CODE MODEL 1RC9020 REC PRO 90 S RC9021 REC PRO 90 S RC9022 REC PRO 90 S RC9023 REC PRO 90 S

Similar documents
HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

Accessories. Series REC

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

RECU-NOVO. heat recovery unit

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

RKB. Heat recovery units from 100 to m 3 /h >50 %

CLOSE CONTROL UNITS WITH CHILLED WATER COIL

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

CONFIGURABLE HIGH-EFFICIENCY HEAT RECOVERY UNITS CADB/T-HE PRO-REG Series

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

The Straight Way. Rectangular Cabinet Fan. Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and heating Products Tunnel Fans

Heat recovery units type GTDHR

VKAP 100 MD/LD 3.0 Product version Motor power level (M higher power level, L lower power level) Diameter Product name. Guard grille.

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

ROOF FAN ROOFMASTER STEC

Heat recovery ventilators with rotating exchanger, automatic control and EC motor, designed for vertical ducts and installation in technical room

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

NCF fans 50 Hz. Protection class IP 55

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

Prepared By : Checked By : Approved By : Page 1 out of 6

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

AQVSL/AQVSH STAR 85 to 140

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Fan coil unit NBS 100/150

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

something new in the air Technical Bulletin

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

BRIZA 22 HYBRID HEATING & COOLING

RS/E-EV MZ SERIES. Modulating Gas Burners FIRING RATES

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

AHN 064 to 304 EHN/CHN 064 to 304

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

CATCH THE OPPORTUNITIES OF NEW REGULATIONS

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

Ultra-quiet circular duct fans TD-SILENT ECOWATT Series

Pressure control damper ERPA

SILENT MV Ultra Quiet In-line Fans

BOX BLB Centrifugal Box Fan

Everest XV. ErP. High Efficiency HRV Fan Unit READY

technical catalogue tetris KW Chiller and heat pumps air/water

Resolair 64 and 68. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 3,900 23,100 m³/h

DIRECT-AIR ILB / ILT Series Rectangular duct fans

TD-MIXVENT Series IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT. In-Line duct fans

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

GigaBox centrifugal fans Product specific information

VEX500 (Everest XH) High Efficiency Bidirectional Fan Unit

series RVV Variable flow rate controllers

IN-LINE CENTRIFUGAL DUCT FANS VT Series

NEW Slimpak EC Box Fan (SLPT EC)

Sentinel D-Box Twin Fan

HEAT RECUPERATORS WITH AIR-AIR CROSS FLOW

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Ventilation and controls for professional kitchens. Controls

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

NCF 60 Hz. Protection class IP 55

WQL/WQH/WQRC 524 to 1204

ED.X Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS. COOLING CAPACITY FROM 6,7 TO 138 kw. ED.X 331 U Kc

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

HFB - Airflow Management Damper HFB. Airflow Management Damper. Product models and Accessories

VAV TERMINAL BOXES TYPE: BA BT

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

IN-LINE MIXED FLOW DUCT FANS TD-MIXVENT Series

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

BASTONE (dual) fancoil Units

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

HIGH EFFICIENCY HEAT RECOVERY UNITS WITH ROTARY WHEEL RHE Series

D M S 760 C01 A A 1 1

Sentinel D-Box Single Fan

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Air Cooled Packaged Units

TD-SILENT Series (160 to 1000 models)

Integreret Combi Cooler system Energieffektiv ventilation og køling. FCUA Fancoil

CENTRIFLOW 3D WITH EC MOTOR >> Technical catalogue

NEW Acoustic In-Line Fans (ACQ)

CENTRIFUGAL FAN COIL UNIT VCE

AQWL/AQWH/AQWR 1404 to 2406

... RTU Technical Manual. Packaged Air Conditioning Unit...

VAV Terminal Units SDS

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Transcription:

REC PRO 9S High efficiency Heat Recovery Units Non residential applications EFFICIENCY 9% Comply with ErP Directive 125/29/CE and EU Regulation 1253/214. Classification: Non Residential Ventilation Unit (NRVU). Bidirectional Ventilation Unit (BVU). DESCRIPTION The heat recovery units of the REC PRO 75 series are designed to match the need to equip the buildings with ventilation systems which can combine low energy consumption, high aeraulic performance and high indoor air quality. They can easily be integrated with conventional heating and air-conditioning systems and their construction is optimized for a ducted installation in false ceilings and for an all-seasons operation. The series is available in 4 sizes with performances ranking from 4. to max 23.5 m 3 /h. 4 sizes Airflow from 4. to 23.5 m 3 /h Very high efficiency static heat exchanger CONSTRUCTION Supporting structure in extruded aluminium profiles Curtain panels 42 mm thick of sandwich type with special sealing gaskets; exterior finish RAL 92 and thermal acoustic mineral wool insulation class and high density. Filtering sections of F7 efficiency class with soft bags on the outside air circuit and M5 on exhaust air circuit, removable from the side. Fan sections with single inlet backward-curved blades plug-fans directly coupled to EC brushless motors. Very high efficiency (>9%) counterflow heat recovery, aluminium heat exchanger plates with supplementary sealing and built-in motorized by-pass device. Complete control panel with remote display and microprocessor for temperature control at fixed air flow, based on the operation logics designed to maximize energy savings and environmental comfort, thanks to the modulation of air flow guaranteed by the inverter technology. The unit is designer for RS485 connection to supervision systems based on Modbus RTU protocol. UPON REQUEST REC 9S can be supplied with the following function components, assembled and connected, to be requested in stage of order: PSTD - Filters differential pressure switch. DPS - Differential pressure sensor. AQS - Ductable CO 2 probe. RANGE CODE MODEL 1RC92 REC PRO 9 S 4. 1RC921 REC PRO 9 S 7.7 1RC922 REC PRO 9 S 11. 1RC923 REC PRO 9 S 13.2

DIMENSIONS (mm) 4 4 L 4 A B 12 H C H CODE MODEL A B C L H L1 L2 L4 W1 H1 KG 1RC92 REC PRO 9 S - 4 2845 136 152 128 64 15 1 535 128 62 73 1RC921 REC PRO 9 S - 77 3175 169 185 161 85 15 1 535 161 785 93 1RC922 REC PRO 9 S - 1 355 22 218 194 97 15 1 535 194 95 115 1RC923 REC PRO 9 S - 132 3835 22 251 194 1135 15 1 535 194 1115 147

PERFORMANCE REC PRO 9S - 4 2 25 3 35 45 5 55 65 7 1 REC PRO 9S - 77 2 5 7 9 1 13 REC PRO 9S - 1 2 7 9 1 13 15 17 19 1 REC PRO 9S - 132 2 9 1 13 15 17 19 2 23 25

PERFORMANCE AND ErP CONFORMITY EU Regulation 1253/214 VENTILAZIONE 9S 4 9S 77 9S 1 9S 132 Airflow rate Static pressure (1) Nom m 3 /h 4 77 1 132 Max m 3 /h 6 175 235 Nom Pa Max 939 129 148 138 Corrente assorbita totale A 7,6 16, 2,5 31,9 Potenza max. assorbita kw 5, 1,4 13,2 2,8 Potenza specifica vent. Nom 937 888 88 927 W/(m 3 /s) Max 186 2384 271 2727 Colnformity 29/125/EC - 215 Protection grade min. - IP 54 Temperature class min. - F Power supply V-Ph-Hz -3-5 Recovery efficiency (1) % 9, 9, 9, 9, Recovery capacity (1) kw 46,4 74,4 11 128 Supply temperature (1) C 18,8 18,8 18,8 18,8 Recovery efficiency (2) % 79,3 79,3 79,3 79,3 Recovery capacity (2) kw 7,8 12,4 18,4 21,3 Supply temperature (2) C 27,2 27,2 27,2 27,2 (1) External air -1 C 9% RH, ambient air +22 C 5% RH (2) External air 32 C 5% RH, ambient air 26 C 5% RH SOUND LEVELS With reference to the nominal operating conditions, the following table reports the sound values (SWL) in octave band and total; it also reports, for comparative purposes, the sound pressure level (SPL) at 1m, 5m and 1m in output, input and outside the unit, in conditions of ducted units. OUTPUT INPUT OUTSIDE MODEL Hz 63 125 25 5 2 TOT 9 S - 4 LwdB(A) 43 51 73 73 72 73 71 67 8 LpdB(A) 6mt 16 24 46 46 45 46 44 4 53 9 S - 77 LwdB(A) 5 59 79 77 78 78 75 75 85 LpdB(A) 6mt 23 32 52 5 51 51 48 48 58 1 m 5 m 1 m 1 m 5 m 1 m 1 m 5 m 1 m db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) db(a) 68 54 45 56 47 42 46 37 32 73 59 53 61 52 47 51 42 37 9 S - 1 LwdB(A) 48 56 8 76 77 78 75 7 85 72 58 52 6 52 47 49 41 36 LpdB(A) 6mt 21 29 53 49 5 51 48 43 58 9 S - 132 LpdB(A) 6mt 26 35 55 53 54 54 51 52 62 76 62 56 63 55 51 52 44 4 LwdB(A) 53 62 82 8 81 81 78 79 88

REC PRO 9S ACCESSORIES SKE CCS V33 TPR - TPR CCS SKR SSE MS3 SSE FC6 FT7 FT8 CFA GAT TPR DPSa DPSp Electric heater External module of heating/cooling with water coil and 3-way valve Roof cover - Roof cover for CCS Air damper with on/off actuator Mix /discharge chamber Additional filter Class M6 on the external air intake Sleeve filter Class F7 on internal air intake Sleeve filter Class F8 on the external air intake (to pair with FC6) External cuff Flexible connection Roof cover Differential pressure sensor at constant flow Differential pressure sensor at constant pressure CODE MODEL SKE1 Pre SKE1 Post SKE2 Pre SKE2 Post high high low low MS3 SSE CCS V33 TPR CCS SKR SSE MS3 SSE mod. FC6 FT7 FT8 CFA high CFA low GAT TPR TPR CCS DPSa DPSp TPR MS3 1RC92 REC PRO 9 S 4. 5BT3 5BT34 5BT38 5BT312 5BT316 5TE27 5SE1 5PL1 5PL14 5FL435 5FL439 5FL443 5SU2 5SU24 5SU28 5TE278 5TE27 5SU15 5SU16 5TE274 1RC921 REC PRO 9 S 7.7 5BT31 5BT35 5BT39 5BT313 5BT317 5TE271 5SE11 5PL11 5PL15 5FL436 5FL44 5FL444 5SU21 5SU25 5SU29 5TE279 5TE271 5SU15 5SU16 5TE275 1RC922 REC PRO 9 S 11. 5BT32 5BT36 5BT31 5BT314 5BT318 5TE272 5SE12 5PL12 5PL16 5FL437 5FL441 5FL445 5SU22 5SU26 5SU3 5TE28 5TE272 5SU15 5SU16 5TE276 1RC923 REC PRO 9 S 13.2 5BT33 5BT37 5BT311 5BT315 5BT319 5TE273 5SE13 5PL13 5PL17 5FL438 5FL442 5FL446 5SU23 5SU27 5SU31 5TE281 5TE273 5SU15 5SU16 5TE277 SKE - Electric heater MODEL 4 77 1 132 Power 1 28 48 64 8 kw 2 14 24 32 4 Pressure loss air intake side (1) 1 < 25 Pa 2 < 17 Power supply V-ph-Hz - 3-5 SKE1 - PRE-HEATING - High Power 5BT3 SKE 1 - pre-heating 9S 4 5BT31 SKE 1 - pre-heating 9S 77 5BT32 SKE 1 - pre-heating 9S 1 5BT33 SKE 1 - pre-heating 9S 132 SKE1 - POST-HEATING - High Power 5BT34 SKE 1 - post-heating 9S 4 5BT35 SKE 1 - post-heating 9S 77 5BT36 SKE 1 - post-heating 9S 1 5BT37 SKE 1 - post-heating 9S 132 SKE2 - PRE-HEATING - Low Power 5BT38 SKE 2 - pre-heating 9S 4 5BT39 SKE 2 - pre-heating 9S 77 5BT31 SKE 2 - pre-heating 9S 1 5BT311 SKE 2 - pre-heating 9S 132 SKE2 - POST-HEATING - Low Power 5BT312 SKE 2 - post-heating 9S 4 5BT313 SKE 2 - post-heating 9S 77 5BT314 SKE 2 - post-heating 9S 1 5BT315 SKE 2 - post-heating 9S 132 (1) At nominal airflow CCS V33 - External module of heating/cooling with water coil and 3 way valve External module that directly interfaces to the unit output section. It includes a 4-row water battery, suitable for both heating and cooling, a plastic drop separator, a 3-way valve with 3-point servomotor (supplied aside) and a side discharge of 1. For performance consult the following table, referring to the nominal airflow: MODEL 9S 4 9S 77 9S 1 9S 132 CODE 5BT316 5BT317 5BT318 5BT319 Refrigeration (1) total 4,9 69 16,3 119,8 kw sensibile 22,9 38,6 58,5 65,9 Thermal (2) kw 35,4 58,5 89,1 12,5 Water flow (1) l/h 7.35 11.877 18.289 2.69 Pressure loss water intake side (1) kpa 15 18 19 11 Pressure loss air intake side (1) Pa 164 142 13 118 (1) Air intake 27,5 C 6% RH, water in/out 7/12 C (2) Air intake 18 C, water in/out 45 /4 C

REC PRO 9S ACCESSORIES SKR SSE - Air damper SKR SSE - Air damper 5SE1 SKR SSE 9S 4 5SE11 SKR SSE 9S 77 5SE12 SKR SSE 9S 1 5SE13 SKR SSE 9S 132 FT7 - Sleeve filter FT7 - Sleeve filter 5FL439 FT7 9S 4 5FL44 FT7 9S 77 5FL441 FT7 9S 1 5FL442 FT7 9S 132 MS3 SSE - Mix / Discharge chamber CODE DESCRIPTION 5PL1 MS3 SSE 5 5PL11 MS3 SSE 92 5PL12 MS3 SSE 144 5PL13 MS3 SSE 25 5PL14 MS3 SSEmod 5 5PL15 MS3 SSEmod 92 5PL16 MS3 SSEmod 144 5PL17 MS3 SSEmod 25 FC6 - Compact filter M6 FC6 - Compact filter M6 5FL435 FC6 9S 4 5FL436 FC6 9S 77 5FL437 FC6 9S 1 5FL438 FC6 9S 132 FT8 - Sleeve filter F8 FT8 - Sleeve filter F8 5FL443 FT8 9S 4 5FL444 FT8 9S 77 5FL445 FT8 9S 1 5FL446 FT8 9S 132 DPS - Differential pressure sensor DPS - Differential pressure sensor 5SU15 DPSa 5SU16 DPSp GAT - Flexible connexion CFA - External cuff with net GAT - Flexible connexion 5SU28 GAT 9S 4 5SU29 GAT 9S 77 5SU3 GAT 9S 1 5SU31 GAT 9S 132 CFA/A - External cuff with net - High 5SU2 CFA/A 9S 4 5SU21 CFA/A 9S 77 5SU22 CFA/A 9S 1 5SU23 CFA/A 9S 132 CFA/B - External cuff with net - Low 5SU2 CFA/B 9S 4 5SU21 CFA/B 9S 77 5SU22 CFA/B 9S 1 5SU23 CFA/B 9S 132 TPR - TPR/CCS - TPR/MS3 Roof cover - Roof cover for CCS TPR - Roof cover 5TE278 TPR 9S 4 5TE279 TPR 9S 77 5TE28 TPR 9S 1 5TE281 TPR 9S 132 TPR/CCS - Roof cover for CCS 5TE27 TPR/CCS 5 per REC PRO 9 S - 4 5TE271 TPR/CCS 92 per REC PRO 9 S - 77 5TE272 TPR/CCS 144 per REC PRO 9 S - 1 5TE273 TPR/CCS 25 per REC PRO 9 S - 132 TPR/MS3 - Roof cover for MS3 5TE274 Roof for MS3 5 - REC PRO 9 S & 8 R 5TE275 Roof for MS3 92 - REC PRO 9 S & 8 R 5TE276 Roof for MS3 144 - REC PRO 9 S & 8 R 5TE277 Roof for MS3 25 - REC PRO 9 S & 8 R