MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Similar documents
Control Circuit Protection

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Miniature Circuit Breakers

max pole for t=15 ms

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Jtec 10kA Miniature Circuit Breaker

Thermal-magnetic Miniature Circuit Breaker 4230-T...

MCB s RCD s & FUSE HOLDERS

DX³ 4-pole RCBO 6000 A/10 ka

MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics

and other modular devices for low voltage installation

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

MINIATURE CIRCUIT BREAKER

Motor Circuit Breakers C4

Miniature Circuit Breaker

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

3 - Protection components Motor circuit-breakers

DPX earth leakage DPX 3 -I earth leakage

New DX 3 High rating & breaking capacity

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Miniature circuit breakers

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

NB1 Miniature Circuit Breaker

D509E. Manual Motor - Starters

Jtec 489 UL489 Branch Circuit Breaker

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

E s h o r t c ir c u it Wit h s t AND r At ing s f o r r -s er ies s u ppl ement Ar y pr o t ec t o r

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Series KTU7 UL489 Molded Case Circuit Breakers

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Technical data for manual motor starters Type MS325

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Series KTU7 UL489 Molded Case Circuit Breakers

Cat N 3. OVERALL DIMENSIONS

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Technical Information

US CATALOG. Miniature Circuit Breakers

Bulletin 190-M Compact Starters. Selection Guide

XT IEC Power Control Manual Motor Protectors

Miniature Circuit-Breakers (MCBs)

Selection Guide. Control Circuit and Load Protection

R.C.B.O. SP / 1 module

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

RESIDUAL CURRENT CIRCUIT BREAKER

Components for EEx e Panels

Thermal Overload Relays - WEG RW Series, 2 Pole

Technical Journal September 2012

Phase + Neutral, neutral on right side

Thermal overload relays Type TA Class 10

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Selection Guide Motor Control Device Solutions

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

UMBW-UL489 and UL1077 Listed

DPX Magnetic only

System pro M compact Miniature Circuit Br eakers Description Features

Korea Product Guide - Circuit Protection & Control X-Pole Series Miniature Circuit Breakers PL10 & PL9. Advanced design provides reliable protection

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Thermal Overcurrent Circuit Breaker 3120-F...

Protection components

ELFA E90S MINI BREAKERS

US CATALOG. Miniature circuit breakers

cor Long Run Experience

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

FMotor Circuit Controllers

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Low Voltage A GE Power Controls Company. General catalogue

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

PD-Series Ground Fault Circuit Protection

DX³ RCCBs - ID 4P up to 100 A

Power systems Protection course

Essential equipment for all your requirements

4 - Miniature controls

Series L9 UL-489 Miniature Circuit Breakers

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

DX³ RCBO 6000A Phase + Neutral, neutral on left

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

LCIRCUIT BREAKERS. Jtec UL (Motor Disconnect) General Information...L2 Trip Curves & Dimensions...L3

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

DPX Electronic + earth leakage

Residual Current Circuit-breaker (RCCB) FH 200 Series

COMPLETE SOLUTIONS FOR POWER PROTECTION

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

RX 3 M.C.B A up to 63 A

Phase + Neutral, neutral on left side

MC FRAME SIZE 1 / UP TO 160A

QUALITY ASSURANCE & DOCUMENTATION

Transcription:

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS MANUFACTURED IN THE EU EUROPEAN QUALITY 1, 2 & 3 POLE MCB s TRIPPING CURVES C & D CURRENT RATINGS 1AMP TO 63AMPS 10KA BREAKING CAPACITY ADD ON AUXILIARY CONTACTS 2 POLE RCBO s COMBINED MCB / RCD 1, 2 & 3 POLE DINE RAIL MOUNTED FUSE HOLDERS PIN TYPE & FORK TYPE BUSBAR AVAILABLE 1 PHASE & 3 PHASE T e l : 0 1 2 7 6 3 2 7 7 7 F a x : 0 1 2 7 6 3 1 9 7 7 7

ETIMAT 10KA Characteristic C TRIPPING TIME SECONDS MINUTES C - Characteristic 1 1,2 1,4 1,6 1,8 2 2,5 3 4 5 6 7 8 9 10 12 15 X RATED CURRENT Characteristic D 10000 1000 D - Characteristic MINIATURE CIRCUIT BREAKERS, MCB S ETIMAT 10 MCB s are produced according to the latest international standards EN60898 IEC60898 and IEC60947-2. These MCB s are for protection and control of circuits against overloads and short circuits in commercial and industrial applications Characteristic C is recommended for industrial applications where higher starting effects are expected e.g. transformers, motors and lighting installations. Thermal release at 1.13 to 1.45 x In. Magnetic breaking release at 5 to 10 x In. Characteristic D is recommended for heavy industrial applications where very high starting effects are expected, e.g. m otors starting under load. Thermal release 1.13 to 1.45 x In. Magnetic breaking release 10 to 20 In. TRIPPING TIME SECONDS 100 10 1 0.1 0.01 0.001 1 1.5 2 3 4 5 10 20 30 40 50 X RATED CURRENT Specifications Voltage Ue: 230/400V 60V DC per pole Frequency: 50/60Hz Poles: 1, 2 and 3 poles Breaking capacity: 10KA Electrical Life: >20 000 operations Mechanical Life: >1 000 000 operations Terminal Sizes: All 25mm 2

ETIMAT 10 MINIATURE CIRCUIT BREAKERS, MCB s SINGLE-POLE MCB s TWO-POLE MCB s THREE-POLE MCB s Order Current Breaking Code Rating Capacity C - C H A R A C T E R I S T I C TSC- 101 1 10kA TSC- 102 2 10kA TSC- 104 4 10kA TSC- 106 6 10kA TSC- 110 10 10kA TSC- 116 16 10kA TSC- 120 20 10kA TSC- 125 25 10kA TSC- 132 32 10kA TSC- 140 40 10kA TSC- 150 50 10kA TSC- 163 63 10kA D - C H A R A C T E R I S T I C TSD- 101 1 10kA TSD- 102 2 10kA TSD- 104 4 10kA TSD- 106 6 10kA TSD- 110 10 10kA TSD- 116 16 10kA TSD- 120 20 10kA TSD- 125 25 10kA TSD- 132 32 10kA TSD- 140 40 10kA Order Current Breaking Code Rating Capacity C - C H A R A C T E R I S T I C TSC- 201 1 10kA TSC- 202 2 10kA TSC- 204 4 10kA TSC- 206 6 10kA TSC- 210 10 10kA TSC- 216 16 10kA TSC- 220 20 10kA TSC- 225 25 10kA TSC- 232 32 10kA TSC- 240 40 10kA TSC- 250 50 10kA TSC- 263 63 10kA D - C H A R A C T E R I S T I C TSD- 201 1 10kA TSD- 202 2 10kA TSD- 204 4 10kA TSD- 206 6 10kA TSD- 210 10 10kA TSD- 216 16 10kA TSD- 220 20 10kA TSD- 225 25 10kA TSD- 232 32 10kA TSD- 240 40 10kA Order Current Breaking Code Rating Capacit C - C H A R A C T E R I S T I C TSC- 301 1 10kA TSC- 302 2 10kA TSC- 304 4 10kA TSC- 306 6 10kA TSC- 310 10 10kA TSC- 316 16 10kA TSC- 320 20 10kA TSC- 325 25 10kA TSC- 332 32 10kA TSC- 340 40 10kA TSC- 350 50 10kA TSC- 363 63 10kA D - C H A R A C T E R I S T I C TSD- 301 1 10kA TSD- 302 2 10kA TSD- 304 4 10kA TSD- 306 6 10kA TSD- 310 10 10kA TSD- 316 16 10kA TSD- 320 20 10kA TSD- 325 25 10kA TSD- 332 32 10kA TSD- 340 40 10kA ADD ON AUXILIARY CONTACT BLOCK FOR MCB s PS ETIMAT is an auxiliary switch used for remote signalling of the MCB to which it is fixed. 22 12 14 Specifications 21 11 Contacts: 1 Amp at 110V DC Contacts: Width: Max. 6 Amps at 230V AC or 1NO & 1NC 1/2 module (9mm) TYPE PS ETIMAT 10 Also available are Shunt Trip Release Modules and Undervoltage Release Modules. Please consult the sales office for further information.

RCBO s COMBINED MCB/RCD TWO POLE Providing the combined advantage of protection against earth leakage faults with short-circuit protection. Specifications Max voltage: Breaking capacity: Tripping curve: Sensitivity: Ambient temperature: Width: Standard: 230V 10KA C 30mAmps. -25 to +40ºC 36mm EN61009 Dimensions Type Rated Current Characteristics Amps 45 92 T KZS 2M 6C 6 C KZS 2M 10C 10 C KZS 2M 16C 16 C KZS 2M 20C 20 C KZS 2M 25C 25 C KZS 2M 32C 32 C KZS 2M 40C 40 C KZS 2M... replaces old P/No. TCU... 44 54 35 2 pole & 4 pole RCD s also available, current ratings from 16Amps to 100Amps and sensitivity 30mA to 500mA, please consult the sales office for further information. Pin Type 1, 2 3 phase solid copper conductors with pin attachments for connection of NORM modular components e.g. MCB s and RCD s. 17,5 CONNECTING BUSBAR Type Length mm Modules Area mm 2 S I N G L E P H A S E P I N T Y P E S1L 1000/16 1000 56 16 T H R E E P H A S E P I N T Y P E GA-1 Fork Type 1, 2 3 phase solid copper conductors with fork attachments for connection of NORM modular components e.g. MCB s and RCD s. 17,5 S3L 1000/16 1000 56 16 S I N G L E P H A S E F O R K T Y P E G1L 1000/16 1000 56 16 T H R E E P H A S E F O R K T Y P E G3L 1000/16 1000 56 16 Maximum permanent current on above busbars 80Amps GA-1 END PROTECTOR FOR THREE-PHASE BAR GA-1 End protector

DIN RAIL MOUNTED FUSE HOLDERS VLC10 (10x38mm) max 32Amp VLC14 (14x51mm) max 50Amp VLC22 (22x58mm) max 100Amp 1,2 & 3 Pole Type: VLC10 for fuse links 10x38mm, max operational current 32 Amps @ 690VAC Rated making & breaking capacity: 75 Amps Type: VLC14 for fuse links 14x51mm, max operational current 50 Amps @ 690VAC Rated making & breaking capacity: 150 Amps Type: VLC22 for fuse links 22x58mm, max operational current 100 Amps @ 690VAC Rated making & breaking capacity: 150 Amps S t a n d a r d s IEC 60947-1 IEC 60947-3 A d v a n t a g e s Materials resistant to high temperatures Silvered contact parts Low own heating Fixing to standard din rail of 35mm (EN50022) 25mm terminals VLC10 35mm terminals VLC14 50mm terminals VLC22 VLC10 & VLC14 UL, CSA approved CE marked Possibility of sealing in switched ON condition Type Description Width x Height VLC10 1P 1 pole 17.5 x 81mm VLC10 2P 2 pole 35 x 81mm VLC10 3P 3 pole 52.5 x 81mm VLC14 1P 1 pole 27 x 94mm VLC14 2P 2 pole 54 x 94mm VLC14 3P 3 pole 81 x 94mm VLC22 1P 1 pole 35.5 x 120mm VLC22 2P 2 pole 71 x 120mm VLC22 3P 3 pole 107 x 120mm

NORTONICS LIMITED The Old Bakery, 265 Yorktown Road, Sandhurst, Berkshire GU47 9BN Telephone: 01276 32777 Fax: 01276 31977 Website: www.nortonics.co.uk E-mail: sales@nortonics.co.uk