ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

Similar documents
SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

Subject: Pneumatic Training Kit with portable Air Compressor

BASIC PNEUMATIC & ELECTROPNEUMATIC TRAINING SYSTEM

Electro Pneumatic WorkStation Scientech 2470

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

Electro Pneumatic Workbench Scientech 2470

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Industrial Pneumatic Systems Syllabus [Detailed]

Z1 B1 B2 Z2 B3 B4. Steuerteil + 24 V. Leistungsteil K1 K2 K1 K2. Practice for Professionals Electropneumatics Trainee s manual. Version 1.

Automatic Control System PS Pneumatic Training System. Features

PNEUTRAINER-400 Pneumatics - Electropneumatics

MF100BH (BASIC HYDRAULICS TRAINER) PARTS LIST CATALOG APRIL 2013

PNEUTRAINER-200 Pneumatics - Electro-pneumatics

Pneumatics Electropneumatics

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Mechanical Engineering

Input, Control and Processing elements

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

Courseware Sample F0

Transmitters: Relay Valve VR4151/4152

SAP E & C PLC PROGRAMMING TRAINER KIT (PRODUCT CODE: PCST 14)

January 2007 Approval Guide Fixed Extinguishing Systems 5-57

6081 Pneumatics Training System

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Actuated Valves PRICING

6080 Hydraulics Training System

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

Pneumatic Control System

On-off/soft-start valves HE/HEE/HEP/HEL, D series

3 Port Solenoid Valve

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

Transmitters: Relay Valve

Learning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1

Control block VOFA with safety function

Solenoid valves VUVS/valve manifold VTUS, NPT

Fire control. Electromagnetic fire Door Retainers. Available Models

SECTION B1: MACHINE COMPONENTS

Vacuum pump system type

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

PD3/PDV3-20A/25A/40A Series

SVR10 SVA10. External Pilot air specification. Conventional specification 0 ~ 0.7. Compact, yet keeps large capacity.» Limited space can be utilized.

Didactic and technological innovation at the service of training in pneumatics and electro-pneumatics have resulted in the creation of the

PNEUMATIC & HYDRAULIC SYSTEMS

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

SECTION B: SYSTEM OPERATING COMPONENTS

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

On-off/soft-start valves HE/HEE/HEP/HEL, D series

ME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.

Table of Contents. Table of Contents Pneumatik / Hydraulik

Zone Valves and Parts (Honeywell)

A system of lubricant dispensing devices (oil or grease) connected by piping to a central pumping unit that is operated automatically or manually.


Specifications. Fluid Ambient and fluid temperature ( C)

Body width of 10mm, Nl/min (49.08) 2W (Standard) Nl/min (78.52) 4W (U type: Large flow) Vacuum applications possible (up to 100kPa) 3 S.

PNEUMATIC POWER CYLINDER

LIMIT SWITCH Axiom - AX

Vacuum applications possible (up to 100kPa) Base mounted. Cylinder bore size (mm) Series CM2. Pressure: 0.5MPa Load ratio: 50% Cylinder stroke: 300mm

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

Cascade Master Series

Palletized Fixture Accessories

3 Port Solenoid Valve Pilot Operated Poppet Type. External pilot

! Contact our sales office regarding a delivery date or a price since this is a special model. Auto switch D-M9 series mountable

Chapter 10: Valves for Pipe Mounting

CONTROLS. Bray Pneumatic Actuators & Accessories. Technical Manual. A Division of BRAY INTERNATIONAL, Inc.

Solumatics Engineering (M) Sdn. Bhd. Water Solenoid Valve. Steam Solenoid Valve. 1 of 32

LIMIT SWITCH Axiom - AX

Electrohydraulics Advanced Level Workbook TP 602

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

EX Series. Electric Actuators for Ball and Butterfly Valves

pneumatic function fittings

Gateway Type Serial Transmission System

[You may download this article at: ]

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Solenoid valves VUVS/valve manifold VTUS, NPT

SV SOLENOID OPERATED

Actuators and directional control valves

CONDENSED CATALOG CC

General characteristics Operating fluid Compressed air or inert gas Conditions of use Operating pressure 30 to 20 PSI (2 to 8 bars). Fluid: Filtered a

4 Port Solenoid Valve

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

SOLENOID VALVES 300 SERIES INSTRUCTION MANUAL

Solenoid valves MFHE/Pneumatic valves VLHE

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

SERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES

A Fluid Power PNEUMATICS TRAINING SYSTEMS SERIES 6081

Model J Doc: J3/3740/01 Jan 2008

4 Port Solenoid Valve

Chapter 6 Pneumatic Logic Sensors and Actuators

Electrical Components

Chemical Injection Pumps and Products

Solenoid/pneumatic valves, ISO

DME Valve Gate Controls

V1504 Vertical Platform Lift OWNER S MANUAL

Pneumatic valves VUWS/valve manifold VTUS

LIMIT SWITCH Axiom - AX

Slide Freedom Automatic Spray Unit Item # 43200

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Transcription:

The Advanced Customized Electro Pneumatic Trainer (SAP 20B) is capable of being used to demonstrate the design, construction and application of electro-pneumatic components and circuits.

Objectives:- The components are capable of being mounted on an appropriate profile plate with grooves for secure and flexible positioning so that the components can be clamped firmly, quickly and safely through quick fix adaptors. Industrial components are used in the kit so that the students get hands on practical training in using industrial components. Technical Specification: - No. Item Name Technical Specifications 1 Profile Plates & Stand- The anodized Aluminium profile plate is the basis for training. All components fit securely & safely onto the profile plate with safe fixing arrangement. Grid Dimensions: 50mm, Size: 1000 700mm 2 Shuttle Valve (OR)- 1 No., The Shuttle Valve is switched through to the output by applying compressed air to one of the inputs (OR) function. Design type is OR gate (shuttle valve). Pressure range: (1-10 Bar) 3 Dual Pressure Valve (AND)- 4 One way flow Control Valve Assembly- 5 Pressure Sequence Valve assembly- 1 No., the dual-pressure Valve is switched through to the output by applying compressed air to both the inputs (AND) Function. Design type is AND Gate (Dual Pressure Valve). Pressure Range: (1-10 Bar) 1 No., the One - way flow control valve is a combination of flow control valve & a nonreturn valve. The cross section of the restrictor can be set by means of a Knurled screw. Design type is combined flow control Valve. Pressure range (0.5-10 Bar) 1 No., The pressure of the control signal can be set by means of the pressure setting screw (variable). Design type is Poppet Valve with return spring. Operating Pressure range (1.8 8 bar). Control Pressure range - (1 8 bar) 6 Single Acting Cylinder- 1 No. : Design type is Piston Cylinder.Operating Pressure 10 bar. Stroke length 100mm 7 Double Acting Cylinder- Design Piston Cylinder. Operating Pressure 10 bar, Stroke Length Max 100 mm 8 Manifold Assembly- 1 No., Manifold with 6 (2 3) Hex-Ball Valve. A common manifold for plastic tubing allows supply of compressed air to the control via six individual ports (for plastic tubing PUN 4 0.75) 9 Filter regulator with Gauge- Filter control valve with pressure gauge, gate valve, quick push-pull connectors & quick couplings mounted on a swivel support. The filter with water separator removes dirt, pipe sinter, rust & condensed water. The pressure control valve regulates the supply. Air pressure to the set operating pressure & compensates pressure fluctuations. The filter bowl has a condensate drain valve. The shutoff valve ventilates & vents entire control. Input pressure Maximum (16 bar),output pressure Max 12 bar, grade of filtration 40 mm approx., Connector G 1/8, / PU 4 10 Relay, Three fold- 1 No., the device has three relays with terminals and two buses for power supply. Contact set Single change-over switches, Contact load maximum 5 A 11 Signal Input, Electrical- 1 No., The device contains an illuminated push-button switch (control switch) & two illuminated push buttons (momentary contact switches) with terminals & two buses for power supply. Contact set- 2 makes, 2 breaks, Contact load- max 1A. 12 Indicator & Distributor Unit, electrical- 1 No., The device contains an acoustic indicator and four lamps with terminals and three buses for power supply. Through-contact socket pairs per lamp allow the element to also be used as a Distributor.

13 Proximity switch with attachment- 2 No. : The Proximity switch consists of a sensor, the mounting kit and the cable. This proximity switch gives a signal when it detects a metal. The status is indicated by an LED. Switching Voltage 24 VDC, Switching current max. 200 ma, Switching Power 6 W approx, switching accuracy - ±0.1mm 14 Equipment Tray- 1 No., MS powder coated tray with slots for placing components to be supplied with Electro-pneumatic supplementary kit. 15 5/2 way single sided Solenoid Valve with LED- 16 5/2 Solenoid Valve, Double sided with LED- 17 Pneumatic Electric convertor- 18 Limit Switch, Left Actuated- 19 Limit Switch, Right actuated- 1 No., The status is indicated by an LED on the housing. The valve is equipped with a manual override. Pneumatic Technical data: Design type is spool valve, pilot controlled with return spring, Pressure range: 250-800 KPa (2.5-8 bar), Electrical Technical data: Power consumption 1.5 W 1 No., The statuses are indicated by LEDs on the housings. The valve is equipped with two manual overrides. Pneumatic Technical Data: Design-spool valve with pilot control, Pressure range 150-800KPa (1.5-8 bar) Electrical Technical Data: Power Consumption 1.5 W 1 No., The pneumatic electric convertor can fulfill 3 functions: Pressure Switch, Vacuum Switch and Differential Pressure Switch. Pneumatic Technical Data- Pressure Ranges: Pressure Switch connector, P1: 0.25 to 3.5bar, Vacuum Switch: -0.2 to -0.8 bar, Differential Pressure Switch: Connector, P2 - (-0.95 to 3.5 bar) 1 No., The electrical limit switch comprises a mechanically operated micro-switch. When the roller lever is pressed, for example, by control cam of a cylinder, the microswitch is actuated. The circuit is closed or opened via the contacts. The micro-switch can be wired as a normally open or normally closed or changeover contact. Contact load: maximum 5A, switching frequency: maximum 200Hz, Reproducible accuracy: 0.2mm, Switch travel: 2.7 mm, Actuator force: 5N 1 No., The electrical limit switch comprises a mechanically operated micro-switch. When the roller lever is pressed, for example, by control cam of a cylinder, the microswitch is actuated. The circuit is closed or opened via the contacts. The micro-switch can be wired as a normally open or normally closed or changeover contact. Contact load: maximum 5A, switching frequency: maximum 200Hz, Reproducible accuracy: 0.2mm, Switch travel: 2.7 mm, Actuator force: 5N 20 Plug in adapter- For mounting components with plug-in foot on the aluminum profile plate. 21 Power Supply Unit- 1 No., Input Voltage: 230 / 115 VAC (47-63 Hz.), Output Voltage: 24 V DC, short circuit proof, output current: Max. 4.5 A, Connection Cable 3m 22 3/2 Solenoid Valve, Single with LED- 1No. : The status is indicated by an LED on the housing. The valve is equipped with a manual override. Pneumatic Technical data: Design type is spool valve, pilot controlled with return spring, Pressure range : 250-800 kpa (2.5-8 bar), Electrical Sufficient shall be supplied for branching of the tubing for making of the circuitry 23 Quick Push-Pull connectors- 24 Plastic Tubing- PUN 4 0.75, Exterior Diameter-6mm, Interior Diameter- 4mm, Transparent 10mtrs/Blue-10mtrs 25 Set of molded Cables- 1.5 Meter (2 core) - 4 No. 1.5 Meter (3 core) - 3 No. 1.5 Meter (1 core): Red- 05 Nos, Black- 05 Nos. BS5 Patch cords: Red - 5 Nos.(Approx. 300mm)., Black - 5 Nos.(Approx.300mm) 26 Hand Lever Operated Valve 27 5/2 Push Button Operated Valve 3/2 Hand Lever Operated Valve -1 No. & 5/2 Hand Lever operated Valves-1 No. each Connection: ¼ Connection. Design type is spool valve. Actuation using Hand Lever. 1 No. Connection: ¼ Connection. Design type is spool valve. Actuation using Push Button.

28 Quick Exhaust Valve 1 No. Connection: ¼ Connection 29 Pneumatic Motor Unidirectional, Air pressure: 0-90 psi. 30 3/2 Pilot operated valve 3/2 way Valve, ¼ Connection 31 PLC Panel - Make: Siemens Logo / Equivalent, Digital Input: 8, Digital Output: 4 Input / Output LED indication on front Facia of the panel. 32 Electronic Timer 1 No., Power Supply -24VDC with C,NO,NC terminals 33 Time Delay Valve 1 No. Connection: ¼ Connection 34 Air Compressor Tank capacity: 25 Liters, Discharge: 2 CFM, Motor: 1 H.P. 230 V AC Operated, Working Pressure: 5-6 kg/cm 2 Range of experiments: Study of Advanced Electro Pneumatic Trainer. Study of Self Reciprocation of Single Acting Cylinder by Using Electric Limit Switch & 3/2 Solenoid Valve Study of Self Reciprocation of Double Acting Cylinder by Using Proximity Switch & 5/2 Double Sided S.V. Study of Self Reciprocation of Double Acting Cylinder by Using Proximity Switches & 5/2 Single Sided S.V. Study of AND Valve (Dual Pressure Valve) Study of Shuttle Valve (OR Valve) Study of Quick Exhaust Valve Study of operation of Hand Lever Valve (3/2 & 5/2 DCV) Study of operation Of 5/2 Push Button Valve Study of operation Of 3/2 Single Pilot Operated Valve Study of Pressure Sequence Valve Study of Flow Control Valve & Pneumatic Motor Study of P To E Converter Study of using Signal Input Electrical Box, Relay Three Fold, Indicator & Distributor Unit Study of Pneumatic & Electro-Pneumatic Circuits. Study of PLC Based Actuation of Solenoid Valves Study of Time Delay Valve Study of Electronic Timer Features: - Function & identification of Electro-pneumatic components & their symbols. Direct and indirect manual controls, stroke dependant controls, time dependant and pressure dependant controls with time delay, pressure sequence valves. Design & function of a electro-pneumatic System. Functional diagrams. Logic AND/OR function to start signals. Application and fault findings of Electro Pneumatic controls. Pneumatic power section Electric control section. To empower students to design their own circuits. The kit is modular and upgradeable. Training literature Instruction & operation manual, troubleshooting & maintenance tips will be provided in soft copy as well as hard copy format

System Dimension: 4 Ft. (L) X 2 Ft. (W) X 6.25 Ft. (H) Services Required: Compressed clean, dry air supply at 4-5 Kg/cm². Electric Supply of 1φ 230 VAC motor. Note: All descriptive matter and illustrations are intended to give only a general idea of the equipment Detailed specifications may be altered at the company s discretion without any notice.