assets

DOCUMENTATION PACKAGE

City of Portsmouth Portsmouth, New Hampshire Department of Public Works. Bid# Five (5) 2018 Ford Trucks INVITATION TO BID

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES

Service & Installation Rules

Generator Fire Safety: Generator assemblies should be located outside the building.

Solar Power Installation Application

To complete the process for a net metering interconnection, please follow the steps below:

CONTRA COSTA COMMUNITY COLLEGE DISTRICT

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2

ELECTRIC DIVISION RULES AND PROCEDURES FOR ELECTRIC SERVICE

Outdoor Enclosure Power System ENC X100MP48F20-AC6

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

GENERAL NOTES ELECTRICAL NOTES MATCH LINE SEE SHEET E1.11 KEY PLAN NTS MATCH LINE SEE SHEET E1.12 SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" SPR-2" TYP DH-108

Transcription:

FLORIDA DEPARTMENT OF TRANSPORTATION ADDENDUM NO. 1 DATE: 3/8/2011 RE: BID/RFP #: RFP-DOT-10/11-9031-LG BID/RFP TITLE: FURNISH AND INSTALL EMERGENCY GENERATOR POWER SYSTEM AT CARYVILLE OPENING DATE: March 22, 2011 at 3:00 PM, Local Time Notice is hereby given of the following changes to the above-referenced BID/RFP: 1. Questions and Responses 2. CHANGE: Replace Appendix A with attached Appendix A Bidders/Proposers must acknowledge receipt of this Addendum by completing and returning to the Procurement Office, by no later than the time and date of the bid/proposal opening. Failure to do so may subject the bidder/proposer to disqualification. Bidder/Proposer Address Submitted by (Signature) Lillian Graham. Procurement Agent Failure to file a protest within the time prescribed in Section 120.57(3), Florida Statutes, or failure to post the bond or other security required by law within the time allowed for filing a bond shall constitute a waiver of proceedings under Chapter 120, Florida Statutes.

RFP-DOT-10/11-9031-LG FURNISH AND INSTALL EMERGENCY GENERATOR POWER SYSTEM AT CARYVILLE QUESTIONS AND RESPONSES QUESTION 1 What size LP underground fuel tank is required for Caryville? 1. The site sketch, page A4 of 6 shows a 1000 gallon tank 2. Section 2.2.9, page 61 Fuel System and Storage states a 1000 gallon tank 3. Section 2.2.9.1, page 61 Fuel Tank states a 2000 gallon tank requirement. 4. Figure 2.2 Underground LPG Tank Installation Drawing, page 62 shows a 2000 gallon tank 5. Table A.1, page 111 lists a 1000 gallon tank RESPONSE 1 See Scope of Services section 1.1 last paragraph. The Contractor shall perform the work based on the requirements of the site as delineated in Appendix A. In this case a 1000 gallon fuel tank is required.

FLORIDA DEPARTMENT OF TRANSPORTATION APPENDIX A CARYVILLE I-10 SITE REQUIREMENTS Page A1 of A6

FLORIDA DEPARTMENT OF TRANSPORTATION A. 1 CARYVILLE SITE REQUIREMENTS THE CONTRACTOR SHALL NOT DEVIATE FROM THE SITE SPECIFICS WITHOUT WRITTEN AUTHORIZATION OF THE PROJECT MANAGER OR A DESIGNATED REPRESENTATIVE. The following items shall be furnished and installed at the Caryville site: A. One 35 KW (minimum) LP gas fueled emergency generator, 1000-gallon (minimum) below ground fuel tank, automatic transfer switch, and fuel level sensor, and associated SPD devices specified in this section. For commonality among other FDOT microwave site emergency generators in the District, the generator and transfer switch shall be Cummins 35GGPA and Cummins OTEC 125, respectively and the fuel level sensor shall be Squibb Taylor, Inc. Stationary Tank Monitor. The generator, fuel tank, and automatic transfer switch shall be installed as shown in Figures A.1. The tank and generator shall be located and installed in accordance with local building codes. The base of the generator shall be installed a minimum of two feet above grade. The Contractor shall wire all alarms to a Contractor s supplied punch block. The wiring shall be performed as listed in Figure 8.1 in Section 8. The Contractor shall power the generator s coolant heater from a Contractor provided circuit breaker. The circuit breaker shall be sized per the manufacturer s recommendation. B. Fencing for fuel tank enclosure in accordance with Section 2.6. New fencing and a gate shall be installed per Figure A.1. Clearing of existing shrubs and grubbing is required in the fenced area. A combination lock shall be installed on the new gate, Masterlock Model # 177. The Contractor shall coordinate with the FDOT Project Manager for establishing the combination of the lock. C. Install an AC power SPD in accordance with Section 2.4.1. The new SPD shall be Atlantic Scientific Zone Master 11200 as shown in Figures A2. The SPD shall be installed on the load side of the outdoor main breaker, located on the exterior North Wall of the Caryville communications shelter. The secondary main breaker on the exterior wall shall be removed and conduit shall be routed outdoor to interior Panel West. D. The Caryville site has an existing MOV/SAD hybrid SPD with surge counter connected to the existing ATS. This unit is to be connected to the load side of the new 125 Ampere Cummins ATS. Page A2 of A6

FLORIDA DEPARTMENT OF TRANSPORTATION THE FOLLOWING TABLE LISTS THE MAJOR ITEMS TO BE FURNISHED AND/OR INSTALLED BY THE CONTRACTOR. THIS TABLE DOES NOT INCLUDE ALL PARTS AND PIECES REQUIRED BY THE CONTRACT AND SHALL BE USED FOR INFORMATIONAL PURPOSES ONLY.ITEM QUANTITIES ITEM QUANTITIES 35 KW emergency generator (Cummins 35GGPA) and foundation 1 Generator Main Breaker Rating (100 Amp, 2-Pole) 1 Automatic transfer switch (Cummins OTEC 125) 1 Below ground 1000 gallon LPG tank w/(4)- 9 lb Annodes 1 Fuel level monitoring device with SPD device 1 Generator alarm SPD devices (4 pins each) 5 Annunciator LonWorks 1 Main disconnect AC Power SPD device with spare modules 1 Distribution Panel AC Power SPD device NA Page A3 of A6

Generator Fuel Tank Shelter Existing Perimeter Layout Page A4 of A6 FLORIDA DEPARTMENT OF TRANSPORTATION New Pad 35 kw Spark Ignited Gas Generator Remove existing fuel tank Coolant Heater Fuel Level Sensor Battery Control Alarm Power Fuel Line Fuel Vent Conduit COMMERCIAL POWER METER Shelter 4 ft. Proposed Perimeter Layout A1. Caryville (3-3429) Scale: 1/16" = 1'-0" COMMERCIAL POWER LINE NOTES: 1.) Remove South side gate and 20' of the existing East fencing enclosure. 2.) Remove existing generator 3.) 8' X 20' fence enclosure at 4'-0" from the shelter East wall. 4.) Install gate & padlock for gas company access 5.) Install a 1000 Gallon LPG Buried Tank With 4-9 lb. Anodes for cathodic protection 6.) Install (6) 5/8" X 10'L solid copper ground rods per diagram Bond to ground ring and fence corner post. 7.) Grounding Conductor # 2 Tinned Solid Bare Copper 8.) Ground all conduit entries on North wall. 9.) Call to locate UG power line before digging.

Page A5 of A6 Existing Exterior North Wall FLORIDA DEPARTMENT OF TRANSPORTATION NOTE: EXTERIOR WALL PENETRATIONS HAVE BEEN CORE DRILLED PER SECTION 4.7 OF THE SCOPE DOCUMENT. 1. COOLANT HEATER 2. FUEL LEVEL SENSOR 3. BATTERY CONTROL 4. ALARM 5. AC POWER 4 3 Panel East 5 2 1 REPLACE 200A 2P WITH 100A 2P Proposed Exterior North Wall A2. Caryville (3-3429) Scale: 1/2" = 1'-0" Panel West FROM GENERATOR COMMERCIAL POWER OUTPUT ATS POWER 16" FROM OUTPUT ATS POWER ASC ZONE MASTER 11200 OUTDOOR ENCL.

Page A6 of A6 ATS VoIP Existing Interior North Wall FLORIDA DEPARTMENT OF TRANSPORTATION Panel West A3. Caryville (3-3429) Panel East 125AMP ATS A 21 FL VoIP New Punch Block 1. Control Conduit 2. Fuel Level Sensor Proposed Interior North Wall Scale: 1/2" = 1'-0" 16" TO MTS COMM GENSET