Series 230 Automatic Transfer Switch

Similar documents
ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

SIRCO MV PV Load break switches for photovoltaic applications for use up to 1000 VDC from 63 to 80 A

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Motorised and automatic transfer enclosed switchess

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

ATyS t M - ATyS g M Automatic Transfer Switching Equipment from 40 to 160 A

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

PROTECTION AND CONNECTION. ABB Compact ATS Compact without compromise

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Load break switches. Load break switches for all your applications... Why choose a load break switch designed for photovoltaic applications?...

COMPLETE SOLUTIONS FOR POWER PROTECTION

MCD 200 Series Soft Starters


Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

Miniature Circuit Breaker

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Experience, innovation and reliability

XBoard Series 630A Distribution Box. XBoard Series. Distribution Box for Commercial and Industry

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

An innovative technology

PowerLine OS Switch Fuses A, 690V

Selection Guide Motor Control Device Solutions

25A 25A 32A 40A 40A 63A 63A 80A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

SIRCO M and MV Universal load break switches from 16 to 160 A

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Innovac SVS/08 - SVS/ kv modular switchgear

DRX 250 B/N/H Circuit breaker (not adjustable)

Softstarter Intelligent Controllers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Longest Life Product for Electric Furnace Applications! 100,000 Operations No Routine Maintenance Required!

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Protection components

DRX 100 B/N/H Circuit breaker (not adjustable)

SD Series Non-Fused Load Switches

Technical Data Accessories MCBs Ex9B.

DRX 125 Circuit breaker (not adjustable)

SIRCOVER. Manual Transfer Switching Equipment from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for.

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Surge-Trap Pluggable STPT2 Series - 40kA

FUSERBLOC Fuse combination switches with rear connection for industrial fuses up to 400 A


3 - Protection components Motor circuit-breakers

BETA Switching Switches and Light Indicators

Modular contactor for installation into distribution boards

MoDPlus Din Distribution Boards

SIRCOVER. Manual transfer switches from 125 to 3200 A. Transfer switches. Function. Advantages. The solution for. Strong points

Panel Mount Switches

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

SFS-UFS Single Foot Switches

LOAD BREAK SWITCHES. Ensto Compact

Single & Three-Phase Soft Starters

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

atalog Welcome to ATO.com! Contact us... Tel: (Toll-free) Website:

Enclosed changeover switches Automatic operation ATSE * - Automatic equipment from 40 to 3200 A Integrated products

LINOCUR Size D02 63A 230VAC/440VAC

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Logstrup Modular System

A compact range of Switch-Disconnectors with the capacity to add auxiliary and neutral block options to the basic load break switch block.

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

18-I73E CAT REF.

Transfer switch OHPC open or delayed transition

Safety Control HR1S-AC. Safety Relay HR1S-AC

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

FUSERBLOC Fuse combination switches for industrial fuses up to 1250 A

VersaRupter 5-38 kv Load Interrupter Switch. Technical Guide

Horizontal Circuit Switchers

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

THE SANTON FCS-TYPE SWITCH DISCONNECT. Superior Switch Solutions

Horizontal Circuit Switchers

JCAM SWITCHES. Model Ratings / Product Numbering System...J2 Technical Data...J3

Low Voltage Assemblies

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Metal Clad Air Insulated Switchgear

SPECIFICATION SHEET ORION ROAD LANTERN. IP66 RATED CRI. 230v /50hz

Solid Dielectric, Single Phase Recloser

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

15-I73E CAT REF.

D509E. Manual Motor - Starters

Transcription:

Series 230 Automatic Transfer Switch

Product overview The Series 230 automatic transfer switch consists of an intelligent controller and a modular load break switch which automatically transfers the load to the emergency power source when it detects the normal power source under/over voltage, under/ over frequency, or phase loss. The switch has three operational positions (Source I, Center-off, Source II). The two sources are isolated when the switch is in the center-off position. A center-off position locking mechanism is also provided. The recognised leader in power transfer switch technology offers the most advanced transfer switches in the world. Application The Series 230 transfer switch is available in single and three phase configurations up to 80A, and for higher power applications in three phase configurations up to 800A at 415 Vac and 50Hz. Typical applications include commercial and residential buildings, hospitals, telecom, subway and transportation, data centers, military and fire pumps. Switch specification Frame: A2ADTL B2ADTL C2ADTL D2ADTL E2ADTL Rated Operational Current Ie (A): 63-80 100-160 200-250 315-400 500-800 Rated Insulation Voltage U i (V) 800 1000 1000 1000 1000 Rated Impulse Withstand Voltage U imp (kv) 8 8 12 12 12 Rated Operational Voltage U e (V) 240 and 400 (415) Rated Frequency (Hz) 50 Poles 2,4 4 Rated Short-Time Withstand Current I cw (ka, RMS) 6 (0.03s) 10 (0.1s) 5 (0.1s) 25 (0.1s) 40(0.1s)/ 20(1s) Rated Short-Circuit Making Capacity I cm (ka, PEAK) 8 17 31.5 65 80 Withstand and Making Conditional Short-Circuit Rating I q (ka) Making and Breaking Capacity When Used With Current Limiting Fuses When Used With Specific Circuit Breakers 65 65 200 200 200 15 50 150 150 80 10 I e Mechanical Operation Performance (cycles) 10,000 Utilization Category Operational Voltage 125~300V Ue= 240V / 400V range (AC) (L-N) EMC Class Wiring Way Separate Lock Mechanism AC-32A, AC-33B (0.7~1.2) Ue Class A Front Standard Auxiliary Contact (Optional) 4 contacts 8 contacts maximum maximum ASCO Power Technologies Phone: 1300 556 601

Switch performance features Power Contact (PC) Class ATS High ability to withstand lightning strikes (40kA 8/20μs) Simple reliable mechanism, Compact Modular design, convenient operation, easy maintenance Three position operation Both sources can be isolated in a center-off position Switching mechanism Unique contacts design limits contact bounce Unique clutch design makes manual operation easy and low force Electrically and mechanically interlocked prevent two sources from connecting simultaneously Permanent Magnet DC motor as power mechanism has large starting torque and wide range of operation voltage Innovative motor circuit protection ensures precision operation Cast steel bevel gear mechanism provides high transmission efficiency, and extends operating life Controller Different operating modes (automatic, remote control and manual) C300 and C2000 can work with an external 24VDC power supply High frequency switching power supply, and wide power voltage range Data (e.g. Event log, setting, etc) remains intact if power is lost Intelligent fault diagnostics enable self-protecting motor feature RS485 communication interface is available Priority source swap Arc extinguishing The utilization categories are AC-32A, AC-33B Rotating dual contact design extinguishes the arc quickly and effectively Separate arcing contacts and main contacts Wiping-action contacts are self cleaning High short-circuit making and short-time withstand ratings Phone: 1300 556 601 ASCO Power Technologies 1

Controller specification C300 C2000 Rated Operation Voltage Ue(V) 220/230/240 (1) 380/400/415 Rated Frequency (Hz) 50/60Hz 50/60Hz Display Indicator Source(I,II) Available ATS Position Control Mode Manual/Automatic Source I Priority No Source Priority Remote Control Unique Control Function Remote control Priority (2) Priority Source Swap Diagnosis fault intelligent with self -protection function Source Sensing Setting Voltage Sensing (3) L1-N,L2-N,L3-N L1-L2,L2-L3,L3-L1 Frequency Sensing Power loss Phase loss (4) L1,L2,L3 L1,L2,L3 Undervoltage 65%, 70%, 80%, 85% 70% ~ 98% Overvoltage 120% / OFF 102% ~ 120% / OFF Overfrequency Transfer 115% 102% ~ 115% Underfrequency Transfer 85% 85% ~ 98% Time Delay Setting Override Momentary Source Outage 1s 0 ~ 3s Transfer to Source II 0s, 5s, 30s, 5min 0 ~ 5min Transfer to Source I 1s, 30s, 5min, 30min 0 ~ 30min Engine Cooldown 2min 0 ~ 60min Center-Off Position Delay OFF / 5s 0 ~ 5s Others RS-485 Optional Additional 24V DC Power Input Generator Control Signal Output Fire Control Signal Input Alarm Auxiliary Contact Optional Optional Event Log Display Type LED LED+LCD Installation DIN rail installation and Panel installation Panel installation Yes, Standard; Blank: Not Available/ Not Applicable Remarks: 1. For 3 phase application the C300 is powered by L-N voltage 2. Only available for source priority mode 3. For C300 controller, Source II Voltage sensing is only on L1 4. For C300 controller, Source II Phase loss sensing is only on L1 2 ASCO Power Technologies Phone: 1300 556 601

A2ADTL frame Current Number Voltage Controller Controller RS485 Part Number Rating (A) of Poles Rating (V) Type Mounting Comms. 63 2 240 C300 DIN - Embedded NO ATS63A2PC3NC 63 2 240 C300 DIN - Embedded YES ATS63A2PC3 63 4 400 C300 DIN - Embedded NO ATS63A4PC3NC 63 4 400 C300 DIN - Embedded YES ATS63A4PC3 80 2 240 C300 DIN - Embedded NO ATS80A2PC3NC 80 2 240 C300 DIN - Embedded YES ATS80A2PC3 80 4 400 C300 DIN - Embedded NO ATS80A4PC3NC 80 4 400 C300 DIN - Embedded YES ATS80A4PC3 Unit: mm A 20.5mm 108mm B 93mm 96mm 107mm 121.3mm 124mm 110mm 45mm 120mm Ă4.5mm 171mm 18mm C A2ADTL 2P 4P Size (mm) A 216.0 252.0 Weight (kg) 1.6 2.0 Note: DIN rail mountable B2ADTL frame Current Number Voltage Controller Controller RS485 Part Number Rating (A) of Poles Rating (V) Type Mounting Comms. 100 4 400 C2000 Panel Mount YES ATS100A4PC2 125 4 400 C2000 Panel Mount YES ATS125A4PC2 160 4 400 C2000 Panel Mount YES ATS160A4PC2 Unit: mm 112mm 117mm 104mm 78mm 29mm 184mm 126mm 214mm 15mm 27mm A B2ADTL 4P Size (mm) A 349.0 Weight (kg) 3.1 Note: DIN rail mountable Common load side bars included as standard. Terminal shields included. Phone: 1300 556 601 ASCO Power Technologies 3

C2ADTL frame Current Number Voltage Controller Controller RS485 Part Number Rating (A) of Poles Rating (V) Type Mounting Comms. 200 4 400 C2000 Panel Mount YES ATS200A4PC2 250 4 400 C2000 Panel Mount YES ATS250A4PC2 Unit: mm 168mm 194mm 182mm 50mm 128mm 23.5mm 172mm C2ADTL 4P Ø6mm 12.5mm 20mm 9mm A 319.0 Size (mm) B 304.0 C 136.0 150.5mm 130mm 1 1 6m m 100mm 126mm Weight (kg) 5.8 6mm Common load side bars included. Phase separators included. 9mm 7.5mm 177mm B A 34mm C D2ADTL frame Current Number Voltage Controller Controller RS485 Part Number Rating (A) of Poles Rating (V) Type Mounting Comms. 315 4 400 C2000 Panel Mount YES ATS315A4PC2 400 4 400 C2000 Panel Mount YES ATS400A4PC2 173mm 228mm 215mm 52mm 144mm 2.5mm 199mm Unit: mm D2ADTL 4P A 405.0 15.5mm 25mm 10mm Size (mm) B 385.0 C 191.0 Weight (kg) 11.0 186mm 158mm 140mm 120mm 120mm Common load side bars included. Phase separators included. 10mm(0.4") Ø7mm 206mm B A 44mm C 4 ASCO Power Technologies Phone: 1300 556 601

E2ADTL frame Current Number Voltage Controller Controller RS485 Part Number Rating (A) of Poles Rating (V) Type Mounting Comms. 500 4 400 C2000 Panel Mount YES ATS500A4PC2 630 4 400 C2000 Panel Mount YES ATS630A4PC2 800 4 400 C2000 Panel Mount YES ATS800A4PC2 180mm Unit: mm 252 mm 240mm 165mm 57mm 2 2 6mm 10mm 8mm E2ADTL 4P A 514.0 Size (mm) B 487.0 C 276.0 Weight (kg) 20.0 Common load side bars included. Phase separators included. 290mm 265mm 208mm 160mm 14mm Ø9mm 228mm 65mm B A C 13mm 45mm 19mm 174mm 195mm C2000 Controller 191±1 Run Auto Alarm 132 80 86 142 Source I Source II UP 134±1 Transfer Switch Position Esc Down Enter 189 197 Panel Opening Dimensions Weight: 1kg Unit: mm Phone: 1300 556 601 ASCO Power Technologies 5

C300 Controller connections NC suffix indicates no RS485 port 24V 24V RS485 24V DC Power Input Generator Start Alarm Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II Push to test RS485 GEN ALM FIRE DI 1 DI 2 DI 3 DI 4 485 Port User Terminations C2000 Controller connections 24V Alarm O I II TS Position Generator Start RS485 Fire Control Input Transfer to Position O Transfer to Position I Transfer to Position II ALM DO1 DO2 DO3 GEN 485 PORT FIRE DI5 DI6 DI7 X4 User Terminations C2000 CONTROLLER X1 Power Terminal X2 Control Terminal X3 User Terminal Power and Voltage Detection Transfer Switch Position Detection and Transfer Control 24V DC Power Input Lost Power Loom to Transfer Switch X1 Loom to Transfer Switch X2 24V 6 ASCO Power Technologies Phone: 1300 556 601

Accessories Auxiliary contacts Part Number Output Current LAP1F100 NO 5A LAP1F010 NC 5A Auxiliary contact output configurations Position of the Transfer Switch Auxiliary Contact Output Position of the Transfer Switch Auxiliary Contact Output Part Number LAP1F100 LAP1F010 X 2 Part Number LAP1F100 LAP1F010 X 2 Auxiliary Contact Mounting Position (only showing C2ADTL, D2ADTL, E2ADTL). Auxiliary Contact Mounting Position (only showing C2ADTL, D2ADTL, E2ADTL). I I O O II II Enclosed automatic transfer switches Enystar Insulated Enclosure ATS IP65 Polycarbonate enclosure Modular enclosure system to add distribution Hinged clear door Single and three phase 63 and 80A Current Number Controller RS485 Rating (A) of Poles Type Comms. IP Rating Material Colour Dimensions Part Number 63 2 C300 NO IP65 Polycarbonate Grey-RAL 7035 270Wx360Hx236D ATS63A2PC3FP 80 2 C300 NO IP65 Polycarbonate Grey-RAL 7035 270Wx360Hx236D ATS80A2PC3FP 63 4 C300 YES IP65 Polycarbonate Grey-RAL 7035 360Wx5400Hx236D ATS63A4PC3FP 80 4 C300 YES IP65 Polycarbonate Grey-RAL 7035 360Wx5400Hx236D ATS80A4PC3FP Phone: 1300 556 601 ASCO Power Technologies 7

Mild steel enclosure ATS 1.5mm thickness mild steel 2mm thick galvanised mounting plate Drainage hole in the bottom (NOTE IP rating will be compromised) Concealed and removable hinges with pins Polyurethane sealing gaskets IP66 Top and bottom glandplates Hinged door with clear window Load side bars included Phase separators (terminal shields for B Frame) included Current Number Controller RS485 Rating (A) of Poles Type Comms. IP Rating Material Colour Dimensions Part Number 63 2 C300 NO IP66 Mild Steel Grey-RAL 7035 400Wx600Hx200D ATS63A2PC3EG 80 2 C300 NO IP66 Mild Steel Grey-RAL 7035 400Wx600Hx200D ATS80A2PC3EG 63 4 C300 YES IP66 Mild Steel Grey-RAL 7035 400Wx600Hx200D ATS63A4PC3EG 80 4 C300 YES IP66 Mild Steel Grey-RAL 7035 400Wx600Hx200D ATS80A4PC3EG 100 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx600Hx200D ATS100A4PC2EG 125 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx600Hx200D ATS125A4PC2EG 160 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx600Hx200D ATS160A4PC2EG 200 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx800Hx300D ATS200A4PC2EG 250 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx800Hx300D ATS250A4PC2EG 315 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx1000Hx300D ATS315A4PC2EG 400 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 600Wx1000Hx300D ATS400A4PC2EG 500 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 800Wx1200Hx400D ATS500A4PC2EG 630 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 800Wx1200Hx400D ATS630A4PC2EG 800 4 C2000 YES IP66 Mild Steel Grey-RAL 7035 800Wx1200Hx400D ATS800A4PC2EG Current Number Controller RS485 Rating (A) of Poles Type Comms. IP Rating Material Colour Dimensions Part Number 63 2 C300 NO IP66 Mild Steel Orange-RAL 2008 400Wx600Hx200D ATS63A2PC3EA 80 2 C300 NO IP66 Mild Steel Orange-RAL 2008 400Wx600Hx200D ATS80A2PC3EA 63 4 C300 YES IP66 Mild Steel Orange-RAL 2008 400Wx600Hx200D ATS63A4PC3EA 80 4 C300 YES IP66 Mild Steel Orange-RAL 2008 400Wx600Hx200D ATS80A4PC3EA 100 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx600Hx200D ATS100A4PC2EA 125 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx600Hx200D ATS125A4PC2EA 160 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx600Hx200D ATS160A4PC2EA 200 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx800Hx300D ATS200A4PC2EA 250 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx800Hx300D ATS250A4PC2EA 315 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx1000Hx300D ATS315A4PC2EA 400 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 600Wx1000Hx300D ATS400A4PC2EA 500 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 800Wx1200Hx400D ATS500A4PC2EA 630 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 800Wx1200Hx400D ATS630A4PC2EA 800 4 C2000 YES IP66 Mild Steel Orange-RAL 2008 800Wx1200Hx400D ATS800A4PC2EA 8 ASCO Power Technologies Phone: 1300 556 601

Enclosed ATS to suit evolution distribution boards 1.5mm thickness mild steel 2mm thick galvanised mounting plate Modular enclosures Polyurethane sealing gaskets Top and bottom glandplates Load side bars included Phase separators (terminal shields for B Frame) included Current Number Controller RS485 Rating (A) of Poles Type Comms. IP Rating Material Colour Dimensions Part Number 63 2 C300 YES IP40 Mild Steel Grey-RAL 7035 600Wx400Hx200D E43ATS63A2PC3L 80 2 C300 YES IP40 Mild Steel Grey-RAL 7035 600Wx400Hx200D E43ATS80A2PC3L 63 4 C300 YES IP40 Mild Steel Grey-RAL 7035 600Wx400Hx200D E43ATS63A4PC3L 80 4 C300 YES IP40 Mild Steel Grey-RAL 7035 600Wx400Hx200D E43ATS80A4PC3L 100 4 C2000 YES IP40 Mild Steel Grey-RAL 7035 600Wx600Hx200D E43ATS100A4PC2L 160 4 C2000 YES IP40 Mild Steel Grey-RAL 7035 600Wx600Hx200D E43ATS160A4PC2L 200 4 C2000 YES IP40 Mild Steel Grey-RAL 7035 600Wx600Hx200D E43ATS200A4PC2L 250 4 C2000 YES IP40 Mild Steel Grey-RAL 7035 600Wx600Hx200D E43ATS250A4PC2L 400 4 C2000 YES IP40 Mild Steel Grey-RAL 7035 600Wx600Hx300D E43ATS400A4PC2L Current Number Controller RS485 Rating (A) of Poles Type Comms. IP Rating Material Colour Dimensions Part Number 63 2 C300 YES IP40 Mild Steel Orange-RAL 2000 600Wx400Hx200D E43ATS63A2PC3A 80 2 C300 YES IP40 Mild Steel Orange-RAL 2000 600Wx400Hx200D E43ATS80A2PC3A 63 4 C300 YES IP40 Mild Steel Orange-RAL 2000 600Wx400Hx200D E43ATS63A4PC3A 80 4 C300 YES IP40 Mild Steel Orange-RAL 2000 600Wx400Hx200D E43ATS80A4PC3A 100 4 C2000 YES IP40 Mild Steel Orange-RAL 2000 600Wx600Hx200D E43ATS100A4PC2A 160 4 C2000 YES IP40 Mild Steel Orange-RAL 2000 600Wx600Hx200D E43ATS160A4PC2A 200 4 C2000 YES IP40 Mild Steel Orange-RAL 2000 600Wx600Hx200D E43ATS200A4PC2A 250 4 C2000 YES IP40 Mild Steel Orange-RAL 2000 600Wx600Hx200D E43ATS250A4PC2A 400 4 C2000 YES IP40 Mild Steel Orange-RAL 2000 600Wx600Hx300D E43ATS400A4PC2A Phone: 1300 556 601 ASCO Power Technologies 9

Enclosed ATS to custom requirements Using IP66 IDE enclosure system or Evolution DB enclosure systems Customised colours Assembled to customer requirements With backup fuses Sub distribution Surge protection Polyurethane sealing gaskets Tested to: IEC60947-6-1: Transfer Switch Standard IEC60947-3: Switch/ Isolation standard EN55022: Radiated and Conducted Emission, Class A EN61000-3-2: Harmonic Current Emission, Class A EN61000-3-3: Limits of Voltage fluctuation and Flicker EN 61000-4-5: Immunity to Surge EN 61000-4-4: Immunity to Electrical Fast Transient EN61000-4-2: Immunity to Electrostatic Discharge EN61000-4-3: Immunity to Radiated Electric Fields EN 61000-4-6: Immunity to Continuous Conducted Interference 10 ASCO Power Technologies Phone: 1300 556 601

High Performance ATS 200 Series Options for 2P, 3P, 4P solid Neutral, 4P switched neutral or 4P Overlapping Neutral Open transition only Open frame or enclosed versions 7000 Series Options for 2P, 3P, 4P solid Neutral, 4P switched neutral or 4P Overlapping Neutral Open transition, closed transition, Softload ATS All arrangement available with bypass, available as enclosed option only Open or enclosed versions available. For use in applications where power supply is critical, downtime is unaffordable and reliability is crucial. Phone: 1300 556 601 ASCO Power Technologies 11 Phone: 1300 556 601 ASCO Power Technologies 11

DARWIN CAIRNS BRISBANE PERTH NEWCASTLE SYDNEY ADELAIDE MELBOURNE HOBART National Customer Support Centre Tel: 1300 556 601 Fax: 1300 550 187 Email: customerservice@ipdgroup.com.au IPD Group Ltd. Copyright 2017