Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Similar documents
NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

NH DIN Dual Indication Fuse Links

NH DIN Dual Indication Fuse Links

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

500 Volts gg/gl NH Fuse links

Leadership in Circuit Protection

Leadership in Circuit Protection

NH Dual NHIndicator Fuse System Fuse System

500 and 690 V a.c. am NH fuse links

Bussmann series NH catalogue. Leadership in circuit protection

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

NH HRC Fuses. IEC & British Standard Fuses NHG B

Bussmann NH Bases. Technical Data Effective October Product description: Standard features:

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

NH LOW VOLTAGE a FUSE SYSTEM

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Bussmann series NH bases

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low-Peak 600V Class RK1

Bussmann series NH photovoltaic fuse links

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Electric vehicle auxiliary fuses 500 Vdc, A

NH photovoltaic fuse links

NH fuse-links gg 500VAC size 000, 00, 0, 1, 2, 3

N0N A 250V One-Time Class H Fuse

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

NH Bases BUSSMANN SERIES. Technical Data Product description. Standard features

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

Class J modular ferrule and knifeblade fuse blocks

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

XL Photovoltaic fuse links


DIN Dual indication fuse links

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

6.3 mm reverse quick connect

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Compact Circuit Protector (CCP)

gg, am NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories NH DIMENSION KNIFE-BLADE FUSE-LINKS, FUSE BASES, AND ACCESSORIES

BH-1 modular fuse blocks, 700 V, 400 A

Compact Circuit Protector (CCP)

Bussmann series Quik-Spec Power Module Switch elevator disconnect

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Bussmann 7.2 kv Medium voltage fuse links

Compact Circuit Protector (CCP)

MEDIUM VOLTAGE DIN Fuse-Links

UL Recognized power distribution blocks

Effective December 2015 Supersedes September 2013

Compact Circuit Protector (CCP)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

IEC and British Standard Fuses.

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Assembly not available for new installations.

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

IEC Low Voltage Products Module 4

MEDIUM VOLTAGE DIN Fuse-Links

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

Red Spot Fuse Holders

LOCKING DEVICES. Features and Benefits: Durable and cost efficient Ease-of-use for do-it-yourself installation All locking devices are UL Listed K3-K5

INDUSTRIAL CYLINDRICAL FUSE LINKS

Compact Circuit Protector

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Circuit Protection Solutions. Low Voltage Fuse Links Catalogue

up to 30A limited by conductor size Operating and storage temperature:

ANR SPECIFICATIONS. MATERIALS RoHS COMPLIANT - E222871

Utilisation category gl/gg 500VAC with combi indicator

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

gi-gl-gg, am gi-gl-gg gi-gl-gg NH DIMENSION KNIFE-BLADE FUSE-LINKS EURO/IEC Fuses & Accessories

Photovoltaic System Overcurrent Protection

Photovoltaic System Overcurrent Protection

Complete and reliable solar circuit protection

IEC CYLINDRICAL FUSE SYSTEM

Red Spot Fuse Holders

C308F 3 mm x 8.4 mm fast-acting, ceramic tube fuses for hazardous applications

Low voltage NH knife-blade fuse-links

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Quik-Spec Coordination Panelboard Specifications

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Bussmann PV Application guide. Complete and reliable solar circuit protection

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Section ( VI ) TECHNICAL SPECIFICATIONS AND SCHEDULES

9000 Series Power Rocker and Lever Handle Switches

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

IEC Low Voltage General Purpose Protection

Bussmann series photovoltaic application guide. Complete and reliable solar fusible circuit protection

Bussmann series IEC cylindrical fuses

fuse-links & fuse holders PHOTOVOLTAIC

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

Transcription:

Description: A range of Class gg/gl square bodied industrial fuse links for a variety of applications. Packaging: MOQ: 3 Catalogue Symbol: Class of Operation: (amp)nhg(size)b-690 gg/gl Fuse Size: 000 to 3 Fuse Holders: Fuse Bases: SD*-D single-pole, TD*-S three-pole Fuse Rails-Vertical: BFR Fuse Switch Disconnectors-Vertical: BFD Fuse Switch Disconnectors-Horizontal: BFH * Select required size of fuse base Standards/Approvals: IEC 60269-1 and 2, DIN 43620 Part 1 and 3 Technical Data: Sizes: 000 to 3 Rated Voltage: 690Vac* : 2 to 500A Rated Breaking Capacity: 120kA** Operating Frequency: 45-62Hz Construction: - Steatite ceramic body - Corrosion resistant aluminium end plates - Corrosion resistant zinc plated plated screws - Silver-plated brass or copper contact blades Environmental 100% Recyclable (including packaging) RoHS Compliant Cadmium and lead free Features Low watts loss Reliable dual indicator system Metal gripping lugs Dimensions - mm Size a1 a2 (max) a3 a4 b1 c1 c2 d1 e1 (max) e2 (max) e3 e4 f1 (max) 000 78.5±1.5 54 45±1.5 49±1.5 15 35±0.8 10 2±0.5 41 21 16 6 8 00 78.5±1.5 54 45±1.5 49±1.5 15 35±0.8 10 2±0.5 48 30 20 6 15 1 135±2.5 75 62±2.5 68±2.5 20 40±0.8 11 2.5±0.5 53 52 20 6 15 2 150±2.5 75 62±2.5 68±2.5 25 48±0.8 11 2.5±0.5 61 60 20 6 15 3 150±2.5 75 62±2.5 68±2.5 32 60±0.8 11 2.5±0.5 76 75 20 6 18 * 160A size 00 rated at 660Vac ** 160A size 00 rated at 50kA

Size 000, 2 to 63 amps Size 000 Time-Current Characteristics Currents in Amps (A) Size 000 Technical Data 2NHG000B-690 2 3.5 8 4 4NHG000B-690 4 6 16 2 6NHG000B-690 6 14 25 2 10NHG000B-690 10 60 400 1. 5 16NHG000B-690 16 240 1200 2.5 20NHG000B-690 20 500 2500 2.5 25NHG000B0690 25 920 4400 3.5 32NHG000B-690 32 1800 9600 3.5 35NHG000B-690 35 2400 12,700 4 40NHG000B-690 40 3300 15,000 4 50NHG000B-690 50 6100 26,500 5.5 63NHG000B-690 63 6500 30,500 5.5 0.118kg

Size 00, 50 to 160 amps Size 00 Time-Current Characteristics Size 00 Technical Data 50NHG00B-690 50 5800 35,000 5 63NHG00B-690 63 5800 43,000 5 80NHG00B-690 80 11,000 54,500 7 100NHG00B-690 100 19,000 92,000 7.5 125NHG00B-690 125 27,500 105,000 9.5 160NHG00B-660* 160 40,500 135,000* 13 0.182kg * 660 Volts, 50kA breaking capacity

Size 1, 50 to 250 amps Size 1 Time-Current Characteristics Size 1 Technical Data 50NHG1B-690 50 6350 26,500 6.4 63NHG1B-690 63 6800 36,000 5.6 80NHG1B-690 80 10,500 47,500 7.7 100NHG1B-690 100 22,000 105,000 8.2 125NHG1B-690 125 29,000 120,000 13 160NHG1B-690 160 71,000 240,000 13 200NHG1B-690 200 105,000 350,000 17 224NHG1B-690 224 120,000 430,000 19 250NHG1B-690 250 150,000 520,000 22 0.380kg

Size 2, 200 to 315 amps Size 2 Time-Current Characteristics Size 2 Technical Data 200NHG2B-690 200 99,000 385,000 18 224NHG2B-690 224 130,000 485,000 20 250NHG2B-690 250 170,000 625,000 23 315NHG2B-690 315 295,000 760,000 32 0.620kg

Size 3, 250 to 500 amps Size 3 Time-Current Characteristics Size 3 Technical Data 250NHG3B-690 250 160,000 715,000 21 315NHG3B-690 315 375,000 1,400,000 22 355NHG3B-690 355 400,000 1,650,000 25 400NHG3B-690 400 475,000 1,600,000 37 425NHG3B-690 425 630,000 1,700,000 35 500NHG3B-690 500 856,000 2,480,000 43 1.048kg The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All othe uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.