DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

Similar documents
DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

ANTI-SYPHON VALVE INSTALLATION GUIDE

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

RIGID ENTRY BOOT INSTALLATION GUIDE

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

SEALING DIP CAP INSTALLATION GUIDE

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

DEFENDER SERIES OVERFILL PREVENTION VALVE INSTALLATION GUIDE

SMART CONTROLLER I INSTALLATION GUIDE

DEFENDER SERIES BELOW GRADE DOUBLE WALL SPILL CONTAINER INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

High Capacity Submerged Turbine Pumps

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

DC400 Dispensing Cutoff System

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

STP SUBMERGED TURBINE PUMP IST INTELLIGENT SUBMERSIBLE TURBINE. Variable Length

STP / IST Fixed & Variable Length

STP-MLD Installation and Owner s Manual

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

STP-MLD. Installation and Owner s Manual

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

3 Phase Smart Controller

Vapor Recovery Assist System

Pro 30 Plus Gas Caddy

MR 5-30 Aviation Fuel Meter Owner s Manual

MECHANICAL FUEL METER. FM-100 and FM-200 Series Owner s Manual

M-3025CB-AV Fuel Pump

MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

Vapor Recovery Central Vacuum System

IMPORTANT INFORMATION

INSTALLATION, OPERATION, SERVICE & REPAIR PARTS MANUAL FOR

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

1/2" AIR DRIVEN DIAPHRAGM PUMP

Polypropylene Piston Drum Pumps

Purpose Of This Document This manual provides the information to assemble and install Lighted Canopy Conduit Kits on The Advantage Series.

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

Installation. Introduction

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

Dispenser Pan Sensors & Containment Sump Sensors

Hose reels for diesel exhaust fluid (DEF)

Wall mount PMV pump with suction kits and hoses

Tire Bead Seater. Explanation of Safety Signal Words. The safety signal word designates the degree or level of hazard seriousness.

OWNER'S MANUAL SAVE THESE INSTRUCTIONS

CM-3120 (115-volt, NPT, Gallon or Litre) CM-3220 (230-volt, NPT, Gallon) CM-3260 (230-volt, BSPT, Litre) Heavy Duty Cabinet Model Fuel Transfer System

Introduction 1 Important Safety Information 3 Installing TopKAT Series 900 Replacement Report Printer Kit 5

PRO PRO20-115RD 115-Volt AC. PRO Volt AC OWNER'S MANUAL SAVE THESE INSTRUCTIONS

Galaxy VM. Battery Breaker Box Installation 09/

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Propane torch. Model Assembly And Operation Instructions

Operating Instructions

Underground Tank Applications Installation Guide

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

Oil Pump Models L 5016, L 5116 & L 5132

Dispenser Pan Sensors & Containment Sump Sensors

IMPORTANT INFORMATION

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

EZ FIT SYSTEM FLEXIBLE CONNECTORS: SERVICE STATION HARDWARE

Hydraulic PTO Flow Device

Installing the CO 2 Cryogenic Oven Cooling Kit

Hydraulic Immediate Need Power Pack

ADI-125/750 ADI-125/1500 ADI-125/2500

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

SUPER PUMP OUT SYSTEM

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

AUTOGAS 150 SERIES PUMPS INSTALLATION GUIDELINES FOR UNDERGROUND TANK APPLICATIONS

Type 4 Cylinder Owner s Manual

Pressurized oil drain for collection of used lubricants and anti-freeze.

Tuffy Liquid Level Controls with Pneumatic Switch

Electronic lube meter

Operating and Installation Instructions

fusion RF Control Handle

Series K Pneumatic Switch Mechanism

QUALITY MISTING PUMPS

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

STOP. Oil Pump Models L 5016, L 5116 & L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

UNDERCARRIAGE KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Owner s Manual & Safety Instructions

OPERATOR S MANUAL A

Model 1000 Low Profile Tailgate Spreader Receiver Mount

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

S T O P. Oil Pump. Models L 5016, L 5116 and L Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS TABLE OF CONTENTS

Required Tools and Materials Following tools and materials are required to install the Boot Switch Kit: Nut Driver Heat Gun Thread Lock

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

Installation and Maintenance Instructions 44TA Liquid Level Float Switch

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Transcription:

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained in this manual at the time of printing, we recommend that you refer to franklinfueling.com for the most current version of this manual. All product specifications, as well as the information contained in this publication, are subject to change without notice. Franklin Fueling Systems does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of, or in any way connected with, installation, operation, use, or maintenance by using this manual. Franklin Fueling Systems assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of this manual or the products. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 2017 Franklin Fueling Systems, Madison, WI 53718. All world rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including, but not limited to, photocopy, photograph, magnetic, or other record, without the prior written permission of Franklin Fueling Systems. For assistance, please contact: Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA and Canada Technical Support: +1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 France: +33 (0) 1.69.21.41.41 China: +86.10.8565.4566 EZ FIT is a registered trademark of CommScope, Inc. 403414001 r3

Contents Introduction...1 Conventions used in this manual...1 Operating precautions...2 Questions and concerns...3 Installing DEF Pumping Accessories...5 Typical DEF-PMA installation...6 60 Hertz variable-length DEF-STP replacement kits...7 Accessories and repair parts...7 50 Hertz variable-length DEF-STP replacement kits...8 Accessories and repair parts...8 60 Hertz fixed-length DEF submersible turbine pump kits...9 Accessories and repair parts...9 50 Hertz fixed-length DEF submersible turbine pump kits...10 Accessories and repair parts...10

Intentionally Blank

Introduction Diesel Exhaust Fluid (DEF) is a non-flammable, non-combustible liquid with a specific gravity of 1.09 at 20 C (68 F) and is made according to ISO 22241-1 specifications. It is composed of 32.5% urea and distilled or deionized water. DEF is used in diesel vehicles that are equipped with Selective Catalytic Reduction (SCR) emission control. DEF freezes at -11 C (12 F) and can be impaired by prolonged storage above 25 C (77 F). DEF systems require compatible materials to prevent product contamination / degradation and unintended release. DEF Pumping Accessories are intended for use only with DEF and in conjunction with DEF Pump Motor Assemblies (PMA) models. DEF-PMA models are suitable for vertical installation where the pump motor is suspended off the bottom of the storage tank by the discharge piping. DEF-PMA models are rated for continuous operation with motor cooling provided by product flow and protected from dry running. DEF-PMA models require a Bypass Relief Valve with a cracking pressure of 30-40 psi (2.1-2.8 bar) and capable of 4 gpm (15 lpm) minimum flow at the Discharge Outlet. DEF-PMA models require a Non-Return Check Valve with a maximum cracking pressure of 3 psi (0.2 bar) between the product piping and the Bypass Relief Valve. Three-phase DEF-PMA models require overload protection in the motor starter, whereas single-phase DEF-PMA models have thermal overload protection built into the motor. Conventions used in this manual This manual includes safety precautions and other important information presented in the following format: NOTE: This provides helpful supplementary information. IMPORTANT: This provides instructions to avoid damaging hardware or a potential hazard to the environment, for example: fuel leakage from equipment that could harm the environment. CAUTION: This indicates a potentially hazardous situation that could result in minor or moderate injury if not avoided. This may also be used to alert against unsafe practices. WARNING: This indicates a potentially hazardous situation that could result in severe injury or death if not avoided. DANGER: This indicates an imminently hazardous situation that will result in death if not avoided. 1

Operating precautions Franklin Fueling Systems (FFS) equipment is designed to be installed in areas where volatile liquids such as gasoline and diesel fuel are present. Working in such a hazardous environment presents a risk of severe injury or death if you do not follow standard industry practices and the instructions in this manual. Before you work with or install the equipment this manual pertains to, or any other related equipment, read this entire manual, particularly the following: CAUTION: Do not modify the DEF pump accessories. Modifying or altering these accessories in any way defeats the rigorous quality control tests performed during assembly and could result in dangerous safety issues. WARNING: Follow all codes that govern how you install and service this product and the entire system. Always lock out and tag electrical circuit breakers while installing or servicing this equipment and related equipment. A potentially lethal electrical shock hazard and the possibility of an explosion or fire from a spark can result if the electrical circuit breakers are accidentally turned on while you are installing or servicing this product. Refer to this manual (and documentation for related equipment) for complete installation and safety information. WARNING: Before you enter a containment sump, check for the presence of hydrocarbon vapors. Inhaling these vapors can make you dizzy or unconscious, and if ignited, they can explode and cause serious injury or death. Containment sumps are designed to trap hazardous liquid spills and prevent environmental contamination, so they can accumulate dangerous amounts of hydrocarbon vapors. Check the atmosphere in the sump regularly while you are working in it. If vapors reach unsafe levels, exit the sump and ventilate it with fresh air before you resume working. Always have another person standing by for assistance. WARNING: Follow all federal, state, and local laws governing the installation of this product and its associated systems. When no other regulations apply, follow NFPA codes 30A and 70 from the National Fire Protection Association. Failure to follow these codes could result in severe injury, death, serious property damage, and/or environmental contamination. Do not smoke while working on or near this equipment, and use only non-sparking tools. WARNING: The piping and storage tank must be installed using standard industry practices, including, but not limited to: Recommended Practices for Installation of Underground Storage Systems, The Petroleum Equipment Institute, PEI/RP100 (latest edition). Recommended Practices for Installation of Aboveground Storage Systems, The Petroleum Equipment Institute, PEI/RP200 (latest edition). Recommended Practices for the Storage and Dispensing of Diesel Exhaust Fluid (DEF), The Petroleum Equipment Institute, PEI/RP1100 (latest edition). WARNING: Always secure the work area from moving vehicles. The equipment in this manual is usually mounted underground, so reduced visibility puts service personnel working on it in danger from moving vehicles that enter the work area. To help prevent this safety hazard, secure the area by using a service truck (or some other vehicle) to block access to the work area. WARNING: Make sure you check the installation location for potential ignition sources such as radio waves, ionizing radiation, and ultrasound sonic waves. If you identify any potential ignition sources, you must make sure safety measure are implemented. 2

Questions and concerns In case of emergency, follow the procedures established by your facility. If you have questions or concerns about safety or need assistance, use the information below to contact Franklin Fueling Systems: Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA Technical Support: 1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 France: +33 (0) 1.69.21.41.41 China: +86.10.8565.4566 3

4 Intentionally Blank

Installing DEF Pumping Accessories When you install DEF Pumping Accessories, please keep the following in mind: Disconnect power to the DEF Pump Assembly at the electrical supply box prior to any service. Tag and lock out electrical circuit breakers so they are not turned on accidentally. NOTE: Wiring for single phase units can include run/start capacitor. Make sure the capacitor is safely discharged before disconnecting supply wiring. Apply only DEF compatible thread sealant to all pipe thread connections. Pipe thread connections should be tightened to the following specifications: Pipe Thread Size Minimum Torque Required Tightening Reference ½" NPT 30 ft-lbs 1.5-3.0 turns past hand tight 1½" NPT 100 ft-lbs 1.0-2.5 turns past hand tight 2" NPT 150 ft-lbs 1.0-2.5 turns past hand tight Care should be taken when extracting and installing the DEF Pump Assembly to prevent component damage, including but not limited to the Power Cable of the DEF-PMA. Never lift or suspend the DEF Pump Assembly by the DEF-PMA Power Cable. ½ Bypass Relief Valve must be installed with the outlet pointed away from DEF-PMA Power Cable. Discharging the Bypass Relief Valve at the Power Cable could damage the jacket and the wiring inside. 1½ or 2 Non-Return Check Valve must be installed with flow direction arrow orientation from the DEF-PMA upward towards the top of the DEF Pump Assembly. If the Non-Return Check Valve orientation is not correct, the DEF Pump Assembly will not produce any flow. Do not over-tighten product piping into 2 NPT Discharge Outlet of DEF-PMA or irreparable damage could occur. Verify that the length of the DEF Pump Assembly will not touch the bottom of the tank. DEF- PMA will typically be suspended about 3 (76mm) off the bottom of the storage tank. Do not start DEF-PMA unless it has been completely submerged in fluid. Running the DEF- PMA without product to properly cooling the unit can cause irreparable damage. 5

Typical DEF-PMA installation Pressure Gauge Connection To Power Supply To DEF Filling Point(s) Cable Grip (Included in DEF-PMA Install kit) Cable outside diameter 0.31-0.33" (8-9mm) Pump Access Diameter 6" (152mm) Minimum Recommended Non-Return Check Valve Cracking Pressure 3 PSI (0.2 bar) Maximum Bypass Relief Valve Cracking Pressure 30-40 PSI (2.1-2.8 bar) 4 gpm minimum flow Discharge Outlet DEF-PMA 5.08" (129mm) Outside Diameter 60 Hz: 18.7" (474mm) 50 Hz: 19.8" (504mm) Bottom Clearance Typical 3" (76mm) Not to Scale 6

60 Hertz variable-length DEF-STP replacement kits 1 2 3 4 ITEM MODEL DESCRIPTION 1 N/A Variable-length column pipe assembly (only available as part of complete DEF-STP Kits) 2 403463901 Check valve kit (includes 1½" NPT nonreturn check valve and 1½" NPT x 4" long nipple on inlet) 3 403461901 Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 1½" NPT bushing in 1½" NPT tee) 4 403454901 Pump motor assembly connection kit (includes 2" NPT male inlet x 1½" NPT male outlet EZ FIT connection) 5 403383903 Single-phase Pump Motor Assembly (DEF-PMA150A) 6 403383933 Three-phase Pump Motor Assembly (DEF-PMA150D) Note: Variable Length Column Pipe (item #1) reduces from 2 NPT at the top to 1 ½ NPT at the bottom connection to the Check Valve Kit. 5 or 6 Accessories and repair parts MODEL DESCRIPTION 400170936 Capacitor, 25 uf/370 V (for use with DEF-PMA150A) 400818921 Single-phase 208-240 volt pump control with 120 volt coil 401220903 Three-phase 208-240 volt pump control box with overload protection and 120 volt coil 403408931 1½" NPT non-return check valve (part of item #2, valve only) 403409931 ½" NPT bypass relief valve (part of item #3, valve only) 403468901 DEF-PMA hardware pack (part of item #5 or #6, includes cable grip, cable ties, and documentation) 7

50 Hertz variable-length DEF-STP replacement kits 1 2 3 4 ITEM MODEL DESCRIPTION 1 N/A Variable-length column pipe assembly (only available as part of complete DEF-STP kits) 2 403463901 Check valve kit (includes 1½" NPT nonreturn check valve and 1½" NPT x 4" long nipple on inlet) 3 403461901 Bypass kit (includes ½" NPT bypass relief valve, ½" NPT x 1½" NPT bushing in 1½" NPT tee) 4 403454901 Pump motor assembly connection kit (includes 2" NPT male inlet x 1½" NPT male outlet EZ FIT connection) 5 403383953 Single-phase Pump Motor Assembly (DEF-PMA150B) 6 403383963 Three-phase Pump Motor Assembly (DEF-PMA150C) NOTE: Variable Length Column Pipe (item #1) reduces from 2 NPT at the top to 1 ½ NPT at the bottom connection to the Check Valve Kit. 5 or 6 Accessories and repair parts MODEL DESCRIPTION 400170937 Capacitor, 30 uf/440 V (for use with DEF-PMA150B) 400818922 Single-phase 200-250 volt pump control with 240 volt coil 401220966 Three-phase 380-415 volt pump control box with overload protection and 240 volt coil 403459901 2" NPT female x 2" BSP male thread adapter (part of item #1, adapter only) 403408931 1½" NPT non-return check valve (part of item #2, valve only) 403409931 ½" NPT bypass relief valve (part of item #3, valve only) 403468901 DEF-PMA hardware pack (part of item #5 or #6, includes cable grip, cable ties, and documentation) 8

60 Hertz fixed-length DEF submersible turbine pump kits 1 2 3 4 ITEM MODEL DESCRIPTION 1 N/A Fixed-length column pipe, 2 NPT (locally supplied) 2 403464901 Check valve kit (includes 2 NPT non-return check valve and 2 NPT x 4 long nipple on inlet) 3 403462901 Bypass kit (includes ½ NPT bypass relief valve, ½ NPT x 2 NPT bushing in 2 NPT tee) 4 403456901 Pump motor assembly connection kit (includes 2 NPT male inlet x 2 NPT male outlet EZ FIT connection) 5 403383903 60 Hz, single-phase pump motor assembly (DEF-PMA150A) 6 403383933 60 Hz, three-phase pump motor assembly (DEF-PMA150D) Accessories and repair parts 5 or 6 MODEL DESCRIPTION 400170936 Capacitor, 25 uf/370 V (for use with DEF-PMA150A) 400818921 Single-phase 208-240 volt pump control with 120 volt coil 401220903 Three-phase 208-240 volt pump control box with overload protection and 120 volt coil 403408932 2 NPT non-return check valve (part of component #2, valve only) 403409931 ½ NPT bypass relief valve (part of component #3, valve only) 403468901 DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation) 9

50 Hertz fixed-length DEF submersible turbine pump kits 1 2 3 4 5 or 6 ITEM MODEL DESCRIPTION 1 N/A Fixed-length column pipe, 2 NPT (locally supplied) 2 403464901 Check valve kit (includes 2 NPT nonreturn check valve and 2 NPT x 4 long nipple on inlet) 3 403462901 Bypass kit (includes ½ NPT bypass relief valve, ½ NPT x 2 NPT bushing in 2 NPT tee) 4 403456901 Pump motor assembly connection kit (includes 2 NPT male inlet x 2 NPT male outlet EZ FIT connection) 5 403383903 60 Hz, single-phase pump motor assembly (DEF-PMA150A) 6 403383933 60 Hz, three-phase pump motor assembly (DEF-PMA150D) Accessories and repair parts MODEL DESCRIPTION 400170936 Capacitor, 25 uf/370 V (for use with DEF-PMA150A) 400818921 Single-phase 208-240 volt pump control with 120 volt coil 401220903 Three-phase 208-240 volt pump control box with overload protection and 120 volt coil 403408932 2 NPT non-return check valve (part of component #2, valve only) 403409931 ½ NPT bypass relief valve (part of component #3, valve only) 403468901 DEF-PMA hardware pack (part of components #5 or #6, includes cable grip, cable ties, and documentation) 10

Intentionally Blank

A Franklin Fueling Systems Brand 403414001 r3