Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

Similar documents
Quick Setup Guide for IntelliAg Model YP Air Pro

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

Troubleshooting a Planter that applies above or below target rate

ROW PRO DOWN PRESSURE

Quick Setup Guide for IntelliAg Model YP

ISOBUS Down Force Hydraulics Kinze

Quick Setup Guide for IntelliAg Model YP Twin Row

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

DeltaForce System Operation

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

Wing-Fold Planters All Makes & Models

Front-Fold Planters All Makes & Models

Advanced User Manual

Reference Manual /12

An ISO 9001:2008 Registered Company

Section 55 Chapter 6

Spray Height Controller

Calibration & Operation Manual

Clutch Control. PN: November 2013 Rev E 1

Display Quick Reference Guide

Blue Bird Instrumentation Operators Guide

Section 35 Chapter 9

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

Indian Speedometer and Body Control Module Service Tool Users Guide

Basic 3-Stage Control Applications & Reference. RJG, Inc. 2002, 2003, 2009

e -Stroke e-s 3 / GEN 3 Tractor / Truck / Bus Parts List

TWO-WAY LCD AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

Installation Guide _02 9/11 1

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

& Tower for PWM Control. Maximum Application Rates with Two 5.3 GPM Electric Pumps

Level-Up Motorhome Leveling

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

SiCan Simple CAN Extension Charger to PacMon

THE witech SOFTWARE LEVEL MUST BE AT RELEASE OR HIGHER TO PERFORM THIS PROCEDURE.

Subject Underhood G System Error Codes and Symptoms System or Parts affected

60 Series Combines By

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

All of the control valves that we install the Mk. 16IQ positioner on are factory calibrated for proper operation prior to shipment.

BRAKE SYSTEM, HYDRAULICALLY ACTUATED - 631G TRACTOR Cat Tractors with standard shoe/drum brakes

Troubleshooting: Installation 10. Troubleshooting: Door Jamming and Door Handing 11. Troubleshooting: Touchscreen 14

Lingenfelter NCC-002 Nitrous Control Center Quick Setup Guide

Adaptronic esel002 Select ECU for RX8 Series 1

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

Diagnostic Trouble Code (DTC) List

with the AgGPS TrueGuide System Quick Reference Card

Operator s Manual. Wi-Fi Air Drill Rate and Blockage ECU. MNST08205 P a g e 1 Software Revision 2.3.0

Troubleshooting: Installation 8. Troubleshooting: Door Jamming and Door Handing 9. Troubleshooting: Keypad 13. Troubleshooting: Smart Home Systems 14

W A L C H E M. PosiFlow FAQs, Installation & Wiring

Dataspeed ADAS Kit FAQ and Troubleshooting Guide

OPERATING INSTRUCTIONS AutoForce

Multi-colour LED Status Light - using it as a diagnostic tool:

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Rostselmash Torum 740

TECHNICAL PRODUCT DATASHEET

Instructions for Micro-Trak Seed Rate Control Systems Used with AgLeader INSIGHT, INTEGRA One, Two and Three Section

On-Board Diagnostic and Tuning Interface

GPS AutoSteer System Installation Manual

TG350 User Manual. Manual Revision: Min. FW Revision: Date Released: 09/01/ DYNAGEN Technologies Inc

NexSysLink. Operation Manual. NMEA 2000 SAE J1939 Indmar Engines. CAN Instruments Product Family

Clutch Installation Case IH 1200 row unit

PN: A. Reactive Steering Kit Installation Manual

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

GCU-10. Automatic Engine Control Unit Operators Manual

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

Troubleshooting: Door Jamming and Door Handing 6. Troubleshooting: Keypad 11. Troubleshooting: Smart Home Systems 12. Troubleshooting: Battery 14

Release Notes. Release Notes Contents. Overview. New Vehicle Coverage - Summary: Version

Pneumatic Control Module User s Guide

Gillig EFAN Diagnostic Software User Guide & Troubleshooting Guide 8A Rev H Last Revised: 3/23/2017

Operations Manual. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL

ULTRA LEVEL MOTORIZED LEVELING

LCI Motorized Leveling - Unidirectional (2009-Present)

CAN-Translator. User s guide

FAN-PWM-V3. Instructions

Mitsubishi. VFD Manuals

John Deere AutoTrac Control ler- Reichhardt PFP11784

EPAS Desktop Pro Software User Manual

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

Product manual Oil Streak Sensor INTRODUCTION CONSTRUCTION. Master Sensor

Feature Description. Version History

Overview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests

Automated Control Electronics (ACE ) System Operation and Diagnostics

Issue 2.0 December EPAS Midi User Manual EPAS35

NEW HOLLAND TM120 TM130 TM140 TM155 TM175 TM190 SUPPLEMENT TO OPERATORS MANUAL

MAGPOWR Spyder-Plus-S1 Tension Control

ADVANTAGE PLUS Installation Instructions

MSD LS Ignition Control PN 6014/60143

LIFTWATCH 5 RATED CAPACITY INDICATOR

PCS GEAR SELECT MODULE USER GUIDE v4.0

USER MANUAL HART. ValveSight Diagnostics For Logix MD Positioners with HART FCD VSENSF AQ 03/15 FIELD COMMUNICATION PROTOCOL

Raven RS1 Guidance and Steering Calibration & Operation Manual. P/N Rev. A 09/17 E29677

DJ - RAM 2500 PICKUP - 6.7L I6 CUMMINS TURBO DIESEL

LED Reference for Circuit Board

MGL Avionics EFIS G2 and iefis

Installation, Operation and Maintenance Manual

Transcription:

To create a configuration, make the following button presses to start the Configuration Wizard and then follow the instructions given on the display. Planting Start of Configuration Wizard Enter Settings Configuration Product Planting Press to Highlight Configuration 8360,1770,3dr Down Force Select planter type (drop down menu) If using uplift springs, enter value as defined in installation instructions Places an upper limit on the amount of supplemental down force Gauge Wheel Load Alarm Alarm will trigger if any monitored gauge wheel load is below this value for a duration of time Alarm will trigger if any monitored gauge wheel load is below Minimum Load for this amount of time Control Settings Down Force Control Mode (drop down menu) Monitor Only: Select this option if only using gauge wheel sensors in conjunction with other supplemental down force products (i.e. manually adjusted springs or airbags) Control: Select this option is using Ag Leader hydraulic down force actuator and gauge wheel sensors. This option allows for active down force control Enabling this option will disengage active control (hold) when any portion of the planter enters a no plant zone, such as boundaries, or previously planted areas. Use caution with this option if planting long point rows. Alarms are disabled when system is in hold. Value must be entered for your specific planter and parallel arm combination Kinze 3000 series 4.2 PSI/lb John Deere Max Emerge/XP with short parallel arms 4.5 PSI/lb John Deere Max Emerge/XP with long parallel arms 3.8 PSI/lb te: Some planters may have a combination of long and short parallel arms depending on accessories. In this case use the value that represents the majority of the rows. 1

Manually entered values depicting tractor s hydraulic pressure. Values shown are for a 3000 PSI system (most common) Select Channel to Calibrate 1. Set Point: Enter value here that matches value displayed on the corresponding channel s mechanical gauge attached to Ag Leader Down Force valve. (This can be done at 0 PSI) 2. Slope: value is dependent on manufacture of pressure transducer. Use 0.75 PSI/mV for transducer supplied with valve. Pressure Sensor Enabled: must be enabled to display Down Force on run screen. Duty Cycle Minimum/Medium/Maximum: Manually entered values correlating PWM duty cycle to hydraulic pressure supplied to Down Force actuators. Values shown are for the Ag Leader supplied hydraulic down force valve. PWM Frequency: Number of PWM signals per second (Hz) Row Unit Sensors Enabled sensors will be used to calculate required supplemental down force To start the Field Operation Wizard and load a configuration: Configuration To view run screen: Start Field Operation 2

Gauge Wheel (bar graph): Each bar displays gauge wheel load for monitored rows Down Force (bar graph): Each bar displays supplemental down force for monitored rows Down Force a. Gauge Wheel: Planter average gauge wheel load b. Down Force: Planter average supplemental down force Planter Options - Down Force tab Status: displays current status of control system Active: System is actively controlling down force Inactive: System is not actively controlling down force Hold: Pressure is being held constant due to manual hold or automatic hold Gauge Wheel: Instantaneous channel average gauge wheel load Down Force: Instantaneous hydraulic pressure Pressure: Pressure reading from corresponding channel pressure transducer Gauge Wheel By Row (table): Instantaneous gauge wheel load for each monitored row Automatic Control (button): Active down force control mode. Gauge Wheel Load: User selected aggressiveness. Higher aggressiveness will equate to higher gauge wheel loads Manual Control (button): Allows user to manually adjust pressure supplied to down force actuators across planter. Active down force is disabled when in this mode. Active Manual Inactive Manual Hold 3

CAN A HIGH POWER LOCAL CAN BUS SIGNAL/CONTROL Terminator P/N 4002871 Right End of Planter Terminating Plug P/N 4002871 must be installed on the right end of the planter. At least one implement switch must be installed on the Seed Command system. Row Module P/N 4002912-1 Row Module Breakout Row Module P/N 4002912-1 Cable Diagram Load Sensor Load Sensor Row Module Breakout Channel 2 Solenoid Valve Channel 2 Pressure Down Force Control Module Channel Cable Channel Cable P/N 4002920-008 Dust Cap Channel 1 Solenoid Valve Channel 1 Pressure Control module and Implement Switch module(s) can be placed anywhere in series on the local CAN Bus. Row Module P/N 4002912-1 Load Sensor Row Module Breakout CAN Implement Switch P/N 4002911 Implement Switch P/N 4000726-12 P/N 4002658 Row Module P/N 4002912-1 Load Sensor Terminator P/N 4002870 Left End of Planter Row Module Breakout Terminating Plug P/N 4002870 must be installed on the left end of the planter. 4

Installation: Hydraulic Down Force FAQ Where do I plug in an implement switch? Generation 1 modules will broadcast the implement switch status over the CAN bus. additional implement switch is needed. What if I don t have any other generation 1 modules? You will use the Ag Leader CAN implement switch module P/N 4002911 and cable P/N 4002658 in conjunction with the standard implement switch. What if my cables don t reach the rows for which I have installed gauge wheel sensors? It may be acceptable to choose rows the cables will reach, as long as channel 2 sensors are on the center 6 rows, and channel 1 sensors are outside that. What if I don t have any free SCV connections for the down force valve? Teeing into existing lines is acceptable. Do not tee into the vacuum fan line if adjusting fan RPM on the tractor with a knob or dial. Teeing into the line before a flow limiter on the planter would be acceptable. Teeing into the hydraulic drive supply line would be the best option. Do not tee into Rawson Drive supply line. What if my hydraulic oil gets too hot? Ag Leader sells a Load Sense kit (P/N 4101225) to help manage oil temperatures. te: This system will not help if using SCV to control hydraulic drives. In this case, an auxiliary oil cooler may need to be installed. What if my hydraulic actuator does not extend far enough to reach the lower bracket with row unit at bottom travel? Purchase one spacer kit (P/N 4101201) per row. This will install at the bottom of the ram. (Commonly used on John Deere long parallel arms) My Kinze planter has rows that are offset 4 back, causing the upper actuator bracket to not line up with the lower actuator bracket. Purchase one spacer kit (P/N 4101204) per row. This will move the upper bracket 4 rearward. How does the system know the difference between the row modules on channel 1 and those on channel 2? The Channel 1 row modules will connect to the cable labeled Type 1 while channel 2 row modules will connect to Type 2 cables. 5

Installation: Hydraulic Down Force FAQ Am I missing something to plug into the 3 pin connector on the master hydraulic down force module? This connector is not used. Why is the gauge wheel load bar graph constantly spiking and then going to 0? This can happen if the Channel 1 pressure lines are routed to channel 2 sensors. Ensure channel 1 components (Down force pressure, and gauge wheel load sensor wiring) are on the wings, and channel 2 components are on the center 6 rows. Ensure channel hoses are going to correct channel of down force valve. Ensure PWM/pressure sensor cables are going to correct channel of Down Force Module and Down Force Valve. What are the red knobs on the down force valve? This allows for manual adjustment of down force in the event of electronics failure. Push and twist the knob to move between automatic adjustment (inner position) and manual adjustment (outer position). Why does the system need 3 hydraulic lines (Pressure, Return and Tank) Under normal operation, pressure in the down force system is increased through the Pressure line and relieved through the Return line. When the planter runs over a terrace or a water way, the access pressure is released through the Tank line. All three lines MUST be connected. 6

Hydraulic Down Force Alarm Explanation and Resolution Down Force Inadequate Problem: System is at maximum hydraulic pressure, but does not achieve an acceptable gauge wheel load. Often times this alarm occurs when down force actuators are lifting the planter tool bar. Resolution: Add weight to planter. If planter tool bar is not lifting, increase maximum down force setting in configuration setup. Hydraulic Pressure too low Problem: Hydraulic pressure is at 0 and the system is demanding more pressure. Resolution: Check hydraulic hoses for proper connections. Ensure SCV remote is set for continuous flow. Zero each channel s pressure sensor only when mechanical gauge reads 0 psi. Low Gauge Wheel Load Problem: Down force system is not achieving an acceptable gauge wheel load. Resolution: Increase aggressiveness for problematic channel under settings button from run screen. This alarm may be followed by Down Force Inadequate, in which case consult that alarm resolution section. Pressure Sensor Failure Problem: Pressure sensor is outside voltage range. Resolution: swap cables with other channel (if applicable), re-zero pressure sensors. If problem persists on same channel, replace pressure sensor. If problem is now on other channel, inspect/ replace cable. Row Module Communication Lost Problem: Row module communication lost. Resolution: Inspect cabling of row module. Replace row module. Row Module Failure Problem: Row module is not sensing inputs. Row module is power cycling at intervals of less than 2 seconds Resolution: Swap module with different row. If problem follows, replace module. If problem exists on same row, inspect or replace load sensor. # Row Modules does match the display configuration Problem: Configuration was set to a number of sensors that was not detected by the system. Resolution: Create a configuration that matches the number of sensors used. Check that all row modules are communicating. Flashing green LED on the row module indicates proper communication. 7

Troubleshooting Step 1A: Hydraulic Down Force Start Latest Display firmware? Upgrade firmware Down Force icon present on lower right run screen. Enter 5 mph manual ground speed. Down Force Module Communicating? Go to Step 2: Cables and Power Is arrow icon green when planter is lowered? Go to Step 3: Implement Switch Connections Operating Configuration set to control? Set Operating configuration to Control instead of Monitor Only Is arrow icon yellow when planter is raised? Go to Step 3: Implement Switch Connections Restart field operation, select Down Force on Product Selection screen accept Down Force Warning Go to Step 1B: Hydraulic Down Force 8

Troubleshooting Step 1B: Hydraulic Down Force Continued from Step 1A: Hydraulic Down Force Engage down force hydraulics. In Manual Control click the increase arrow several times. Does pressure increase? Go to Step 4: Hydraulics Put planter in down position with load on gauge wheels. Place in manual control at maximum pressure. Enter down force module diagnostics. Do all row sensors register a load reading? With planter still in down position with load on gauge wheels and in manual control at maximum pressure Can the gauge wheels on the monitored rows be turned by hand? Go to Step 2: Cables and Power Move to softer ground or pull forward. The opening discs are not digging into the ground. Decrease pressure in manual control. Does the pressure displayed go down. Go to Step 4: Hydraulics Return system to desired control mode. Manual/ Automatic Troubleshooting Complete. System should be in field-ready state. 9

Troubleshooting Step 2: Power and Cables Start Lights present on Down Force Module? Are all lights green? Go to Step 5: Indicator Lights Display powered on? Power on Display Are row module lights green? Go to Step 5: Indicator Lights Is CAN A connected? Connect CAN A Does cabling match the Figure 1: Cable Diagram? Correct cabling errors to match Figure 1: Cable Diagram. Check power control relay. Troubleshooting Complete. System should be in field-ready state. 10

Troubleshooting Step 3: Implement Switch Connections NOTE: A minimum of 1 implement switch (2 is recommended) must be installed on planter for the down force system to work properly. If an implement switch is already installed and connected to an existing SeedCommand module, no action is required. If no implement switch is installed, action must be taken to install at least 1 implement switch and implement switch module on local down force CAN Bus. When using the hydraulic down force module with existing Seed Command modules, the implement switch must be connected to the module highest in the hierarchy below: Hydraulic Seed Rate Control Module Clutch Control Module Seed Tube Monitor Module Implement switches connected to any non Seed Command related module will not indicate planter up/down status for Hydraulic Down Force control. (App Rate Module and Liquid Control Module included) If none of the above 3 seed command modules are used then the Hydraulic Down Force module must have a CAN implement switch installed. Part numbers required for CAN implement switch installation: Part Number Description 4002911 Module CAN implement switch 4002658 Cable CAN implement switch 4001507 Implement Switch Implement Switch Kits (contain Implement Switch 4001507) 4100830 Kinze 4100831 John Deere 4100832 White 4100833 Case 11

Troubleshooting Step 4: Hydraulics Start Is Tractor running with hydraulics engaged? Start Tractor and engage hydraulics At the down force control valve, move the red circular manual override knobs to the other position (electronic control override). Is a pressure displayed on the valve s gauge? Move red circular override knobs to the inner position (automatic control). Adjust manual override pressure using allen head adjustment just above the electronic PWM valve. Is pressure still at 0? From the display, Can pressure be released from the system using the down arrow in manual control? From the display, Can pressure be increased in the system using the up arrow in manual control? Ensure Pressure, Return and Tank lines are completely connected. Ensure SCV remote is engaged in the correct direction. Ensure system is set for continuous flow (motor mode). Troubleshooting Complete. System should be in field-ready state. 12

Troubleshooting Step 5: Indicator Lights Light 2 (Proprietary CAN) Light 1 (ISO CAN) Power Power Off Solid Red Flashing Red Solid Amber Flashing Amber Solid Green Flashing Green Boot Power N/A App Running N/A N/A N/A Upgrade Power N/A N/A N/A Running N/A N/A Main Application Power Light 1 (ISO CAN) High Current Power Low N/A N/A N/A Power OK N/A Boot N/A N/A N/A N/A N/A N/A N/A Upgrade Idle Bus Off N/A Bus Error Passive Main Application Light 2 (Proprietary CAN) Idle Bus Off N/A Bus Error Passive Bus Error Active Bus Error Active Boot N/A N/A N/A N/A N/A N/A N/A Upgrade N/A N/A N/A N/A N/A N/A N/A Main Application Idle Bus Off N/A Bus Error Passive Bus Error Active N/A N/A N/A TX/RX TX/RX TX/RX Down Force Row Unit Module Local CAN Off Solid Red Flashing Red Boot N/A N/A Upgrade State Main Application Solid Amber Idle Bus Off N/A Bus Error Passive Flashing Amber Solid Green Flashing Green N/A N/A N/A N/A Bus Error Active N/A CAN OK 13