Cylindrical fuse-link

Similar documents
Cylindrical fuse-link

AF40... AF96 3-pole contactors Technical data

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Special Purpose Fuses

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Modular contactor for installation into distribution boards

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

MS25, MST25, MS20, MST20

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Page 12-2 Page Page Page DC FUSES FOR PHOTOVOLTAIC APPLICATIONS 10x38mm, IEC class gpv Rated current: 20A Rated voltage: 1000VDC.

Fuse holders and fuses


Vistop TM isolating switches 63 to 160A

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

INDUSTRIAL CYLINDRICAL FUSE LINKS

Approvals UL 508; CSA-C22.2 No ; CSA-C22.2 No. 94; IEC/EN ; CE marking

FUSIBLE DISCONNECT SWITCHES (UL98) GM SERIES

For Info: Phone: Fax:

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Industrial Contactors CTX 3 3P 185A - 800A

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

NEW EFD fuse disconnector

D509E. Manual Motor - Starters

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

fuses fuse holders CYLINDRICAL

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

Safety rope switches with reset for emergency stop

Technical Information

LK Position Switches TECHNICAL DATASHEET.

Low voltage NH knife-blade fuse-links

INNOZED D0 fuse-bases with touch protection

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

UltraSafe US22 Modular fuse-holders

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Varius SUMMARY OF MODELS

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

Modulostar CMS10 Modular fuse-holders

FUSE BASES NH FUSE BASES 690V 160A 160A

Motorized switch-disconnectors OTM 40 to 125 Amperes

DBL distribution blocks 3x1 pole

FUSE-LINKS FOR PHOTOVOLTAIC APPLICATIONS

Electronic overload relays EF205 and EF370

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

ASL09..S 3-pole Contactors - Spring Terminals

CATALOG. EasyLine XLP Fuse Switch Disconnector poles

Safety rope switch with reset for emergency stop

Mini contactors B6, BC6 with 3 pole

Modulostar US10 Modular fuse-holders

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

Auxiliary contact blocks - with spring terminals Accessories

Modular contactors and relays

MS General Information Extended Product Type: MS

Fuse switch disconnectors

fuse-links & fuse holders PHOTOVOLTAIC

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

FL series position switches

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIVERT 1000A Main Incomer, 690VAC

Thermal overload relay TF140DU and TF140DU-V1000

ZS4-SF1 Screw Clamp Terminal Block

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

DC-Switch Disconnectors for Photovoltaic acc. to IEC

Short-circuit current limiter S800-SCL-SR

XACA871 pendant control station XAC-A - 8 pushbuttons

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Safety switches with separate actuator

Fuse switch-disconnectors

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

XACA871 pendant control station XAC-A - 8 pushbuttons

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Transcription:

Cylindrical fuse-link Technical data Rated voltage Rated current Rated frequency Rated breaking capacity Characteristics ody material 00 V AC, 00 V AC, 90 V AC CH 8 - A/00 V CH 0,- A/00 V, 0-3 A/00 V CH - A/90 V, 3-0 A/00 V CH -0 A/90 V (0 A/90 V am), 0-0 A/00 V 0 Hz CH 8 0 ka CH 0 ka CH - A/80 ka, 3-0 A/ ka CH -0 A/80 ka (0 A/80 ka am), 0-0 A/ ka gg, am ceramic With striker pin Material of contact parts CuZn8, gal.ag size e f d d x 3,8 7, x 8 3,8 7, r size a b max. c d min. r øc b b 8 x 3 3,±0,,7 8,±0, ±0, x 38 38,0±0,,,3±0,,±0, x,0+0,/- 3,8,3±0, 7, ± x 8 8,0+0,,,±0, ± a Time current characteristics I/t, gg CH8 t v (s) A A A 8A A AA 0A A Prearcing time (s) 3 0 - - 3 7

Cut-off current characteristics CH8 I o (A) Maximum value of current (A) 3 I K I K 0 8 I n (A) 3 Melting energy characteristics I t CH8 I t (A s) 3 A 0A A 0 0 - - -3 - A A 8A A A A A - 3 8

Time current characteristics I/t, gg CH I t (A t) A A A 8A A A A 0A A 3A Prearcing time (s) 3 0 - - 3 Cut-off current characteristics CH I o (A) Maximum value of current (A) 3 I K I K 3 0 8 0, I n (A) 3 9

I t (A s) Technical data Melting energy characteristics I t CH Time current characteristics I/t, gg CH t (s) 3A A A A 8A A A A 0A A 0A 0A Prearcing time (s) 3 0 - - 3 0

I t (A s) Technical data Cut-off current characteristics CH I o (A) Maximum value of current (A) 3 I K I K 0 0 3 0 8 I n (A) 3 Melting energy characteristics I t CH

Time current characteristics I/t, gg CH t v (s) Prearcing time (s) 3 0 - A 0A A 3A 0A 0A 3A 80A 0A - 3 Cut-off current characteristics CH I o (A) Maximum value of current (A) I K I K 0 80 0 0 0 3 0 3 I n (A) 3

I t (A s) Technical data Melting energy characteristics I t CH Time current characteristics I/t, am CH,, 00 0 0, 8 0 3 0 0 3 80 0 Prearcing time (s) 0. 0.0 0.00 0.000.000 3

Fuse disconnectors for cylindrical fuse-links Technical data EFD EFD 8 EFD EFD CC EFD EFD EFD J30 Fuse type CH 8x3 CH x38 Class CC CH x CH x8 Class J, size J30 IEC IEC UL UL IEC UL IEC UL UL Versions Without indicator/led indicator/neon indicator Without indicator / LED indicator Number of poles p, p+n, p, 3p, 3p+N p, p, 3p p, p+n, p, 3p, 3p+N p, p, 3p p, p+n, p, 3p, 3p+N p, p, 3p Rated operational voltage Ue 00V a.c. 90V a.c. 00V 00V 90V a.c. 00V 90V a.c. 00V 00V Rated operational current Ie 0A 3A 30A 30A 0A 0A 0A 0A 30A Maximum rated current of fuselinks 90V A gg A gg A am 00V A gg 0A gg A am 00V 0A gg A am 0A gg 0A am 0A gg 3A gg 0A am 0A am Rated frequency 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz 0Hz Rated short-time withstand current Icw 0A 300A/s 00A/s 0A/s Conventional free air thermal current Ith 0A 0A Rated conditional short-circuit current 0kA 0kA/00V 0kA 00kA gg: ka/00v (0A gg) am: 0kA/00V (0A am) 0kA gg: ka/00v (0A gg) am: 0kA/00V (0A am) Rated insulation voltage Ui 00V 90V 90V 90V Rated imp. withstand voltage Uimp 8kV 8kV 8kV 8kV Overvoltage category (according to Table H. in IEC 097- and according to IEC 0099-) III III III III Max power dissipation of the fuse-link (W) gg:,w am: 0,9W LED indicator operating range 0V-90V a.c. NEON indicator operating range 0V-70V a.c. gg: 3W am:,w 0V-90V a.c. 0V-70V a.c. 0-00V 3W 0-00V Utilization category AC- AC- Do not operate under load Operational performance (cycles with current) gg: W am: 3W 0V-90V a.c. AC- at 90V/0A 0-00V Do not operate under load gg: 9,W am: 7W 0V-90V a.c. AC- at 90V/0A 300 300 300 300 Operational performance (cycles without current) 700 700 700 700 Humidity 90% at 0 C 90% at 0 C 90% at 0 C Operating ambient temperature - C to +0 C - C to +0 C - C to +0 C Store ambient temperature - C to + C - C to + C - C to + C Degree of protection (IEC 09) IP 0 IP 0 IP 0 IP 0 Terminal capacity -mm -mm AWG 8-8 solid&stranded Cu only,-3mm rigid or flexible AWG - solid&stranded Cu only -0mm rigid or flexible 0kA 0-00V 00kA W 0-00V Do not operate under load AWG - solid&stranded Cu only Screw PZ M PZ M PZ M PZ M PZ M PZ M PZ M PZ M PZ M Torque Nm Nm Nm; 7,7 lb-in,-3nm Nm; 7,7 3Nm 3Nm;, lb-in lb-in Mounting on EN 07 rail 3mm rail Sealing posibility ON and OFF Standards - fuse links IEC/EN 09- IEC/EN 09- IEC/EN 09- UL 8- IEC/EN 09- IEC/EN 09- IEC/EN 09- IEC/EN 09- IEC/EN 09- UL 8-8 IEC/EN 09- Standards - fuse disconnectors/ fuse holders IEC 097- IEC 097-3 UL 8- UL 8- UL 8E CSA C. No. IEC 097- IEC 097-3 UL 8- UL 8E IEC 097- IEC 097-3 UL 8- UL 8E CSA C. No. CSA C. No. UL 8- UL 8-8 UL 8E CSA C. No. CSA C. No. Test reports CCA/C CCA/C UL UL CCA/C UL CCA/C UL UL Certificates UR C US UL C US UR C US UR C US UL C US

Fuse disconnector EFD Fuse disconnector EFD 8, EFD type dimension EFD 8, p 7, EFD 8, p+n 3 EFD 8, p 3 EFD 8, 3p, EFD 8, 3p+N 70 Fuse disconnector EFD CC type dimension EFD CC p 7, EFD CC p 3 EFD CC 3p, Version with adapter Fuse disconnector EFD type dimension EFD p 7 EFD p+n EFD p EFD 3p 8 EFD 3p+N 8 Fuse disconnector EFD & EFD J30 type dimension EFD, J30 p 3, EFD p+n 7, EFD, J30 p 7, EFD, J30 3p,8 EFD 3p+N, PS VLC PS VLC..8. 9.8.. 9 90 90 Auxiliary switch EFD 3. 9.7.7 3. 9.7.7 PS EFD PS EFD

Technical data PCF PCF 8 PCF PCF CC Fuse type CH 8x3 CH x38 Class CC IEC IEC UL UL Versions Without indicator / LED indicator Number of poles p, p+n, p, 3p, 3p+N p, p, 3p Rated operational voltage Ue 00V a.c. 90V a.c. 00V 00V Rated operational current Ie 0A 3A 30A 30A Maximum rated current of fuselinks 90V A gg 00V A gg, A am 00V 0A gg, A am 3A gg Rated frequency 0Hz 0Hz 0Hz 0Hz Rated short-time withstand current Icw 0A 300A Rated conditional short-circuit current 0kA 0kA 00kA 00kA Rated insulation voltage Ui 00V 90V Rated imp. withstand voltage Uimp kv kv Overvoltage category III III Max power dissipation of the fuse-link (W) gg:,w / am: 0,9W gg: 3W / am:,w LED indicator operating range 0V-90V a.c. 0V-90V a.c. 0V-00V 0V-00V Utilization category AC- AC- Do not operate under load Operational performance (cycles with current) 300 300 Operational performance (cycles without current) 700 700 Humidity 90% at 0 C Operating ambient temperature - C to +0 C Store ambient temperature - C to + C Degree of protection (IEC 09) IP 0 IP 0 Terminal capacity 0,-mm, Double connection 0- stranded, Cu only 0- solid&stranded, Cu only Screw PZ M PZ M PZ M PZ M Torque,Nm,Nm,Nm,Nm Mounting on EN 07 rail 3mm rail Sealing posibility ON and OFF Standards - fuse links IEC/EN 09- UL 8-, IEC/EN 09- Standards - fuse disconnectors/fuse holders IEC 097-, IEC 097-3 UL 8- UL 8-, UL 8- Test reports Int. CCA/C UL Int Certificates UR C US Fuse disconnector PCF 3,8,, 83,3 Fuse disconnector PCF 8, PCF, PCF CC type dimension PCF 8,, CC p 7,8 PCF 8, p+n 7,8 PCF 8,, CC p 3, PCF 8,, CC 3p 3, PCF 8, 3p+N 3,,8 Auxiliary switch PS PCF 83.3. 9. 78.7 3.7 9..3