A-dec 300 LED Dental Light

Similar documents
Instructions for Use. Cascade 2615 Cart

Assistant s Instrumentation T

Instructions for Use. A-dec 4631 Duo Delivery System and A-dec 4635 Assistant s

Pre-Installation Guide Performer

A-dec 300 Delivery Systems

A-dec 311, 411, and 511 Dental Chairs Service Reference

A-dec 500 Delivery Systems

INSTRUCTIONS FOR USE. A-dec 311 Dental Chair

Instructions for Use. A-dec EA-30. Electric Motor System

A-dec 371L or 571L Dental Light on an A-dec 361, 362, or 363 Support Center INSTALLATION GUIDE

The A-dec Difference.

A-dec Dental Lights on an A-dec 300 Base Mount Post INSTALLATION GUIDE

A-dec 541 Delivery System and 545 Assistant s Instrumentation

Instructions for Use. A-dec EA-53 Electric Motor

A-dec O Clock Delivery System

A-dec Stools. A-dec 1601 Doctor's Stool A-dec 1621, 1622, and 1626 Assistant's Stools

A-dec 336 Delivery System on an A-dec 411 or 511 Dental Chair INSTALLATION GUIDE

The A-dec Difference Built for Life

The A-dec Difference Built for Life

The A-dec Difference Built for Life

Legendary A-dec Reliability

A-dec 570L Dental Light on a Non-DCS System INSTALLATION GUIDE

Instructions for Use. Performer. Dental Chair, Delivery System, Assistant s Instrumentation, Support Center with Cuspidor, and Light

A-dec 200 P RE-INSTALLATION GUIDE

The A-dec Difference. You can count on A-dec products to work consistently so you can stay focused on what matters most: the patient.

INSTALLATION INSTRUCTIONS CASCADE 3181 DUO DELIVERY SYSTEM TO PREFERENCECOLLECTION 5580

A-dec 311 Dental Chair and Related Systems

A-dec 200 Service Guide Contents

The A-dec Difference 5 YEAR WARRANTY. You can count on A-dec products to work consistently so you can stay focused on what matters most: the patient.

Legendary A-dec reliability

Cascade 3072 Delivery System INSTALLATION GUIDE

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE

A-dec LED Dental Light Head on a Demonstration Stand INSTALLATION GUIDE

A-dec 542 Side Delivery System I NSTALLATION GUIDE

INSTRUCTIONS FOR USE CASCADE 2615 CART AND 3175 WALL MOUNT

Owner s Guide PERFORMER III

Owner's Guide CASCADE 2671 DUO CART AND CASCADE 3171 DUO WALL-MOUNT

DECADE 1021 VAC BACK CHAIR

CASCADE CHAIR-MOUNTED HANDPIECE CONTROL WITH CASCADE MASTER SERIES TOUCH PAD

DECADE 1021 SOLO CHAIR

Regulatory Information and

Installation Operation Maintenance Troubleshooting Version2.1. Feb/09. Led II

Service Guide A-DEC SIMULATORS. Mobile (4810) and Stationary (4820)

LED OPERATORY LIGHT Instructions For Use

A-dec 2122/2132 Radius System on A-dec 511 Dental Chair I NSTALLATION GUIDE

Model C230 Pump Controller

DENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS IMPORTANT

Equipment Order Guide

USER MANUAL. Tides La Mer Treatment Table Rev A 3/28/19. *all tables shown with optional accessories and/or finishes

Performance Stools. Seating That s Made to Perform

System 3 ZB1PS Device Chassis. Operator s Manual

DENTAL LIGHT 300LED DENTAL LIGHT OPERATING INSTRUCTIONS IMPORTANT

Patient Chairs Operatories Delivery Units Lighting Seating Enhancements

182-LED Solar-Powered Motion Security Light. Owner s Manual

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

Quolis 5000 Operatory Ensemble

NEW GEN OWNER S MANUAL

120-LED Solar-Powered Motion Security Light

INSTALLATION GUIDE AND USER MANUAL

Radius Cuspidor (for Cascade 1040 or Decade 1011/1021 Chairs)

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

HYDRAULIC POWER PACK

Declaration of Conformity

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Intelligent Electronic Safe

Coleman Air C440-HVM 440 Amp Diversion Controller Version 3.2

Single COB LED Solar-Powered Motion Security Light

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

PRG 350 Series Stainless Steel Regulators

Level-Up (Towable) System

Elcometer 260. UV Pinhole Flashlight. Operating Instructions

2 TONNE TROLLEY JACK

4-LED Solar-Powered Pendant Shed Light

WT6000. Wearable Terminal Quick Start Guide MN

Smoke Leak Locator. User Manual. For Models: Pro S 25, Pro S 75, Pro S 500T, Pro S 600T, Pro S 1000HD. Ceramic Heating Technology

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

HLC CEILING MOUNTED DENTAL LIGHT. INSTALLATION and OPERATING INSTRUCTIONS. Rev.3

Water Trailer Series. WT5 Series Hitch Mount Brace Installation SAFETY REQUIRED TOOLS PARTS PREPARATION DECAL REMOVAL

AP250 Automated Projector

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

Door Edge Protection Film 36 inch

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

PRG 350 Series Stainless Steel Regulators

PSX2 (Power Stabilizing System) OWNER'S MANUAL

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

User s Guide CDCE-90-X SERIES. Conductivity Sensors. Shop online at omega.com SM

Swing Arm Magnifying Lamp

A-dec Service Guide Edition , 2003

Updated: October 2012

Instructions for use. Quick couplings RQ-03, RQ-04, RQ-14, RQ-24, RQ-34

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Item. Table 1. Circuit Breaker Replacement Kit 1. Item Part No. Description QTY. Remarks No. Includes. Items Items EE55781 WORK SAFELY!

FENIEX ROCKER PANEL Series MODEL # D-11971

TESTER SET SOCKET & VOLTAGE

INSTALLATION GUIDE AND USER MANUAL

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Micro-OPLC Installation Guide

Owner s Manual Nitrate Series Salt Based Filter System

Operation Manual. 355 Lighting System. Safety 2. Features 4. Component Overview 5. Controls & Indicators 6. Operation 7.

Transcription:

Instructions for Use A-dec 300 LED Dental Light Models 371L 378L

A-dec 300 LED Dental Light Instructions for Use Copyright 2018 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. A-dec Inc. shall not be held liable for any errors contained herein or any consequential or other damages concerning the furnishing, performance or use of this material. The information in this document is subject to change without notice. If you find any problems in the documentation, please report them to us in writing. A-dec Inc. does not warrant that this document is error-free. No part of this document may be copied, reproduced, altered, or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without prior written permission from A-dec Inc. Trademarks and Additional Intellectual Property Rights A-dec, the A-dec logo, A-dec Inspire, Cascade, Century Plus, Continental, Decade, ICX, ICV, Performer, Preference, Preference Collection, Preference ICC, Radius, and reliablecreativesolutions are trademarks of A-dec Inc. and are registered in the United States and other countries. A-dec 500, A-dec 400, A-dec 300, A-dec 200, and EasyFlex are also trademarks of A-dec Inc. None of the trademarks or trade names in this document may be reproduced, copied, or manipulated in any manner without the express, written approval of the trademark owner. Certain touchpad symbols are proprietary to A-dec Inc. Any use of these symbols, in whole or in part, without the express written consent of A-dec Inc., is strictly prohibited. Medicom and SafeShield are registered and unregistered trademarks of A.R. Medicom Inc. Regulatory Information Regulatory information mandated by agency requirements is provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. Product Service Product service is available through your local authorized A-dec dealer. For service information, or to locate an authorized dealer, contact A-dec at 1.800.547.1883 in the USA and Canada or 1.503.538.7478 worldwide, or visit www.a-dec.com. Product Models and Versions Covered in This Document Model Versions A-dec LED Dental Light Description 371L A Support-Side Mounted 372L A Radius Mounted 374L A Cabinet Mounted 375L A Wall Mounted 376L A Ceiling Mounted 377L A Track Mounted 378L A Simulator Mounted

Content Map Forward Tilt Adjustment 4 Light Handles/ Barriers 7 Power Button* 2 Touchpad Control 3 Light Shield/ Barriers 7 * Also operates light intensity on lights without touchpad functionality. Operate / Adjust... 2 Clean / Maintain... 6 Specifications and Warranty... 9 86.0670.00 Rev B 1

A-dec 300 LED Dental Light Instructions for Use Operate / Adjust Operate / Adjust Basic Operation How you operate the A-dec 300 LED dental light depends on how your dental light is configured. Dental Lights without Touchpad Functionality To turn on the light and change light intensity, use the power button on the dental light. If the light does not turn on, verify that the delivery system and/or chair power is on. Power Button Dental Lights with Touchpad Functionality To turn on the light, use the touchpad or the power button on the dental light. To change light intensity, use the touchpad. For more information about touchpad operation, see Touchpad Control on page 3. A-dec Touchpad Indicator Light Dental Light Button NOTE If you have a dental light without touchpad functionality, and you inadvertently press the dental light button, the indicator light will turn on. To turn off the indicator light, press and hold the dental light button. For additional questions about your specific equipment configuration, contact your local authorized A-dec dealer. 2

Touchpad Control Standard Touchpad Indicator Light Dental Light Button Dental Light Button ( ) For dental lights with touchpad functionality: Press to turn on the light. The light always turns on in the high intensity mode. If the light does not turn on, verify that the delivery system and/or chair power is on. Press again to switch to the composite/low mode. The indicator light on the touchpad flashes continuously when the light is in the composite/low mode. Press and hold to turn off the light. Dental Light Auto On/Off Feature The auto on/off feature turns on the light automatically when the chair back reaches a preset treatment position. The light turns off when you press or. If you press again, the chair returns to its previous position, and the light will turn back on. The light always turns on in high-intensity mode. To disable the auto on/off feature, press and hold or and at the same time for three seconds. One beep indicates that the auto on/off function is off. To re-enable, repeat this step. Three beeps indicate that the auto on/off feature is activated. Entry/Exit Treatment 1 Deluxe Touchpads Program Button X-Ray/Rinse Treatment 2 WARNING Ensure that the patient is positioned safely before using the chair preset functions. Always take extra care with small children and patients with limited mobility. Never leave the patient unattended while the chair is in motion. To stop the chair at any point, push any chair positioning button on the footswitch or touchpad. Note: Touchpad symbols are proprietary to A-dec Inc. 86.0670.00 Rev B 3

A-dec 300 LED Dental Light Instructions for Use Operate / Adjust Lighting Composite/Low Mode The composite/low mode reduces light intensity and premature curing of photo-initiated composites, sealants, and adhesives. Focal Range The dental light features a fixed focal range that provides optimum illumination between 16 30 inches (400 mm 750 mm) from the oral cavity. Range of Motion Three axes of rotation provide a wide range of motion. Use this capability to position the light for a clear view of tooth surfaces and minimal interference with other equipment and the dental team. Forward Tilt Adjustment If the light head does not hold its tilt position, or is difficult to tilt, adjust the forward tilt tension screw with a 7/64" hex key. Turn the screw clockwise to increase tension or counterclockwise to decrease tension. NOTE Other tension adjustments require disassembly. Please contact your authorized A-dec dealer if the light requires additional adjustments. 4

10 AM P 10 AM P 10 AM P 10 AM P 10 AM P NC Circuit Breaker Location Under abnormal conditions, the circuit breaker interrupts the flow of electricity. If the circuit breaker trips, reset it by pushing the circuit breaker button on the power supply. The power supply is typically located in the utilities area of your dental chair (see the table below for the circuit breaker location). Chair Model Power Supply Location Circuit Breaker Button Location A-dec 511 chair Chair motor pump area MAINS OUTPUT SIDE DENTAL POWER 4A MAX SUPPORT ARM LIGHT CB 3 CB 4 CB 5 OUTPUT 8A MAX 0V~ 24V~ 13A @ 2 VACUUM RELAY DATA CB4 A-dec 311 and A-dec 411 chair Chair motor pump area CB5 A-dec 200, Cascade, Decade, Performer, and early model A-dec chairs Utility floor box CB1 86.0670.00 Rev B 5

A-dec 300 LED Dental Light Instructions for Use Clean / Maintain Clean / Maintain Barrier Protection A-dec recommends barrier protection for all applicable touch and transfer surfaces. Touch surfaces are areas that come into contact with hands and become potential cross-contamination points during dental procedures. Transfer surfaces are areas that come into contact with instruments and other inanimate objects. In the USA, barriers must be produced under the Current Good Manufacturing Practice (CGMP) as specified by the U.S. Food and Drug Administration (USFDA). For regions outside the USA, refer to the medical device regulations specific to your location. NOTE For proper use and disposal of barriers, see the instructions provided by the barrier manufacturer. IMPORTANT For recommendations on cleaning and chemical disinfection of touch and transfer surfaces (where barrier protection is not applicable or when barriers are compromised), please see the A-dec Equipment Asepsis Guide (p/n 85.0696.00). 6

Dental Light Barriers Shield Light Handles Use barriers on the light handles to prevent cross contamination. The handles are shaped to easily accept the same disposable plastic sleeves designed for the air/water syringe. Light Handle with Barrier Multi-Lens Assembly Light Shield Barriers help protect and keep the dental light shield clean during procedures. Use only optically-correct barrier film that does not alter the light quality. A-dec recommends the SafeShield disposable barrier by Medicom (see page 8 for ordering information). If you do not use a barrier, carefully clean the light shield in place using a soft cotton cloth with non-abrasive soap and water. CAUTION Do not remove the shield unless absolutely necessary. The shield is fitted with a gasket to prevent dust and debris from entering the lens assembly. If liquid or dirt should bypass the gasket, the shield can be removed for cleaning. Use a flat-blade tool that won t damage the light housing. After removing the shield, do not touch or attempt to clean the multi-lens assembly or you may damage the components. Power Button Use one piece of barrier film to cover the power button. 86.0670.00 Rev B 7

A-dec 300 LED Dental Light Instructions for Use Clean / Maintain Dental Light Maintenance Items Description Medicom SafeShield Disposable Barrier (package of 10) Part Number 9565 Contact your authorized A-dec dealer to order these dental light maintenance items. LED Lens Shield and Gasket 90.1343.00 8

A-dec 300 LED Dental Light Instructions for Use Specifications / Warranty Specifications Warranty Warranty information is provided in the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. Power and Light Specifications Power: 15 watts maximum Focal Range: 16" 30" (400 mm 750 mm) LED Type: white HB-LED, 94 CRI Color Temperature: white 5000 Kelvin Light Pattern: 3.8" H x 5.7" W at 27.6" (95 mm H x 145 mm W at 700 mm) Nominal Light Intensity: high: 25,000 lux (2323 fc) composite*/low: 8,000 lux (743 fc) Heat Output: 51 BTU / hour * Composite mode is an industry accepted term and is not intended to meet the ISO 9680:2014, 5.2.10 standard. IMPORTANT For additional specifications, identification of symbols, and other regulatory requirements, see the Regulatory Information, Specifications, and Warranty document (p/n 86.0221.00), which is available in the Document Library at www.a-dec.com. NOTE Specifications are subject to change without notice. Requirements may vary depending on your location. For more information, contact your authorized A-dec dealer. 86.0670.00 Rev B 9

A-dec Headquarters 2601 Crestview Drive Newberg, Oregon 97132 United States Tel: 1.800.547.1883 within USA/CAN Tel: +1.503.538.7478 outside USA/CAN Fax: 1.503.538.0276 www.a-dec.com A-dec Australia Unit 8 5-9 Ricketty Street Mascot, NSW 2020 Australia Tel: 1.800.225.010 within AUS Tel: +61.(0).2.8332.4000 outside AUS A-dec China A-dec (Hangzhou) Dental Equipment Co., Ltd. 528 Shunfeng Road Qianjiang Economic Development Zone Hangzhou 311106, Zhejiang, China Tel: 400.600.5434 within China Tel: +86.571.89026088 outside China A-dec United Kingdom EU Authorized Representative Austin House, 11 Liberty Way Nuneaton, Warwickshire CV11 6RZ England Tel: 0800.ADEC.UK (2332.85) within UK Tel: +44.(0).24.7635.0901 outside UK ÍvÈ.Ç&fÈ.00:Î 86.0670.00 Rev B Copyright 2018 A-dec Inc. All rights reserved. IFUcov3