Motor Circuit Breakers C4

Similar documents
Motor Circuit Breakers C3

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

3VU13, 3VU16 Circuit-Breakers

Phone: Fax: Web: -

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Protection Equipment. 5/2 Introduction

D509E. Manual Motor - Starters

Components for EEx e Panels

Miniature Circuit Breakers

Manual Motor Starters. Meta-MEC

DPX Magnetic only

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Control Circuit Protection

Protection Equipment

Bulletin 190-M Compact Starters. Selection Guide

3 - Protection components Motor circuit-breakers

Manual Motor Starters

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

DPX earth leakage DPX 3 -I earth leakage

Type MS450 MS497. Phone: Fax: Web: - Manual motor protectors

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Series KTU7 UL489 Molded Case Circuit Breakers

Motor Protection Circuit Breakers 3VU13 and 3VU16

MPCB. We touch your electricity everyday! State of the art Manufacturing Facilities. Haridwar, Noida Ph-I & Noida Ph-II Plant

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

Series KTU7 UL489 Molded Case Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

System pro M compact Miniature Circuit Br eakers Description Features

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

ACS motor protection circuit breakers KT 7 Introduction

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

MS General Information Extended Product Type: MS

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

US CATALOG. Miniature circuit breakers

UBW Family UL489 Molded Case Circuit Breakers

Protective Devices: Circuit-Breakers 1 )

F Motor Circuit Controllers. Series KT7 Motor Circuit Controllers. KT4 Manual Motor Starters. General Description...F2

Series L9 UL489 Miniature Circuit Breakers

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Motor Controllers + Circuit Breakers

Low voltage circuit breakers

max pole for t=15 ms

Circuit breakers for power distribution A1 Ordering information

MC FRAME SIZE 1 / UP TO 160A

UL 489/CSA C22.2 No. 5 Listed C60 Circuit Breakers 1.22 [31.1] 1.77 [45.1] 4.86 [123.4] Clearance 1.77 [45]

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

MC FRAME SIZE 1 / UP TO 160 A

AF40... AF96 3-pole contactors Technical data

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Short form catalogue Motor protection and control Manual motor starters

Bulletin 140M Motor Protectors

Protection components

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

3VF3 to 3VF8 Circuit-Breakers

Technical Information

www. ElectricalPartManuals. com Miniature Circuit Breakers Section 7

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

PowerPact B. Molded case circuit breakers and switches from A

DPX Electronic + earth leakage

SENTRON Switching and Protection Devices Switch Disconnectors

Motor Starter Protectors

FMotor Circuit Controllers & Circuit Breakers

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Selection Guide Motor Control Device Solutions

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

US CATALOG. Miniature Circuit Breakers

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

3VT Kompaktleistungsschalter bis 630A

3RT14 Contactors with 3 Main Contacts

MOULDED CASE CIRCUIT BREAKERS BC160N

4 - Miniature controls

Series L9 UL-489 Miniature Circuit Breakers

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

C E R T I F I C A T E O F C O M P L I A N C E

Technical data for manual motor starters Type MS325

TeSys GV2 - GV3 Manual Starters and Protectors

BETA Switching Switches and Light Indicators

Pro M Miniature Circuit Breakers S260, S270, S280, S290. System Pro M. Description

Thermal-Magnetic Circuit Breaker 201/-WA

Circuit breakers. Panorama. PB111746_30.eps PB111749_30.eps

SENTRON Switching and Protection Devices Molded Case Circuit Breakers

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Transcription:

Motor protection rating up to 100 Amps Short circuit breaking capacity up to 100kA Phase failure protection DIN rail mounting Wide range of accessories Options and ordering codes Model C4/32T Setting Short Part ref Ultimate short circuit breaking/ Setting Short Part ref Ultimate short circuit breaking/ range circuit service capacity < 400V AC range circuit service capacity < 400V AC release max fuse A release max fuse A C4/32R A A Icu - ka Ics - ka gl/gg A A Icu - ka Ics - ka gl/gg 0.10-0.16 2.1 C4/32T-0.16 100 100 -- 0.10-0.16 2.1 C4/32R-0.16 100 100 -- 0.16-0.25 3.3 C4/32T-0.25 100 100 -- 0.16-0.25 3.3 C4/32R-0.25 100 100 -- 0.25-0.4 5.2 C4/32T-0.4 100 100 -- 0.25-0.4 5.2 C4/32R-0.4 100 100 -- 0.4-0.63 8.2 C4/32T-0.63 100 100 -- 0.4-0.63 8.2 C4/32R-0.63 100 100 -- 0.63-1 13 C4/32T-1 100 100 -- 0.63-1 13 C4/32R-1 100 100 -- 1.0-1.6 20.8 C4/32T-1.6 100 100 -- 1-1.6 20.8 C4/32R-1.6 100 100 -- 1.6-2.5 32.5 C4/32T-2.5 100 100 -- 1.6-2.5 32.5 C4/32R-2.5 100 100 -- 2.5-4 52 C4/32T-4 100 100 -- 2.5-4 52 C4/32R-4 100 100 -- 4-6 78 C4/32T-6 100 100 -- 4-6 78 C4/32R-6 100 100-5 - 8 104 C4/32T-8 100 100 -- 5-8 104 C4/32R-8 100 100 -- 6-10 130 C4/32T-10 50 38 80 1) 6-10 130 C4/32R-10 100 100 -- 9-13 169 C4/32T-13 50 38 80 1) 9-13 169 C4/32R-13 100 100 -- 11-17 221 C4/32T-17 20 15 100 1) 11-17 221 C4/32R-17 50 38 100 1) 14-22 286 C4/32T-22 15 11 100 1) 14-22 286 C4/32R-22 50 38 125 1) 18-26 338 C4/32T-26 15 11 100 1) 18-26 338 C4/32R-26 50 38 125 1) 22-32 416 C4/32T-32 15 11 100 1) 22-32 416 C4/32R-32 50 38 125 1) Model C4/63R C4/100R Setting Short Part ref Ultimate short circuit breaking/ Setting Short Part ref Ultimate short circuit breaking/ range circuit service capacity < 400V AC range circuit service capacity < 400V AC release max fuse A release max fuse A A A Icu - ka Ics - ka gl/gg A A Icu - ka Ics - ka gl/gg 18-26 338 C4/63R-26 50 50 125 1) 45-63 819 C4/100R-63 50 38 160 1) 22-32 416 C4/63R-32 50 50 125 1) 55-75 975 C4/100R-75 50 38 160 1) 28-40 520 C4/63R-40 50 50 160 1) 70-90 1170 C4/100R-90 50 38 160 1) 34-50 650 C4/63R-50 50 50 160 1) 80-100 1300 C4/100R-100 50 38 160 1) 45-63 819 C4/63R-63 50 50 160 1) -- No back-up fuse required 1) Back up fuse required if short circuit current at installation point >Icu - ka

Accessories Top mounted auxiliary contact block, max 1per circuit breaker 1NO + 1NC C4/32 C4HQ11-32 1NO + 1NC C4/63/100 C4HQ11-63-100 2NO All C4HQ20 2NC All C4HQ02 Auxiliary contact block for left hand side mounting, 2per circuit breaker (except C4/63R) (cannot be fitted next to another breaker on a bus bar) 1NO + 1NC All C4HS11 2NO All C4HS20 2NC All C4HS02 Trip alarm/magnetic trip alarm switch for left hand side mounting, max 1 per circuit breaker Trip alarm 1NO + 1NC short circuit signal alarm All C4MA11 Magnetic trip alarm 1NO + 1NC short circuit signal alarm C4/32R C4M11 Auxiliary releases for right hand side mounting, max 1 per circuit breaker Under voltage trip: trips the circuit breaker 24V 50Hz, 28V 60Hz All C4U24 when the voltage is interrupted. 110 to 127V 50Hz, 120V 60Hz All C4U110 Prevents accidental restart. 220 to 230V 50Hz, 240 to 260Hz 60Hz All C4U230 240V 50Hz, 277V 60Hz All C4U240 380 to 400V 50Hz, 440 to 460Hz 60Hz All C4U400 415 to 440V 50Hz, 460 to 480Hz 60Hz All C4U415 Shunt trip: trips the circuit breaker when 24V 50Hz, 28V 60Hz All C4A24 the release coil is energised. 110 to 127V 50Hz, 120V 60Hz All C4A110 220 to 230V 50Hz, 240 to 260V 60Hz All C4A230 240V 50Hz, 277V 60Hz All C4A240 380 to 400V 50Hz, 440 to 460V 60Hz All C4A400 415 to 440V 50Hz, 460 to 480Hz 60Hz All C4A415 Accessories Description For use with Type Scale cover: for cover current setting scale All C4K Push in lugs: for plate mounting C4-32 C432L Insulation barrier: up to 600V acc. UL489 for increased rating acc. UL Type E C4-100 C4100E Link modules For mechanical fixing and electrical connecting between circuit Description Version Type Link module for electrical and mechanical for C4/32... with contactors MB C432VK1 max 32A connection for C4/32... with contactors MC10 to MC22 C432VK3 max 32A for C4/32... with contactors MCD10 to MCD22 C432VKG3 max 32A Link module for electrical connection for C4/32... with contactors MC(D)24 to MC(D)40 C432VD max 32A for C4/63... with contactors MC24 to MC74 C4663VD max 63A for C4/63... with contactors MCD24 to MCD40 C463VDG max 63A for C4/100... with contactors MC50 to MC74 C4100VD max 100A

Accessories continued Insulated 3-phase busbar system For feeding several modular circuit breakers on standard mounting rails, insulated and shock protected. Rated operational voltage 690V. 3-phase busbars modular spacing 45mm for 2 circuit-breakers C432S2 for 3 circuit-breakers for 4 circuit-breakers for 5 circuit-breakers C4/32 C432S3 C432S4 C432S5 3-phase busbars modular spacing 55mm for 2 circuit-breakers C4/63 C463S2 Line side terminal Conductor cross section solid or stranded 6-25mm 2 C4/32 C432SE 3-pole, connection from above with end sleeve 4-16mm 2 Cover for tags Touch guard for empty spaces C4/32 C432SF Mounting parts for motor circuit breaker/contactor combination breaker and reversing or YD states 35mm DIN rail (DIN 50022) or screw mounting C4/32 C432HUI C4/63 C463HUI C4/100 C4100HUI C4/32 C432HU2 Busbar adapters Busbar adapter for mechanical fixing of 60mm system for 3 copper busbars acc. to Din 46433, width 12 and 15mm thickness: 5, 10mm C4/32 C432SA60 Door coupling rotary mechanisms The door locking device prevents accidental opening of the cubicle door in the ON position of the circuit-breaker. The OFF position can be locked with up to 3 padlocks. Door-coupling rotary extention shaft 115mm M4-32R C4/32R-EH1-115 mechanism black extension shaft 315mm M4-32R C4/32R-EH1-315 extension shaft 115mm M4-63R C4/63R-EH1-115 extension shaft 315mm M4-63R C4/63R-EH1-315 extension shaft 115mm M4-100R C4/100R-EH1-115 extension shaft 315mm M4-100R C4/100R-EH1-315 Emergency-Stop extension shaft 115mm M4-32R C4/32R-EHN1-115 Door-coupling extension shaft 315mm M4-32R C4/32R-EHN1-315 mechanism; red/yellow extension shaft 115mm M4-63R C4/63R-EHN1-115 extension shaft 315mm M4-63R C4/63R-EHN1-315 extension shaft 115mm M4-100R C4/100R-EHN1-115 extension shaft 315mm M4-100R C4/100R-EHN1-315

Dimensions (mm) Circuit-breaker C4-32T 3) Shunt or undervoltage release of arcing 5) Push-in Lugs for screw mounting Circuit-breaker C4-32R 3) Shunt or undervoltage release of arcing 6) Push-in Lugs for screw mounting 7) 35mm DIN-rail acc. to EN 50022

Dimensions (mm) Circuit-breaker C4-63R 3) Shunt or undervoltage release Circuit-breaker C4-100R 3) Shunt or undervoltage release 7) 70mm DIN-rail acc. to EN 50023 8) 4mm hexagon socket screw