BEHAVIOUR OF ELECTRIC FUSES IN AUTOMOTIVE SYSTEMS UNDER INTERMITTENT FAULT

Similar documents
Chapter 7: Thermal Study of Transmission Gearbox

Active Systems Design: Hardware-In-the-Loop Simulation

New fem model for thermal analysis of medium voltage fuses

EXPERIMENTAL STUDY OF DYNAMIC THERMAL BEHAVIOUR OF AN 11 KV DISTRIBUTION TRANSFORMER

Performance of DC Motor Supplied From Single Phase AC-DC Rectifier

Master of Engineering

A Simple Approach for Hybrid Transmissions Efficiency

DESIGN & OPTIMIZATION OF EXHAUST MUFFLER & DESIGN VALIDATION

GT-Suite Users Conference

GT-POWER/SIMULINK SIMULATION AS A TOOL TO IMPROVE INDIVIDUAL CYLINDER AFR CONTROL IN A MULTICYLINDER S.I. ENGINE

CFD ANALYSIS ON LOUVERED FIN

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Active Roll Control (ARC): System Design and Hardware-Inthe-Loop

FLUID DYNAMICS TRANSIENT RESPONSE SIMULATION OF A VEHICLE EQUIPPED WITH A TURBOCHARGED DIESEL ENGINE USING GT-POWER

Design of a Low Voltage DC Microgrid Based on Renewable Energy to be Applied in Communities where Grid Connection is not Available

DC Choppers Applications in DC motor Drives and Renewable Energies. Part I- Electric DC Motor Drives

Simulation of a Narrow Gauge Vehicle using SIMPACK, Model Validation using Scaled Prototypes on Roller-Rig

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

A Methodology to Investigate the Dynamic Characteristics of ESP Hydraulic Units - Part II: Hardware-In-the-Loop Tests

Experimental Investigation of Effects of Shock Absorber Mounting Angle on Damping Characterstics

Research in hydraulic brake components and operational factors influencing the hysteresis losses

Thermomechanical Analysis of the Turbo-Compressor Sliding Bearing Mount Units

Semi-Active Suspension for an Automobile

RESPONSE OF A MEDIUM VOLTAGE CURRENT LIMITING FUSE OF SMALL SIZE TESTED AS GENERAL PURPOSE AND FULL- RANGE TYPE.

Development of Rattle Noise Analysis Technology for Column Type Electric Power Steering Systems

Encapsulated Piezo Actuators for Use at High Power Levels and / or within Harsh Environmental Conditions.

Optimization of Three-stage Electromagnetic Coil Launcher

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

National comparison on verification of fuel dispensers

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

The Simulation of Metro Wheel Tread Temperature in Emergency Braking Condition Hong-Guang CUI 1 and Guo HU 2*

Experimental Performance Evaluation of IPM Motor for Electric Vehicle System

/12/$ IEEE. M. Bashir M.Sc student, Student Member, IEEE Ferdowsi University of Mashhad Mashhad, Iran

INTRODUCTION. I.1 - Historical review.

Enhancement of Transient Stability Using Fault Current Limiter and Thyristor Controlled Braking Resistor

Sizing of Ultracapacitors and Batteries for a High Performance Electric Vehicle

Temperature Field in Torque Converter Clutch

Constructive Influences of the Energy Recovery System in the Vehicle Dampers

Ultra-Rapid Fuse Links for the Protection of Semiconductor Rectifiers

AXLE HOUSING AND UNITIZE BEARING PACK SET MODAL CHARACTERISATION

MODELING SUSPENSION DAMPER MODULES USING LS-DYNA

Cooldown Measurements in a Standing Wave Thermoacoustic Refrigerator

Experimental Characterization of Gas Filled Hydraulic Damper Using Ramp Excitation

2W, Low Cost DIP, Dual Output DC/DC Converters

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

Effects of Dilution Flow Balance and Double-wall Liner on NOx Emission in Aircraft Gas Turbine Engine Combustors

Fuses Introductory Information

Prediction of Physical Properties and Cetane Number of Diesel Fuels and the Effect of Aromatic Hydrocarbons on These Entities

Finite Element Analysis on Thermal Effect of the Vehicle Engine

Application of Simulation-X R based Simulation Technique to Notch Shape Optimization for a Variable Swash Plate Type Piston Pump

Analysis of Torsional Vibration in Elliptical Gears

FUSES FOR SEMICONDUCTORS

Computational Investigation of Normal and Hybrid Cooling Fins of Internal Combustion Engine

Simulation of Voltage Stability Analysis in Induction Machine

EXPERIMENTAL STUDY ON DIESEL ENGINE FITTED WITH VISCO FAN DRIVE

Turbostroje 2015 Návrh spojení vysokotlaké a nízkotlaké turbíny. Turbomachinery 2015, Design of HP and LP turbine connection

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

Design and Test of Transonic Compressor Rotor with Tandem Cascade

THERMAL STRESS ANALYSIS OF HEAVY TRUCK BRAKE DISC ROTOR

APEC 2011 Special Session Polymer Film Capacitors March 2011

NEW CONCEPT OF A ROCKER ENGINE KINEMATIC ANALYSIS

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Alternator charging and power distribution system

Vehicle Performance. Pierre Duysinx. Research Center in Sustainable Automotive Technologies of University of Liege Academic Year

High reliability against cyclic and peak current loads / age resistant due to high motor start up currents

THE SIMULATION OF ONE SIDE OF TETRAHEDRON AIRBAGS IMPACT ATTENUATION SYSTEM

A study of the power capacity of regenerative inverters in a DC electric railway system

Steering Actuator for Autonomous Driving and Platooning *1

Identification of tyre lateral force characteristic from handling data and functional suspension model

Integrated 1D-MultiD Fluid Dynamic Models for the Simulation of I.C.E. Intake and Exhaust Systems

LM , LM mA and 500mA Voltage Regulators

DESIGN OF THROTTLE BODY: A COMPARATIVE STUDY OF DIFFERENT SHAFT PROFILES USING CFD ANALYSIS

FUSES. Safety through quality

Modeling of Lead-Acid Battery Bank in the Energy Storage Systems

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Analysis and Correlation for Body Attachment Stiffness in BIW

Development of Emission Control Technology to Reduce Levels of NO x and Fuel Consumption in Marine Diesel Engines

Development of Motor-Assisted Hybrid Traction System

OUTPUT SHORT-CIRCUIT CURRENT BEARABLE BY THE UPS

Model-Based Investigation of Vehicle Electrical Energy Storage Systems

Support for the revision of the CO 2 Regulation for light duty vehicles

FUSE TECHNOLOGY Ambient temperature

Design of A Smart Automotive Ventilation System For A Parked Car

Analysis on natural characteristics of four-stage main transmission system in three-engine helicopter

Development of Higher-voltage Direct Current Power Feeding System for ICT Equipment

Homogeneous Charge Compression Ignition combustion and fuel composition

Miniature circuit breaker Application guide

LM , LM mA and 500mA Voltage Regulators

Page 1. Design meeting 18/03/2008. By Mohamed KOUJILI

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

Multi-axial fatigue life assessment of high speed car body based on PDMR method

Dynamic Behavior Analysis of Hydraulic Power Steering Systems

Special edition paper

OVERALL LENGTH (B) " ( mm) " ( mm) " ( mm) " ( mm)

LM ma Low Dropout Regulator

Thermal Analysis of Induction and Synchronous Reluctance Motors

Simulation and Control of slip in a Continuously Variable Transmission

Damping Ratio Estimation of an Existing 8-story Building Considering Soil-Structure Interaction Using Strong Motion Observation Data.

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

The Gear Whine Noise: the influence of manufacturing process on vibro-acoustic emission of gear-box

Transcription:

BEHAVIOUR OF ELECTRIC FUSES IN AUTOMOTIVE SYSTEMS UNDER INTERMITTENT FAULT B. Dilecce, F. Muzio Centro Ricerche FIAT, Orbassano (Torino), Italy A. Canova, M. Tartaglia Dipartimento Ingegneria Elettrica Industrial Politecnico di Torino, Italy Abstract: This paper deals with the behaviour of electric fuses in automotive systems when intermittent faults occur. In this case the fuse intervention time cannot be predicted by means of manufacture fuse characteristic only but a more general dynamic model of fuse behaviour is needed. Here, a simple dynamic thermal model able to take into account this kind of fault is proposed and numerical and experimental tests are presented. I. INTRODUCTION Fuses for automotive systems are mainly used in order to protect electric power distribution network against short-circuiting and overloading. The most critical situations occur when fault current is comparable with the rating of the fuse; furthermore, the presence of an intermittent fault can also influence fuse intervention time; such a fault can be produced by an intermittent contact. The waveform of operating time versus fault current frequency of a stated fault current value is expected to increase monotonically in spite of some results found in literature [ I ] which predicted the existence of a range of critical fault frequencies avoiding fuse current interruption. These last results, based on experimental tests, require an accurate and a satisfactory validation. The paper deals with the behaviour of fuses for automotive applications under the above critical conditions, which cannot be directly predicted by means of technical data given by manufacturers. Therefore, experimental verification were conducted, in order to identify a fuse model, both under step and intermittent input current condition. The model includes the circuit equations and the fuse thermal equations deducing model parameters from the above-mentioned experimental results. The thermal model is implemented by means of equivalence of thermal and electrical systems solved through a SPICE solver for electric circuits. Finally, a parametric analysis, for different amplitude and frequency of the input current, has been performed and compared with experimental results. II. TIME-CURRENT CHARACTERISTIC II I Experimental Measurements In order to perform the experimental measurements, the equipment sketched in Fig. 1 is used. The main components of the circuit are: DC supply: 12V Electronic power switch Current amplitude and frequency controller Shunt and Oscilloscope Automotive 10A Fuse In particular, the current controller imposes a certain constant amplitude with changes of series circuit impedance; moreover, through the electronic power switch it sets the intermittent condition at the requested frequency and duty-cycle, controlling the rise and fall times of the current waveform. + Switch (Fault simulator) DC Supply Current Amplitude and Frequency Controller Fuse Fig. 1. Measurement equipment II.2 Fuse Model Identification % Oscilloscope In order to perform the simulation of the fuse behaviour in presence of an intermittent fault, an identification process of the fuse model based on timecurrent characteristics has to be conducted. 333

The fuse model presented in this paper is electrothermal, and it is implemented by means of equivalence of thermal and electrical systems through a SPICE solver for electric circuits. The component is represented by a bipole in which the relationship between voltage and current is dependent on fuse element and housing s temperatures with respect to the external ambient. These temperatures are function of electric power dissipated on the fuse element. The model is then based on the following equations: a) electrical equation: temperature and power transmitted to the housing by conduction. 2. the power transmitted to the housing is transferred to the external ambient by convection and radiation. This model does not take into account the thermal exchange with the contacts, supposing to consider a very large value for their thermal capacitance. Besides, in the computation of thermal flux, only the fuse element resistance is considered, in order to be closer to the manufacturer s experimental data, conducted in almost ideal and contact-free conditions. The circuit representation of the model equations is depicted in Fig.2. V = Roll1 + (T\ To)a] b) thermal equations: (1) o- (> ROI 2 [1+(TI~TO)OC] = CI - h Kd(T\-Ti) dt (2) Kd( TrT 2 )=C 2 ~ + K,A Ti - T a f p + at where: KijTjS 'Ta/ ) V voltage at fuse element nodes [V] / current through the fuse [A] R 0 fuse element resistance [Q] Ti fuse element temperature [ C] T 2 housing temperature [ C] T a ambient temperature [ C] T 0 reference temperature for the measurement of R 0 [ C] T ik absolute temperature [ K] of an element Ci thermal capacitance of the fuse element fj / C] C 2 thermal capacitance of the housing [J/ C] K ci thermal conduction coefficient between fuse element and housing [W/ C] K ic convection coefficient between housing and external ambient [W/ C] K in radiation coefficient between housing and external ambient [W/ K 4 ] a resistivity thermal coefficient for copper (a = 3.757e-3 1/ C) esp convection exponent The electrical equation represents the electrical behaviour of the fuse element, in terms of a resistance linearly dependent on the difference between T : and T 0. The thermal equations can be interpreted as follows: 1. the thermal flux generated on the fuse element is distributed as power increasing fuse element (3) o- Fig. 2. The circuit model of the fuse A bipole including the series of a resistance R/ and a controlled voltage source E, implement the electrical equation. The independent source with null value V s is a current sensor. The controlled current source G/ is the equivalent representation of the thermal flux, whose value is the dissipated power on the electric bipole. The resistance 1/K t represents the thermal conductance between the fuse element and the housing, whose thermal capacitances are respectively indicated by C, and C 2. The controlled current source G 2 is the representation of convection and radiation phenomena of thermal exchange between housing and external ambient. The identification of model parameters consists in a fitting procedure whose the target is to minimize the root mean square error between the time-current characteristic calculated and the one provided by data manifacturers, for a certain set of currents. This procedure is implemented in the solver MATE AB, and is based on a specialized routine, that accepts a scalar valued function F(X) and an initial guess X 0 for the vector variable X. It returns a vector X, that is a local minimizer of F(X) near the starting vector X 0. In this case X is the vector of the model parameters, and F(X) is a suitable norm of the vector difference between the calculated curve and the manifacturer s one. As can be seen in Fig.3, there is a good link between the experimental characteristics, defined by a maximum and a minimum curve, and the calculated ones, provided at two different temperatures in order to take into account 334

the external temperature excursion during the measurements. At a fixed frequency and for a certain peak current value, a number up to 11 measurements was carried on, in order to take into account the statistic variance in the fuse behaviour. E F Measured (Min.) Measured (Max.) Simulation (25 C) Simulation (23 C) _L III.2 System Model Identification In order to simulate the whole electrical system, the circuit represented in Fig.5 has been implemented in the SPICE solver. 15 16 17 Current [A) Fig. 3. Fuse time-current characteristic under step constant current III. INTERMITTENT FAULT BEHAVIOUR III.l Experimental Measurements O' FUS RES The measurements were conducted on a 10A ATO Blade Fuse designed by LITTELFUSE. The ATO Blade Fuse is a family currently used on almost all car, trucks, buses and off the road vehicles worldwide. The single wire used in the experiment is a 1 mm 2 cross section of automotive low-voltage cable. The simulation of the intermittent short circuit requires a stepwise current with different values of amplitude and frequency. The controller depicted in Fig. 1 sets these current parameters. In particular, the values chosen for the peak of the stepwise current were 20, 22.5 and 25A. The frequency values were fixed to 10, 50, 100 and 200 Hz, and in each test the duty-cycle was assumed to be 0.5 In Fig.4 an experimental survey of the circuit current, is represented. «-ft<y-n 15;52:3$ j 23 IN T/2 T/2 4 3fF I ;, -yw.b-;.ip* I! Pr.c i. VJCM Fig. 5. The equivalent circuit of the whole electrical system This is an equivalent circuit, that involves a constant DC source, an ideal switch to produce the intermittent current, the fuse model identified basing on the time-current characteristics, and an electro-thermal macro-model of the remaining part of the circuit. In Fig.6 the electro-thermal macro-model of the part of the circuit including wires and terminations, is presented. O' T l/k ^A/V- -i + c> Imax Fig. 6. The circuit model of the remaining part of the circuit 1 l** DC 2 s mt ts. i 2M DC 1 2 I «nr. TM ; rvs TCFfCi The series including the resistance /?/ and the controlled voltage source E h in which a certain amount of power is generated, represent the electrical part of the model. The thermal flux, represented by the controlled current source G,, is flowing to the external ambient through the thermal conductance Kj\ the capacitor C/ Fig. 4. Supply current during intermittent fault analysis. 335

represents the thermal capacitance of the electrical part considered. In Fig.7 and Fig.8, simulated waveforms of intermittent current (Imax=22.5A) and fuse element temperature are represented for f=10 Hz and f=50 Hz. 20 A 100"C 16 A 10 Measured (average) 20 A Calculated 20 A A Measured (average) 22.5 A A Calculated 22.5 A Measured (average) 25 A O Calculated 25 A 2 A 50 "C 8 A 1-5- r 4 A O'C 0A 0.2 S 0.4 s 0.6 s 0.8 s time 1.0 s 1.2s 1.4s Fig. 7. Current and temperature waveforms for 1=22.5A, f=10hz 150'C 24 A 20 A 100 "C 16 A 12 A 50 'C 8 A 4 A 0'C OA Os 0.2 s 0.6s 0.8s 1,0s 1.2S 1.4s Fig. 8. Current and temperature waveforms for 1=22.5A, f=50hz The temperature waveforms in the two curves have almost the same mean value, but the amplitude of the curve in Fig.7 is higher, contributing to a smaller melting time for the case of f=10 Hz. In Fig.9, the comparison between the measured and the computed melting times, is presented. It can be noticed that, for a fixed current peak value, the melting time has a monotonically increasing flow with the frequency of the applied waveform. Moreover, the calculated values share quiet well the measured data, since for each couple currentfrequency considered, the melting time computed is included in the range of the experimental data. 50 100 Frequency [A] 150 200 Fig. 9. Computed and measured melting times vs. current frequency IV. CONCLUSIONS In this paper, the behaviour of electric fuses in automotive systems under intermittent fault is examined. The condition of an intermittent short-circuit has been reproduced by supplying a pulse-wise current to a 10A ATO Blade Fuse. A parametric analysis has been conducted; the range of current amplitude has extended from 20 to 25A, and the supplied frequency from 10 to 200Hz. Unlike the results of a typical case-study in literature [1], the present analysis has revealed a monotonically increasing behaviour of melting time with frequency of the input current. ACKNOWLEDGEMENT The authors wish to thank Mr. F. Quarona (Politecnico di Torino) for his support in experimental parts of this paper. REFERENCES [1] J. Suzuki, Y. Tamura, Japan Automobile Research Institute, Ignition Process of Intermittent Short-Circuit on Modeled Automobile Wires, Copyright 1996 SAE, Inc. 336

SIREAEB