Outlets and Accessories

Similar documents
Service Manual Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Slim Style Compatible

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Compatible

RETRACTABLE CEILING COLUMN

Medical Gas Outlet Adaptor, Fitting and Hose Catalog

SERVICE MANUAL. DiamondCare Recessed Wall Outlet and Electrical. MAN Rev. B

Audi-Larm TM Audible Alarm: AirHawk II Air Mask

Technical Datasheet. SP Terminal Units. Classification. Services. Terminal Block. Check Valve Assembly. Tailpipe Options

2 CYLINDER MOBILE CART ASSEMBLY INSTRUCTIONS

Lifeline Medical Systems

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

Valtek Spring Cylinder Linear Actuators

Cylinder and Valve: AirHawk II Air Mask

Automatic Changeover Medical Manifold Installation, Operation and Maintenance Manual

Lifeline Medical Systems

TECHNICAL DATA 1-1/2 (dn40)

FkcoqpfEctg Eqpuqng Qwvngv

Escape Cylinder and Valve

2013 IMPCO Technologies, Inc. Page 1 of 20 EPR Repair Kit Instructions (PPI-122, Rev-B)

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Vacuum Regulators and Accessories

Second Stage Regulator - 1/4 Turn

INSTRUCTION AND MAINTENANCE MANUAL FR95 PRESSURE REGULATOR

INSTALLATION INSTRUCTIONS

and 1/4 TURN SECOND STAGE REGULATOR TAL 502 (L) Rev. 0 MSA 2005 Prnt. Spec (I) Mat Doc

1.1 Quad Valve and Tri-Valve. Contents WATER DUMP BODY O-RING EXHAUST VALVE QUAD VALVE TIE WRAP EXHAUST MAIN BODY O-RING

Axis MEDICAL GAS TERMINAL UNITS

REGULATORS ALPHA 8 SECOND STAGE OCEANIC ALPHA 8 SERVICE PROCEDURE

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

LEAK TEST PROCEDURE APPLICABLE TO DC3 INTELLI-GRIP LIFTERS MODELS MRT4-DC3, MRTA8-DC3, MRTALP8-DC3 AND PC/P1-DC3 SERIES

DeZURIK SPRING RETURN CYLINDER OPERATOR FOR G-SERIES ACTUATORS USED ON PEF 100% PORT ECCENTRIC VALVES

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Rosemount 402 and 402VP

MEDICAL IRRIGATION K PUMP OPERATING MANUAL: Manufactured for: K.M.I 3185 Palisades Dr Corona CA USA Model No.

DESCRIPTION & OPERATION

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

B21 Series BASOTROL Gas Valve

Copyright 1999 National Glass Association v.4.0

CYLINDER VALVES. Assembly & Maintenance Guide

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Instructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)

Series 111 Accumulator Product Information

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Nuvo Surgical Navigator Equipment Management System USER, INSTALLATION, & MAINTENANCE MANUAL

VANGUARD A EZ INSTALL OPERATOR S MANUAL

Service Manual Air Plus Second Stage

Operating & Maintenance Manual. Automatic Medical Gas Manifold Digital Dome Loaded Regulator NFPA v1.5

Welker Automatic Insertion Diffusing Probe Model AIP-3DP

Asepsis 21 Delivery Unit

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

2200 North Main Street Washington, PA PH: FX:

TECHNICAL DATA. Q= C v P S

Firehawk Second Stage Regulator Fire Service

OPERATION AND MAINTENANCE INSTRUCTION MANUAL. AEU-17B & AEU-17BV2 Implant / Surgery Systems

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

250L Cartridge Dual Seal

GE CARESCAPE Monitor B650 on VHM- PL Variable Height Arm Channel Mount with Vertical Position Lock

Automatic Medical Gas Manifold Dome Loaded Regulator NFPA v1.1

Installation Instructions

Back Pressure Regulator

BLACKMER BYPASS VALVES

Welker Heated Instrument Regulator

Service Manual Air Tech Second Stage

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

T60 REGULATOR REPAIR KIT INSTRUCTIONS

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER AUTOMATIC INSERTION PROBE

ISSUER: WRC 10/29/10 ENGINEERING: PROD/MTL: QA APPROVAL: REVISION HISTORY

Racing Jack Max. Capacity: 3,000 lbs. (1,361 kg)

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

Introduction. Installation. Maintenance. Bill of Materials

Fisher 657 Diaphragm Actuator Sizes and 87

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

Operating instructions Form no safety definitions

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

SD Bendix E-10PR Retarder Control Brake Valve DESCRIPTION. OPERATION - Refer to Figure 2

REGULATORS DELTA 3 SECOND STAGE TROUBLE SHOOTING SYMPTOM POSSIBLE CAUSE TREATMENT

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER PROBE MOUNTED LIQUID ELIMINATOR

Rev C /08

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Adjustable Differential Relay A1

Installation, Operation, and Maintenance Manual

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Differential Pressure Transmitter

DeZURIK LA-SERIES MANUAL & ELECTRIC ACTUATORS

ENGINE AND EMISSION CONTROL

HIGH PRESS. - HIGH TEMP. (HPHT) FILTER PRESS 4 - UNIT ASSEMBLY 175 ml Capacity - OFI No

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

Pressure Switch with Gauge for Pressure

PRECISION UK Ltd. Medical Gas Outlet BS Standard

SPIN BLAST TOOL O.M

Fisher RSS Lined Globe Valve

Temperature Sensor Series

ACTIVAL Two-way Ball Valve with Threaded-end Connection

Fisher RSS Lined Globe Valve

Troubleshooting the Transmission Hydraulic System

ESCORT LC Pump. Instruction Manual WARNING

Transcription:

Service Manual Series B Quick-Connect and Diameter-Index Safety System Outlets and Accessories MAN0-03 Part No. 803-00 Rev. D Pg.

Table of Contents General Product Description...3 Tools and Service Materials... Cleaning and Lubrication... Inspection and Testing... Service...-9 Definition of Statements Statements in this manual preceded by the following words are of special significance. WARNING: Means there is a possibility of injury or death to yourself or others. CAUTION: Means there is a possibility of damage to the unit or other property. NOTE: Indicates points of particular interest for more efficient and convenient operation. Troubleshooting Guide...0 Replacement Components...-9 Introduction This manual provides the information needed to service Beacon Medical Products Series B Medical Gas Wall Outlets. The information contained in this manual is intended for use by technicians or personnel qualified to repair and service medical equipment. Part No. 803-00 Rev. D

General Product Description Beacon Medical Products medical gas and vacuum quick-connect outlets provide a means of connecting to the medical gas piping system. When the appropriate adapter is inserted in the outlet, the primary valve is opened, permitting gas to flow. A mechanical latch secures the adapter in the outlet. The primary seal closes when the adapter is removed. Outlets are typically for oxygen, nitrous oxide, air, or vacuum and have been cleaned for the indicated service. Threaded outlets are typically used in ceilings of operating rooms or in place of quick-connect outlets. Connection to the outlet is by means of a nut and nipple. Gas-specific indexing to prevent accidental connection to the wrong service is accomplished by a series of interference diameters in accordance with the Diameter-Index Safety System (DISS) published by the Compressed Gas Association (CGA) in Standard V-5. The nipple opens the primary valve as the nut is tightened to secure the nipple in the outlet. The primary valve closes when the nipple is removed. WARNING: Do not use oil on adapters or outlets. Outlet Outlet Release DISS Nut Adapter Part No. 803-00 Rev. D 3

Tools and Service Materials Description Silicone lubricant, Dow Corning compound # Truarc Pliers.038 No. Phillips screwdriver Manufacturer Local source Local source Local source No. Flat blade screwdriver Local source Oxygen compatible leak detector solution Cleaning and Lubrication Sherlock or equivalent Beacon Medical Products outlets are cleaned for oxygen or the indicated service. Exposed surfaces of outlets may be cleaned with a mild detergent solution or wiped with a disinfectant used for patient room surfaces that is compatible with acetal and nylon plastic, anodized aluminum, and die cast zinc. Lubricate elastomer seals sparingly with a lubricant compatible with oxygen. Refer to Tools and Service Materials. DO NOT USE OIL. Inspection and Testing Medical gas outlets in high use areas should be inspected at least every six months and more frequently if outlets are used daily. All outlets should be inspected at least once a year. Follow National Fire Protection Association Standard 99, 99C Gas and Vacuum Systems, and Canadian Standards Association, Standard Z 305. Nonflammable Medical Gas Piping Systems requirements and methods for periodic testing and maintenance of medical gas and vacuum systems. Service Notify appropriate hospital personnel when performing service or maintenance to medical gas systems. Consult the Troubleshooting Guide to determine the required repair. Outlets incorporate a primary and secondary valve. The secondary valve prevents system gas from escaping when the primary valve is removed for service. The primary valve is contained in the quick-connect and DISS valve assemblies and the secondary valve is contained in the outlet block assembly which is brazed to the pipeline. Refer to Replacement Components for identification of replacement part numbers. Quick-Connect and DISS Valve Assemblies (Primary Valve) Quick-connect and DISS valves may be removed for replacement of seals and some components without interrupting service to other outlets in the piping system. If vacuum quick-connect or DISS valves are to be removed for a prolonged period of time, install a secondary seal plug (P/N -8383- PG) in the outlet block opening. To check a latch or DISS valve for leaks, apply leak detector solution at the primary valve opening both with and without the adapter connected. Bubbles indicate pressure leaks. Some leaks may be audible. The following instructions are for servicing a leaking latch or DISS valve. NOTE: Replace elastomer seals whenever outlets are disassembled. Part No. 803-00 Rev. D

Puritan-Bennett Quick-Connect Valve. Back off the two mounting screws () until the latch valve () can be pulled from the outlet. As the screws are loosened, system pressure will push the latch valve from the outlet.. Remove the retaining ring (3) from the back of the valve assembly () by removing the two screws (). 3. Remove the connector (5) from the valve assembly ().. Remove the spring and poppet () and primary seal (). Obtain a new primary seal (). Inspect other items for wear or damage, and replace with new parts as necessary. 5. Reassemble the quick-connect valve.. Reinstall the latch valve in the outlet block. Coat the connector (5) with a thin film of silicone lubricant to aid in insertion. Use care not to overtighten mounting screws () as this can cause distortion of the latch valve.. Insert a gas-specific adapter in the latch valve. It should enter smoothly, latch, flow gas, and remain in place. If not, replace the entire latchvalve assembly (). 3 5 Puritan-Bennett Quick-Connect Valve Part No. 803-00 Rev. D 5

Chemetron-Type Quick-Connect Valve. Back off the three mounting screws () until the latch valve () can be pulled from the outlet. Remove the two bottom screws first. As screws are loosened system pressure will push the latch valve from the outlet.. Remove the four screws (3) holding the back plate () in place. 3. Remove the connector () from the valve assembly.. Remove the washer () and secondary seal (5) from the front of the connector (). Obtain a new secondary seal (5). 5. Remove the retaining ring () from the back of the connector () using Truarc pliers to compress the retaining ring. Remove the spring and poppet (0), primary seal (9), dust seal spring (8), and dust seal (). Obtain a new primary seal (9). Inspect other items for wear or damage, and replace with new parts as necessary.. Reassemble the latch valve.. Reinstall the latch valve () in the outlet block. Coat the connector () with a thin film of silicone lubricant to aid in insertion. Use care not to overtighten mounting screws () which can cause distortion of the latch valve. 8. Insert a gas-specific adapter in the latch valve. It should enter smoothly, latch, flow gas, and remain in place. If not, replace the entire latchvalve assembly (). 3 9 0 3 5 8 Chemetron-Type Quick-Connect Valve Part No. 803-00 Rev. D

Medaes-Type Quick-Connect Valve. Back off the two mounting screws () until the latch valve () can be pulled from the outlet. As the screws are loosened, system pressure will push the latch valve from the outlet.. Remove the four screws () holding the back plate (3) on the latch valve (). 3. Remove the connector (). Remove the washer (5) and secondary seal () from the connector. Remove the spring () from the valve assembly. Obtain a new secondary seal ().. Remove the retaining ring () from the back of the connector () using Truarc pliers to compress the retaining ring. Remove the spring and poppet (), primary seal (0), dust seal spring (9), and dust seal (8). Obtain a new primary seal (0). Inspect other items for wear or damage, and replace with new parts as necessary. 5. Reassembly the latch valve ().. Reinstall the latch valve () in the outlet block. Coat the connector () with a thin film of silicone lubricant to aid in insertion. Use care not to overtighten mounting screws () which can cause distortion of the latch valve().. Insert a gas-specific adapter in the latch valve. It should enter smoothly, latch, flow gas, and remain in place. If not, replace the entire latchvalve assembly (). 3 3 8 9 0 5 Medaes-Type Quick-Connect Valve Part No. 803-00 Rev. D

DISS Valve. Back off the two mounting screws () until the DISS valve () can be pulled from the outlet.. Remove the O-Ring seal (3) from the front of the valve body. Install a new O-Ring seal (3). O-Ring seal (3) is used on all DISS valves except for oxygen and WAGD. 3. Remove the retaining ring () from the back of the valve assembly () using Truarc pliers to compress the retaining ring. Remove the spring and poppet (5), primary seal (), and valve stem (). Obtain a new primary seal (). Inspect other items for wear or damage, and replace with new parts as necessary.. Reassemble the DISS valve (). 5. Reinstall the DISS valve () in the outlet block. Coat the connector with a thin film of silicone lubricant to aid in insertion. Use care not to overtighten mounting screws () as this can cause distortion of the DISS valve ().. Connect a gas-specific nut and nipple to the DISS valve. Connection should be smooth and hand tightening of the nut should be sufficient to allow gas flow without leakage. If not, replace the entire DISS valve assembly (). 5 3 Diameter-Index Safety System Valve 8 Part No. 803-00 Rev. D

Outlet Block Rough-In Assembly WARNING: Be certain to shut off supply pressure to the outlet before performing service. Inside the pressure gas outlet block is a secondary valve. The secondary valve s function is to shut off pressure gas flow when the primary valve is removed. The secondary valve contains a seal to prevent leaks around the primary valve connector. As the secondary valve seal is only a static seal, the need for replacement is infrequent. Apply leak detector solution over the white poppet and the outer edge of the seal at the block. Look for bubbles indicating leaks (pressure systems). Also check for leaks when the latch or DISS valve connector is partially inserted by flowing leak detection solution around the connector. Listen for leaks in vacuum systems when the seal plug (P/N -8388-00) is installed. Below are instructions for servicing a leaking secondary valve seal.. Turn off outlet supply pressure.. Bleed residual pressure from the outlet by depressing the secondary valve poppet (). 3. Remove the retaining ring () from the inside of the outlet valve block. Use a small screwdriver to carefully remove the ring as shown in the inset.. Remove the washer (3), seal (), secondary valve poppet (), and spring (5). Obtain a new seal (). Inspect other items for wear or damage, and replace with new parts as necessary. 5. Reassemble the secondary valve. 5 3 Secondary Valve Part No. 803-00 Rev. D 9

Troubleshooting Guide Symptom Possible Cause Corrective Action Quick-Connect or DISS Valve Leaks without quick-connect adapter in place. Faulty primary seal Faulty spring and poppet Replace Replace with quick-connect adapter in place. Faulty primary seal (PB only) Faulty secondary seal (Chemetron and Medaes-type only) Faulty quick-connect stem Replace Replace Replace without DISS nut and nipple in place with DISS nut and nipple in place. Faulty primary seal Faulty DISS nipple Faulty O-Ring seal Replace Replace Replace Adapter will not engage and/or release Damaged adapter Wrong adapter Damaged latch-valve assembly Replace adapter Check adapter/outlet gas indexing and labels Replace Flow Rate Does Not Meet Specification Piping system pressure/vacuum incorrectly set Restriction in piping system System demand greater than supply source or system capacity Reset Check system and/or outlet Check supply source and system sizing Outlet Pressure or Vacuum Does Not Meet Specification System pressure/vacuum not set correctly System demand exceeds supply source capability or system capacity Restriction in piping system or outlet Reset Check supply source and system sizing Check and remove 0 Part No. 803-00 Rev. D

Replacement Components Puritan-Bennett Quick-Connect Valve Assembly. Puritan-Bennett quickconnect valve assembly (includes items through 8) A and A not included A. Quick-connect valve assembly for upgrade to Series B (includes items through 5, A, A, and 8) Standard Upgrade -30930-00 -3830-00 Oxygen (U.S. labeling) -3093-00 -383-00 Nitrous oxide (U.S. and International labeling) -3093-00 -383-00 Air (U.S. labeling) -30933-00 -3833-00 Vacuum (U.S. labeling) -30935-00 -3835-00 Oxygen (International labeling) -3093-00 -383-00 Air (International labeling) -30938-00 -3838-00 Vacuum (International labeling) -30939-00 -3839-00 WAGD (U.S. labeling) 3. -85-PG Mounting screw (two required, pkg of 0) 3. -50-PG Retaining washer (two required, pkg of 0). -853-PG Screw (two required, pkg of 0) 5. -50-00 Connector retainer. -550-00 Connector A. -558-00 Connector (valve upgrade). Spring and poppet kit -3030-PG Vacuum (pkg of 0) -3008-PG Pressure (pkg of 0) A. Spring and poppet kit (valve upgrade) -90-PG Vacuum (pkg of 0) -908-PG Pressure (pkg of 0) 8. -90099-00 Seal (pkg of 5) 9. -35-00 Tim Plate (5" center spacing) 0. -350-00 Trim Plate (3 /" center spacing) 5 8 A A 9 0 Puritan-Bennett Quick-Connect Valve Assembly Part No. 803-00 Rev. D

Replacement Components Chemetron-Type Quick-Connect Valve Assembly. Chemetron-type quick-connect latch-valve assembly (includes items through 3) -30950-00 Oxygen (U.S. labeling) -3095-00 Nitrous oxide (U.S. and international labeling) -3095-00 Air (U.S. labeling) -30953-00 Vacuum (U.S. labeling) -30955-00 Oxygen (International labeling) -3095-00 Air (International labeling) -30958-00 Vacuum (International labeling). -85-PG Mounting screw (three required, pkg of 0) 3. -50-PG Retaining washer (pkg of 0). -85303-PG Screw (four required, pkg of 0) 5. -50-00 Back plate. -835505-PG Retaining ring (pkg of 0). Spring and poppet kit (includes item 8) -9058-PG Chemetron vacuum and evacuation (pkg of 0) -9059-PG Chemetron pressure only (pkg of 0) 8. -0-PG O-Ring (pkg of 0) 9. -83330-00 Dust seal spring 0. -5-00 Dust seal. -50-PG O-Ring (pkg of 0). -5038-00 Washer 3. -5530-00 Connector. -35-00 Trim Plate (5" center spacing) 5. -350-00 Trim Plate (3 /" center spacing) 5 3 3 0 9 8 5 Chemetron-Type Quick-Connect Valve Assembly Part No. 803-00 Rev. D

Replacement Components Medaes-Type Quick-Connect Valve Assembly. Medaes-type quick-connect latch-valve assembly (includes items through ) -3090-00 Oxygen (U.S. labeling) -309-00 Nitrous oxide (U.S. and international labeling) -309-00 Air (U.S. labeling) -3093-00 Vacuum (U.S. labeling) -3095-00 Oxygen (International labeling) -309-00 WAGD (U.S. labeling) -309-00 Air (International labeling) -3098-00 Vacuum (International labeling) -3099-00 Evacuation (U.S. labeling). -85-PG Mounting screw (two required, pkg of 0) 3. -50-PG Retaining washer (pkg of 0). -85303-PG Screw (four required, pkg of 0) 5. -50-00 Back plate. -835505-PG Retaining ring (pkg of 0). -9058-PG Spring and poppet kit (includes item 8) Medaes pressure, vacuum and evacuation (pkg of 0) 8. -0-PG O-Ring (pkg of 0) 9. -83330-00 Dust seal spring 0. --00 Dust seal. -50-PG O-Ring (pkg of 0). -5038-00 Washer 3. -833953-PG Spring (pkg of 0). -55-00 Connector 5. -35-00 Trim Plate (5" center spacing). -350-00 Trim Plate (3 /" center spacing) 5 8 3 0 9 5 3 Medaes-Type Quick-Connect Valve Assembly Part No. 803-00 Rev. D 3

Replacement Components DISS Valve Assembly. DISS valve assembly (includes items through 8) -3090-00 Oxygen (U.S. labeling) -309-00 Nitrous oxide (U.S. and international labeling) -309-00 Air (U.S. labeling) -3093-00 Vacuum (U.S. labeling) -309-00 Nitrogen (U.S. and international labeling) -3095-00 Oxygen (International labeling) -309-00 Air (International labeling) -3098-00 Vacuum (International labeling) -3099-00 WAGD (U.S. labeling) -3090-00 Carbon dioxide (U.S. and international labeling) -309-00 CO /O mixture (CO over.5%) -309-00 O /CO mixture (CO not over.5%) -3093-00 He/O mixture (He over 80.5%) -309-00 O /He mixture (He not over 80.5%) 3 8 5. -85-PG Mounting screw (two required, pkg of 0) 3. -50-PG Retaining washer (two required, pkg of 0). O-Ring (pkg of 0) -53-PG Air -03-PG Vacuum -50-PG Nitrogen -53-PG CO, CO /O mix, He/O mix -538-PG O /CO mix -539-PG Evacuation -508-PG O /He mix -0-PG N O 5. -835505-PG Retaining ring (pkg of 0). -9058-PG Spring and poppet kit DISS pressure, vacuum and evacuation (includes item, pkg of 0). -0-PG O-Ring (pkg of 0) 8. Valve stem -553-00 Oxygen -55-00 Other gases -555-00 Vacuum 9. -35-00 Trim Plate (5" center spacing) 0. -350-00 Trim Plate (3 /" center spacing) 9 0 DISS Valve Part No. 803-00 Rev. D

Replacement Components Slide Accessories. -85-PG Mounting screw " (pkg of 0). -55-00 Slide stop 3. -85-PG Mounting screw 3 /" (pkg of 0). -35008-00 Slide bracket 5. -59-00 Insert (blank). -35-00 Trim Plate (5" spacing) -350-00 Trim plate (3 /" spacing) not shown. -3500-00 Slide bracket 8. -58-00 Insert (blank) 5 3 8 3 Slide Accessories Part No. 803-00 Rev. D0 5

Replacement Components Outlet Block Rough-In Assemblies. Concealed rough-in assembly (includes items, through 0) A. Console rough-in assembly (includes items through 0) B. Console rough-in assembly w/ hose barb connector (includes items through 0) Console with Concealed Console Hose Barb -330-00 -3300-00 -330-00 Oxygen (U.S. labeling) -33-00 -330-00 -33-00 Nitrous oxide (U.S. and International labeling) -33-00 -330-00 -33-00 Air (U.S. labeling) -333-00 -3303-00 -333-00 Vacuum (U.S. labeling) - - -333-53 Vacuum (U.S. Labeling, 5/ hose barb) -33-00 -330-00 -33-00 Nitrogen (U.S. and International labeling) -335-00 -3305-00 -335-00 Oxygen (International labeling) -33-00 -330-00 -33-00 Air (International labeling) -33-00 -330-00 -33-00 Vacuum (International labeling) -339-00 -3309-00 -339-00 WAGD (U.S. labeling) - - -339-53 WAGD (U.S. labeling, 5/ hose barb) -330-00 -3300-00 -330-00 Carbon dioxide (U.S. and International labeling) -33-00 -330-00 -33-00 CO /O mixture (CO over.5%) -33-00 -330-00 -33-00 O /CO mixture (CO not over.5%) -333-00 -3303-00 -333-00 He/O mixture (He over 80.5%) -33-00 -330-00 -33-00 O /He mixture (He not over 80.5%). -85-PG Screw (two required, pkg of 0) 3. -8383-PG Plug (vacuum outlets only, pkg of 0). -835900-PG Retaining ring (pkg of 0) 5. -503-PG Washer (pkg of 0). -5508-PG Seal (pkg of 0). --PG Poppet (pkg of 0) 8. -833-PG Spring (pkg of 0) Part No. 803-00 Rev. D

B A 8 5 3 Outlet Block Rough-In Assemblies Part No. 803-00 Rev. D

Replacement Components Electrical Accessories. -0505-00 Wall mounting box. -050-00 Wall mounting plate 3. -85-PG Screw (two required, pkg of 0). -050-00 Plaster ring 5. -35-00 Trim Plate (5" spacing) -350-00 Trim Plate (3 /" spacing) not shown. -80-PG Mounting screw (two required, pkg of 0). -5-00 Insert (grounding outlet) 8. -850-00 Hampden grounding outlet 9. -5-00 Insert (single and Hubbellock receptacle) 0. -85-00 Hospital grade single receptacle. -85-00 Hubbellock receptacle, 5V, 0A. -858-PG Mounting screw (pkg of 0) 3. -5-00 Insert (duplex receptacle). Hospital grade duplex receptacle -855-00 5V, 0A, gray -855-00 5V, 5A, gray -853-00 5V, 0A, red -85-00 5V, 5A, red -8589-00 5V, 0A, ivory -8589-0 5V, 5A, ivory 5. -59-00 Insert (blank) 5 8 3 0 9 3 5 Electrical Accessories 8 Part No. 803-00 Rev. D

Replacement Components Electrical Ceiling Drop. -8598-00 Hospital grade receptacle, 5 V, 0A -8599-00 Hubbellock receptacle, 5V, 0A. -85-00 Screw ( required) 3. -5-00 Cover plate insert. -35-00 Trim Plate (5" spacing) 5. -808-00 Mounting screw (two required, pkg of 0). -85-00 Strain relief. -588-00 Mounting plate 8. -808-00 Locknut 8 5 3 Electrical Ceiling Drop Part No. 803-00 Rev. D 9

MAN0-03 Part No. 803-00 Rev. D Pg. 0 Hubbellock is a registered trademark of Hubbell Incorporated. 00 BeaconMedaes Products. All rights reserved. Corporate Headquarters: BeaconMedæs 800 Overview Drive Rock Hill, SC 930 Phone (803) 8-500 Fax (803) 8-550 For technical support or to place an order call: 888 MEDGAS (-888-3-3) Fax (803) 8-50 www.beaconmedaes.com