Model 8800C Vortex Installation Effects English Rev. CA

Similar documents
Rosemount 8800 Vortex Installation Effects

Technical Data Sheet , Rev HB October Rosemount 8800 Vortex Installation Effects

Technical Data Sheet , Rev HA October Rosemount 8800 Vortex Installation Effects

Rosemount Orifice Series Differential Pressure Flow

Rosemount 285 Annubar Primary Element Series

F-2500 SERIES VORTEX METER

F-2600 SERIES INLINE VORTEX FLOW METER

Air Flow Measurement Technologies

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Fluid Flow Conditioning

Model 1000 Vortex Meter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

flow measurement solutions RIM10 series rotor insertion flowmeters

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

F-2600 SERIES INLINE VORTEX FLOW METER

Fundamental Training. Flow Con t

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Sensing & Inspection Technologies. Benefits.

1495 Orifice Plate 1496 Flange Union 1497 Meter Section Installation & Operation Manual

ONICON Insertion Turbine Flow Meters Single Turbine vs. Dual Turbine Selection Criteria

STEEMCO-MAS Flowmeter for Steam

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

Multivariable Vortex Flow Meter

Vortex Plate. Model VP General Specification. Product Features

Accutrol, LLC Product Sheet. VTS Series. US Patents 6,991,177 & 7,543,759. Digital Airflow Measurement Station

Transmitting Transducer. Gas/Air Velocity Range:

Multivariable Vortex Flow Meter

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Loop Powered Mass Flow Meters. Instruction Manual

Hydro-Flow Model 3100

STEEMCO Flowmeter for Steam

Model FVP General Specification. Flanged Vortex Plate. Product Features

Hydro-Flow Model 2200 Installation and Operation Guide B

ORIMAS Mass Flowmeter

Low Profile Insertion Vortex

SIGNET 7002 Vortex Flow Sensor ENGLISH

Experiment (4): Flow measurement

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

VACOMASS. Technical information VACOMASS square diaphragm control valve

Armstrong In-Line and Insertion Vortex Flow Meters

VORTAB FLOW CONDITIONERS. For Flow Meters, Pumps and Other Flow Profile Critical Equipment

STEALTH INTERNATIONAL INC. DESIGN REPORT #1001 IBC ENERGY DISSIPATING VALVE FLOW TESTING OF 12 VALVE

Model 5000 Vortex Meter

Top Mount Installation for DP Flowmeters in Steam Service

VERIS FLOW MEASUREMENT GROUP

Hot Tap Insertion Vortex

Hydro-Flow Model 2300 Installation and Operation Guide B

Sierra Series 240 and 241 Innova-Mass Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

VorTek Series M22, M23 and M24 Pro-V Vortex Volumetric and Mass Flow Meters. Instruction Manual

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Vortex Flowmeter Model DVE

Instruction Manual Vortex Flow Meter DVH / DVE

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

Demand Based Static Pressure Reset Control for Laboratories

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

QuickStick Repeatability Analysis

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Condensed Version of Operator s Manual For The VL600 Series Flowmeters

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

DVH / DVE. Vortex Flow Meter. Instruction Manual. Page 1 of 102

FUNDAMENTALS OF GAS TURBINE METERS Paul Honchar Sr. Product Manager Sensus 805 Liberty Boulevard DuBois, PA, USA 15801

VorTek Series M22 and M23 Pro-V Multi-Parameter Vortex Mass Flow Meters. Instruction Manual

F-2600 & F-2700 Series Vortex Flow Meter Installation and Operation Guide

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

Rosemount 485 Annubar Flanged Assembly

Liquid Turbine Flowmeter

DIGIFLO ELECTRONIC FLOWMETER

TA-2 RANGE OF THERMAL ANEMOMETERS

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement

EX80 Series EX81 EX82. E X 8 0 S E R I E S E l e c t r o m a g n e t i C F l o w s e n s o r i n s t r u c t i o n s. The Leader in Flow Meter Value.

Vortex Flow Meter Model DVH

240/241 Series Vortex Volumetric and Mass Flow Meters. Instruction Manual

Fundamentals of Turbine Meters. Paul Honchar Sensus Metering Systems

DIGITAL PRESSURE AND FLOW INDICATOR MODEL FPA500

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Vortex In Line Flow Meter

VIM20 Vortex Insertion Flowmeter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

ARCHIVED. EX80 Series. (Includes Dates 6/28/05 to 10/06) EX81 EX82

VIM20 Vortex Insertion Flowmeter

Rosemount 485 Annubar Pak-Lok Assembly

Linear Shaft Motors in Parallel Applications

The readings you need, right where you need them. AX Series Vortex Meters

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

Rosemount 485 Annubar Threaded Flo-Tap Assembly

CB50X & CB50X-DL load cells Influence factors in weighbridge application

VLM20 In-line Vortex Flowmeter

Components of Hydronic Systems

Flow Measurement SITRANS F S Clamp-on

DIGITAL FLOWMETER AND PRESSURE INDICATOR MODEL FPA400

Micro Motion ELITE Mass Flow and Density Meters

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Rosemount 2160 Wireless Vibrating Fork Liquid Level Switch

Signet 2517 Brass Paddlewheel Flow Sensor * *

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Transcription:

Model 8800C Vortex Installation Effects 00816-0100-3250 English Rev. CA

Model 8800C Vortex Installation Effects MODEL 8800C VORTEX INSTALLATION EFFECTS One of the perceived limitations of vortex meters is that they are highly sensitive to installation effects. Since it is true that the conditions in a plant environment may be quite different than the conditions under which the vortex meter is calibrated, some meters may be adversely affected by the installation conditions. The Rosemount Model 8800C Vortex Flowmeter is designed to compensate for or limit the effects encountered in actual installations. In designing the Model 8800C, Rosemount Inc. tested the meter for three separate types of installation effects: process fluid temperature variation, process piping inside diameter, and upstream and downstream disturbances. As a result of this testing, compensation factors are included in the vortex meter software; which allows the output of the vortex meter to be adjusted to compensate for the actual process temperature and process piping being used. Data is presented in this paper to demonstrate the effectiveness of the design in limiting the errors resulting from piping disturbances. For upstream disturbances caused by pipe elbows, contractions, expansions, etc., Rosemount Inc. has conducted extensive research in the flow lab to determine the effect that these have on the meter output. These tests are the basis for the recommended 35D upstream piping diameter. While this is optimal, it is not always possible in the real world of plant design and layout. Therefore, the data presented in this paper outlines the effects of different upstream and downstream piping conditions on the vortex meter. Temperature Effects The vortex meter is a velocity measuring device. As fluid flows past the shedder bar, vortices are shed in direct proportion to the passing velocity. If the temperature of the process is different than the reference calibration temperature, the meter bore diameter will change. This causes the velocity past the shedder bar to change. An increase in the temperature causes an increase in the bore diameter, which causes a slight decrease in the velocity past the shedder bar. The Model 8800C automatically calculates the effect of temperature on the mean K-factor of the meter for whatever process temperature has been input by the user. Pipe ID Effects In a similar manner, the Model 8800C will automatically correct for the user defined inside pipe diameter. From testing done in pipes with different inside diameters, Rosemount Inc. has established that there is a small K-factor shift for changes in process pipe ID. This is because different pipe inside diameters change the inlet velocity profile that the meter sees. These shifts have been programmed into the Model 8800C and are automatically corrected for based on the pipe diameter that is input by the user. Upstream and Downstream Piping Configurations The number of possible upstream and downstream piping configurations is infinite. Therefore, it is not possible to have software automatically calculate a correction factor for changes in upstream piping. Fortunately, in almost all cases, elbows, reducers, etc. cause less than a 0.5% shift in the meter output. In many cases, this small effect is not a large enough shift to cause the reading to be outside of the accuracy specification of the meter. The shifts caused by upstream piping configurations are basically due to the changes in the inlet velocity profile caused by upstream disturbances. For example, as a fluid flows around an elbow, a swirl component is added to the flow. Because the factory calibration is done in what is a fully-developed pipe flow, the swirl component caused by the elbow will cause a shift in the vortex meter output. Given a long enough distance between an elbow and the meter, the viscous forces in the fluid will overcome the inertia of the swirl and cause the velocity profile to become fully-developed. There rarely is sufficient length in actual process piping installations for this to occur. Even though the flow profile may not be fully-developed, testing indicates that the Rosemount vortex meter can be located within 35 pipe diameters of the elbow with minimal effect on the accuracy or repeatability of the meter. In the Rosemount Inc. R&D flow lab, several common pipe configurations have been set up. The Model 8800C has been tested at various lengths downstream of these configurations and the resulting mean K-factor shifts have been determined. These graphs are shown on the following pages. 2

Rosemount Inc. Although the upstream disturbance may cause a shift in the K-factor, the repeatability of the vortex meter is normally not affected. For example, a meter 20 diameters downstream of a double elbow will be as repeatable as a meter in a straight pipe. Testing also indicates that while the K-factor is affected by upstream piping, the linearity of the meter remains within design specifications. In many applications, this means that no adjustment for piping configuration will be necessary even when the minimum recommended installation lengths of upstream and downstream piping cannot be used. However, the user may adjust the meter K-factor directly or use the special units features to make an adjustment to the output of the meter to compensate for these small piping effects. On the following pages are pictures that show examples of the installation configurations that were done in the Rosemount Inc. flow lab. The results of those tests are shown as a series of graphs indicating the shift in the mean K-factor for a vortex meter placed downstream of a flow disturbance. In the graphics, the terms in plane and out-of-plane are used. A butterfly valve and a vortex meter are considered to be in plane when the shaft of the valve and the shedder bar of the vortex meter are aligned (e.g. both the shaft and the shedder bar are vertical.) Referring to the photo of a single elbow installation shown in Figure 1 on page 4, the elbow is considered to be in plane. Similarly, in Figure 4 on page 5, two 90 elbows (which themselves are in a common plane) are shown; their plane is considered to be in plane with the vortex meter. Figure 6 on page 5 contains data from two 90 elbows which do not have a common plane. The plane of the elbows entering and exiting the vortex meter is not aligned with the shedder bar of the vortex meter, therefore this configuration is considered out-of-plane. CORRECTING THE OUTPUT OF THE VORTEX METER The flow disturbance data can be used to correct the output of the vortex meter in the following ways: 1. The K-factor can be adjusted using the Model 275 Installation Effect command. This command will adjust the compensated K-factor to account for the correction. The correction can be entered as a percentage of the K-factor shift. The range of this factor is +1.5% to -1.5%. NOTE The Installation Effect command is available with the Model 275 Dev v3, DD v1, and Model 8800C enhanced software of the vortex flowmeter if this command is not available, please refer to step 2 or step 3. As an example from Figure 2 on page 4, a three-inch vortex meter installed 15 pipe I.D.s downstream from a single elbow, with the shedder bar in plane, the K-factor shift would be +0.3%. To adjust the K-factor to correct for this shift, insert the +0.3% into the Installation Effect command on the Model 275. The compensated K-factor will then show the correction. 2. The K-factor can be adjusted by the percentage shift in the K-factor. Follow the example above to adjust the K-factor to correct for this shift. Since the shift is +0.3%, multiply the reference K-factor as shown on the namplate by 1.003. Then enter this as the new reference K-factor. A typical three-inch meter reference K-factor would be 10.79 p/gal. Using the above example, the new K-factor would be 10.82 p/gal. Likewise, for a butterfly valve (Figure 9) out of plane at 10 pipe diameters, there is a K-factor shift of -0.1%. To adjust the K-factor to correct for the shift, multiply the reference K-factor as shown on the nameplate by 0.999 and enter the new K-factor. 3. Special Units can be configured using the conversion number to reflect the shift in the K-factor. To configure Special units with a Model 275 HART Communicator, change the PV units to special. Follow the single elbow example above (+0.3% shift in K-factor) and multiply the conversion number by 1.003 and enter this new number. A three-inch meter configured 0 to 300 gallons per minute would be configured in special units as Gal/M, with a conversion number of 1.003. 3

Model 8800C Vortex Installation Effects FIGURE 1. Single Elbow in Plane. 8800-02B Single Elbow FIGURE 2. Single Elbow Graph. 8800-8800_05A Expansion FIGURE 3. Expansion Graph. 8800-8800_07A 4

Rosemount Inc. FIGURE 4. Double Elbow in Plane. 8800-05B Double Elbows Same Plane FIGURE 5. Double Elbows Same Plane Graph. 8800-8800_08A Double Elbow Different Planes FIGURE 6. Double Elbows Different Plane Graph. 8800-8800_03A 5

Model 8800C Vortex Installation Effects FIGURE 7. Reducer. 8800-04B Reducer FIGURE 8. Reducer Graph. 8800-8800_04A Butterfly Valve 6 FIGURE 9. Butterfly Graph. 8800-8800_06A

Rosemount Inc. 7

PRINTED Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. HART is a registered trademark of the HART Communication Foundation. Cover Photo: 8800-05B Model 8800C Smart Vortex Flowmeter Installed with a Double Elbow. Rosemount Inc. 8200 Market Boulevard Chanhassen, MN 55317 USA Tel 1-800-999-9307 Fax (612) 949-7001 2000 Rosemount Inc. http://www.rosemount.com IN U.S. A. 00816-0100-3250( Fisher-Rosemount Flow Groeneveldselaan 6-8 3903 AZ Veenendaal The Netherlands Tel 31 (0) 318 549 549 Fax 31 (0) 318 549 559 Tel 0800-966 180 (U.K. only) Fax 0800-966 181 (U.K. only) 00816-0100-3250 Rev. CA 1/00