THERE IS NO OTHER EXPRESS WARRANTY.

Similar documents
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC3000 / Item #40885

STEP-BY-STEP INSTALLATION GUIDE

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

SUBMERSIBLE SUMP PUMPS

GARDEN HOSE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

AUTOMATIC SUBMERSIBLE UTILITY PUMP

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

SUBMERSIBLE SUMP PUMPS

Sump / Effluent Pump

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

General Safety Information

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

User Guide IGD Series

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

Model: SE-4020-CA Automatic Battery Charger

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

IMPORTANT SAFETY INSTRUCTIONS

PRE-PLUMBED SEWAGE SYSTEM

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

2/10/50 AMP 12 VOLT BATTERY CHARGER/ ENGINE STARTER

SP6. Automatic Battery Charger. Model

115 VOLT TRANSFER PUMP

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

SUBMERSIBLE MINI-PUMP

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

Model: OBD-L On-Board-Diagnostics II Memory Saver Detector

Submersible Pond Pump with UV 800 Gallons Per Hour

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

PSJ-2212, PSJ-3612, PSJ-4424

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

Operating Instructions

4 AMP WATERPROOF BATTERY CHARGER/MAINTAINER INSTRUCTION MANUAL

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Models: SP3, SPSS3 Automatic Battery Charger

Premium Pond Pump 330 Gallons Per Hour

Cruising Charger Series OWNER S MANUAL

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

LESTRONIC II BATTERY CHARGER MODEL 19740

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

Illumifalls Patio Pond

SUPER PUMP OUT SYSTEM

1/2 HP CAST IRON TRANSFER PUMP

Audi R8. Ride-on Car 5F62630 OWNER S MANUAL. Keep instructions for future reference

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

Premium Waterfall Pump 1200 Gallons Per Hour

M-3025CB-AV Fuel Pump

Operating Manual Includes Pumps: PG-9000 Part #R809606

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

4 in 1 POWER STATION Model: 7226

ESE Series Cast Iron Sewage Pumps

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

Installation and Operating Instructions (for chargers shown below)

installation and operating instructions for the following xtreme Battery chargers:

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

900 PEAK AMP PORTABLE JUMP STARTER

Matson Jump Starter Operator s Manual

PI1500X Power Inverter User s Manual

Battery. Charger Model: Save Important Safety Instructions

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

12V Manual Battery Charger

20A Solar Charge Controller

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

OWNERS MANUAL Models: XP400, XP500, XP750C INSTANT POWER Jump Starter and DC Power Source

Powerful & Intelligent Submersible Pumps

SuperFlo 9,000 High Volume Pump Product Manual

SAVE THESE INSTRUCTIONS

Aqua Ultraviolet Sunami Series Pumps 1/3HP, 3/4HP, 3HP, 4HP, 5HP

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

StormPro BA Series Sump Pump

BATTERY SAVER LOW RIPPLE HO

G8 Portable Fuel Transfer Pump Owner s Manual

Voltmaster Centrifugal Trash Pumps

Submersible Waterfall Pump 1200 Gallons Per Hour

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Power Inverter 400 MW Owner s Manual

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

MODEL 6017 OPERATOR'S MANUAL

JUMP STARTER OPERATOR S MANUAL RA1900

44,400mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

S150,S300 Series Pure Sine Wave Inverter User s Manual

10 AMP ON BOARD BATTERY CHARGER

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

HALLMARK INDUSTRIES INC

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

VAc A. Rc Ah. Table of contents. OpERATION MAINTENANcE. Safety... 2 Specifications... 6 Operation Maintenance Warranty...

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

CP series. Submersible utility pump 50HZ STAIRS INDUSTRIAL CO., LTD.

Transcription:

Operating Instructions and Parts Manual Limited Warranty For one year from the date of purchase, Wayne Water Systems ( Wayne ) will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps ( Product ) found upon examination by Wayne to be defective in materials or work man ship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be pre pared to provide the model and serial number when exercising this warranty. All trans por ta tion charges on Products or parts submitted for repair or replacement must be paid by purchaser. This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper main te nance, or failure to operate in accordance with Wayne s written instructions. THERE IS NO OTHER EXPRESS WARRANTY. IM PLIED WARRANTIES, IN CLUD ING THOSE OF MER CHANT ABIL I TY AND FITNESS FOR A PARTICULAR PUR POSE, ARE LIMITED TO ONE YEAR FROM THE DATE OF PUR CHASE. THIS IS THE EXCLUSIVE REM E DY AND ANY LIABILITY FOR ANY AND ALL IN DI RECT OR CON SE QUEN TIAL DAM AG ES OR EX PENS ES WHATSOEVER IS EXCLUDED. Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above lim i ta tions might not apply to you. This limited warran ty gives you specific legal rights, and you may also have other legal rights which vary from state to state. In no event, whether as a result of breach of contract warranty, tort (in clud ing negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equip ment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer s custom ers for such damages. You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence. Please call Wayne (800-237- 0987) for return authorization and instructions. DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records. MODEL NO. SERIAL NO. INSTALLATION DATE ATTACH YOUR RECEIPT HERE 8

Operating Instructions & Parts Manual PC1 and PC2 Series Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Self-Priming Transfer Pumps Table of Contents Description...1 Unpacking...1 Safety Guidelines...1 General Safety Information...1 Installation...2 Operation...2 Maintenance....3 Troubleshooting Chart...4 Replacement Part Information...6-7 Warranty...8 Description These self-priming transfer pumps are designed to easily transfer water from one point to another. Model PC1, 12 Volt Transfer Pump is convenient when normal power is not readily available. Typical applications include removing water from pool covers, clogged drains, stock tanks, water basins, boats, cisterns, etc. Model PC2, 115 Volt Transfer Pump is great for household usage. Typical applications include removing water from waterbeds, clogged sinks, basements, etc. Note: Do NOT use PC2 in pool areas. The motors on both models PC1 and PC2 are nonsubmersible. Unpacking Inspect this unit before it is used. Occasionally, products are damaged during shipment. If the pump or components are damaged, return the unit to the place of purchase for replacement. Failure to do so could result in serious injury or death. READ & FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS DO NOT DISCARD Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. Notice indicates important information, that if not followed, may cause damage to equipment. NOTE: Information that requires special attention. General Safety Information CALIFORNIA PROPOSITION 65 This product or its power cord may contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Wash hands after handling. GENERAL SAFETY Do not submerge motor or allow motor to be exposed to water. Personal injury and/or death could result. Keep pump and power cords away from liquids. Model PC1 becomes very hot during operation. Do not pump gasoline or other explosive liquids. Do not operate pump where flammable or explosive fumes or gases are present as a fire or explosion could result. Pump should only be used to pump clear water. Do not run pump dry. 1. Read all instructions before operation. 2. Protect electrical cord from sharp objects, hot surfaces, oil and chemicals. Avoid kinking the cord and replace damaged cords immediately. water only. MANUAL This pump has been evaluated for use with Models PC1 and PC2 include a six foot long suction hose, a water suction attachment, and a replacement parts kit 2015 WAYNE Water Systems REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. For parts, product & service information visit 3212 08-001 01/15

Operating Instructions and Parts Manual Installation 7. At times, an overload due to Dangerous overheating, low voltage, jammed which includes: impeller, gasket, shaft seal, and two motor brushes (PC2 only, brushes are not designed to be replaced on PC1). impeller, etc. may shut the pump off. Unplug or turn off the pump and wait at least ten minutes. The pump will cool and automatically reset. (Model PC2 only) Always disconnect power source before attempting to install, service, or maintain the pump. Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur. 1. A ground fault circuit interrupter (GFCI) is required for Model PC2. Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type attachment plug. A grounded receptacle in conformance with current NEC and local codes must be used (See Figure 1). Do not use model PC2, 115 V Transfer Pump in swimming pool areas. 2. Model PC1 operates on 12V DC only. Model PC2 operates on 115V only. Voltage and current of power supply must match the requirements of the pump. Model PC1 has color-coded battery clamps for 12V operation. Model PC1 requires 14 amps at 12 VDC. 3. Never use an extension cord to power this unit. Risk of fatal electrical shock. Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable. 4. Use a strainer when pumping from a creek, pond, or source where foreign objects may be sucked into the pump. The strainer should prevent solids from entering the inlet line. 5. A regular garden hose may be used as a discharge line. 6. The inlet or suction hose should not be longer than 15 feet; and the vertical distance between the pump and the water level should not be any higher than 10 feet. The maximum discharge height is 30 feet. 8. Motor should never be operated for more than 2 hours continuously. Critical heating can occur and might severely damage the pump and void warranty. Operation 1. Add 1 tablespoon of vegetable oil to both inlet and outlet to prime. Attach included 6 foot suction hose to inlet of pump. Attach garden hose to outlet of pump. There must be a gasket in place to insure that these connections are airtight, otherwise the pump will not prime. 2. Connect water suction attachment to the open end of inlet hose and place below water surface. (Water suction attachment is optional for both PC1 and PC2 models.) The water suction attachment is designed to fit the male end of a garden hose. Place the water suction attachment as near as possible to the middle of the water that is to be pumped. 3. Examine the inlet and outlet hoses to insure there are no blockages, kinks or bends. Place switch in OFF position before connecting or disconnecting battery terminal clamps. IMPORTANT BATTERY INFORMATION Be certain that the area around the batteries is well ventilated. Before servicing the batteries, blow away gasses by waving a piece of cardboard near the batteries. hydrogen gas can be released from batteries while charging. Sparks can ignite the gas in an enclosed space. Wear safety goggles when connecting batteries. Battery connections should be made in a wellventilated area. Working in the vicinity of lead acid batteries can be dangerous. Before making connections or servicing the batteries, read and follow instructions in all applicable instruction manuals. To reduce the risk of battery explosion, follow the instructions in this manual and those published by the battery manufacturer, as well as those of any other equipment used in the surrounding area. An assistant should be present or close enough to come to your aid in the event of an emergency. Have a reliable source of fresh water and soap nearby in case battery acid contacts clothing, skin or eyes. Wear eye and clothing protection when working around lead acid batteries. Avoid touching your eyes when working around lead acid batteries. If battery acid contacts your eye(s), flush with cold running water for 20 minutes and seek immediate medical attention. If acid contacts your skin or clothing, wash immediately with soap and water. Never smoke or allow a spark or flame in the vicinity of the battery. Avoid dropping metal tools on the battery posts because they may spark or short-circuit the system or battery, causing an explosion. 4. Connect pump to power source, with pump in a dry location. Model PC1: Motor must be connected to a fully charged automotive tractor or marine type battery to operate. Connect the red clamp to the positive (+) type battery terminal. Connect the black clamp to the negative (-) type battery terminal. See 12V wiring diagram below (Figure 2). Model PC2: Plug into a 115 Volt AC 3-prong ground-type GFCI receptacle. 2

PC1 and PC2 Series Replacement Parts List for Self-Priming Transfer Pumps Description Impeller & Seal Brush Kit Water Suction Attachment PC1 KITS Part No. 66062-103 -------- 66064-002 Description Brush Impeller & Seal Brush Kit Water Suction Attachment Impeller and Seal PC2 KITS Part No. 66058-103 66060-103 66064-002 66062-103 7

Operating Instructions and Parts Manual For Replacement Parts or Technical Assistance, Call 1-800-237-0987 Please provide following information: Address any correspondence to: - Model number WAYNE Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A. BATTERY TERMINAL CLAMPS 12 VOLT POWER CORD POWER SWITCH ON/OFF BRUSH ASSEMBLY (PC2 Only) BRUSH CAP GROUNDING PLUG ROTATION IMPELLER SHAFT COVER RETAINING RING SHAFT SEAL GASKET WATER SUCTION ATTACHMENT Figure 3 Replacement Parts Illustration for Self-Priming Transfer Pumps 6

PC1 and PC2 Series Operation (Continued) Maintenance Always disconnect power source before attempting to install, service, or maintain the pump. 12 VOLT WIRING DIAGRAM Grounding Plug OUTLET INLET RED CLAMP TO POSITIVE TERMINAL BLACK CLAMP TO NEGATIVE TERMINAL TEST RESET + POS - NEG 12 VOLT DC BATTERY Figure 1 12 VOLT DC PUMP IMPELLER REPLACEMENT These parts are designed to handle most clear, nonflammable liquids with slight amounts of abrasives. When impeller vanes become worn from use, or damaged due to pumping abrasive liquids or trash, pump performance will be reduced or prevented altogether. 1. Remove the four cover plate screws holding motor housing and pump housing together. Cover plate is now free and can be removed. 2. Inspect gasket and impeller for wear and damage. If there is any evidence of wear or damage, replace the part(s). 3. Lubricate new impeller with white grease or lightweight oil and reinstall by aligning flat on impeller hub with flat on motor shaft. 4. Reassemble gasket, cover plate, and cover plate screws. SHAFT SEAL REPLACEMENT Motor shafts are sealed with factory pre-lubricated lip-type seals which are good for the life of the pump. If the seal leaks, it is usually because the pump has handled abrasive liquids. If the motor shaft is scored (deep grooves), the complete pump must be replaced. 1. Remove and inspect impeller parts as specified in the impeller replacement instructions. Replace worn parts. Figure 2 motor. Pry out seal retaining ring and push worn shaft seal from inside of pump body. 3. Lubricate new seal with lightweight oil, push it into pump body with lip facing away from motor, and push in seal retaining ring. 4. Reassemble pump body onto motor with mounting screws. Follow steps 3 and 4 in Impeller Replacement. MOTOR BRUSH REPLACEMENT PC1 Model is equipped with lifetime brushes. Brush replacement is not necessary. Brushes for the PC2 pump should be inspected after 75 hours of operation and replace if worn. They must be replaced every 100 hours of operation. Service one brush at a time. 1) Disconnect pump from power supply. 2) Remove brush caps with screwdriver. 3) Remove old brush assembly. 4) Insert new brush assembly. 5) Replace brush caps. 2. Remove two pump body mounting screws and slide pump body from 3

Operating Instructions and Parts Manual Troubleshooting Chart Symptom Possible Cause(s) Corrective Action Pump will not start or run 1. Blown fuse 1. If blown, replace with proper sized fuse or reset breaker Pump will not prime or retain prime after operating Flow rate is too low 2. Low line voltage 2. Voltage of power supply must match the voltage of the pump 3. Worn brushes 3. Replace brushes (PC2 Only) 4. Impeller blocked 4. Remove blockage 5. Motor has overheated (Model PC2 only) 5. Disconnect from power supply and allow to cool (Minimum 10 minutes) 1. Air leak in suction line 1. Repair suction line by tightening inlet connection or replace 2. Impeller blocked 2. Remove blockage 3. Worn seal 3. Replace seal 4. Suction lift too high 4. Lower pump 5. Hose kinked or looped 5. Straighten hose 6. Fittings not tight 6. Tighten fittings 7. Suction hose out of water 7. Submerge suction hose end 8. Clogged inlet 8. Clean inlet 1. Inlet hose plugged or kinked 1. Clean or replace 2. Low line voltage 2. Voltage of power supply must match the voltage of the pump Shaft seal leaks 1. Worn seal 1. Replace seal 2. Shaft grooved 2. Replace pump 3. Pump head loose on motor 3. Insure proper assembly and no obstruction, tighten bolts 4

Notes PC1 and PC2 Series 5