VersaFlow Vortex 100 Vortex Flow Meter Specifications

Similar documents
VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Technical Datasheet. Specification. The all-in-one solution. Highlights. Industries.

OPTISWIRL 4070 Technical Datasheet

OPTISWIRL 4070 Technical Datasheet

SITRANS FX300 4/289. System Overview. Overview

OPTISWIRL 4200 Technical Datasheet

SITRANS F X SITRANS FX300 3/355

OPTISWIRL 4200 Technical Datasheet

Flow Measurement SITRANS F X SITRANS FX300 4/365

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

OPTIMASS 3000 Technical Datasheet

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

VersaFlow Coriolis 100 Mass Flow Sensor Specifications

OPTIMASS 2000 Technical Datasheet

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Armstrong In-Line and Insertion Vortex Flow Meters

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

LCMass Series Mass Flow Sensor

F-2500 SERIES VORTEX METER

STEEMCO Flowmeter for Steam

VLM20 In-line Vortex Flowmeter

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

STEEMCO-MAS Flowmeter for Steam

VIM20 Vortex Insertion Flowmeter

F-2700 SERIES INSERTION VORTEX FLOW METER

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

F-2700 SERIES INSERTION VORTEX FLOW METER

BATCHFLUX 5500 C Technical Datasheet

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

ORIMAS Mass Flowmeter

Measurement Products Measurement made easy. Swirl flowmeters FS4000 Simply fitting your purpose Application guide

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

SITRANS F C. Flow sensor MC2 4/193. Overview

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

SITRANS F flowmeters SITRANS F C

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

The readings you need, right where you need them. AX Series Vortex Meters

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

F-1500 SERIES INSERTION TURBINE FLOW METER

Magnetic-inductive flow meter for hazardous areas

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

F-2600 SERIES INLINE VORTEX FLOW METER

Options guide. Electromagnetic flowmeters. M9xx

VORTEX IN-LINE FLOW METERS

Vortex In Line Flow Meter

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

OPTIFLUX 6000 Technical Datasheet

Vortex Flow Meter Model DVH

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

Flap-Type Flow Meter Prall

Turbine flowmeters Series TM

Vortex Flowmeter Model DVE

Micro Motion F-Series Coriolis Flow and Density Meters

SITRANS FC. Flowmeter SITRANS FC410

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Vortex In Line Flow Meter

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

VIM20 Vortex Insertion Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

SITRANS F flowmeters SITRANS F C MASSFLO MASS MC1. 4/146 Siemens FI Overview

Flow Measurement SITRANS F C

Metal tube variable area flowmeter for gases, liquids and steam

UFM 800 W, C and UFM 800 W Hot Tapping. Ultrasonic flowmeters. for water and wastewater

ISTEC MAGNETIC METERS

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Rosemount 8800D Series Vortex Flowmeter

VIM20 Vortex Insertion Flowmeter

Food & beverage. Oil & gas. Water & waste water

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases. Drawing 1

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Rosemount 8800D Series Vortex Flowmeter

Model FVP General Specification. Flanged Vortex Plate. Product Features

Flow Measurement SITRANS F C

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Magnetic Inductive Flowmeter EP / UMF2 (B)

Low Profile Insertion Vortex

Level Measurement Point level measurement - RF Capacitance switches

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Flow Measurement SITRANS F C

Hot Tap Insertion Vortex

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Rosemount 8800D Series Vortex Flowmeter

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Flow Measurement SITRANS F C

Volumeter. RMG Meßtechnik GmbH. Publication No E

Vortex Eggs Delta Flowmeter

Coriolis Mass Flowmeter for low flow measurements

Transmitting Transducer. Gas/Air Velocity Range:

SITRANS F M flow sensors 711/A and 711/911E

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Transcription:

VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated pressure and temperature compensation in 2- wire technology. The VERSAFLOW Vortex Flow Meter provides reliable measurement of operating, standard volumetric and mass flow of conductive and non-conductive liquids, gases and vapors, even with fluctuating pressures and temperatures. Highlights 2-wire device with integrated pressure and temperature compensation Non-wearing, fully welded stainless steel construction with high corrosion, pressure and temperature resistance Optimal process reliability thanks to Intelligent Signal Processing (ISP) - stable readings, free of external perturbations Ready to use immediately thanks to plug & play Maintenance-free sensor design PACTware available at no extra cost Pressure and temperature can be called up via HART Optional Remote electronics for easier access to local programming and display Figure 1 VersaFlow Vortex Flow Meter Applications Vapor and saturated steam measurement Industries Chemical Oil & Gas Power plants Steam boiler monitoring Monitoring of compressor output Measurement of consumption in compressed air systems Iron, Steel and Metal Measurement of consumption of industrial gases Paper and Pulp SIP and CIP processes in the food, beverage and Water pharmaceutical industries Automotive Measurement of conductive and non-conductive liquids

VersaFlow Vortex 100 Vortex Flow Meter 2 Options and Variants 1. The universal device with temperature compensation for saturated steam integrated as standard The VERSAFLOW as a compact flowmeter in a flange version is suitable for universal use in measuring liquids, gases and vapors. The temperature compensation for saturated steam is integrated as standard, thus enabling direct compensation of the density; the mass and energy can also be measured. Here ISP (Intelligent Signal Processing) provides stable measurement results free of external perturbations. 2. The easy to install sandwich version with optimised centering rings The VERSAFLOW as a compact flowmeter in a sandwich version is suitable for universal use in the measurement of liquids, gases and vapors. The temperature compensation for saturated steam is integrated as standard. The flowmeter is provided with additional optimised centering rings. The VERSAFLOW can be aligned centrically by turning the centering rings, eliminating any offset between the VERSAFLOW and the pipeline.

VersaFlow Vortex 100 Vortex Flow Meter 3 3. The only 2-wire device with integrated pressure and temperature compensation The VERSAFLOW as a flange or sandwich flowmeter is optionally available with integrated pressure and temperature compensation for gases, wet gases, gas mixtures or vapors. The advantages of this unique design couldn't be clearer: No additional cost-intensive installation of pressure and temperature sensors No additional cabling work No faulty measurement results, because pressure, temperature and volume flow can be read at a single point Direct measurement of mass and/or energy 4. The highest process availability thanks to optional shut-off valve As an option, HONEYWELL can supply the VERSAFLOW with a shut-off valve to allow the pressure sensor to be exchanged without interrupting the process. What is more, the pressure sensor can be shut off for the purpose of pressure or leak testing of the pipeline. Using the built-in two-way valve, the pressure sensor can also be calibrated and tested at a later time.

VersaFlow Vortex 100 Vortex Flow Meter 4 5. Dual measurement for twofold reliability The VERSAFLOW is optionally available as a dual version. This is a genuine redundant system with two independent sensors and two converters. This provides twofold functional reliability and availability of the measurement. This variant is optimally suited for measurements in multiproduct pipelines. In such pipelines, two different products are moved through one after the other. Here one converter can be programmed for one product, and the other converter for the other product. 6. Remote electronics option allows easier access to the local programming and display Both the sandwich and the flanged versions of the VersaFlow Vortex neter are available with compact or remote electronics. The option of remote electronics does not limit the choice of integral pressure sensing or the ability to select the dual measurement option. The remote converter can be mounted up to 30m from the sensor.

VersaFlow Vortex 100 Vortex Flow Meter 5 PACTware Simple and Intuitive PACTware diagnosis The VERSAFLOW is PACTware-ready. Each device is supplied ex factory with the appropriate DTM (Device Type Manager). A DTM is a device driver containing a user interface optimised for each device, and which makes the device functionality available independently of the field bus protocol. A graphical user interface enables operation and configuration of the meter. Simple, program-based setup of devices is thus possible from the control room, even without a display or keyboard. The best possible operator control concepts have been implemented, optimised for the user's requirements. PACTware reading display Features: Displays measured values Records measured information during operation Shows status of device Stepwise setup Displays summary of setup selection for final checking PACTware online parameter configuration

VersaFlow Vortex 100 Vortex Flow Meter 6 Technical Data Measuring System Application range Operating method / measuring principle Measured value Primary measured value: Secondary measured value: Signal Converter Versions Measuring Sensor Standard Flow measurement of liquids, gases and vapors Karman vortex street Number of separated vortices Operating and standard volumetric flow, mass flow - Compact (Option: Ex version) - Remote to 30m (Option: EX version) Basic device in flange version (with integrated temperature measurement) Basic device in sandwich version (with integrated temperature measurement) Optional Basic device with additional pressure measurement Basic device with additional pressure measurement and shutoff valve for pressure sensor Dual measuring device in both flange and sandwich version (redundant measurement) Dual measuring device in sandwich with additional pressure measurement Display and user interface Local display Operating and display languages 2 lines, 10 characters per line German, English, French Measuring Accuracy Reference condition Water at 20 C Air at 20 C and 1.013 bar abs. Accuracy Based on volume Liquids ± 0.75% of measured value (Re 20000) ± 2% of measured value (10000< Re < 20000) Gases and steams ±1.0% of measured value (< Re < 20000) Repeatability Long-term Stability ±2.0% of measured value (10000< Re < 20000) Pressure temperature compensation ±1.5% of measured value (Re 20000); ±2.5% of measured value (10000 < Re < 20000) ±0.1% of measured value ± 0.01% of measured value

VersaFlow Vortex 100 Vortex Flow Meter 7 Operating Conditions Temperature Product Ambient Pressure Product Ambient Chemical properties -40...+240 C / -40 +465 F Non Ex : -40...+85 C / -40 +185 F Ex: -40...+60 C / -40 +140 F Max. 100 bar / 1450psi; information on higher pressures on request. Atmosphere Density Viscosity Taken into consideration when sizing < 10 cp Reynolds' number 10000...2300000 Recommended flow velocities Liquids Gases and steams Other conditions Protection category IP 66/67 0.3 7m/s / 0.98 23ft/s (optional up to 10m/s / 32.8ft/s taking cavitation into account) 2.0 80 m/s / 6.6 262.5 ft/s DN15: 3.0 45m/s / 9.8 148ft/s; DN25: 2.0 70m/s / For detailed information, see chapter Flow tables Installation Conditions Inlet run Outlet run: Dimensions and weights 20 x DN (without disturbing flow, after pipe narrowing, after a single 90 bend) 30 x DN (after a double bend 2x90 ) 40 x DN (after a double three-dimensional bend 2x90 ) 50 x DN (after control valves) 2 DN before flow straightener; 8 DN after flow straightener (specified values apply only to original 20 DN inlet run) 5 x DN For detailed information refer to chapter "Dimensions and weights". Materials Measuring sensor and process connections Converter housing Pressure sensor gasket Measuring tube gasket Standard 1.4404/316 L. Option: Hastelloy C-22 on request. Die-cast Aluminium Standard: FPM Option: FFKM Standard 1.4435/316L Option: Hastelloy C-276 Selection depends on measuring sensor material/medium.

VersaFlow Vortex 100 Vortex Flow Meter 8 Process connections Flange version DIN EN 1092-1 ASME B16.5 JIS B 2220 DN15...300 in PN16 100 ½...12" in 150 600lbs DN15...300 in JIS 10 20K For detailed information on combination flange/pressure rating, refer to chapter "Dimensions and weights". Sandwich version DIN ASME JIS DN15...100 in PN100 (higher pressures on request) ½...4" in 600lbs (higher pressures on request) DN15...100 in 10 20K (higher pressures on request) Electrical connections Power supply Current Output Description of the used abbreviations Measuring range Non-Ex: 14 VDC...36 VDC Ex: 14 VDC...30 VDC U ext = external voltage; R L = load + resistance 4...20 ma (max. 20.8 ma) + HART protocol Over Range 20.8 ma+/- 1 % (105 % +/- 1%) Load Minimum 0 ; maximum RL = ((U ext - 14 VDC) / 22 ma) Error signal Acc. To NAMUR NE43 Upper value 21.0 ma Lower value 3.6 ma (not with HART protocol) Pulse output Pulse rate Non-Ex: 24 VDC as NAMUR or open < 1 ma, maximum 36 V closed 100 ma, U < 2 V Power supply Ex: 24 VDC as NAMUR, or open < 1 ma, maximum 30 V, closed 100 ma, U < 2 V HART Device revision 1 Physical Layer HART protocol via current output FSK Device category System requirements Multidrop operation Transmitter, galvanically isolated Load min. 250 4 ma Approvals and certifications ATEX EEX Zone 1 Ex II 2G EEx d ia [ia] IIC T6 EEX Zone 2 Ex II 3G EEx na T4 IECEx FM NEPSI Ex d ia [ia] IIC T6 Gb Class I, Div. 1 +FMc Ex d ia [ia] IIC T6 Gb

VersaFlow Vortex 100 Vortex Flow Meter 9 Flow Table Measuring Range Limits DN to EN 1092-1 Size Qmin Qmax Qmin Qmax DN to ASME B16.5 EN 1092-1 [m3/h] EN 1092-1 [m3/h] ASME B16.5[m3/h] ASME B16.5[m3/h] Water 15 1/2 0.45 5.,07 0.44 4.94 25 1 0.81 11.40 0.81 11.40 40 1 1/2 2.04 28.58 2.04 28.58 50 2 3.53 49.48 3.53 49.48 80 3 7.74 108.37 7.74 108.37 100 4 13.30 186.22 13.30 186.21 150 6 30.13 421.86 30.13 421.86 200 8 52.66 737.18 52.66 737.18 250 10 81.43 1140.02 81.43 1140.02 300 12 114.83 1607.61 114.83 1607.61 Values based on water at 20 C Air 15 1/2 6.72 57.91 6.72 56.46 25 1 10.20 130.29 10.20 130.29 40 1 1/2 25.35 326.63 25.35 326.63 50 2 43.89 565.49 43.89 565.49 80 3 96.14 1238.64 96.14 1238.60 100 4 165.14 2128.27 165.19 2128.27 150 6 374.23 4821.60 374.23 4821.60 200 8 653.95 8425.53 633.95 8425.50 250 10 977.16 13028.81 977.16 13028.14 300 12 1377.95 18372.66 1377.95 18372.66 Values based on air at 20 C and 1.013 bar abs Flow rate limits Product Nominal diameters Minimum flow rates Maximum flow rates to EN to ASME [m/s] [m/s] Liquids DN15...DN300 DN ½"...DN12" 0.5 x ( 998 / ) 0.5 1 7 x (998 / ) 0.47 1 Gas, vapor DN15...DN300 DN ½"...DN12" 6 x ( 1.29 / ) 0.5 2 7 x (998 / ) 0.47 2 1 Minimum flow rates 0.4m/s - maximum flow rates 10m/s 2 Minimum flow rates 2m/s - maximum flow rates 80m/s = Operating density [kg/m 3 ]

VersaFlow Vortex 100 Vortex Flow Meter 10 Measuring Range Saturated Steam: 1-7 bar Pressure: bar 1 3.5 5.2 7 Density: kg/m 3 1.1350 2.4258 3.2765 4.1673 Temperature: 0 C 121 148 160 171 Flow: kg/hr min max min max min max min max DN to EN 1092-1 DN to ASME B16.5 15 0.5 5.9 37.0 7.5 76.1 8.7 104.1 9.8 132.4 25 1 11.8 129.4 17.3 276.5 20.1 373.5 22.7 475.1 40 1.5 29.6 370.7 43.4 792.3 50.4 1070.2 56.8 1361.2 50 2 51.3 641.8 75.0 1371.7 87.2 1852.8 98.3 2356.6 80 3 112.4 1405.8 164.3 3004.7 191.0 4058.4 215.4 5161.8 100 4 193.1 2415.5 282.4 5162.8 328.2 6973.3 370.1 8869.2 150 6 439.6 5472.4 639.7 11695.8 743.5 15798.0 838.4 20093.0 200 8 821.9 10279.0 1201.6 21969.7 1396.5 29675.0 1574.7 37743.0 250 10 1313.9 16433.0 1920.9 35121.4 2232.5 47439.0 2517.7 60337.0 300 12 1908.3 23866.0 2789.8 51010.7 3242.4 68899.0 3656.6 87630.0 Measuring Range Saturated Steam: 10.5-20 bar Pressure: bar 10.5 14 17.5 20 Density: kg/m 3 5.8880 7.6030 9.3170 10.5442 Temperature: 0 C 186 199 209 215 Flow: kg/h min max min max min max min max DN to EN 1092-1 DN to ASME B16.5 15 0.5 12.5 187.0 16.1 241.5 19.7 295.9 22.3 334.9 25 1 26.9 671.3 30.6 857.9 33.9 955.5 36.0 1020.2 40 1.5 67.5 1878.2 76.7 2150.7 84.9 2395.3 90.4 2557.7 50 2 116.9 3251.7 132.8 3723.4 147.0 4147.0 156.4 4428.1 80 3 256.0 7122.4 290.9 8155.8 322.1 9083.7 342.6 9699.3 100 4 439.9 12238.0 499.9 14013.0 553.4 15068.0 588.7 16666.0 150 6 996.6 27725.0 1132.5 31747.0 1253.7 35359.0 1333.7 37756.0 200 8 1872.1 52079.0 2127.3 59634.0 2354.9 66419.0 2505.2 70921.0 250 10 2992.7 83254.0 3400.7 95333.0 3764.6 106180.0 4004.9 113380.0 300 12 4346.5 120920.0 4939.1 138460.0 5467.5 154210.0 5816.5 164660.0

VersaFlow Vortex 100 Vortex Flow Meter 11 Measuring Range Saturated Steam: 15-102 psig Pressure: psig 15 51 75 102 Density: lb/ft 3 0.0709 0.1516 0.2047 0.2604 Temperature: 0 F 249 148 160 171 Flow: lb/hr min max min max min max min max DN to EN 1092-1 DN to ASME B16.5 15 0.5 12.9 81.4 16.5 167.7 19.2 229.3 21.6 291.6 25 1 26.0 285.0 38.1 609.1 44.3 822.8 49.9 1046.4 40 1.5 65.3 816.6 95.5 1745.2 110.9 2357.3 125.1 2998.2 50 2 113.0 1413.7 165.3 3021.5 192.0 4081.1 216.6 5190.7 80 3 247.6 3096.5 362.0 6618.3 420.7 8939.2 474.4 11369.6 100 4 425.4 5320.6 622.0 11372.0 722.8 15359.7 815.2 19535.7 150 6 968.2 12053.9 1409.0 25762.0 1637.6 34797.3 1846.8 44257.7 200 8 1810.4 22641.3 2646.7 48392.0 3076.0 65363.4 3468.5 83134.3 250 10 2894.1 36196.5 4231.1 77361.0 4917.4 104491.1 5545.6 132900.8 300 12 4203.3 52569.0 6145.0 112360.0 7141.8 151759.8 8054.2 193017.4 Measuring Range Saturated Steam: 152-290 psig Pressure: psig 152 203 254 290 Density: lb/ft 3 0.3679 0.4750 0.5821 0.6587 Temperature: 0 F 367 389 408 419 Flow: lb/hr min max min max min max min max DN to EN 1092-1 DN to ASME B16.5 15 0.5 27.5 411.9 35.5 531.9 43.5 651.8 49.2 737.7 25 1 59.3 1478.5 67.4 1889.6 74.6 2104.6 79.4 2247.1 40 1.5 148.7 4137.1 169.0 4737.3 187.1 5276.0 199.0 5633.7 50 2 257.5 7162.4 292.6 8201.4 323.9 9134.4 344.5 9753.5 80 3 563.9 15688.3 640.8 17964.6 709.4 20008.1 754.7 21364.1 100 4 969.0 26956.3 1101.1 30866.1 1218.9 33189.4 1296.7 36709.2 150 6 2195.2 61069.1 2494.5 69928.3 2761.5 77883.2 2937.7 83162.9 200 8 4123.6 114713.0 4685.7 131354.2 5187.0 146297.2 5518.1 156213.5 250 10 6591.8 183381.4 7490.5 209987.4 8292.1 233876.4 8821.4 249735.4 300 12 9573.8 266347.3 10879.1 304982.1 12042.9 339669.3 12811.7 362686.9

VersaFlow Vortex 100 Vortex Flow Meter 12 Dimensions and Weights (metric) Flange version EN 1092-1 Size Pressure rating Dimensions [mm] DN PN d D L H I Weight [kg] With pressure sensor Without pressure sensor 15 40 17.3 95 200 265 144 6.1 5.5 15 100 17.3 105 200 265 144 7.1 6.5 25 40 28.5 115 200 265 144 7.9 7.3 25 100 28.5 140 200 265 144 9.9 9.3 40 40 43.1 150 200 270 144 10.8 10.2 40 100 42.5 170 200 270 144 14.8 14.2 50 16 54.5 165 200 275 144 12.7 12.1 50 40 54.5 165 200 275 144 12.9 12.3 50 63 54.5 180 200 275 144 16.9 16.3 50 100 53.9 195 200 275 144 18.4 17.8 80 16 82.5 200 200 290 154 17.4 16.8 80 40 82.5 200 200 290 154 19.4 18.8 80 63 81.7 215 200 290 154 23.4 22.8 80 100 80.9 230 200 290 154 27.4 26.8 100 16 107.1 220 250 310 164 22 21.4 100 40 107.1 235 250 310 164 25 24.4 100 63 106.3 250 250 310 164 30 29.4 100 100 104.3 265 250 310 164 36 35.4 150 16 159.3 285 300 325 174 35.8 35.2 150 40 159.3 300 300 325 174 41.8 41.2 150 63 157.1 345 300 325 174 59.8 59.2 150 100 154.1 355 300 325 174 67.8 67.2 200 10 206.5 340 300 350 194 38.4 37.8 200 16 206.5 340 300 350 194 38.4 37.8 200 25 206.5 360 300 350 194 47.4 46.8 200 40 206.5 375 300 350 194 55.4 54.8 250 10 260.4 395 380 370 224 58.0 57.4 250 16 260.4 405 380 370 224 59.0 58.4 250 25 258.8 425 380 370 224 75.0 74.4 250 40 258.8 450 380 370 224 93.0 92.4 300 10 309.7 445 450 395 244 76.3 75.7 300 16 309.7 460 450 395 244 82.8 82.2 300 25 307.9 485 450 395 244 99.3 98.7 300 40 307.9 515 450 395 244 128.1 127.5

VersaFlow Vortex 100 Vortex Flow Meter 13 Flange Version ASME B16.5 Size Pressure rating Dimensions [mm] DN PN d D L H I Weight [kg] With pressure sensor Without pressure sensor 1/2 150 15.8 90 200 265 144 5.1 4.5 1/2 300 15.8 95 200 265 144 5.5 4.9 1/2 600 13.9 95 200 265 144 5.7 5.1 1 150 26.6 110 200 265 144 6.8 6.2 1 300 26.6 125 200 265 144 7.8 7.2 1 600 24.3 125 200 265 144 8.1 7.5 1 1/2 150 40.9 125 200 270 144 8.9 8.3 1 1/2 300 40.9 155 200 270 144 11 10.4 1 1/2 600 38.1 155 200 270 144 12 11.4 2 150 52.6 150 200 275 144 11.6 11 2 300 52.6 165 200 275 144 13 12.4 2 600 49.3 165 200 275 144 14.5 13.9 3 150 78 190 200 290 154 20.4 19.8 3 300 78 210 200 290 154 23.4 22.8 3 600 73.7 210 200 290 154 24.4 23.8 4 150 102.4 230 250 310 164 24 23.4 4 300 102.4 255 250 310 164 32 31.4 4 600 97.2 275 250 310 164 41 40.4 6 150 154.2 280 300 325 174 36.8 36.2 6 300 154.2 320 300 325 174 51.8 51.2 6 600 146.3 355 300 325 174 76.8 46.2 8 150 202.7 345 300 350 194 50.6 50.0 8 300 202.7 380 300 350 194 75.4 74.8 10 150 254.5 405 380 370 224 75.0 74.4 10 300 254.5 455 380 370 224 107.0 106.4 12 150 304.8 485 450 395 244 106.9 106.3 12 300 304.8 520 450 395 244 151.9 151.3

VersaFlow Vortex 100 Vortex Flow Meter 14 Dimensions and Weights (Imperial) Flange Version ASME B16.5 Size Pressure rating Dimensions [inches] DN PN d D L H I Weight [lb] With pressure sensor Without pressure sensor 1/2 150 0.62 3.54 7.87 10.43 5.67 11.24 9.92 1/2 300 0.62 3.74 7.87 10.43 5.67 12.13 10.8 1/2 600 0.54 3.74 7.87 10.43 5.67 12.57 11.24 1 150 1.05 4.33 7.87 10.43 5.67 14.99 13.67 1 300 1.05 4.92 7.87 10.43 5.67 17.2 15.87 1 600 0.96 4.92 7.87 10.43 5.67 17.86 16.53 1 1/2 150 1.61 4.92 7.87 10.63 5.67 19.62 18.3 1 1/2 300 1.61 6.1 7.87 10.63 5.67 24.25 22.93 1 1/2 600 1.5 6.1 7.87 10.63 5.67 26.46 25.13 2 150 2.07 5.91 7.87 10.83 5.67 25.57 24.25 2 300 2.07 6.5 7.87 10.83 5.67 28.66 27.34 2 600 1.94 6.5 7.87 10.83 5.67 31.97 30.64 3 150 3.07 7.48 7.87 11.42 6.06 44.97 43.65 3 300 3.07 8.27 7.87 11.42 6.06 51.59 50.26 3 600 2.9 8.27 7.87 11.42 6.06 52.79 52.47 4 150 4.03 9.06 9.84 12.21 6.46 52.91 51.59 4 300 4.03 10.04 9.84 12.21 6.46 70.55 69.22 4 600 3.83 10.83 9.84 12.21 6.46 90.39 89.07 6 150 6.07 11.02 11.81 12.8 6.85 81.13 79.81 6 300 6.07 12.6 11.81 12.8 6.85 114.2 112.88 6 600 5.76 13.98 11.81 12.8 6.85 169.31 101.85 8 150 7.98 13.58 11.81 13.78 7.64 146.39 145.65 8 300 7.98 14.96 11.81 13.78 7.64 190.32 189.65 8 600 7.63 16.54 11.81 13.78 7.64 331.57 330.25 10 150 10.02 15.51 14.96 14.57 8.82 197.09 195.77 10 300 10.02 17.91 14.96 14.57 8.82 252.21 239.86 10 600 9.56 20.08 14.96 14.57 8.82 419.76 418.43 12 150 12 19.09 17.72 15.55 9.61 318.34 317.02 12 300 12 20.47 17.72 15.55 9.61 415.35 414.02 12 600 11.37 22.05 17.72 15.55 9.61 543.21 541.89

VersaFlow Vortex 100 Vortex Flow Meter 15 Dimensions and Weights (metric) Sandwich Version EN Size Pressure rating Dimensions [mm] DN PN d D L H I With pressure sensor Weight [kg] Without pressure sensor 15 100 16 45 65 265 144 4.1 3.5 25 100 24 65 65 265 144 4.9 4.3 40 100 38 82 65 270 144 5.5 4.9 50 100 50 102 65 275 144 6.6 6 80 100 74 135 65 290 155 8.8 8.2 100 100 97 158 65 310 164 10.1 9.5 Option: Version with two transmitters

VersaFlow Vortex 100 Vortex Flow Meter 16 Dimensions and Weights (Imperial) Sandwich Version ASME Size Pressure rating Dimensions [inches] DN PN d D L H I With pressure sensor Weight [lb] Without pressure sensor 1/2 150 0.63 1.77 2.56 10.43 5.67 9.04 7.72 1/2 300 0.63 1.77 2.56 10.43 5.67 9.04 7.72 1/2 600 0.55 1.77 2.56 10.43 5.67 9.04 7.72 1 150 0.94 2.56 2.56 10.43 5.67 10.8 9.48 1 300 0.94 2.56 2.56 10.43 5.67 10.8 9.48 1 600 0.94 2.56 2.56 10.43 5.67 10.8 9.48 1 1/2 150 1.5 3.23 2.56 10.63 5.67 12.13 10.8 1 1/2 300 1.5 3.23 2.56 10.63 5.67 12.13 10.8 1 1/2 600 1.5 3.23 2.56 10.63 5.67 12.13 10.8 2 150 1.97 4.02 2.56 10.83 5.67 14.55 13.23 2 300 1.97 4.02 2.56 10.83 5.67 14.55 13.23 2 600 1.97 4.02 2.56 10.83 5.67 14.55 13.23 3 150 2.91 5.31 2.56 11.42 6.1 19.4 18.08 3 300 2.91 5.31 2.56 11.42 6.1 19.4 18.08 3 600 2.91 5.31 2.56 11.42 6.1 19.4 18.08 4 150 3.82 6.22 2.56 12.21 6.46 22.27 20.94 4 300 3.82 6.22 2.56 12.21 6.46 22.27 20.94 4 600 3.82 6.22 2.56 12.21 6.46 22.27 20.94

VersaFlow Vortex 100 Vortex Flow Meter 17 Dimensions Remote version Dimension a Flanged version Sandwich version DN 15 25 40 50 80 100 150 200 250 300 NPS ½ 1 1 ½ 2 3 4 6 8 10 12 [mm] 248 248 253 258 273 293 308 333 353 378 [ ] 9.77 9.77 9.97 10.2 10.8 11.5 12.1 13.1 13.9 14.9 b c d e f g h j k l m n [mm] 140 106 310 219 140 120 100 115 9 (4x) 60 80 114 [ ] 5.52 4.18 12.2 8.63 5.52 4.73 3.94 4.53 0.36 (4x) 2.36 3.15 5.67 Specifications are subject to change without notice

VersaFlow Vortex Meters Using internal pressure and temperature compensation for improved performance and reduced energy cost The VersaFlow Vortex meter is the only meter of its type on the market that offers integral temperature compensation standard and the option of integral pressure compensation. These features offer improved system accuracy and can significantly reduce energy costs. Virtually all industries rely on steam to generate power, heat facilities or clean process lines. Steam efficiency is measured in two basic areas--how effective is the steam production (boiler efficiency) and how effective is the transport of steam throughout the facility (leakage detection and heat loss). The ability to measure pressure and temperature and calculate heat allows the VersaFlow Vortex meter to monitor the production and transfer of steam. The below diagram illustrates the traditional use of an uncompensated Vortex meter with a separate pressure sensor, temperature sensor and flow computer. Along with increased potential leak points, you have the total installed cost and accuracy issues to contend with. Typical installed cost of a 2 Vortex meter in a system is shown: Vortex Meter $2500 plus 1.5 hour labor @$ 150/hr Temperature Sensor $350 plus 1 hour labor Pressure Sensor $650 plus 1 hour labor Flow Computer to calculate steam flow $1350 plus 1.5 hour labor Total Installed Cost: $5600 VersaFlow Vortex with Integral Temperature, Pressure and Steam Calculation: $4800 plus 1.5 hour labor. Total Installed Cost: $5025 Cost Savings: $575 System accuracy improved from ± 3% to ± 1% Flow Computer Power Supply 55.6 Potential Leak Point Flow 4-20 ma Pulse Output Vortex instrument Pressure Temperature System accuracy at best ± 3%

VersaFlow Vortex 2 Saturated Steam In most saturated steam applications the operating temperature and pressure is a known quantity coming off the boiler. Depending on the insulation, as well as leakage in the pipeline, not to mention boiler efficiency, temperature and pressure will not always remain at the ideal levels expected. Saturated steam has a fixed pressure to temperature relationship. Integral temperature measurement is all that is required. Assuming a constant temperature can lead to errors as shown in the example. 3 meter 5911 Kg/hr Saturated steam with a presumed 350 F temperature Deg F 350 Psia 134 Kg/hr 5911 Error Superheated Steam In superheated steam the pressure and temperature are independent. It is recommended that both are tracked. As shown in the example, as temperature changes, even if pressure remains constant the errors can rapidly increase. 3 meter - 1450 kg/hr Superheated Steam at 350 deg F and 20 psig Temperature Flow Output Error 350 1450 360 1431.5 1.3% 370 1413.1 2.5% 380 1395.3 3.8% 390 1377.9 5.0% 400 1361 6.1% 410 1344.5 7.3% 420 1328.5 8.4% 430 1312.9 9.5% 440 1297.6 10.5% 450 1282.8 11.5% 360 152 6680-13.0% 370 380 390 400 340 330 320 310 173 195 219 246 117 103 89 77 7243 7705 8186 8686 5214 4586 4019 3510-22.5% -30.4% -38.5% -46.9% 11.8% 22.4% 32.0% 40.6% Pressure Flow Output Error 20 1450 22 1536 5.9% 24 1620 11.7% 26 1706 17.7% 28 1792 23.6% 30 1878 29.5% 32 1964 35.4% 34 2050 41.4% 36 2136 47.3% 38 2223 53.3% 40 2309 59.2% 300 67 3054 48.3% A +50 def F change creates a -47% error A -50 deg F change creates a + 48% error An integral temperature sensor and integral steam tables in the VersaFlow Vortex meter maintains the 1% accuracy A 20 deg F change leads to a 2.5% error A 50 deg F change leads to a 6% error A 100 deg F change leads to a 11.5% error VersaFlow Vortex with integral temperature sensor and integral superheated steam tables maintains the 1% accuracy. Likewise if pressure shifts even by a couple of psi, the errors start to compound. A 10% change in pressure creates a 6% meter error A 50% change in pressure creates a 30% error in reading VersaFlow Vortex with integral pressure sensor and integral superheated steam tables maintains the 1% accuracy

monitor gas feed to the boiler. The other is in monitoring the Lbs Steam Lost per Total Cost per Total Cost VersaFlow efficiency of Vortex the steam lines transporting the steam. The major Size of Leak Month Month per Year 3 concern, once the line is designed, is the integrity of the 1/8 Inch 52,500 $262.50 $3,150.00 pipeline and how much steam is being lost to leakage. 3/16 Inch 117,000 $585.00 $7,020.00 ¼ Inch 210,000 $1,050.00 $12,600.00 VersaFlow Vortex is ideal for this task. By placing a vortex 5/16 Inch 325,000 $1,625.00 $19,500.00 meter at the discharge of the boiler and taking advantage of 3/8 Inch 470,000 $2,350.00 $28,200.00 the integral temperature measurement, you can easily 7/16 Inch 637,000 $3,185.00 $38,220.00 measure the steam being generated. If you have a flow meter ½ Inch 835,000 $4,175.00 $50,100.00 on the gas feed line, you can actually monitor boiler efficiency by comparing gas used to the pounds of steam produced (the vortex meter can easily measure in mass flow units because of NOTE: One pound of 100 psi steam contains about 1,200 the temperature compensation). Then by placing another BTUs. vortex meter at a designated spot further downstream of the If the steam is produced at 85% efficiency, the input energy is boiler you can make the measurement again and compare the 1,200 / 85% = 1,411 BTUs per pound. Therefore, 1,000 flow rate of the steam to what is coming off the boiler. Any pounds of steam requires at least 1.4 million BTUs to produce reduction in flow not accounted for by any usage points in it. (1,411 BTUs per pound x 1,000) between is attributable to leakage. 1 MCF of Natural Gas contains 1 million BTUs Cost to produce 1,000 lbs of steam from natural gas = 1.4 x $ As you can see in the table, even a small leak can cost per MCF of Natural Gas thousands of dollars a year, not to mention the additional cost When natural gas costs $7.00 per MCF, 1,000 lbs of steam to manufacture more steam to compensate. A ½ hole can cost costs (1.4 x $7) = $9.80 upwards of $50,000 in a year if left unchecked. (Source: Armstrong International) Another feature that the VersaFlow Vortex meter can provide is the ability to monitor heat loss. By use of the local display or the HART protocol you can track the temperature and see if there is any extraordinary heat loss from where you measured at the boiler. Heat loss means energy costs, so tracking this can be critical as well. Typical Vortex Meter Applications Controlling of steam boiler, superheated and saturated steam measurement Burner consumption measurement Controlling of compressor capacity, consumption measurement in compressed air networks SIP- and CIP-processes in the food, beverage and pharma industries Measuring of industrial gases (natural gas, oxygen, nitrogen, hydrogen, argon, etc.) More Information For more information, visit www.teltherm.co.nz or contact your Teltherm Sales Representative. SO-09-25-ENG July 2009 2009 Honeywell International Inc. Conductive and non conductive liquids < 10 cp (demineralized water, thermo oil, freezing agent, etc.)