Series Pilot Operated Pressure Relief Valves 0810C

Similar documents
0810C. Valve Group Series. Farris Engineering Pressure Relief Valves

304C. Valve Group. Series Farris Engineering Pressure Relief Valves

494C. Pilot Operated Pressure Relief Valves. Series Pilot Operated Pressure Relief Valves. Farris Engineering Pressure Relief Valves

* Contact your sales representative for compliance to NACE MR or later requirements.

Crosby Series 800 and 900 OMNI-TRIM Pressure Relief Valves. Flow Control

* Contact your sales representative for compliance to NACE MR or later requirements.

Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.

Spring loaded Thermal Relief Safety Valves, manufacturers standard Medium and high pressure

Pressure Relief Valves MPV Series. Consolidated Pilot Operated Safety Relief Valve

2900 MPV Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

Type 441 CATALOG. Flanged Safety Relief Valves. The-Safety-Valve.com

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

2900 MPV Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

3900 MPV Flanged Valves comply with:

Series Pressure Relief Valves 197C

CROSBY J-SERIES DIRECT SPRING PRESSURE RELIEF VALVES

SV80H Safety and Relief Valves

3900 Pilot Operated Relief Valve

Compact. performance. Threaded Safety Relief Valves. Series 437 Type Series 459 Type CATALOG.

197C. Valve Group. Series Farris Engineering Pressure Relief Valves

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Consolidated* 3900 MPV Series Pilot-Operated Safety Relief Valve

Consolidated* Series

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

394C. Series 6400/6600. Safety Valves for Power Boiler Service

High. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

Models 910, 911, 916, 917, 920, 921, 927 ASME Section VIII, Air/Gas/

2900 Pilot Operated Relief Valve

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Anderson Greenwood Low Pressure POPRV Catalog Series 90 and 9000 Pilot Operated Pressure Relief Valves

Series Maintenance Manual. Technical Manual 802T R2

Table of Contents. 1900/P3 Series Exposed spring design - The spring in this design is exposed for atmospheric cooling. D through T orifice sizes.

ANDERSON GREENWOOD LOW PRESSURE POPRV CATALOG SERIES 90 AND 9000 PILOT OPERATED PRESSURE RELIEF VALVES. Product overview

Pilot operated pressure relief valves.

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

F84L & F88 Series Spring-Operated Liquid Service Pressure Relief Valves

Anderson Greenwood Series 200/400/500/700/800 Pilot Operated Relief Valves

BIRKETT SAFESET SERIES PILOT OPERATED SAFETY RELIEF VALVES

High. Efficiency. Facts. LESER worldwide. Pilot Operated Safety Valves. Series 810 Pop Action US Units. The-Safety-Valve.com. The-Safety-Valve.

Models 912, 913, 918, 919 ASME Section VIII, Steam/Air/Gas/Liquid, UV National Board Certified. Also available for Vacuum Service.

Sarasin-RSBD STARFLOW SAFETY RELIEF VALVES. Sarasin-RSBD CONTENTS. Starflow Introduction 4-5. Description 6-7. Design Information 8-12

Model 1415 TOSACA TECHNICAL DATA SHEET. Construction and materials. Technical information

KINGSTON. Model 710. Side Outlet Safety Relief Valve. Manufacturing reliable industrial valves for industry since 1908.

LESER LLC LESER S.A.R.L.

Anderson Greenwood Series 5100 Pilot Operated Pressure Relief Valves

115 Series, Needle Valves, Single Block, Male x Male

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Products and Services for the Energy Industry

Pilot-Operated Safety Relief Valves

TOSACA. Catalogue

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Direct-operated, Back Pressure Regulating Valve. Features

MK508UBS Series. Back Pressure Regulator MK508UBS. Threaded or Flanged Connections Carbon Steel, Stainless Steel & Alloy Construction.

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C

API CATALOG. Flanged Safety Relief Valves Series 526. The-Safety-Valve.com

SAFETY relief VALVE SERIES # 006 DESIGN FEATURES HARSHAD ENGINEERING WORKS HARSHAD ENGINEERING WORKS TECHNICAL DATA : ISO 9001 CERTIFIED COMPANY

POWER APPLICATION SSR-S1000

Series Pressure Relief Valves. Farris Engineering Products and Services 304C

Model RVL-20. Stainless Steel Low-Pressure Diaphragm Relief Valve

T205 Series Tank Blanketing Regulators

Palanca manual Lifting device. Obturador o-ring Disc o-ring 28 Soft seat Viton / PTFE Metal. Inlet Outlet Orifice Area A B C Weight

High Capacity Direct Operated Pressure Reducing Valve. Features

Series Safety Valves for ASME Section I and VIII Boiler Applications 1005C

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Kunkle Bailey 756 safety relief valve

Product overview. Technical data

Model BPS05-Npt-P. Plastic Back Pressure Regulator Valve

Delivering Peak Performance. High-pressure liquid and gas flow control solutions for the oil and gas industry s harshest environments

Installation Operation and Maintenance Instructions Model Contents

Kunkle Safety and Relief Products

ASME VSU series

Pressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated

Anderson Greenwood Series 400 Piston Pilot POPRV Installation and Maintenance Instructions

T205 Series Tank Blanketing Regulators

ANDERSON GREENWOOD. Before installation these instructions must be fully read and understood.

Anderson Greenwood MLCP. Modulating Large Capacity Pilot Valve

Fisher YD and YS Control Valves

Pressure Relief Valves Series. Consolidated Safety Valve

Product Description. Product Description. Materials Series 810, 820 Main Valve

Series Maintenance Manual. Technical Manual 197T R2

Pressure Reducing, Differential and Back Pressure Regulating Valves Spring Loaded Dome Loaded Pilot Actuated

API Flanged Safety Relief Valves Series 526 API CATALOG. LESER worldwide. The-Safety-Valve.com. The-Safety-Valve.com

Model 5400 / 5450 Control Valve

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

Item Component Remarks Type 4393 Type ), SA Vulcanized soft seal disc SA L SA L

Type 526 IC CATALOG. Flanged Safety Relief Valves API Series. The-Safety-Valve.com

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

Fabricated Duplex Strainers

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

Installation, Operation & Maintenance Manual

Safety Relief Valves Commanche Techmatic Controls

MR98 Series Backpressure Regulators, Relief and Differential Relief Valves

Reyco Series RL14, RL40, & RL41. Direct Spring Acting Safety Relief Valves for Gas, Liquid, and Steam Service

Cartridge Filter Housings Nowata A Series

SLK SERIES SAFETY VALVES

MERCER VALVE GENERAL INFORMATION THINK...MERCER FIRST MERCER VALVE CO., INC. AUTO SEAT TECHNOLOGY

SARASIN-RSBD Pilot Operated Pressure Relief Valve. Excellent Engineering Solutions. 71/76/78/86 Series

500 Series Adjustable Popoff & Inline Relief Valves.5 to 150 PSIG

High. Efficiency CATALOG. LESER worldwide. Pilot Operated Safety Valves LESER UK Bristol, United Kingdom

Transcription:

Series 00 Pilot Operated Pressure Relief Valves 00C

Numbering System To simplify the selection and specifying of Farris pressure relief valves, use the following type numbering system. The type numbering system is ideal as the digits which comprise a specific type number have a distinct significance. The digits describe the basic valve series, orifice, seat and internal construction, inlet temperature range, body, and spring material, inlet flange class as well as Code liquid design. D C Series Number Orifice Area Construction Temperatures & Materials Orifice Area, Sq. In. Area, Sq. mm C Elastomer O-Ring Letter Seat & Seals* API Actual API Actual D E F G H J K L M N P Q R T A 0.0 0. 0.07 0.0 0.7.7...0...0.0.0 0.0 0. 0.7 0. 0.7.0.0.70.000. 7.07.7 7.7. 0.7.77..0.0.07. 7 0 0 00 7 0 77 7 7 0 7 7 7 7 0 0 7 T PTFE O-Ring Seat & Seals (Main Valve Only) *For set pressures above 0 psig, main seat seal for all valves with 00#, 00# and 00# inlet flanges use PTFE. Designation Inlet Temperature Range F Body & Cover Material Piston -0 to 0 Carbon Steel Stainless Steel -0 to + 0 Carbon Steel PH St. St. * -0 to -0* Stainless Steel Stainless Steel *Use for cyrogenic applications, S special material suffix is not required. Ordering Information To properly process your order and avoid delay please specify the following:. Quantity. Backpressure, Superimposed Constant and/or Variable and Built-up*. Inlet and Outlet Size. Required Capacity*. Farris Type Number*. Physical Properties of Fluid (Molecular Weight, Specific Gravity, etc.)*. Inlet and Outlet Flange Class and Facing. Accessories, if any required such as:. Materials of Construction, if other than Standard a) Manual or Remote Depressurizing b) Field Test Connection. O-Ring Seal Material (Viton is Standard) c) Reverse Flow Preventer 7. Set Pressure* d) Auxiliary Filter. Maximum Inlet Temperature* e) Any other. Allowable Overpressure*. Code Requirements, if any required 0. Fluid and Fluid State* *As a customer service we verify your selection and sizing. If this service is desired, you must include this information. General Notes: If valve modification or set pressure changes are required, consideration must be given to correct the nameplate and other data.

X - 0 /S Inlet Class Designation 0 ANSI Nominal Inlet Flange Class 0 00 00 00 00 00 Special Construction (If applicable) L Liquid Service (Standard Connections) X Air & Vapor Service (Oversize Connections) Y Liquid Service (Oversize Connections) D Air & Vapor Service (Dual Outlet) E Liquid Service (Dual Outlet) U Air & Vapor Service (Non-Standard API Connections) N Air & Vapor Service (Non-Standard API Connections) Inlet Facing O Special Raised Face, ANSI Std. ( to 0 AARH) Ring Joint ANSI Std. (Octagonal) H to AARH Raised Face (Inlet only) Although not applicable to the inlet facing only, the following first digit letters are also used: J to AARH (Outlet only) K to AARH (Inlet and outlet) X High Pressure Hub Connection Pilot PCF Snap Acting PCL Liquid Snap Acting PCM Modulating PCMS Steam Modulating HPCM High Pressure Modulating Options 0 No Options Test Gag Dual Pilot s Auxiliary Filter Manual Depressurizing Field Test Connection Reverse Flow Preventer 7 Pressure Spike Snubbers Remote Depressurizing F R V Field Test Connection with Indicator Remote Sensing Pilot Discharge Connected to Main Valve Outlet See table below for combinations Special Material S Complete St. St. PH St. St. Piston S Complete St. St. N N N NACE Compliant Carbon St. Body NACE Compliant PH St. St. Piston NACE Compliant Complete St. St. M * Complete Monel H * Complete Hastelloy C *Add "N" for NACE E.g. MN, HN, etc. Parts Replacement Valves: If an exact replacement valve is required, the valve type, size and serial number must be specified to assure proper dimensions and material being supplied. If a specific valve has become obsolete, a recommendation for the current equivalent, if any, will be made. Spare Parts: When ordering parts, use part names as listed in the bills of material in this catalog. Specify valve type, size and serial number. If serial number is not available, the original Farris factory order number will assist in our supplying the proper part and material. Springs: Order as an assembly to include spring with upper and lower spring buttons. Specify valve type, size, serial number, set pressure and back pressure, if any. Codes for Common Accessory Combinations Four Auxiliary Functions: Options, or F*, & A Combo Auxiliary Filter () & Field Test Connection ( or F)* B Combo Field Test Connection ( or F)* & Reverse Flow Preventer () E Combo Auxiliary Filter (), Field Test Connection ( or F)* & Reverse Flow Preventer () C Designation for combinations of options not listed * For Modulating s, Field Test Connection w/ Indicator (F) is automatically supplied, unless specified otherwise. General Notes:. Available on " and " inlet size valves only.. Historical designation for special inlet connections. This designation is obsolete.. Not available for all valve sizes or pressure classes. Please consult factory.. Duplex available upon request, contact factory.

Main Valve: Advantage Farris A 7 7 B C 0 A Two Piece Cover and Guide B Energized Piston Seal C Full Port Nozzle a a a b Valves with " inlet and larger Used for cyrogenic, steam and special service Built in conformance to ASME Code Section VIII for Air, Gas, Steam, and Liquid Service. ASME Code stamping not available on full port design in liquid service. Not available for liquid service

Snap Acting Pilot Features Snap-Acting, Non-Flowing: the PCF and PCL pilot controls are snap acting and non-flowing, minimizing the flow of process media through the pilot for reduced fugitive emissions and extended valve life. Full Stainless Steel Construction: resists corrosion and extends the life and versatility of the PCF and PCL controls. Adjustable Blowdown: allows setting blowdown at % of set pressure so that product loss is minimized and fugitive emissions reduced. Viton Seats and Seals: these chemical-resistant seals and seats enhance a control's life. Neoprene, ethylene propylene, silicone, and Buna-N soft goods are optional and extend temperature ranges from - F to 0 F. Kalrez available when maximum resistance to chemical attack is required. Contact factory for more information. Set Pressures and Blowdown Set at Pilot : in line service, settings and blowdown adjustments are completed quickly and easily without main valve intrusion. Subsequent reduction in product loss and fugitive emissions add to system profitability. Field Test Capable: the use of a field test connection allows cycling the pilot control without interrupting system protection or removing the valve from the line. Field testing verifies system integrity in accordance with the requirements of the Code. Remote Sensing Capable: when there is excessive inlet piping losses, or when the main valve must be installed at a different location on the protected system because of its service limitations, the pilot sensing line can be installed separate from the main valve. Suitable for NACE Service: for high quality materials of construction that meet NACE MR00 or MR07 service, refer to N trim for carbon steel body and N trim for stainless steel. 0 7 7 7 0 PCF(): Snap Acting Air, Gas, Vapor Service PCL(): Snap Acting Liquid Service 0 Built in conformance to ASME Code Section VIII for Air, Gas, and Liquid Service. ASME Code stamping not available on full port design in liquid service.

Modulating Pilot Features Modulating, Non-Flowing: the PCM, PCMS and HPCM pilot controls are modulating and non-flowing, minimizing the flow of process media through the pilot for reduced fugitive emissions and extended valve life. Full Stainless Steel Construction: resists corrosion and extends the operation and versatility of the modulating control. Blowdown: The modulating controls are a fixed blowdown pilot control with no external adjustment. Depending on fluid service, a blowdown of % to % is typical. Viton Seats and Seals: have a wide spectrum of chemical compatibility and temperature range to meet most applications and enhance valve life. Buna-N and ethylene propylene soft goods are optional and extend temperature ranges from - F to 0 F. Contact the Farris Factory for more information on other construction materials. Set Pressure Set at Pilot : in-line service and setting adjustments are done quickly and easily without main valve intrusion. Subsequent reduction in product loss and fugitive emissions adds to the system s profitability. Field Test Capable: using a field test connection allows cycling the pilot control without interrupting system protection or removing the valve from the line. Field testing verifies system integrity in accordance with the ASME Code. Remote Sensing Capable: when there is excessive inlet piping losses, or when the main valve must be installed at a different location on the protected system because of its service limitations, the pilot sensing line can be installed separate from the main valve. Suitable for NACE Service: for high quality materials of construction that meet NACE MR00 or MR07 service, refer to N trim for carbon steel body and N trim for stainless steel. 0 7 7 0 7 7 PCM(): Modulating to 70 psig PCMS(): Modulating to 70 psig 0 0 Air, Gas, Vapor and Liquid Service Air, Gas, Vapor, Liquid and Steam Service Built in conformance to ASME Code Section VIII for Air, Gas, Steam, and Liquid Service. ASME Code stamping not available on full port design in liquid service. HPCM(): Modulating 70 to 0 psig a 0a 0b Air, Gas, Vapor and Liquid Service