RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Similar documents
RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

RVS-AX Instruction Manual

R820 REV2 SERIES SCR POWER CONTROLS NOVEMBER 2017

GTS 15/25/40/50/60/75/90/120A

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

amp ramp Operators Manual Page 1 Saftronics 2S Ltd Turnbridge Mills Quay Street Huddersfield West Yorkshire HD1 6QT

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

INDUSTRIAL POWER SUPPLIES SFL-SERIES

1.1 Caution Statements

A6Z OPERATING MANUAL

SOLSTART Instruction Manual

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

1 Phase electronic contactor (SC 1)

Solid State Relays contactor with Integrated Fuse Type RGC1F

This manual is to be given to the end user. Eur en / e. Remote speed reference input. Remote current speed reference input (A1)

A1P OPERATING MANUAL

J TS 7090 Thyristor power switch

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

Heat Meter Integrator

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

A3Z OPERATING MANUAL

DEVICE STATE/BYPASSED FAILURE OVERLOAD

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

SCR Power Controllers

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Power Switching Principles

Power systems Protection course

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Phase + Neutral, neutral on left side

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

GTS-L4 5 / 10 / 15 TECHNICAL DATA

Design Guide. VLT Soft Start Controller MCD 100

SDS Enclosed Star-Delta Starter User Guide

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

DX³ RCCBs - ID 4P up to 100 A

LS200 Series Instruction Manual

Phase + Neutral, neutral on right side

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

up to 63 A (1 module per pole)

GTZ 25 / 40 / 55. THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac PROFILE. TECHNICAL DATA General features

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Starting Torque Limiter Type TCI (Soft Start)

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Features. Description. Table of Contents

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Model Number Structure

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

This manual is to be given to the end user. Optional RFI filter. Drive. Stop. Thermal protection device. Start / Reset +DC.

Question Number: 1. (a)

Electronic Circuit Breaker ESS20

Phoenix Inverter

Installation Manual for DC Injection Brake Units

EST Electrical Service Technician Answer Schedule

24V 3A EN54 Ancillary Power Supply

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

TX³ RCCBs 2P up to 100 A

INFRESCO-S-4kW X20034 Issue: 7

TRU100 MODEL 937 TEMPERATURE REFERENCE UNIT HANDBOOK

Smart Battery Charger

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Solid State Relays, 3-phase

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Temperature Controllers

Pan and Tilt Head CDD2416-T

Temperature Controllers

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Professional Wireless Products

Dimensions WxHxD [mm] Weight [kg]

HIB Enclosed Inverter User Guide

Burst-Firing 74B5 LISTED INDUSTRIAL CONTROL EQUIPMENT. User Manual

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

Transcription:

Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No additional heat sinks or RFI filters required Technical Overview The RE-PR1-F series are a range of thyristor stacks which provide full seamless control of single-phase electric heating loads, to provide adjustable control in proportion to the demand control signal. These burst fire control assemblies use fast pulse, zero volt, switching technology to minimise flicker and eliminate RFI problems. They also incorporate a temperature trip, automatic reset, integral ceramic/semiconductor fuses and heatsink. Applications include electric heater batteries and duct heaters.

Page 2 of 5 Specification: Input signal 0-10Vdc or 0-5Vdc Supply (load) 230Vac RMS ±10% 50/60Hz Power / current ratings 1.5kW 6.3A 3kW 12.5A 25A Fusing (integral): 1.5kW F10A Ceramic quick blow type ferrule fuse 3kW F16A Ceramic quick blow type ferrule fuse FF30A High speed semiconductor type ferrule fuse Terminal connections (rising cage): 1.5 & 3kW For 2.5mm² cable max. For 2.5mm² (signal), 4mm² (power & earth) cable max. Torque settings 0.5Nm (power terminals only) Over temperature: Trip in temp. @ 90 C (194 F) ±1 C (1.8 F) Trip out temp. @ 85 C (185 F) ±1 C (1.8 F) Fault condition 24V (ass power supply) LED indication T1 & T3 LED s pulse when output is ON Ambient temperature 65 C (149 F) maximum Dimensions (W, D, H): 1.5 & 3kW 112 x 95 x 75mm (4.41 x 3.74 x 2.95 ) 112 x 95 x 85mm (4.41 x 3.74 x 3.35 ) Conformity CE Marked Country of origin UK Part Codes: RE-PR1-F-1.5 1.5kW, 6.3A, Din-rail Mount Heating Regulator RE-PR1-F-3 3kW, 12.5A, Din-rail Mount Heating Regulator RE-PR1-F-6, 25A, Din-rail Mount Heating Regulator Accessories RE-PR1-F15102 Replacement fuse for RE-PR1-F-1.5 RE-PR1-F15103 Replacement fuse for RE-PR1-F-3 RE-PR1-F11307 Replacement fuse for RE-PR1-F-6. The products referred to in this data sheet meet the requirements of EU 2004/108/EC and 2006/95/EC

Page 3 of 5 SAFETY REQUIRMENTS & ADVICE SHEET Introduction The objective of this leaflet is to provide information to ensure that the safety of the person(s) installing or maintaining the equipment is not compromised and its location and method of installation does not endanger others, either during or after installation. Customers should be aware of the Health and Safety at Work Act 1974 (HSW 1974) and the EC Provision and Use of Work Equipment Regulations 1992 (PUWER). Both are available from the Health and Safety Executive (HSE) publications, within the UK. Installation CE Directives These are European regulations which apply to our industry. They affect the equipment emissions and immunity to Radio Frequency Interference (RFI) and various elements of safety for electrical equipment. The European Community CE Directives that mainly concern Sontay Ltd are the Low Voltage Directive (LVD) and the Electromagnetic Compliance Directive (EMC). A Declaration of Conformity may be supplied with the product or supplied on request. Torque Settings Good working practises must be adhered to ensuring appropriate electrical and mechanical installation. This would include the mechanical fixing of potentiometer bushes and electrical set screw and/or pillar connections. These Electrical Connections and Mechanical Fastenings must not be over tightened. We would recommend a typical torque setting of 1 to 5Nm. For specific product information, see appropriate product data sheet, where applicable. Cooling Requirements The use of an additional heatsink (this could be a conductive panel) suitably attached or mounted with the unit, will help to dissipate heat away from the device(s). An alternative or additional method would be forced air-cooling (using a fan), to assist the natural convection of airflow over an existing heatsink within the unit. The product fins should be mounted in line with the forced and/or natural airflow. The equipment s environment and its initial ambient temperature also need to be considered, as this could have an adverse effect on the overall operating conditions. Fusing We recommend that semiconductor, fast acting to BS88 IEC 269, type fuses or circuit breakers (Semiconductor - MCB) should be used for unit and/or device protection. The appropriate maximum load current should be known to elect the required SCR fuse or Z curve MCB, but must not exceed the equipment rating. The I² t (A² s) rating of the selected fuse must be less than that of the equipment so as to protect the equipment s discrete device. Further appropriate fusing may be required for protection of the unit supply using standard fuse links and holders. Failure to address these requirements and the use of incorrectly selected fuses may cause the equipment to fail. Earthing The protective conductor terminal of the equipment must be utilised at all times and bonded to a good Earth (ground). The earth bonding (strapping) leads of any combined equipment should be as short as possible and be substantial, i.e. at least rated higher than the equipment s load. For further information, refer to BS7671. Following these simple guidelines will ensure optimum use of any appropriate filter circuits which may be required. Insulation (over-voltage category) and Protection from electric shock Classification of Equipment All equipment, unless otherwise stated, is rated to CLASS II Insulation (Over-voltage category) and CLASS I (Protection category). Maintenance Before any servicing is carried out, reference should be made to appropriate installation instructions, drawings and labelling which may come with the equipment. Personnel should switch off the unit supply before accessing or removing any safety cover and be aware of hazardous live parts.

Page 4 of 5 Location & Ventilation: The unit is designed to be installed on DIN rail in an electrical control panel, and should be installed with the heatsink cooling fins in a vertical plane. Allow a minimum of 100mm between units on the vertical axis. The maximum ambient of 65 C should not be exceeded. Where necessary control panels & enclosures should be ventilated with a fan. Load Supply: It is recommended that a load break switch and a break contactor is installed in the load supply. The supply to the contactor coil should be interrupted by an over-temperature thermostat located in the heater battery and also upon detection of airflow loss. Over Temperature Monitoring: The RE-PR1-F is fitted with a thermal protection device to protect against over temperature. The unit will automatically switch off the load in the event of the heatsink temperature exceeding safe limits (90 C ±1 C). Once the temperature has fallen to a safe level (85 C ±1 C) the load will be switched on again if the supply is still present. Caution: During the course of normal operation metal parts, in particular the heatsink may get very hot. Fuse Back-up Protection: The RE-PR1-F are fitted with fuses to provide back-up protection. To select the required fuses or Z curve MCB s (semiconductor circuit breakers), the load current should be known, but not exceed the electric heater battery rating. Load Considerations: The RE-PR1-F series of power controllers are designed for resistive type loads only. Capacitive, or unusual heating loads such as Molybdenum, Platinum or Tungsten, (which can have a 10:1 hot to cold resistance ratio) are not suitable. Fitting Protective Guard to RE-PR1-F-6: 1. Make all wiring connections as shown on page 3 before fitting the protective cover. 2. Ensure that all power is disconnected before carrying out the installation of the protective cover on the RE-PR1-F-6. 3. Drill a 2.6mm hole in the position shown below. 4. Slide the protective cover onto the heatsink assembly. 5. Fit the No.4 self-tapping screws that are supplied to hold the cover in place.

Page 5 of 5 Installation: 1. The RE-PR-F should only be installed by a competent, suitably trained technician, experienced in installation with hazardous voltages. (>50Vac & <1000Vac or >75Vdc & 1500Vdc) 2. Ensure that all power is disconnected before carrying out any work on the RE-PR-F. 3. Maximum cable size is 2.5mm² (4mm² for ), care must be taken not to over tighten terminals. 4. When mounting the RE-PR-F care should be taken not to stress the PCB when fitting to the DIN rail. If it is necessary remove the module from the DIN rail, be sure to use a flat bladed screwdriver to release the DIN clips. 5. The RE-PR1-F is self-powered from the 230Vac load input, so a separate 24V supply is not required. 6. When installation is complete, the protective guard must be replaced on the version. The 1.5 & 3kW versions are fitted with protective shrouds on the fuse. Caution: When monitoring 230Vac inputs, dangerous voltages are present on the terminal blocks and on the printed circuit board. Care MUST be exercised to avoid coming into contact with live components. Connections: SW1 0-10Vdc 0-5Vdc Status LED 5V Out Live Neutral Earth Safety earth must be connected Heater 0V 0-10 /0-5Vdc Control signal input Whilst every effort has been made to ensure the accuracy of this specification, Sontay cannot accept responsibility for damage, injury, loss or expense from errors or omissions. In the interest of technical improvement, this specification may be altered without notice.