Oxymax W COS31. Brief Operating Instructions. Dissolved oxygen sensor

Similar documents
Operating Instructions Flexdip CYA112

Operating Instructions. Compressed air cleaning unit VAC BA00498C/07/EN/

Operating Instructions. Flowfit W CPA250. Flow assembly for ph/orp sensors. BA041C/07/en/

Operating Instructions CYR52

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Cleanfit CPA471. Technical Information. Compact retractable assembly for installation of ph, ORP electrodes in tanks or pipelines

Proline Prosonic Flow 93T Portable

Indumax P CLS50. Technical Information. Highly resistant, inductive conductivity sensor for standard, hazardous and high-temperature applications

Flowfit CPA250. Technical Information. Flow assembly for ph and ORP sensors

Proline Prosonic Flow 91W

Unifit CPA442. Technical Information. Process assembly For installation of 120 mm sensors in food and beverage, biotechnology and chemical industries

Technical Information Cleanfit CPA472D

Operating Instructions Dipfit CPA111

Orbisint CPS12/CPS12D/CPS13

Flowfit CYA251. Technical Information. Flow assembly for nitrate/sac, turbidity and oxygen sensors

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Ceraliquid CPS42/CPS42D/CPS43

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Conductivity Measuring Cells ConduMax W CLS 19

JUMO ecoline O-DO. Optical Sensor for Dissolved Oxygen. B Operating Manual /

Air terminal devices

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Orbisint CPS11 and CPS11D

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Orbipore CPS91 and CPS91D

Operating Instructions

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

Cleanfit P CPA472D. Technical Information. Retractable process assembly for ph, ORP and other industry sensors Heavy-duty version

Assembly and Maintenance Manual Type RSBW

Assembly instructions

Operating Instructions

Operating Instructions

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

ECTOS Deliverable 4. European Commission. Fifth Framework For Research And Development

original operating manual Operating manual Translation of the Item-No.: ,

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Explosion protected terminal boxes type, GHG 72.

DIAPHRAGM LIQUID PUMP NF 2.35

Operating Instructions

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating Instructions for Elevator Buffers type LP

Orbisint CPS11 and CPS11D

USER INSTRUCTIONS. Kämmer SmallFlow - Series / Low and Micro Flow Valves. Installation Operation Maintenance. Experience In Motion

Conductivity Sensors ConduMax W CLS 19

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Assembly and Maintenance Manual Type ASNU

Linear Luminaire for Fluorescent Lamps

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

Operator Instructions for Tension Links

USER INSTRUCTIONS. Kämmer SmallFlow / / SP Low and Micro Flow Valves. Installation Operation Maintenance

Technical Information Cleanfit CPA871

Manual Electronic Identification Systems BIS Read/Write Heads C3-slk_716464_E_1110.p65 Deutsch bitte wenden!

Conductivity Measurement CLM 280

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

Temperature Sensor without thread

Stamolys CA71AM. Technical Information

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

OPERATING INSTRUCTIONS

TIDALFLUX 2300 F Quick Start

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

General Specifications

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

DIAPHRAGM LIQUID PUMP NF 1.25

Read and understand this manual for safely usage.

General Specifications

Assembly and Maintenance Manual Type AS

Mounting and Operating Instructions EB 5863 EN. Electric Control Valves. Pneumatic Control Valve

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

OPERATING INSTRUCTIONS. Operating Instructions

Technical Information Ceraliquid CPS41D and CPS41

onlinecomponents.com

X JET (Counter current system) Instruction Manual

Pressure chlorine changeover unit C 7520

Operating Instructions for Roll-Up Door Operators / MDF

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Operating Instructions. TM Girder Clamps

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Breezair TBA 550 Installation Manual

Elektric actuator MC50/24-C

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Differential Pressure and Flow meters Accessories for the Media Series

Technical Information

DIAPHRAGM LIQUID PUMP NF 1.30

Gavita HortiStar 1000 DE EU/US

Ceraliquid CPS41 and CPS41D

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation manual wall-mounted distributor

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

OEM pressure transmitter with thin-film technology For mobile hydraulics Model MH-2

Series 3730 Electropneumatic Positioner Type

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Mounting and Operating Instructions EB 8097 EN. Pneumatic Control Valves Type and Type

OD 8382 OPTICAL DISSOLVED OXYGEN AUTOCLEAN

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Transcription:

Brief Operating Instructions Oxymax W COS Dissolved oxygen sensor These instructions are Brief Operating Instructions. For detailed information, please read the Operating Instructions and the special instructions on the supplied CD-ROM. The complete device documentation comprises: these Brief Operating Instructions the Operating Instructions on the supplied CD-ROM if necessary, certificates and calibration protocols (acc. to the version). KA85C/07/en/06.05 70006

Table of contents Oxymax W COS Table of contents Safety instructions.................................................. Designated use........................................................................... Installation, commissioning and operation....................................................... Operational safety........................................................................ Installation....................................................... Installation conditions...................................................................... Installation instructions..................................................................... Installation examples..................................................................... 5. Post installation check.................................................................... 9 Wiring......................................................... 9. Direct connection to the transmitter.......................................................... 9. Connection via junction box............................................................... 0 Commissioning................................................... Function check.......................................................................... Polarization............................................................................ Calibration............................................................................ Safety instructions. Designated use The oxygen sensor is suitable for continuous measurement of dissolved oxygen in water. Typical applications are: Measuring, monitoring and regulating the oxygen content in activated sludge basins. Monitoring the oxygen content in the sewage treatment plant outlet. Monitoring, measuring and regulating the oxygen content in public waters and fish farming water. Monitoring of oxygen enrichment in drinking water. Any other use than the one described here compromises the safety of persons and the entire measuring system and is, therefore, not permitted. The manufacturer is not liable for damage caused by improper or non-designated use.. Installation, commissioning and operation The device/measuring system may only be installed, connected, operated and maintained by trained technical personnel (e.g. certified electrician). The technical personnel must strictly adhere to the Operating Instructions, prevailing standards, legal regulations and certificates (depending on application). If the Brief Operating Instructions do not provide sufficient information, you must read the Operating Instructions. There, you can find detailed information on the device. Endress+Hauser

Oxymax W COS Installation The operator may only perform modifications and repairs of the device/measuring system that are explicitly permitted in the Operating Instructions. Do not operate damaged products and secure them against unintentional commissioning. Mark the damaged product as being defective. If faults can not be rectified, the products must be taken out of service and secured against unintentional commissioning.. Operational safety The sensor has been designed and tested according to the state of the art and left the factory in perfect functioning order. Relevant regulations and European standards have been met. As the user, you are responsible for complying with the following safety conditions: Installation instructions Local prevailing standards and regulations. " Caution! Pay attention to the technical data on the name plate! Installation. Installation conditions.. Orientation A Fig. : Angle of installation A Recommended angle of installation: 0... 80 a000087 Other angles are not permitted. Do not install the sensor overhead. Endress+Hauser

Installation Oxymax W COS.. Mounting location Select the installation location so that there is easy access for later calibration. Make sure that upright posts and assemblies are secured safely and vibration-free. For immersed operation in an activated sludge basin, select an installation location which produces a typical oxygen concentration.. Installation instructions.. Installing a measuring point! Note! For immersed operation, install the individual modules away from the basin on a solid base. Only carry out the final installation at the intended installation location. For a complete installation of a measuring point, proceed as follows:. Install a retractable or a flow assembly (if used) into the process.. Connect the water supply to the rinse connections (if you use an assembly with cleaning function).. Install and connect the oxygen sensor.. Install an immersion or an suspension assembly (if used) into the process. " Caution! For immersed operation, the sensor must be installed in an immersion assembly (e.g. CYA6). Do not install the sensor suspended from the cable. Screw the sensor into the assembly so that the cable is not twisted. Avoid exerting excessive tensile force on the cable (e.g. from jerky pulling). Select the installation location so that there is easy access for later calibration. # Warning! When using metallic assemblies and installation equipment, comply with national grounding regulations. Endress+Hauser

Oxymax W COS Installation. Installation examples.. Immersion operation Universal assembly holder and chain assembly a0000-en Fig. : CYH0 with immersible pendulum assembly Weather protection cover Upright post, square pipe SS AISI 0 Transverse pipe SS AISI 0 Star handle 5 Second fixing possibility for transverse pipe 6 Immersion assembly CYA 6 Fig. : Immersion assembly CYA 6 Protection cap Worm drive hose clip Pipe clips (detailed drawing in right half) PVC pipe 5 Threaded coupling a0000-en Endress+Hauser 5

Installation Oxymax W COS Universal assembly holder and fixed immersion assembly Fig. : Universal suspension assembly holder CYH0 with immersion assembly CYY05 Star handle Pipe holder Fixing bracket Immersion assembly (= immersion tube) a00005-en 6 Endress+Hauser

Oxymax W COS Installation Basin rim mounting with immersion tube 5 5 Fig. 5: Horizontal basin rim mounting Protection cover for cable entry Assembly holder Immersion assembly SS.0 (AISI 0) a00006 Fig. 6: Vertical basin rim mounting Basin rim mounting 5 Star handle a00007 Floating body mm/inch 800/.50 500/9.69 0/8.66 G Ø00/7.87 5 5 6 7 Cable route with strain relief and rain protection Mounting ring for ropes and chains with locking screw Lugs Ø5, x 0 for anchoring Saltwater-resistant plastic float Pipe 0x, stainless steel.57 (AISI 6Ti) Shock absorber and weight Oxygen sensor 6 7 Fig. 7: Floating body a00008-en Endress+Hauser 7

Installation Oxymax W COS.. Flow assembly 8 7 6 5 a000-en Fig. 8: Flow assembly COA50-B Screw-in part for sensor Screw ring Meter body Connection thread G¾ 5 Dummy plug (connection for spray head COR) Fig. 9: Bypass installation Main line Medium return Oxygen sensor, 7 Manually actuated or solenoid valves 5 Flow assembly COA50-B 6 90 pipe bracket 8 Medium removal a000.. Retractable assembly Detail A, (top view) Detail A, rotated 90 (side view) 5 Fig. 0: Permissible and impermissible sensor installation positions with retractable assembly COA5 Ascending pipe, best position Horizontal pipe, sensor top down, impermissible due to air cushion or foam bubble forming Horizontal pipe, installation with permissible installation angle (acc. to sensor version) Overhead installation, critical due to possible sediment buildup on fluorescence cap 5 Down pipe, impermissible a0007-en 8 Endress+Hauser

Oxymax W COS Wiring. Post installation check Check the membrane for leak tightness und replace it if necessary. Sensor and cable undamaged? Compliance with permissible sensor installation position? Is the sensor installed in an assembly and is not suspended from the cable? Avoid moisture by rain by fitting the protective cap to the immersion assembly? Wiring # Warning! The electrical connection must only be carried out by a certified electrician. Technical personnel must have read and understood the instructions in this manual and must adhere to them. Ensure that there is no voltage at the power cable before beginning the connection work.. Direct connection to the transmitter.. Field installation Connect the sensor directly to the transmitter (COM5-WX/WS) by using the special measuring cable with SXP plug ( å ). Fig. : SXP plug a0008.. Panel mounting Remove the SXP connector (transmitter side!) from the cable. Refer to the following table for the cable assignment and the assigned terminals for Liquisys M COM-WX/WS. Please note that the cable assignment changes depending on the sensor version (fixed cable or TOP68 connection). Endress+Hauser 9

Wiring Oxymax W COS Terminal COM Sensor with fixed cable (OMK) Sensor with TOP68 connection (CYK7) Core Assignment Core Assignment 87 YE +U B YE +U B 0 GY 0 V WH 0 V 96 PK NTC (analog) or Com. (digital) GN Communication (digital) 97 BU NTC (analog) or Com. (digital) BN Communication (digital) 88 BN U B Koax innen U B 9 GN Alarm 8 WH Sensor signal. Connection via junction box To lengthen the sensor connection beyond the length of the fixed cable, you require a junction box VS ( å, å ). 8 /. 80 /.5 YE GY PK BU BN GN WH 87 0 96 97 88 9 8 mm / inch Fig. : Junction box VS to a field device SXP plug to field device SXP plug from sensor a0009-en Fig. : Junction box VS to a panel mounted device SXP plug from sensor Measuring cable (OMK) to the transmitter Connection department of the transmitter a0000 0 Endress+Hauser

Oxymax W COS Commissioning Commissioning. Function check Before first commissioning, check if: the sensor is correctly installed the electrical connection is correct. If using an assembly with automatic cleaning, check the correct water connection at the assembly rinse connection. # Warning! Danger of medium leaking off Before applying compressed air to an assembly with cleaning facility, make sure the connections are correctly fitted. Otherwise, the assembly may not be insert into the process.. Polarization The sensor was tested in the factory for perfect functionality and is supplied ready for operation. To prepare for calibration, proceed as follows:. Remove the sensor protective cap.. Place the externally dry sensor in atmospheric air. The air should be saturated with water vapour. Therefore, install the sensor as close to the water surface as possible. When calibrating the sensor membrane, make sure the membrane remains dry. Therefore, avoid any direct contact with the water surface.. Connect the sensor to the transmitter and switch on the transmitter.. Switch-on the transmitter. If you connect the sensor to the transmitter Liquisys M COM/5, polarisation is automatically performed after switching on the transmitter. 5. The polarisation time takes about hour.! Note! Polarisation starts high, then drops gradually. You will recognise the end of polarisation when the display stabilises and remains practically constant. " Caution! When you remove the sensor from the medium, protect the sensor from strong sunlight. Make sure you comply with the instructions for commissioning and calibration in the Operating Instructions of the transmitter. Endress+Hauser

. Calibration Calibrate the sensor (calibration type "Air") immediately after it s polarization.. Remove the sensor from the medium.. Clean the outside of the sensor with a damp cloth. Then dry the sensor membrane e.g. by using a tissue.. If the sensor is removed from a closed pressure system with a process pressure greater than atmospheric pressure: Open the membrane cap to equilibrate the pressure and clean the cap if necessary. Replace the electrolyte filling and close the membrane cap again. Wait for the polarisation time to end.. Then wait while the sensor adjusts to the temperature of the ambient air. This takes about 0 minutes. Check that the sensor is not in direct sunlight during this time. 5. If the measured value display on the transmitter is stable, carry out the calibration in accordance with the Operating Instructions of the transmitter. 6. Place the sensor in the medium again.! Note! Make sure you comply with the instructions for calibration in the Operating Instructions of the transmitter. www.endress.com/worldwide KA85C/07/en/06.05 Printed in Germany / FM+SGML 6.0 / DT 70006