INSTALLATION MANUAL. PRVC2 is available only for the Multi-V IV model (PRVC2 can not be installed for the previous Multi-V IV model)

Similar documents
LOW AMBIENT COOLING KIT INSTALLATION MANUAL

Installation Manual. Low Ambient Cooling Kit. ZLABKA01A Low Ambient Cooling Kit. ZLABKA02A Low Ambient Cooling Kit

LG Power Distribution Indicator

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Direct Coupled Damper Actuator Model MY6050A1001

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

CAUTION. Disconnect Power

Air Conditioner. Installation manual. Wired remote controller MWR-WE11N

LG AHU Control Kit / EEV Kit

Remote Control Engine Starter System Owner s Manual

INSTALLATION MANUAL FOR LG AIR HANDLER UNIT (AHU) COMMUNICATIONS KIT. AHU Model Number: PRCKAM

IMPORTANT ATTENTION INSTALLERS:

QUADSCAN User s Guide Door Mounted Presence sensor

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Installation Instructions

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Quick Start Guide TS 910

General Precautions. Personnel Precautions

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

Quick Start Guide TS 910 & TS 920

Submersible Turbine Pump (Volute) STM type (T, TU, and TU3) SSTM type (TUA)

Direct Coupled Damper Actuator Model MY9050A1001

Instruction Manual LAMI CORPORATION INC.

CBM-105FN/FP Circuit Board

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

Technical Documentation

Battery Unit BHM60PC/BHM100PC Instruction Manual

Type 2000 Transducer Product Instructions

XeVision XeRay XV-LX50 HID Searchlight

PANcharge1k Battery Charger User's Manual

DRL-1 Series Instruction Manual

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Manual for Control Panel

ACCUVALVE MODEL AVC6000 SUBMITTAL MATERIALS MODEL CODE. AccuValve Model AVC6000 AVC6 - - DWG. NO: REVISION: REV. DATE:

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

BATTERY CHARGER Instruction Manual

Series 10-ZSE40A(F)/10-ISE40A

POWER REGULATOR LD -40PSU

Installation Instructions

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

DRB-1 Series Instruction Manual

Submersible Mixed Flow/Axial Flow Pump Model SAM Model SPM

Safety & Installation Instructions

HEAVY DUTY POWER RELAYS FEATURES

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Model Number Structure

Minimum 27 in-lb torque

Extended Panel Operation Manual RKP001Z-0

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

Switching DC Power Supply

PTAC CONTROL BOARD KIT RSKP0006 INSTALLATION INSTRUCTIONS

RP Instruction Manual

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Installation Instructions

Installation/ Operation Maintenance. VariTrac Dampers

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

Versatile and Powerful

Vission 20/20 micro-controller. Operation and service manual Version 2.6

EVS RP6020. Instruction Manual

Additional Battery Unit BUM100RE Instruction Manual

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

WheelieSafe. WheelieSafe. User Manual. Motorized Trolley. Distributor:

No Operation of air conditioner Explanation

Designed for ease of integration with automation systems

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

Pure Sine Wave Inverter Charger

Freedom egen System End-of- Line Functional Checklist

Lumitester PD-20 Control Kit

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Source Capture Air Purification System

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Chapter 4 Installation Guide

SHOCK RELAY R INSTRUCTION MANUAL WARNING

PCT-3001 plus. Display LCD

Carbon Monoxide Transmitter

보조전원모듈 _MCM-C210_IM_EN_03929A(2).indd 오후 12:29:00

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Where There is Miboxer There is Power. User Manual. Model No.: C2-6000

OnCommand Troubleshooting Guide Hayward Industries

English. Instruction and operation manual S 212. Dew point sensor

VL-100U5-E (pull cord type) VL-100EU5-E (wall switch type)

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: Dec., 2015 Version: 1.1

AC Induction Motors. Installation and operating instructions

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU18RLXFW AOU24RLXFW ASU18RLF ASU24RLF R410A

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Combined Ventilation Controller RVWS-T-224HA

Fault Codes. J control

Operators Guide: RoboSign Stop/Go Traffic Control System

Transcription:

INSTALLATION MANUAL Low Ambient Control Kit Please read this installation manual completely before installing the product. Installation work must be performed in accordance with the national wiring standards by authorized personnel only. Please retain this installation manual for future reference after reading it thoroughly. MODEL : PRVC2 PRVC2 is available only for the Multi-V IV model (PRVC2 can not be installed for the previous Multi-V IV model) www.lg.com P/NO : MFL42540228

Low Ambient Control Kit Installation manual TABLE OF CONTENTS Safety Precautions...3 Accessory Parts...6 Name of each Part...7 Installation Method...8 1. IO Module Installation Method...8 2. Transformer, Terminal Block Installation Method...10 Setting and Using Method...12 1. Wiring Diagram...12 2. Power Source Input...13 3. IO Module - Low Ambient Kit Function...15 4. IO Module Other Function...16 5. Wiring for Damper Actuator...19 6. Setting of Outdoor Unit Dip Switch...22 Installation Method of Snow Hood and Air Damper...23 1. One Unit with Snow Hood and Air Damper...23 2. Two and Three Units with Snow Hood and Air Damper...24 3. Unit Placement and Clearances...25 2 Low Ambient Control Kit

Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage. Meanings of symbols used in this manual are as shown below. Safety Precautions Be sure not to do. Be sure to follow the instruction. WARNING Installation Don t touch with the hands while the power is on. Cause fire, electric shock, explosion or injury. Product installation must be referred to a service center or installation shop. Cause fire, electric shock, explosion or injury. Request installation from installation shop or service center when reinstalling the product. Cause fire, electric shock, explosion or injury. Service Center Service Center Installation manual 3

Safety Precautions Do not install the product in the place where rain can get to the product. Cause product failure Do not install the unit in humid locations. Cause product failure Do not put the product closer to fire. Cause fire Do not install in a place that cannot withstand the weight of the product. The product may get damaged or may break. Do not install the product to a place that generates oil, steam, salt, sulfuric gas, etc. Cause the product s deformation or failure. Use standardized Product. Cause product failure Standardized product Operation Do not change or extend power lines arbitrarily. Cause fire or electric shock. Do not give a shock to the product. If you give a shock to the product, it may cause the product s failure. Do not use a heater near the power line. Cause fire or electric shock. 4 Low Ambient Control Kit

Safety Precautions Do notspill water inside of the product. Cause electric shock or breakdown. If the product has been inundated, you must refer to a service center or installation shop. It can cause a fire. Children and elderly use the product under the guardian s supervision. Cause accidents and product failures. Service Center Do not use for special purpose / place such as conserving flora and fauna, precision instruments, art. Otherwise, it can cause property damage. Remove the power plug when cleaning. Cause fire or electric shock. Do not place heavy objects on the power line. Cause fire or electric shock. Do not disassemble, repair, or modify the product. Cause fire or electric shock. Do not touch with wet hands. Cause fire or electric shock. STOP Installation manual 5

Accessory Parts Accessory Parts IO Module Bracket 1 Terminal Block (2EA) Bracket 2 Screw (9EA) Manual Cable (3EA) Tie (2EA) Transformer Clamp 6 Low Ambient Control Kit

Name of each Part Name of each Part 1 Main connector : Power input and communication connector with Outdoor unit 2 SW104 : Rotary Switch for setting Demand control step 3 Digital Output : Operating & Error status Relay output (250V, 1A) 4 SW102 : Switch for setting internal function 5 Digital Input : Dry contact input 6 Analog Input : DC0~10V Analog signal input 7 Analog Output : DC0~10V Analog signal output 8 SW103 : Reset Switch 9 SW101 : Dip Switch for setting operating function Installation manual 7

Installation Method Installation Method 1. IO Module Installation Method 1 Separate front panel from outdoor unit. 2 Separate front cover of control box. 3 Assemble IO Module and bracket. 4 Connect the connection wires according to the instructions. (Please refer to Setting and Using Method) + Main board connector CAUTION Be sure to turn off outdoor unit power before installation. 8 Low Ambient Control Kit

Installation Method 5 Fix and fasten components and cables. 6 Perform the switch setting according to the instructions. Installation manual 9

Installation Method 2. Transformer, Terminal Block Installation Method 1 Shut off the main power of outdoor unit. 2 Install the IO Module in the C/Box by using screws. 3 Install the Bracket2 in the C/Box by using screws. 4 Install the transformer on the Bracket2 by using screws. 5 Install the terminal block on the Bracket2 by using screws. 6 Connect the Main PCB(CN10) to IO Module(CN101) by using the cable assembly. 7 Connect the blue cable of transformer to the Main PCB(JIG_N), brown cable of transformer to the Main PCB(JIG_L). 8 Connect the red cable of transformer to the terminal block (2Pin Yellow terminal block). 9 Connect a power cable(dc 12V) to CN101(12V,GND) of IO Module. 10 Connect the black cable of Damper Actuator to the terminal block and connect the cable of IO Module(CN1_A0(GND(A-)) to the black cable of Damper Actuator. 11 Connect the red cable of Damper Actuator to CN1_A0(A0_1(A+)) of IO Module. 12 Set up the main function Dip S/W of IO Module. (SW101 : L1,L2=On and L3,L4=Off / SW102 : L1,L2=Off) 13 Set up the Dip S/W of Main Outdoor unit PCB. (Refer to page 21 for details) 14 Turn on the main power of outdoor unit. 15 Check the signal to CN1_A0(AO_01,GND) of IO Module and Air Damper. Clamp Transformer Bracket 2 Terminal Block + 10 Low Ambient Control Kit

Setting and Using Method Using the Clamp and Tie, fasten the Damper Actuator output cable and Trans output cable as below. Actuator Wire Installation manual 11

Setting and Using Method Setting and Using Method 1. Wiring Diagram 12 Low Ambient Control Kit

Setting and Using Method 2. Power source input Power AC or DC Power AC or DC Error Status Operating Status AO_4 AO_3 AO_2 AO_1 Priority setting Reserved Input_LNO Input_3 Input_2 Input_1 AI_1 Reserved AI : Analog Input (DC0~10V) AO : Analog Output ( DC0~10V, Max 20mA) Input_LNO : Low Noise Operation 1 Dry contact input part Connect Non Voltage contact signal for demand control (3 step) * Priority setting Using Priority setting contact signal, set the priority of command. (External command from DDC Vs Command from LG central controller.) - Close : Central controller has priority to external signal. - Open : External signal has priority to central controller. 2 Analog input part Connect Analog input signal for demand control (10 step) 3 Analog output part Connect Analog output signal for controlling third party devices. Ex) Valve actuator for variable water flow. Damper actuator for Low Ambient Kit 4 Digital output part Connect status display devices. CAUTION Power must be turned on after the product is wired completely. Installation manual 13

Setting and Using Method Communication and Power Line - If communication and power lines are run alongside each other then there is a strong likelihood of operational faults developing due to interference in the signal wiring caused by electrostatic and electromagnetic coupling. The tables below indicates our recommendation as to appropriate spacing of communication and power lines where these are to be run side by side. Current capacity of power line 10A Spacing 11-13/16 in (300 mm) 100V or more 50A 100A Exceed 100A 19-11/16 in (500 mm) 39-3/8 in (1,000 mm) 59-3/64 in (1,500 mm) Notes If the power supply waveform continues to exhibit some distortion the recommended spacing in the table should be increased. If the lines are laid inside conduits then the following point must also be taken into account when grouping various lines together for introduction into the conduits. Power lines (including power supply to air conditioner) and signal lines must not be laid inside the same. In the same way, when grouping the lines power and signal lines should not be bunched together. 14 Low Ambient Control Kit

Setting and Using Method 3. IO Module - Low Ambient Kit Function Setting of Dip Switch Using SW101, SW102, You can use Low Ambient Kit Mode SW102 ON L1 2 3 4 ON L1 2 SW101 Notes Default status is all off. Set Low Ambient Kit Operation Position ON L1 2 3 4 SW101 - L1=ON L2=ON L3=OFF L4=OFF Setting of Dip Switch ON L1 2 SW102 - L1=OFF L2=OFF CAUTION If the Dip SW is set, IO module System is operating preferentially than outdoor unit setting. After change Dip SW setting, press reset switch to reflect the setting. Installation manual 15

Setting and Using Method 4. IO Module Other Function Setting of Dip Switch Using SW101, select the option of control function as described below. ON L1 2 3 4 Notes Default status is all off. L3 : Set Low Noise Operation This is a function driving outdoor unit fan RPM to operate low speed for reducing fan noise according to the input signal. To use this function, you should set Outdoor unit mode, Please refer to PDB more detail. Position Function ON L1 2 3 4 ON : Enable Low Noise Operation OFF : Disable Low Noise Operation CAUTION If the Dip SW is set, IO module System is operating preferentially than outdoor unit setting. L4 : Set Operating status output Position Function ON L1 2 3 4 ON : Activate Digital Output according to Indoor Unit status OFF : Activate Digital Output according to Outdoor Unit status CAUTION After change Dip SW setting, press reset switch to reflect the setting. 16 Low Ambient Control Kit

Setting and Using Method Using SW102, set the internal function as described below. ON L1 2 Notes Default status is all off. L1 : Set Analog output default value when Communication Error will be occur (Module ODU) Position Function ON L1 2 ON : Analog output 0V OFF : Analog output 10V L2 : Set Analog output Range Basically this module keeps a minimum Analog output voltage refer to L1,L2 setting of SW101 to prevent unexpected accident. When you need to use 0~10V full range, L2 should be set as ON. Position Function ON L1 2 ON : Ignore minimum Analog output value setting (L1,L2 setting value of 4pin Dip SW) OFF : Follow minimum Analog output value setting (L1,L2 setting value of 4pin Dip SW) CAUTION After change Dip SW setting, press reset switch to reflect the setting. Installation manual 17

Setting and Using Method Setting of Rotary Switch Use the Rotary Switch to set a control step for contact signal input : The type of input signal and control step can be set using SW104 This function is for demand control to reduce power consumption. Set the control mode what you want according to the table as below. - Type of input signal SW_STEP Input signal 0, 1, 2, 3, 4, 5, 6, 7 Contact signal input C, D, E Analog input signal CAUTION Do not change a command too quickly. Keep the command 30 seconds at least, otherwise it will cause a damage to outdoor unit. Operation rate condition : - Cooling : Outdoor 35 C, Indoor 27 C - Heating : Outdoor 7 C, Indoor 20 C The tolerance of the operation rate can be cause by combination of outdoor unit, operating condition, installation circumstance. When operation rate is 100%, Target Evaporating Temp. and Target Condensing Temp. can be changed by installation option. (Refer to product data book) Input_1 : 0 Έ OFF, Input_1 : 1 Έ ON 18 Low Ambient Control Kit

Setting and Using Method 5. Wiring for Damper Actuator 1 Unit Power Module Main PCB BL BR Transformer AC 220V IO Module Damper Actuator RD RD Terminal Block WH GR DC 0~10V Control Signal BK RD AC/DC 24V BL : Blue, BR : Brown, RD : Red, BK : Black, WH : White, GR : Green Notes Damper Actuator can accept only DC 24V power input. Do not input AC power. Otherwise it will cause a serious damage. The IO Module can control maximum three actuators. Case of one valve, the slave signal connector must not use. The power (AC/DC 24V) and signal(dc 0~10V) line is recommended by AWG22(1/32 in, (0.644 mm), 0.016 Ω/ft (0.053 Ω/m)). Installation manual 19

Setting and Using Method 2 Unit Power Module Main PCB BL BR Transformer AC 220V IO Module Damper Actuator Damper Actuator RD RD Terminal Block RD BK GR GR WH WH BK RD BK RD Notes Damper Actuator can accept only DC 24V power input. Do not input AC power. Otherwise it will cause a serious damage. The IO Module can control maximum three actuators. Case of one valve, the slave signal connecter must not use. The power (AC/DC 24V) and signal(dc 0~10V) line is recommended by AWG22(1/32 in, (0.644 mm), 0.016 Ω/ft (0.053 Ω/m)). 20 Low Ambient Control Kit

Setting and Using Method 3 Unit Power Module Main PCB BL BR Transformer AC 220V IO Module Damper Actuator Damper Actuator Damper Actuator RD RD Terminal Block RD BK GR GR GR WH WH WH BK RD BK RD BK RD Notes Damper Actuator can accept only DC 24V power input. Do not input AC power. Otherwise it will cause a serious damage. The IO Module can control maximum three actuators. Case of one valve, the slave signal connecter must not use. The power (AC/DC 24V) and signal(dc 0~10V) line is recommended by AWG22(1/32 in, (0.644 mm), 0.016 Ω/ft (0.053 Ω/m)). Installation manual 21

6. Setting of Outdoor Unit Dip Switch Low Ambient Kit Mode Low Ambient Kit mode Setting method Master unit PCB DIP switch on : No.5 Select the mode using, Button : Func Push the ' ' (Confirm) button Select the Function using, Button : Fn10 or Fn11 Push the ' ' (Confirm) button DIP SWITCH 7-Segment SW04C ( X : cancel) Select the Function using, Button : On Push the ' ' (Confirm) button Low Ambient Kit mode is set SW03C ( : forward) SW02C ( : backward) SW01C ( : confirm) SW01D (reset) If you want to stop the Low Ambient Kit mode, refer to the following. Dip Switch No.5 On -> Func -> Fn10 -> Off Fn10 Model : ARUB***BTE4 ARUB***DTE4 ARUB***LTE4 Fn11 Model : ARUN***BTE4 ARUN***DTE4 ARUN***LTE4 ARUN***LTS4 22 Low Ambient Control Kit

Installation Method of Snow Hood and Air Damper Installation Method of Snow Hood and Air Damper 1. One Unit with Snow Hood and Air Damper One Unit with Snow Hood and Air Damper Installation manual 23

Installation Method of Snow Hood and Air Damper 2. Two and Three Units with Snow Hood and Air Damper Two Units with Snow Hood and Air Damper Three Units with Snow Hood and Air Damper 24 Low Ambient Control Kit

3. Unit Placement and Clearances Installation Method of Snow Hood and Air Damper 1. Outdoor units should be located in an area protected from prevailing winds. (shown below) In high wind locations it may be advisable to locate the units within a walled area. Top View Prevailing wind Building Wall Outdoor Unit 2. If the units are surrounded by an enclosure, the discharge of the air damper must direct the air out and over the enclosure walls to prevent air recirculation. H discharge of air damper Installation manual 25

Installation Method of Snow Hood and Air Damper 3. When the distance is less than 7-7/8in(200mm) between outdoor units, do not necessary installation of side Snow Hood as below. 7-7/8in(200mm) 7-7/8in(200mm) 7-7/8in(200mm) 26 Low Ambient Control Kit

Installation Method of Snow Hood and Air Damper 4. If units are placed further than 7-7/8in(200mm) apart, additional snow hoods may be required. Installation manual 27

Installation Method of Snow Hood and Air Damper 28 Low Ambient Control Kit