Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Similar documents
Instruction Manual. Series E7 Metering Pumps. For file reference, please record the following data:

Basic Instruction Manual for AA, B, C, E, J5 and P Pumps

For file reference, please record the following data:

ROYTRONIC Series A Electronic Metering Pumps Instruction Manual Manual No : 2002 Rev. : D Rev. Date : 12/2016

Instruction Manual Series A Electronic Metering Pumps

Instructions Manual Roytronic Série P + Electronic Metering pumps

Instruction Manual Series HH Electronic Metering Pumps

Series C9 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1619, 1795 Rev. : G, E Rev. Date : 6/09, 10/2015

Series C1 Electronic Metering Pump. Specification Sheet and Assembly Details Manual No : 1619, 1829 Rev. : G, D Rev. Date : 6/09, 10/2015

INJECTION CHECK VALVE DISCHARGE TUBING SPACER, E.P.U

Uni-Dose. For file reference, please record the following data:

ROYTRONIC EXCEL Series AD Electronic Metering Pumps Instruction Manual Manual No : 2024 Rev. : E Rev. Date : 11/2015

Series C7 Electronic Metering Pump. Metering Pump Component Diagram INJECTION CHECK VALVE COUPLING NUT DISCHARGE TUBING 4 FUNCTION VALVE

Instruction Manual. ROYTRONIC EXCEL Series AD Electronic Metering Pumps

Instruction manual EXCEL Series AD

Instruction Manual. This Manual should be made available to persons responsible for Installation, Operation and Maintenance. Pump Model No...

Instruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:

Series A. Series A. Model A S I

INSTALLATION INSTRUCTIONS FOR THE TRUCK MOUNTED VIPER ADDITIVE INJECTION SYSTEM GTP-8776C

PUMP OUTPUT = MAX PUMP OUTPUT x % SPEED x % STROKE

ALLSTAR DILUTION CONTROL SYSTEM MODEL 639AG-4-1ABC

Excellence through Versatility

E.R.I.C. Series Electronic Metering Pump Installation & Operation Manual (Enhanced Control) Manual No.: Revision : 00 Rev.

Sachs shock manual. ( ) 2 & 4 Stroke RR Enduro. ( ) RS Dual Sport

EH Series High Viscosity Electronic Metering Pumps Instruction Manual

MOTOR. The electric motor. DC - direct current voltage.

M OTO R. The electric motor. DC - direct current voltage.

Solenoid Chemical Metering Pump. Operating Manual

READ ALL CAUTIONS CAREFULLY BEFORE INSTALLING PUMP SEE PAGE (4) SERIES 100/150 INSTRUCTION MANUAL P/N CDE: IM120 E/07

DEMA BLEND CENTER MODELS: 637GAP-1 and 637GAP-4 INSTALLATION INSTRUCTIONS

DEMA BLEND CENTER MODEL 681GAP-3 INSTALLATION INSTRUCTIONS

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Precision-24 Manual & Specification

IWAKI AMERICA EHC/EHE-FF Series Electronic Metering Pump Instruction Manual

Operating Instructions ProMinent Low Flow Dual Metering Pump (S-2) Dosing Package

ProMinent Beta Solenoid Diaphragm Metering Pumps

INSTALLATION INSTRUCTIONS DEMA BLEND CENTER MODEL B-GAP, T-GAP

Chem-Feed Installation Instructions

DEMA BLEND CENTER MODELS: 633GAP INSTALLATION INSTRUCTIONS

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

IDS INDUSTRIAL DISPENSER INSTRUCTIONS ISO SAFETY INSTRUCTIONS

Electronic Metering Pumps Series C, C PLUS, A PLUS, E, E-DC, E PLUS and HV

Manual. MicroTron. Series B. Installation Maintenance Repair. Manual. Chemical Metering Pump

SOLAROY 12 VDC Metering Pump

Backpack Sprayer. Use and Care Manual

DIAPHRAGM METERING PUMPS

Industrial Turbo Meters, Sizes 2" through 6"

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

Ph: (07) Fax: (07) Pump Manual

MicroCoat System Operating Manual MC4000 Series MC785M, MC785M-WF Spray Valves

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

Pump Operating and Maintenance Manual - Models

MODEL: ATV Volt, 15 Gallon ATV Mounted Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

ADJUSTING PRESSURE USING THE BOOM NOZZLES OPERATION

PolyBlend PB Siemens Water Technologies Corp. PO Box 389 Bradley, IL (815) Phone (815) Fax 02/07

The following precautions should be taken when working with metering pumps. Please read this section carefully prior to installation.

ATD-6810 SPRAY GUN W/CUP INSTRUCTION MANUAL

Rancher Hydraulic Chute Owner s Manual.

Distributed by: M&M Control Service, Inc

Fisher 657 Diaphragm Actuator Sizes and 87

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 13 HP DIRECT DRIVE PRESSURE WASHER CATALOG NO

TABLE 1-1 GPM FLOW RATE PROPORTIONER, 1/4 I.D. TUBING Injection Rates For Viscosities Shown Metering Tip Color

PolyBlend PB16-1. Siemens Water Technologies Corp. PO Box 389 Bradley, IL (815) Phone (815) Fax 12/06

MicroTron Series C. Manual. Installation Maintenance Repair. Manual. Chemical Metering Pump

Dosing Pump Operational Manual

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Series MP. Installation Operation Maintenance Instruction ELECTRONIC METERING PUMPS READ ALL WARNINGS CAREFULLY BEFORE INSTALLING

OWNER S MANUAL Model: LG ( ) (15 Gallon Lawn & Garden Trailer Sprayer)

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

This Digital Timer is accurate to the minute, designed with either 6 or 8 ON/OFF(event) per day Graphic description, as below: Programmed input

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

INSTRUCTIONS DURA SHOT S SPRAYERS DIRECTIONS FOR OPERATING DURA SHOT S. 24 oz. DURA SURE SHOT S SPRAYER.

RF Point Level Control with Sensor Monitor

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

Manual. MicroTron. Series C. Installation Maintenance Repair Manual. Chemical Metering Pump

OWNER S MANUAL. Model: UTV-65-BL ( ) (65 Gallon Lawn & Garden UTV Sprayer w/boomless Boom)

MODEL NO. UTL-60-7

1 MECHANICAL FUEL METER

Fisher 2506 and 2516 Receiver/Controllers

2506 Series Multi-Trol Receiver/Controllers (Types 2506, 2516, 2516F)

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

WATCH GUARD 440 SERIES FLOAT VALVES INSTALLATION INSTRUCTIONS MODELS: T, TX, T, BT,

SERVICE GUIDE 8540-B 8549-B C. High-Pressure Lubricant Pump DESCRIPTION. Pump Assembly. Specifications

Used on 564 SS Gas Fireplaces Only. #8 x 3/8 Sheet Metal Screws. Upper and. Lower Grills. Heat Shield

12 SERIES. Product Information. Performance & Specs. All 300 Series S.S. construction. Compact, easy to mount 11" x 9" x 3", weighs only 7lb. 2 oz.

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

PROMAX INSTRUCTION MANUAL

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

OWNER S MANUAL. Model: TR-40-GAS ( ) (40 Gallon Lawn & Garden Trailer Sprayer w/5-nozzle Boom Assembly) Technical Specifications

B14 AAA FINE FINISH SERIES PUMP OUTFIT

Model &

Operating Instructions ProMinent. Backpressure and Pressure Relief Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Owner's Manual. Model: ATVBK-3025 ( ) (Boomless Nozzle Kit for ATV Mounting) Technical Specifications. Assembly. General Information

Operating Instructions ProMinent Low Flow Single Metering Pump (S-1) Dosing Package

PMV P36C AND P41C POSITIONERS ACTUATORS

OWNER S MANUAL. Model: LG-25-BL-QR ( ) (25 Gallon ATV Dual Nozzle Sprayer) ***IMPORTANT REMINDER*** Technical Specifications

Double Diaphragm with Pressure-Type Leak Detector. For MILROYAL, CENTRAC B And MAXROY

Transcription:

Instruction Manual Series E7 Metering Pumps For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your LMI Pump, please include the complete Model Number and Serial Number of your unit. 1 Replaces same of Rev. B 4/96 1718.C 10/97

Contents 1.0 Installation... 3 1.1 Unpacking... 3 1.2 Location and Mounting... 3 - Suction Lift Installation... 3 - Flooded Suction Installation... 3 - Prevent Syphoning... 4 1.3 Electrical... 4 - Output Adjustment - Initial Approximation... 5 - Procedure for On-Site Volumetric Calibration E7 in Internal Mode... 6 - Procedure for On-Site Volumetric Calibration E7 in External Mode... 6 2.0 Troubleshooting Liquid End... 7 2.1 Low Pump Output... 7 2.2 Excessive Pump Output... 8 2.3 Changing Pumping Liquifram (Diaphragm)... 8 3.0 Exploded View... 10 4.0 Parts List... 11 2

1.0 INSTALLATION 1.1 UNPACKING Remove tubing, injection check and foot valve (if included) from the pump carton. Notify delivery carrier immediately if there are any signs of damage to the metering pump or parts. 1.2 LOCATION AND MOUNTING a) When pumping solutions, make certain that all tubing is securely attached to the fittings. It is recommended that tubing or pipe lines be shielded to prevent possible injury in case of rupture or accidental damage. Always wear protective face shield and clothing when working on or near a chemical metering pump. b) LMI accessories used with the Series E pumps must be placed in an explosion proof enclosure or located in an area where they will not be subjected to explosion hazard. c) Be sure installation does not constitute a cross connection. Check local plumbing code. A. Locate the pump in an area that is convenient to both solution injection point and electrical supply. LMI Series E7 metering pumps have corrosion resistant housings, but should not be subjected to continuous high temperature (over 122 F or 50 C). B. Mount pump as shown below. Secure pump to shelf with 5/16" bolts through the four (4) holes in the pump base. Shelf must be able to support 50 lbs minimum (23 kg). C. Figures 1 and 2 (below) show typical metering pump installation methods. Note location of injection check valve which is most important. Refer to separate Liquid Handling Assembly Instructions Section A regarding installation of injection check valve. FLOODED SUCTION INSTALLATION helpful when pumping at very low rates SUCTION LIFT INSTALLATION TEE OR TAPPED HOLE LMI CORPORATION STOP AND NOZZLE ASSEMBLY LMI INJECTION VALVE ASSEMBLY SOLUTION LMI METERING PUMP Figure 1 Figure 2 3

D. BACK PRESSURE REQUIREMENTS All electronically controlled magnetically driven pumps maintain maximum velocity on the discharge portion of their stroke regardless of the stroke frequency setting. If there is little or no resistance (back pressure), the velocity of the pumped fluid will be so great as to cause over-pumping. Because of this characteristic, back pressure equal to approximately 25 psi (1.7 Bar)* must be supplied by an anti-syphon/back pressure valve if the system pressure at the injection point is not high enough to provide the needed back pressure. * 10 psi (0.7 Bar) for Series E74. PREVENT SYPHONING When pumping downhill or into pump suction, always use (a) a 4FV at pump discharge and (b) an injection check valve at injection point (see Figure 2 below). bc RE-CIRCULATION PUMP SOLUTION a LMI METERING PUMP a CIRCULATING PUMP SUCTION LINE LMI METERING PUMP SOLUTION b Figure 2 1.3 ELECTRICAL Installation wiring must conform to U.L. listings and local electrical codes. The external trigger circuit is isolated and has the same characteristics as the other LMI Control Code 7 Series metering pumps. Minimum time in low impedance state (on) is 50 milliseconds. Minimum time in high impedance state (off) is 100 milliseconds. 4

METHOD OF TRIGGERING A SERIES E PUMP WIRING DIAGRAM 1. Switch Closure Switch closing triggers pump 2. NPN Transistor Base goes high to trigger pump Violet- Orange + Orange + Violet - THERMOSTAT WHT RED BLU RED POTENTIOMETER (SHOWN IN EXTERNAL MODE) ORN (+) VIO (-) GRY (-) RED (+) TRIGGER 15 VDC (8 MA) 3. PNP Transistor Base goes low to trigger pump Orange + Violet - EPU YEL BLK (HOT) WHT (NEUTRAL) GRN (GROUND) POWER 4. Opto Isolator Orange + Violet - UNIPULSER ASSEMBLY Figure 3 Figure 4 LMI accessories used with the Series E pumps must be placed in an explosion proof enclosure or located in an area where they will not be subjected to explosion hazard. OUTPUT ADJUSTMENT - INITIAL APPROXIMATION A. Speed control dial is graduated in approximate percent of maximum strokes per minute (spm). Turning this knob clockwise increases pumping frequency. OUTPUT ESTIMATE - Total output of pump may be estimated by multiplying stroke frequency (percent of maximum) by stroke length setting (percent of maximum). For example, if the stroke length knob is set at 100% of maximum and the stroke frequency is 20% of maximum, total pump output will be approximately 20%; if the stroke length knob is set at 30% of maximum and stroke frequency is 20% of maximum, total output will be approximately 6% of the pump s maximum rating. This is.2 x.3 =.06 or 6%. B. To determine exact frequency in strokes per minute at any speed knob setting, count number of strokes for one minute. C. Stroke length adjustment knob is the lower of the control panel knobs. Adjust by rotating to desired setting, while pump is stroking. D. SETTING Maximum output of the pump is obtained with stroke frequency knob set at maximum and stroke length knob set at maximum. If pump is to be used at less than maximum output, best volumetric efficiency will be achieved if stroke length knob is left at maximum, and stroke frequency knob rotated counter-clockwise to reduce pump output. If more output reduction is required than can be achieved by reducing stroke frequency, reduce output by turning the stroke length knob counter-clockwise. E. After installation is complete and an initial approximation setting has been made, the pump should be calibrated and the stroke frequency and/or stroke length settings adjusted. F. Nominal output and pressure ratings are at 100% settings of stroke frequency and stroke length. 5

Max. Pressure Rating Max. Output Series psi Bar GPH l/h E70 300 20.7 1.3 4.9 E71 150 10.3 2.5 9.5 E72 100 6.9 4.0 15.1 E73 60 4.1 8.0 30 E74 25 1.7 20.0 76 PROCEDURE FOR ON-SITE VOLUMETRIC CALIBRATION E7 IN INTERNAL MODE A. Make certain speed control knob is turned fully clockwise. Turn off power to pump. B. With pump primed and discharge tubing connected to the injection point as it would be in normal service, place foot valve and strainer assembly in a graduated container with a volume of 500 ml or more (so that the volume displaced by tubing and foot valve assembly is minimal in relation to volume of the solution in the container). C. Turn pump on, and pump until air is exhausted from the suction line and pump head. D. Turn pump off, note the solution level in the graduate. Refill graduate if necessary. F. Turn off pump at the end of the calibration period, note volume pumped during the calibration period, and calculate volume of solution pumped in the time unit you choose (minute, hour, day, etc.). G. Adjust stroke frequency and/or stroke length knobs to your best estimate of required correction, and repeat calibration measurements as a check. PROCEDURE FOR ON-SITE VOLUMETRIC CALIBRATION OF E7 IN EXTERNAL MODE A. Since pump output is governed by an external device, only the output per stroke may be calibrated. B. With pump primed and discharge tubing connected to the injection point as it would be in normal service, turn off pump and place foot valve and strainer assembly in a graduated container with a volume of 500 ml or more. C. Turn pump to internal mode with speed knob set at 100 and operate until air is exhausted from suction line and pump head. D. Turn pump off and note solution level in graduated container. Refill graduate if necessary. E. Turn pump on and count the number of strokes for exactly one minute. Then switch pump off. F. Note volume pumped during the calibration period of one minute. Divide into this, the number of strokes to determine the volume of solution pumped per stroke. Example: 50 ml/100 spm = 0.5 ml per stroke. Multiply this by your expected stroke rate per minute, per hour or per day and compare with desired output requirements. G. Adjust stroke length knob (lower knob) to your best estimate of required correction and repeat calibration procedure. You may elect, for safety and convenience, to do the first calibration or operating test with water or other nonhazardous solution. If so, make certain the water or test fluid is removed from the Liquid End before pumping solutions that may react with the test fluid or be exothermic, such as sulfuric acid. The final calibration adjustment should be made with pumping conditions identical to conditions of normal pumping service. This means that factors such as injection pressure, fluid viscosity, suction lift and others will automatically be accounted for in making the final adjustment of the pump. 6

2.0 TROUBLESHOOTING LIQUID END 2.1 LOW PUMP OUTPUT Low pump output can be caused by many things. Some of the more common ones are: Very low stroke setting, i.e. red zone setting of knob Trapped air in pump head (trapped air in discharge tubing has no effect) Air leak through valve seal rings Ruptured pumping Liquifram (diaphragm) Clogged Liquid End, or injection point connection Injection into pressure within 25 psi (1.7 Bar)* of pump s maximum pressure rating with anti-syphon spring in place (if so supplied) Injection into pressure in excess of pump rating-see chart on page 6. * 10 psi (0.7 Bar) for Series E74. A. Very low stroke setting - Check position of stroke length knob (lower knob) by rotating it counterclockwise until Liquifram (diaphragm) stops moving with the pump operating. The Liquifram should not stop reciprocating (moving or clicking) until the knob points to zero. If it stops before zero, reset knob by grasping the knob and pulling it towards you. Pry the yellow cap off of the knob. Place the knob on a flat surface. Using needle nose pliers, squeeze the inner section together while lifting the outer section up (see Figure 5, below). Stroke Shaft Figure 5 Push the inner section back onto the D shaped stroke shaft. With the pump running, zero the pump by turning the inner section of the knob counter clockwise. Position the outer section of the knob so that the pointer aligns with zero on the nameplate. Push down on the outer section of the knob (a snap sound will indicate that parts are locked together). Replace the yellow cap over the outer section of the knob, aligning the tabs on the cap with the slots on the knob. B. Trapped air in pump head - May be caused by leaks in the suction line, where the suction line joins the suction fitting, or at the seal ring between suction fitting and pump head. It may also be caused by air or gases coming out of solution. Trapped air or bubbles in the discharge line have no effect on the pump s operation. They may be ignored. To remove trapped air from the pump head, operate the pump with stroke frequency knob and stroke length knob set at 100. It may be neccessary to pull on both knobs of the 4FV, or rotate pressure relief knob ¼ turn, if so equipped. Follow Priming instructions in the Liquid Handling Assembly Sheet inserted in this instruction book and operate the pump for a few minutes to purge the head and valves of air or gas. C. Air leak through valve seal rings- usually caused by worn or damaged seal rings or loose fittings. Tighten fittings by hand until they are very snug. If there is no improvement, replace both seal rings in pump head. See enclosed Liquid Handling Assembly Sheet. 7

D. Ruptured pumping diaphragm If rupture is severe and pump is injecting into pressure, solution leak will be obvious through the 3/16" (5 mm) diameter hole at the bottom of the spacer directly behind the pump head. Replace pumping Liquifram (diaphragm). If rupture is a small pin hole, there may be oozing of solution through the 3/16" (5 mm) diameter hole described above. Replacement of pumping Liquifram (diaphragm) will be necessary. E. Clogged Liquid End will cause low pump output. Purge Liquid End. Disassemble Liquid End. Clean individual parts with water and detergent or appropriate cleaning solution. F. Injection into excessive pressure If discharge pressure is within 25 psi (1.7 Bar)* of maximum pump rating, remove spring in injection check valve, if so supplied. * 10 psi (0.7 Bar) for Series E74. 2.2 EXCESSIVE PUMP OUTPUT A. Syphoning If your Series E pump has a Liquid End other than a high viscosity LE, its injection check valve assembly has a chemically resistant anti-syphon spring. Disassemble the injection check valve and check to be sure this spring is in place and undamaged. Replace if necessary. Note that the anti-syphon spring must be removed if injection is into a pressure within 25 psi (1.7 Bar)* of pump s maximum pressure rating. Liquid Ends with a suffix S have, in addition, a diaphragm type anti-syphon valve, which prevents syphoning and over pumping. * 10 psi (0.7 Bar) for Series E74. B. Incorrect knob settings Check stroke length knob (lower knob) by rotating it counter-clockwise to zero position. The Liquifram (pumping diaphragm) should stop reciprocating. If it does not, reset knob and continue counter-clockwise rotation until motion stops. Reset knob by grasping the knob and pulling it towards you. Pry the yellow cap off of the knob. Place the knob on a flat surface. Using needle nose pliers, squeeze the inner section together while lifting the outer section up (see Figure 5). Push the inner section back onto the "D" shaped stroke shaft. With the pump running, zero the pump by turning the inner section of the knob counter-clockwise. Position the outer section of the knob so that the pointer aligns with zero (0) on the nameplate. Push down on the outer section of the knob (a snap sound will indicate that parts are locked together). Replace the yellow cap over the outer section of the knob, aligning the tabs on the cap with the slots on the knob. 2.3 CHANGING PUMPING LIQUIFRAM (DIAPHRAGM) A. Make sure size code marking (0.9 S.I., 1.8 S.I. or 3.0 S.I.) on spacer and Liquifram (diaphragm) are the same. Liquifram and spacer size code must match in order for the pump to function. The E74 Liquifram size code is 6.0 S.I., (spacer is 3.0 S.I., but there is a large black spacer adapter). Always wear protective clothing, gloves and face shield when working on or near chemical metering pumps. B. Depressurize discharge line following steps outlined on the supplement Liquid Handling Assembly Instructions. Lift foot valve from solution and let pump run pumping air for a few minutes. Then remove pump head. C. Set stroke length knob (lower knob) to zero, rotate it counter-clockwise with the pump running, then stop the pump by turning stroke frequency knob (upper knob) to off. D. Lift edge of Liquifram and rotate it counter-clockwise to unscrew the Liquifram. E. Before installing new pumping Liquifram, turn pump on and rotate stroke length control knob (lower knob) to the proper setting per the following table : 8

Stroke Setting Model Length E70, E71, E72 90% E73, E74 70% With pump stroking, screw on new Liquifram until the center part begins to buckle inwards during the latter half of the stroke. Turn pump off and check Liquifram position with a straight edge according to Figure 6 (below). If Liquifram setting is not correct, restart pump then screw the Liquifram in or out. Always stop pump electrically when checking Liquifram setting. Repeat procedure if necessary. After Liquifram is set properly, restart pump and turn stroke knob to 100%. F. Re-install pump head and tighten head mounting screws in criss-cross pattern. Figure 6 9

10 3.0 EXPLODED VIEW

4.0 PARTS LIST Key Part No. For Model No. No. Description Quantity 23 E70, E71, E72 27641 Stud 4 E73, E74 29605 Stud 4 24 E7 26983 O-Ring 1 25 E7 27586 Shim 1 26 E7 35269 Seal 1 27 E70 35837 Spacer, 0.9 1 E71, E72 35838 Spacer, 1.8 1 E73, E74 35839 Spacer, 3.0 1 28 E7 10973 Shaft Seal 1 29 E70, E71, E72, E73 10598 Screw, 10-24 S.S. 4 E74 10598 Screw, 10-24 S.S. 8 30 E7 25452 Label 1 31 E7 31542 Nameplate 1 32 E70, E71 32465 Stroke Dial 1 E72 32466 Stroke Dial 1 E73 32467 Stroke Dial 1 E74 32468 Stroke Dial 1 33 E7 25889 Knob Asm., Speed 1 34 E7 31891 Knob Asm., Stroke 1 37 E74 25887 Adapter, 6.0 SI 1 41 E7 30803 Gasket 1 11

12 1997 LMI Milton Roy - All Rights Reserved Printed in USA Specifications subject to change without notice. Liquifram is a trademark of Liquid Metronics, Inc.