Canadian Manufacturer of Quality Weighing Systems

Similar documents
MODEL. TI-500 RF Series. User Manual. Digital Weight Indicator (with wireless weighing capability)

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

The RCS-6V kit. Page of Contents. 1. This Book 1.1. Warning & safety What can I do with the RCS-kit? Tips 3

Weighing Scale IDS-802. User Manual

Electronic Crane Scale

Adam Equipment WBW & WBW-M SERIES. (P.N , Revision A2, November 2011)

SMIDLEY MINI-SCALE RETROFIT INSTRUCTIONS

OVERVIEW OF CONTROLS

MGB V8 Roadster restoration project Report 97

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

SPC Series. Digital Scale. Operation Manual

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Service Manual. Model L500 and L600 Smart Lift. WARNING: Cancer and Reproductive Harm - Form #1-144 Rev.

KILOTECH. KWD 500 Water tight. Portion/Weighing Scale

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Setup Guide and Chassis Tuning Tips (simple version) By Jim Daniels

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Service Manual Model L1000 Smart Lift

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

INSTRUCTIONS FOR TRI-METRIC BATTERY MONITOR May 8, 1996

OCS Series. High Resolution Digital Crane Scale. User Guide

Service Manual Model S800 Smart Stand

Fairbanks Scales OPERATING MANUAL. HAZARDOUS ENVIRONMENT INDICATOR Model H D. BULLETIN SJ4572 / Issue #2

Mini Automotive Controller Installation & Operation Manual

Service Manual Model S400 and S500 Smart Stand

Electricity. Teacher/Parent Notes.

MASSLOAD TECHNOLOGIES

4.1 Flow Rate Verification and Adjustment

Adam Equipment CPW COMPACT SCALE

B-RAD Select USER MANUAL TABLE OF CONTENTS

Compact Scales. Software Revision V1.25 & above

Ford Gasoline Speedo-Pro Programmer. Reprogram. Power

EDGE. User Manual. EDGE-5K (5000g x 1g) Copyright 2012 American Weigh Scales, Inc. All rights reserved. Rev. 2.0

HOW TO MAKE YOUR OWN BATTERIES

SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...OPERATING INSTRUCTIONS.

1- Select the best mounting location

SW20 Coolant System Maintenance.

Trip 2, 2L, 3 and 5W Owner s Manual. ENGLISH

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE

Installation Instructions

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Manual KREBS Viscometer PCE-RVI 5

ECOWEIGH Series ECO-5K. User Manual. ECO-5K (5000g x 1g) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

MDI-20. User Manual. Baby Scale. MDI-20 (44lb x 0.1oz) Copyright 2011 American Weigh Scales, Inc. All rights reserved. Rev. 1.0

Using the Weigh Wagon

Basic Vehicle Control Skills Test

THUNDERBIRD. Agricultural Weighing Systems SS1000 Instructions

ECT Display Driver Installation for AP2 Module

Ford Racing BOSS 302 Engine Oil Cooler (11-14 GT)

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

4.2 Component Identification

OCS-T High Resolution Digital Crane Scale

1. Introduction Specifications Operation Guide Trouble shooting Note... 13

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Power. Reprogram. Ford Gasoline E-Z TUNE Programmer

Instructions for 2-row monitoring only

Computerscales DX Model Operating Instructions

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

AQA GCSE Physics. 55 minutes. 55 marks. Q1 to Q4 to be worked through with tutor. Q5 to Q7 to be worked through independently.

CHARGE TANK. Overview. Using The Charge Tank. User Guide

500Z Owner's Manual & Troubleshooting

Belt-Way Integrator Features

Renewable Energy Sprint

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

SC-Series. User Manual. American Weigh Scales. SC-501, SC-501A (500g x 0.01g) SC-2KG, SC-2KGA (2000g x 0.1g)

SSP-Series Portable Balances Operation Manual

CFM-20/40/100/200/300

IT'S MAGNETIC (1 Hour)

Model DS7060 Handrail Scale. User Manual

Save Thousands of Dollars Per Year!

Vehicle Security / Remote Start / Remote Access System Installation

PROVEX Installation Guide. Version 1.0

Holden VZ 3.6L ECU & Powertrain Interface Module Linking Instructions

Price Computing Scale D Series Operation Manual

INSTRUCTIONS SPECIAL FEATURES

Introduction: Problem statement

GWM GROSS WEIGH BAGGING SCALE

Super Brain 992 Palm Charger

Computerscales DX Model Operating Instructions (Also applies to models 72632, 72635, 72636)

Friction and Momentum

Vehicle Security / Remote Start / Remote Access System Installation

MODEL PS-4 DIGITAL PORTION SCALE

Cab Control App OPERATORS MANUAL

RR Concepts. The StationMaster can control DC trains or DCC equipped trains set to linear mode.

FL-100-R (109) Operations and Installation Manual

MDX-300 Series. For 12-volt automotive starting batteries and starting/charging systems INSTRUCTION MANUAL

Vehicle Security / Remote Start / Remote Access System Installation

Pass Your Driving Test - Mistakes to Avoid

Gobius 1, Level Switch for Water, Fuel and Fluid Tanks, new version 5.0. Installation Guide. Before you begin

I cannot believe it has been so long since my last update. A lot has happened and I will try to bring everyone up to speed. First of all, I had my

IMPORTANT! DO NOT THROW AWAY THE SHIPPING CARTON AND PACKING MATERIAL

DCC-2500 Digital Climate Control for Vintage Air GEN-IV systems

elabtronics Voltage Switch

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

Instructions for 2-row monitoring only

Search by illustration

#6 IN A SERIES SHARING THE ROAD. How to stay safe.

Experiment 3. The Direct Current Motor Part II OBJECTIVE. To locate the neutral brush position. To learn the basic motor wiring connections.

CONTENTS 1 V500 OWNER S MANUAL

Transcription:

Sept., 2005 Product Update Thank you for purchasing your load beam scale system from Massload Technologies. We genuinely hope that this system will provide years of trouble free operation in your application and to this end we also hope that this document will help to ensure that. As you may know there are numerous manufacturers of animal squeezes, pens and weighing platforms on the market. We also know that many of our customers are ingenious in how they plan to use the product. For these reasons Massload Technologies has designed the Load Beam scale system to be as versatile as possible, but each installation is different and yet each is the same in how the Load Beams work. The fact that each customer likely has a unique apparatus mounted to their load beam scale system, makes it virtually impossible for us at Massload to provide detailed installation information. We have however, over the years, had a number of customers contact us with some very good ideas that they have incorporated into their installations that would increase the longevity of their scale systems. For the most part components used in the load beam scale system do not fail in normal weighing applications. Having stated this, the one exception may be the Floating Foot assembly when used in an animal weighing application. What typically causes a Floating Foot to fail is from the repeated shocks from animals hitting the head end of the scale platform and or the platform lifting and then slamming down as the animal enters or leaves the scale system. Since about 95% of our customers use the load beams in exactly that application, here are a few suggestions passed on to us by other users in how they put checks in place to limit movement. October, 2008 Over the past number of months a few customers have asked if they can get floating feet that have larger diameter thread than the ½ UNF supplied. This is not possible for the following reason: The four ML100 load cells installed inside the load beams are referred to as Industry Standard cells. This means that exact type, style and capacity of load cell is produced by numerous load cell manufacturers world wide. [This means that should a load cell fail in your system, your local scale service company will have ready access to replacement cells.] As mentioned, Industry Standard load cells are manufactured to be interchangeable and therefore all dimensions including thread size are exactly the same.

***For the purpose of shipping the TI500SL weight indicator has been disconnected from the load beams. Left inside the indicator is a short piece of cable with the wiring connections still in place to the main circuit board. Open the back side of the TI500SL weight indicator and run the cable (from the load beams) inside and make the wire reconnections exactly as those left in place. Procedure for Re-Zeroing Transcell TI 500SL Indicator -Assemble any additional equipment to the weighing portion of the scale that is required for your application. Ensure that the scale is installed level by using the floating feet, and that all of the load cells will be bearing a portion of any load applied. The scale (and add-ons) must be free of interference from anything not part of the scale. -Before turning On or applying power to the indicator, remove the Calibration Switch cover plate, (two silver thumb screws), at the back side of the indicator. Move the exposed switch to the opposite position and then plug in the indicator and turn On by holding the <PRINT> key. F 1 should be displayed. -To set the Deadload (internal re-zero) : Press the <Print> key until F 16 is displayed. Press the <Zero> key. The indicator will do a zero calculation and display a number. Press the <Zero> key once more and the display should now read 0. Press <Net / Gross> key. Wait until F 16 returns to the display. - Move the exposed switch back to the original position and replace the cover plate. - The scale should now be at or around Zero. This whole procedure only has to be done on initial set up of the system. Using the <Zero> key should be all that is required for regular use. *** Making alterations to the values loaded into any of the other F parameters could cause serious problems with your system! Contact factory for assistance.

TI 500SL Power Saving and Lock Functions Note: In the run mode the <Print> key turns the TI500SL ON. In both the run and programming modes holding down the <ZERO> key will turn the indicator OFF. -Before turning On or applying power to the indicator, remove the Calibration Switch cover plate, (two silver thumb screws), at the back side of the indicator. Move the exposed switch to the opposite position and then plug in the indicator and turn On by holding the <PRINT> key. F 1 should be displayed. -Power Saving Using the <Print> or <Tare> keys scroll through the menus until A 10 is displayed. Press the <Zero> key. Using the <Print> and <Tare> keys select the number of minutes that the scale display will stay ON after the last weighing activity took place. When the selection has been made, press the <Net/Gross> key to save that value. (Setting this to Off means the indicator will not turn off automatically.) -Hold Function for animal weighing: {This has not been activated prior to shipment.} Press the <Print> key until A 11 is displayed. Press the <Zero> key. Using the <Print> or <Tare> keys you can select a value of 0 (Hold OFF ) or 1 (Automatic Hold ON ). When the desired value is displayed, press the <Net/Gross> key to save the selection. The Automatic Hold function works as follows: ( Automatic Hold function turned ON.) When a weight is applied to the scale and motion on the scale has settled, the indicator will do an internal averaging and the display will lock on a weight. The TI 500SL will flash the word HOLD on the display as it locks the weight.

This Hold function will hold the display lock until 50% of the locked weight is removed from the scale. There is a way to unlock the display and have it lock on a new weight. To do this press <Tare> and the display will go to 0. Press <Gross/Net> and the display will show the new unlocked weight and then again flash the word HOLD as it locks on the new weight. If this function has been used you will have to press the <Zero> button after the weight has been removed from the scale. **The Hold may be turned on or off as often as you wish by accessing parameter A11 and choosing between values 0 (off) & 1 ( auto on). ***When all programming selections have been made and you wish to exit this mode, move the exposed switch back to the original position and replace the cover plate. Automatic Hold explained a bit more: Although this is not exactly how it happens, it is maybe the best way to attempt to explain the concept. With Automatic Hold turned off (A11 set to 0) the weight indicator processes the weight it sees very quickly and then shows an average of say the last 10 readings that it looked at internally. When an animal is on the scale and moving around, the display continues to constantly look at and average the last 10 readings and showing that on the display. The display, in this case, will appear to be very active and maybe not even be readable at times. When the Automatic Hold feature is turned on, (A11 set to 1), the display will continue to do the same as in the above example with one exception. When the indicator sees 10 readings in a row that did not change more than +/- 5 graduations (counts by), the indicator will automatically lock on the average of those last 10 readings, thus giving a locked weight display. *** Making alterations to the values loaded into any of the other F or A parameters could cause serious problems with your system! Contact the factory for assistance.