Automatic Panel AT205 for gasoline and diesel generators THE PROJECT

Similar documents
Te 804 Electronic Controller. Service, Operation & Technical Information Manual

ENGINE PROTECTION BOARD PDM1

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

TE2010-GE Instructions manual

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Technical Data Sheets

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

INSTRUCTION AND USE MANUAL

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

AUE-AUD-AU2E AU2D-AUED

The measurements module provides the following engine features information:


Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

Technical Data Sheets

AF40... AF96 3-pole contactors Technical data

DKG-317 MANUAL AND REMOTE START UNIT

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Switches Unlimited Phone: * Fax:

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

Electronic overload relays EF205 and EF370

Electronic overload relay EF65, EF96 and EF146

DATA SHEET Genset Control Unit, GCU 100

TECHNICAL SPECIFICATIONS

CONTROL, PROTECTION AND VISUALIZATION ELECTRONIC MANUAL CEN- TRALITE FOR GENERATING SETS CMD2.0

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

1 / Genset general description

1 Phase electronic contactor (SC 1)

3 - Protection components Motor circuit-breakers

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

1 / Genset general description

Thermal Overload Relays

AME. Rectifier - Battery charger. Industrial applications: Key features:

1 / Genset general description

Essential equipment for all your requirements

Industrial contactors CTX-1

DKG-207 AUTOMATIC MAINS FAILURE AND REMOTE START UNIT

Ktec Contactors and thermal overloads

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

UMBW-UL489 and UL1077 Listed

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

DKG-707 MULTI GENSET PARALLELLING UNIT WITH J1939 INTERFACE

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Induction Power Supplies

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

Industrial Contactors CTX 3 3P 185A - 800A

DKG-109 AUTOMATIC MAINS FAILURE UNIT

enerbox Pannello di controllo per 2 pompe (optional) Control panel for 2 pumps (optional) Pannello di controllo standard Standard control panel

Page 2-4 Page 2-8. Page Page 2-13

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 41,8/33,4 46,0/36,8 64,02 400/ ,8 41,8/33,4 46,0/36,8 66,42

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

DKG-215 MANUAL AND REMOTE START UNIT

POWER kva

SDM72 Start on Demand Modules

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Technical specification

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

VOLTAGE HZ PHASE COS Ø PRP KVA/KW LTP KVA/KW AMPERAGE 415/ ,8 450,0/360,0 495,0/396,0 689,46 400/ ,8 450,0/360,0 495,0/396,0 715,32

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

HGM6320T AUTOMATIC GENERATOR CONTROLLER USER MANUAL

TECHNICAL DATA SHEET KVA UPS Systemss

Model: HHY 20 C T INDUSTRIAL RANGE Soundproof Powered by YANMAR

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

DIESEL Engine Fire Pump Controllers Features

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Modular contactors and relays

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

Power Controller. (see note 1) 10 sec

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheets

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Technical Data Sheets

Komatsu Power Generation Systems

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

Transcription:

Automatic Panel AT205 for gasoline and diesel generators Ith contactors with temperature </= 40 C KVA/400V-3Ph KVA-230V-3Ph KVA-230V-1Ph 25 17 10 9 45 31 18 16 56 38 22 20 60 42 24 22 THE PROJECT In the project of the automatic panel AT205, Tecnoelettra has committed to realize an highly industrialized product. Design has been minded in every detail. New materials for the frontal injection pressing have been used. Sturdiness has been kept by the metal bottom and a new remarkable electronic card has been created. This new electronic card has remarkable potentialities which are linked to an exceptional easiness in utilization. To reduce delivery times the board is completely equipped with all the important accessories: emergency button, sound alarm Buzzer, 16A light switch with 230V exit for external load control such as emergency lamp, preheating, etc STANDARD COMPOSITION 1-metal case 15/10 thick painted by epoxy powder RAL7042 1-cover realized by injection pressing, in plastic material type PPVO, fire fighting and resistant to atmospheric agents. 2-mains-genset switching contactors both electrically and mechanically blocked 1-automatic device for battery charge 900mA maintenance 1-Buzzer 1-bright and 2 poles and 16A-230V switch 7-Protection fuses (3 monophase) 2-terminal boards for auxiliaries connection to engine 3-fairleads for connecting cables entry: mains, genset, user 1-control device with display (see functions description at page 5)

Buzzer for sound alarm. It sounds both in case of alarm and to inform that the generator is going to be started by a remote signal. AUTOMATIC PANEL AT205 VIEW On/Off switch from 16A-230V for exit control at 230V to be used for possible emergency lamp, pre-heating, etc 900Ma automatic battery charger Protection fuses for mains and generator auxiliaries input and battery positive Mains-generator switching by mechanical and electrical interlocking. Switching is standard 4 poles in order it can be also used in single phase by bonding the two poles. In this case, capacity of the contactor must be calculated multiplying the thermic current Ith x1,6 Terminal board for load connection Emergency button Arrangement for installation of circuit breaker for genset protection. Amperometric transformers allows not only the current is shown on the display but it is also used to achieve overload protection by electronic board 3 fairleads for power cables entry for mains, generator and user 2 connectors (provided with plugs) for connection of external engine signals and external controls such as start, remote stop, EJP, SCR.

CONTRUCTIVE FEATURES Panel finishing with cover fixed to the bottom Simple and intuitive control keyboard Opening system with supporting bar in order to ease internal access Finishing qualitiy Wide space for power cable connection and arrangements of components Back view for fairleads which are positioned for power cables entry, terminal board for cables connection to the engine and terminal board for signals connection. Both are supplied with plugs This connector allows customer to remote a general alarm signal or to control the board by remote signals for start and stop by a level sensor. Or, it is possible to block the panel by a switch or EJP or SCR

KEYBOARD DESCRIPTION PHASE- to select phase L1-L2-L3 which display measures refer to Led for indication of measured phase -L1- L2-L3 Indicating led for selected measures: Hz Rpm Ampere KVA Battery voltage Hour counter Hours to maintenance MEAS to select the measure to be shown on the display. The selected measure is indicated by its led lighting Test keys to select manual or automatic (calendar arrangement) Led V Mains and V Gen to indicate if measure on the display refers to mains or generator Led for running engine Keys for functioning selection: MAN-manual start and stop by START and STOP keys AUT-automatic RESET- to cancel an alarm message and block all the functions of the board Led for mains and generator voltage on A01- Alta temperatura motore A16-Bassa frequenza Gen. A02- Bassa pressione olio A17-Alta frequenza Gen. A03- Guasto sensore pressione A18- A04- Basso livello carburante A19-Alta tensione generatore A05 Tensione batteria alta A20-Asimmetria generatore A06- Tensione batteria bassa A21-Corto circuito generatore A07- Batteria inefficiente A22-Sovraccarico generatore A08- Alternatore carica batteria A23-Intervento protezione esterna Gen. A09- Avaria segnale motore in moto A24-Errata sequenza fasi generatore A10- Bassa velocità motore A25-Errata sequenza fasi rete A11- Alta velocità motore A26-Errata impostazione frequenza A12- Mancato avviamento A26-Anomalia contattore Gen. A13- Arresto di emergenza A28-Anomalia contattore Rete A14- Avaria meccanica A29-Richiesta manutenzione A15- Mancato arresto A30-Errore sistema A31-Ore noleggio esaurite A32-Basso livello liquido radiatore A33-Interruttore protezione Gen.chiuso A34-Interruttore protezione Gen. Aperto A35-Allarme da carica Batteria START and STOP keys to stop the generator during manual functioning Key mains contactor closing during manual functioning Led for showing mains or generator contactor is closed Key for manual genset contactor closing during manual functioning Led for alarms on Table which shows alarms codes. Adhesive labels are supplied in different languages: English French German

Functions description for control device with three-phase survey for genset and mains voltage On the frontal part we find the following commands and indications: Disply at 4 digit to have a look at some codes and alarm names, measures and parameters for setup CODES AND ALARMS NAMES VISUALIZATION A01-high engine temperature A02-low oil pressure (digital sensor) A03-pressure digital sensor failure A04-low fuel level (digital sensor) A05-high battery voltage A06-low battery voltage A07-inefficient battery A08-battery charger alternator failure A09- failure on signal for rev-counter survey A10-low engine speed A11-high engine speed A12-starting failure A13-emergency stop A14-unexpected stop (it means that the card having given the stop command does not survey the starting engine and therefore the stop is surely due to a mechanical problem) A15-stop failure A16-low generator frequency A17-high generator frequency A18-low generator voltage A19-high generator voltage A20-generator asymmetry A21-short circuit A22-generator overload Protection A21 and A22 take part according to some parameters set up in an proper Menu in which the following parameters are set up:rated current for generator; limit of maximum current in %; limit of current for immediate intervention in %; delay of the maximum current in seconds ;time for protection restoration in seconds A23-external generator protection intervention A24-incorrect generator phases sequence A25-incorrect mains phases sequence A26-wrong frequency system setup A27-generator contactor failure A28-mains contactor failure A29-request for maintenance A30-system error (it is a self-checking of the operating system of the card) A31-rent hours exhausted A32-low radiator liquid level A33- magnetothermic switch for closed genset protection A34-magnetothermic switch for open genset protection this function is important both in the manual and automatic functioning since it guarantee that switch is in the right position in both functioning systems A35-alarm from battery charger UA1-adjustable users alarm UA2- adjustable users alarm UA3- adjustable users alarm UA4- adjustable users alarm ELECTRICAL MEASURES VISUALIZATION Generator and mains voltage phases on L1-L2- L3 Generator and mains frequency Genarator rev-counter Ampere for every phase of Generator and Mains on L1-L2-L3 kva battery volt Hourcounter hours to the maintenance Visualization of all the set up parameters through access with password to the following menu: Menu 01- Usefullness contains the parameters that refer to the calendar, the month and the year Menu 02- General contains all the parameters that refer to the electrical parameters (TA; type of line L-L/L-n/L- L+L-N; frequency;ect Menu 03- Battery to be used to set up all the parameters for battery control Menu 04- motor starter allows to set up all the parameters that refer to engine starting both for diesel engines and petrol engines provided with compressed air systems Menu 05-engine control are parameters that refer to all engine functioning limitssuch as minimum and maximum limit of speed, etc Menu 06- mains control to be used in order to set up all parameters for mains control like minimal and maximum voltage limit, maximum voltage, asymmetry, frequency etc Menu 07- generator control to be used to set up all the parameters of alternator control like minimal and maximum voltage, asimmetry, frequency, etc Menu 08- generator protection, to be used to set up all parameters for loading limits control for generator functioning, like rated current, minimum and maximum level, etc Menu 09- test and maintenance to be used to set up all parameters for test and maintenance of generator, like test qualification, test break, days where test is excluded, beginning time, test period with and without load, break for maintenance time, etc Menu 10- door and communication are parameters that refer to RS232 and RS485 utilization Menu 11- several in this menu all standard and custom fuctions are provided (realized on specific customer s request) like generator threshold for starting and stopping according to mains kw; dummy load command with on/off treshold;rent hours; choosing functioning way (EjP;SCR etc);automatic block and test; Starter of the generator in case mains switch failure. SPECIAL FUNCTIONS ( page 7) generator Start/Stop on mains kw threshold Dummy load Command Renting hours Block for automatic and test ways Engine Starting for TLGR failure Functioning mode exit Remote start SCR EJP

Battery rated voltage Maximum current absorbed Maximum power consumption/dissipation Functioning range Stand-by current Input type Current input Low input signal High input signal Input signal delay Input type Voltage range Frequency range Technical Characteristics for Electronic circuit 12 or 24VDC without distinction 250mA at 12VDC and 125mA at 24VDC 3W 9 35VDC ma to 12VDC and ma to 24VDC Digital input negative 8mA 1,5V (typical 2,9V) 5,3V (typical 4,3V) 50ms Speed input "w" (terminal 2.3) Coupling AC 5 50Vpp 40 2000Hz Input (500rpm) battery charger alternator with permanent magnets (terminal 2.1) Functioning range 0 40VAC Input (500rpm) for pre-excited battery charger alternator ( terminal 2.2) Functioning range Maximum input current Maximum voltage at +D terminal Pre-excitation current Contact type Utilization category Voltage use Rated capacity at 250VAC Contact type Category rating Voltage use Rated capacity at 250VAC Contact type Category rating Voltage use Rated capacity at 250VAC Contact type Category rating Voltage use Rated capacity at 30VDC Maximum current on common terminal of relays Type of interface Baud-rate Maximum Ue rated voltage Measurement range Frequency range Measuring type Measuring input impedance Wiring connections Rated current le Measurement range Type of measure Permanent thermic limit Short thermic limit Self-consumption 0 40VDC 12mA 12 o 24VDC (battery voltage) 170mA at 12VDC or 130mA at 24VDC Relay output for generator contactor terminals 5.1-5.2 (voltage free) 1 NO B300 30VDC 1A Auxiliary service 250VAC rated (440VAC max) 8A in AC1 (2A in AC15) Relay output for mains contactor terminals 5.3-5.4-5.5 (voltage free) 1 in switching B300 30VDC 1A Auxiliary service 250VAC rated 8A in AC1 (2A in AC15) Relay output terminals 4.1-4.2-4.3 (voltage free) 1 in switching B300 30VDC 1A Auxiliary service 250VAC rated 8A in AC1 (2A in AC15) Relay output terminal 4.5-4.7-4.8-4.9 (Voltage on + battery) 1 NO for relay and terminal in common 30VDC 1A Auxiliary service 30VDC 5A in DC1 12ADC Interface of communication with PC RS232 Adjustable 1200...38400bps Volt metric input for mains and generator 100 480VAC L-L (277VAC L-N) 50 620V L-L (358VAC L-N) 45 65Hz True and effective value (TRMS) >1,1MΩ between L-L e >570kΩ between L-N 1 phase, 2 phases, 3 phase with or without neuter Amperometric inputs 5A feeded by external current transformer (low voltage) 0,05 6A True and effective value (RMS) +20% Ie 50A for 1 second <0,3VA

Measuring accuracy Measuring conditions Temperature Relative humidity Voltage Current +23 C ±1 C 45 ±15% 0,1 1.2 Ue 0,2 1.2 Ie ±0,25% f.s. ±1digit ±0,55% f.s. ±1digit ±1digit Voltage Current Frequency Apparent power ±0,5% f.s. ±1digit Additional errors Relative humidity ±1digit 60% 90% R.H. Temperature ±1digit 20 +60 C Environmental functioning conditions Working temperature -20 +60 C Storage temperature -30 +80 C Relative humidity <90% Maximum pollution degree degree 3 Connections Terminal type extractable Cable cross section (min and max) 0,2 2,5 mmq (24 12 AWG) Tightening torque 0,5 Nm (4,5 LBin) Standard references IEC/EN 60255-6, IEC 60664-1, IEC/EN 61000-4-5, IEC/EN 61000-4-4, IEC/EN 61000-4-3, IEC/EN 61000-4-6, IEC/EN 60255-22-2, IEC/EN 55011, IEC/EN 60255-21-2, IEC/EN 60068-2-6 (LROS-Lloyd s Register Of Shipping), IEC/EN 60068-2-52 (RINA), IEC/EN 60028-2-61, IEC/EN 61010-1 and UL 508/C22.2_N14-95 (culus). SERIES SPECIAL FUNCTIONS There are some special functions that can be activated by entering a password in a special program menu called SET-Up. The functions are: Start/Stop genset on mains threshold kw It allows setting up the minimal and maximum threshold of the kw when it wants to start or stop the generator with load switching from mains to genset Dummy load command It allows inserting a fictitious load in order to avoid the generator on with low load. Its possible to set up the minimal and maximum threshold in kw of intervention with relative times and cycles. Rent hours It allows to set up an overdue time for rent which stops the generators. Block for Automatic and Test It can be used when it is necessary to use generator only in Manual mode.this function allows Automatic and Test functions turn off. Engine Starter fortlgr failure In case the generator finds breakdown on mains contactor, the genset is automatically started and load is transferred under the genset contactor Exit from functioning mode It is possible to activate an exit for indication for board functioning status Remote start This function is on only on automatic functioning. it allows start and stop the generator by external contact opening and closing even if mains is on. Switching occurs only when lack of mains is surveyed. SCR This function is on only during automatic functioning and it allows: To start the generator through the closing of an external contact To carry out the load switching on the generator when mains is on To stop the generator when contactor opens and to switch the load to the mains EJP It is a specific function for French market and it can be activated in two different ways: EJP (standard) by closing an outside contact, then, after an adjustable time of 30', the generator will start. The closing of a second contact controls the load switching to the generator EJP/T- starter of the generator happens by closing an outside contact; the switching comes after an adjustable time of max 30' Note In both case it is possible to select whether the load shall remain on the generator or if it has to be switched on the mains in case of generator failure,

AT205 electrical scheme

Protection degree Homologation references General features Dimensions IP-20 REFERENCES FOR ORDERS Three-phase version-3ph Single phase version -1Ph KVA-400V KVA-230V code KVA-230V code 0-17 0-10 AT205400T17 0-9 AT205230M09 18-31 11-18 AT205400T31 10-16 AT205230M16 32-38 19-22 AT205400T38 17-20 AT205230M20 39-42 23-24 AT205400T42 21-22 AT205230M22 The capacity of the contactors refers to the Ith with temperature </= 40 C Packing for 1 panel Packing Total dimensions of box: h-220xl-350xp-470 Pallets can be supplied. Every standard pallet may contain 35 panels. Total dimensions of the pallet become 1560(Height) X 800(Large) WEIGHT for SINGLE PACKING WEIGHT for PALLET containing 35 panels (including the pallet) Kit for series supplied accessories 6.5Kg 251Kg N 2-engine terminal board N 1-handbook N 2-Fischer for wall fixing N -2 fuses

PANEL TYPE Optionals MAGNETIC CIRCUIT BREAKER 2P SWITCH 3P SWITCH 3P+N SWITCH AMPERE 10 +157ATIM2P010 +157ATIM3P010 +157ATIM4P010 16 +157ATIM2P016 +157ATIM3P016 +157ATIM4P016 20 +157ATIM2P020 +157ATIM3P020 +157ATIM4P020 25 +157ATIM2P025 +157ATIM3P025 +157ATIM4P025 32 +157ATIM2P032 +157ATIM3P032 +157ATIM4P032 40 +157ATIM2P040 +157ATIM3P040 +157ATIM4P040 50 +157ATIM2P050 +157ATIM3P050 +157ATIM4P050 63 +157ATIM2P063 +157ATIM3P063 +157ATIM4P063 SHEATS AND POWER CABLES FOR CONNECTION TO ALTERNATOR 16A-Single phase-2p+t 1570516 32A- Single phase -2P+T 1570515 16A-Three-phase-3P+N+T 32A-Three-phase -3P+N+T 1570516B 1570515B KIT for HONDA ENGINES GX390 and GX600 Kits allow Honda engines type GX390 and GX600 to be provided with all accessories which can assure the generator start automatically without any problem. Kits have been projected and tested in order to assure a fast and sure installation by preventing the necessity to buy other accessories, nor screws. A specific software which is included in AT panels controls closing and opening air (especially the re-opening at the right moment in order to avoid the engine loose its speed). Power sheath to be connected to the plug installed in the generator and engine sheath are included in kit proposal. Engine sheath is suitable to be added without any intervention on Honda engine.. AUXILIARY SHEAT FOR CONNECTION TO THE ENGINE HONDA GX-390 HONDA GX-600 KIT STARTER AIR CONTROL 1570514C 1570514D HONDA GX-390 1570511 HONDA GX-600 1570512 KIT THERMOSTAT HONDA GX-390 E GX-600 1570513