ELITE Series R-410A - Upflow / Horizontal

Similar documents
ELITE SERIES R-410A Ready - Multi-Position

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

MERIT Series R-410A - Upflow / Horizontal - Variable Speed

DAVE LENNOX SIGNATURE COLLECTION Multi Position Variable Speed Blower

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

Typical Applications. Horizontal Installation

INDOOR COILS CX34. Upflow - Cased - R-410A PRODUCT SPECIFICATIONS. 1.5 to 5 Tons C X A - 6 F MODEL NUMBER IDENTIFICATION FEATURES

T A A 120 S 4 D - 1 M

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

VHIA High-Static Ducted Indoor Units - 60HZ

T-SERIES SPLIT SYSTEM UNITS UPFLOW/HORIZONTAL - R-410A - 60 HZ

Air Handlers. ACBX32CM 3 Phase Multi-Position FEATURES AND BENEFITS. Application. Components. Cabinet. Accessories. Warranty ACBX32CM-100 (07/2011)

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

BCE5E PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS WARRANTY

BCE5V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COILS COMPONENTS ACCESSORIES WARRANTY

ELITE Series R-410A - Two-Stage Compressor

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

BCE3V PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

ELITE COMMERCIAL SPLIT SYSTEMS UPFLOW/HORIZONTAL - R-410A - 60 HZ

ELITE Series R-410A - Two-Stage Compressor

10AC DIPLOMAT SERIES RFC SYSTEMS

HS18 HS18 SERIES CONDENSING UNITS EXPANSION VALVE AIR CONDITIONING SYSTEM. 3.6 to 16.0 kw ( to Btuh) Cooling Capacity ENGINEERING DATA

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACX PRODUCT SPECIFICATIONS

13 HP x

HS17. HS17 SERIES CONDENSING UNITS 17.6 to 65.2 kw ( to Btuh) Cooling Capacity. MATCHED REMOTE SYSTEMS 50hz ENGINEERING DATA

HS22 Bulletin # November 1992 Supersedes September 1990

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION

HS 29. ELITE SERIES SEER up to to 5 Tons Cooling Capacity 12,000 to 62,500 Btuh Bulletin No October 2004 Supersedes September 2003

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 232,000 Btuh AIR CONDITIONERS ELS

TECHNICAL GUIDE SINGLE PIECE STANDARD ECM AIR HANDLERS. DESCRIPTION FEATURE

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

Rheem High Efficiency Air Handler

FORM NO. HSC-543 AIR HANDLERS

2SA13 60HZ P A C K A G E D E L E C T R I C / E L E C T R I C

BCE3 PRODUCT SPECIFICATIONS STANDARD AIR HANDLER APPLICATION INSTALLATION CABINET COMPONENTS ACCESSORIES WARRANTY

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

MERIT SERIES EXPANSION VALVE AND RFC SYSTEMS

ELECTRIC HEAT AIR HANDLERS

VERIFIED ENERGY PERFORMANCE

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHR18 THRU 60* WARRANTY

INSTALLATION INSTRUCTIONS

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

CBH17-95V Horizontal Unit CB V

HMG*T TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

Ruud High Efficiency Air Handler

HMG Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler. 13 SEER Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

G23 Bulletin # September 1998 Supersedes June 1995

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

CHP

T-Class Split System Units R-410A - 50 HZ

B6EMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Rheem High Efficiency Air Handler

HP19 Bulletin No August 1994 Supersedes November 1993

Rheem Air Handlers. RHLP- Standard Efficiency X-13 (ECM) Motor

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

13 GCS X A X Nominal SEER Minor Revision Number

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

B6VMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler with TXV 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

ELITE COMMERCIAL SPLIT SYSTEMS R-410A - 50 HZ. 21 to 70 kw Cooling Capacity to 58.9 kw Models AIR CONDITIONERS ELS EL S 120 S 4 S T 1 M

B6BMMX Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Air Handler Residential System 18,000-60,000 Btuh (Heat Pump & Air Conditioner)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

UARDIAN TECHNICAL GUIDE MODELS: GCGD18 THRU 60

AIR HANDLERS AIR HANDLERS. UHKA- SERIES featuring R-22 Refrigerant UHKL- SERIES featuring Earth-Friendly R-410A Refrigerant.

ARUF Series. Multi-Position, Multi-speed Air Handler with PSC Motor 1½ to 5 Tons. Contents. Product Features

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

Product Data. CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) FMA4P1800AL 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

AVPTC. Multi-Position, Variable-Speed, ECM-Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

P7RE Series Single Packaged Air Conditioner

ZHA/ZHB SERIES WARNING

P7RE Series Single Packaged Air Conditioner

Modular Variable Speed Air Handlers

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R-410A and R-22 SYSTEMS

P5RF Series Single Packaged Air Conditioner Single Phase

Q7RE Series Single Packaged Heat Pump, Single Phase

TECHNICAL GUIDE LISTED TECHNICAL GUIDE SPLIT-SYSTEM AIR CONDITIONERS 13 SEER R-410A 3 PHASE MODELS: TCGD30 THRU 60 (2.5 THRU 5 NOMINAL TONS)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 59,500 Btuh Heating Capacity - 16,900 to 56,000 Btuh

Product Data. FF1E Base Series Fan Coil Sizes 018 thru 036 FEATURES

VT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

Product Data FF1E LEGACY LINE FAN COIL SIZES 018 THRU 037 FEATURES

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY

HP25 HEAT PUMP OUTDOOR UNITS ELITE 12 HEAT PUMP OUTDOOR UNITS

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

JT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency Heat Pump 14 SEER Residential System 1.

TECHNICAL GUIDE DESCRIPTION

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

XC21. DAVE LENNOX SIGNATURE COLLECTION R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

MB6(B,E,V)M Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Modular Indoor Blower 13+ SEER Residential System. Additional MB6EM Features:

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

S-CLASS SPLIT SYSTEM R-410A - Two-Stage Compressor - 60 HZ

BCS2S. Product Specifications ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS ACCESSORIES.

BCS2**V. Enhanced Air Handler APPLICATION INSTALLATION CABINET ACCESSORIES COMPONENTS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

Transcription:

PRODUCT SPECIFICATIONS AIR HANDLERS CBX7UH ELITE Series R-0A - Upflow / Horizontal Bulletin No. 08 March 0 Supersedes October 0 Nominal Capacity -. to Tons Optional Electric Heat -. to kw MODEL NUMBER IDENTIFICATION CB X 7 UH - 06-0 - 6-0 Unit Type CB = Air Handler Refrigerant Type X = R-0A Series Configuration UH = Upflow/Horizontal Nominal Cooling Capacity - Tons 08 =. tons 0 = tons 00 =. tons 06 = tons 0 =. tons 08 = tons 060 = tons Minor Revision Number Refrigerant Metering Device = Fixed Orifice = TXV - Bleedport (indoor unit) = TXV - Non-bleedport (indoor unit) = TXV - Non-bleedport (outdoor unit) 6 = TXV - R-0A Non-bleedport (indoor unit) Voltage 0 = 08/0V- phase-60hz 60 = 60V- phase-60hz Can be used with 7V (step-down transformer required)

FEATURES CONTENTS Blower Data... 8 Dimensions... Electrical Data... 6 Electric Heat Data... 0 Features... Installation Clearances With Electric Heat... Model Number Identification... Optional Accessories... 6 Replacement Breakers... 9 Specifications... 6 F H B E G WARRANTY All covered components - five years in residential applications, one year in non-residential applications Refer to Lennox Limited Warranty Certificate included with each unit for additional details. APPROVALS Tested with matching air conditioners and heat pump units in the Lennox Research Laboratory environmental test room in accordance with AHRI Standard 0/0. Optional electric heaters are rated in accordance with US Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations. Blower performance data according to unit tests conducted in Lennox air test chamber. Air handlers are UL Listed to US and Canadian safety standards and components within are bonded for grounding to meet safety standards for servicing required by CEC and NEC. Air handler units are approved for installation in manufactured housing and mobile homes. ISO 900 Registered Manufacturing Quality System. APPLICATIONS. to ton nominal sizes. Upflow or horizontal applications. Downflow applications with optional conversion kit. Applicable to expansion valve systems in cooling applications and check and expansion valve systems in heat pump applications. Wide-range check and expansion valve is factory installed. See bulletins in section Air Conditioners for cooling capacities. See bulletins in section Heat Pump Outdoor Units for cooling and heating capacities. Optional field installed electric heaters available in several sizes for additive heating capacity. CBX7UH / Page B C D I D REFRIGERANT SYSTEM C Copper Tube/Enhanced Fin Indoor Coil Lennox designed and fabricated twin coils. Assembled in A configuration. Provides extra large surface and contact area, excellent heat transfer and low air resistance for maximum efficiency. Precise circuiting for uniform refrigerant distribution. Precisely spaced ripple-edged aluminum fins fitted to durable seamless copper tubes. Fins are strengthened to resist bending and are equipped with collars that grip tubing for maximum contact area. Lanced fins provide maximum exposure of fin surface to air stream. Long life copper tubing is easy to service. Rifled tubing provides superior heat transfer. Flared shoulder tubing joints and silver soldering provide tight, leakproof joints. Coil thoroughly factory tested under high pressure to ensure leakproof construction. Refrigerant Line Connections Suction (vapor) and liquid lines have sweat connections that extended outside of the cabinet for ease of connection. See dimension drawings for locations. Check and Expansion Valve Furnished For use with R-0A systems. Wide range valve with Chatleff style fitting. Factory installed on all models, internal to cabinet.

E F G FEATURES BLOWER Programmable Multi-Speed Blower Motor Programmable high efficiency multi-speed blower motor. By maintaining constant torque output, blower motor can deliver more uniform (but not constant) airflow over the static pressure range. Programmable multi-speed operation is achieved by the use of an ECM (Electronically Commutated Motor) motor. Leadless blower motor features simple plug-in connections. Choice of blower speeds is available. See Blower Data tables. Blower speed change is easily accomplished by a simple wiring change. Blower Assembly Lennox designed and built, direct drive blower. Each blower is statically and dynamically balanced as an assembly before installation in the unit. Blower motor is resiliently mounted to blower assembly. Blower slides out of cabinet for servicing. CABINET Constructed of heavy-gauge galvanized steel. Completely insulated with thick fiberglass insulation. Pre-painted steel cabinets have mildly textured enamel finish with primer coat on unpainted side of all panels. Units are shipped in one piece but may be disassembled into two separate sections for ease of installation in tight applications. See dimension drawings. Thick rubber gasket between sections of the two piece cabinets provides an air tight seal. No external screw heads on sides of cabinet for tight installations without damage to walls or woodwork. Removable panels provide complete service access. Electrical inlets provided in sides and top of cabinet. See dimension drawings for locations. Dual Position Drain Pans Drain pans designed for upflow, downflow or horizontal applications. Deep, corrosion resistant plastic drain pans have dual pipe drains. See dimension drawings. Optional Accessories Downflow Combustible Flooring Floor Base Base is required for models with electric heat installed in downflow position on combustible floors. Downflow Conversion Kit Required for field conversion to downflow position. Kit consists of drip shields and brackets for repositioning coil and drain pan. See Specifications table. Horizontal Support Frame Kit Provides support of unit in horizontal applications. Consists of () x -/ x -/8 in. and () x x -7/8 in. painted heavy gauge cold rolled steel support channels with assembly and suspending holes. Bolts and nuts furnished for field assembly. Suspending rods must be field provided. Side Return Unit Stand (Upflow Only) Raises unit 6 in. above floor for side return air duct connection. Eliminates need for wooden platform construction. All aluminum construction. Two adjustable frames fit -08/0 thru -060 models. Wall Hanging Bracket Kit (Upflow Only) Allows unit to be hung on wall at any height. Consists of heavy-gauge steel support brackets (one for air handler, one for wall mount). Screws furnished for fastening one bracket to unit. Bolts for fastening one bracket to wall are field provided. Low Leakage Cabinet All models have less than % air leakage and meet ANSI/ASHRAE Standard 9-00 Method of Test for Determining the Air Tightness of HVAC Equipment. Upflow/Horizontal Capability (Optional Downflow) Shipped for upflow and horizontal left-hand discharge. May be field converted to horizontal right-hand air discharge by repositioning horizontal drain pan. Optional downflow kit available for field conversion. CBX7UH / Page

FEATURES CONTROLS Transformer and Blower Cooling Relay volt transformer with in-line fuse and blower cooling relay furnished as standard. Factory installed in the unit control box. Terminal strip furnished. Optional Accessories ComfortSense 7000 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, HOME SCHEDULE OPTIONS touchscreen thermostat. SET AT Heat/ Cool. Auto-changeover. Controls humidity during cooling mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. Remote outdoor temperature sensor (optional) allows the thermostat to display outdoor temperature. Required in dual fuel and Humiditrol applications. See the ComfortSense 7000 Product Specifications bulletin in the Controls section for more information. Dehumidification Relay Kit Required with ComfortSense thermostat. Provides dehumidification mode when used in conjunction with ComfortSense 7000 thermostat. Used with single- or two-stage heat pumps and air conditioners. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. CBX7UH / Page MODE SCHED AUTO ON INDOOR RH 6% WED AN :AM HEAT SET AT COOL H OPTIONAL ELECTRIC HEAT Field install internal to unit cabinet. Available in several voltages and kw sizes. See Electric Heat tables. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Each element equipped with accurately located limit control with fixed temperature off setting and automatic reset. Supplemental thermal cutoff limit control, provides positive protection in case of excessive temperatures. Thermal sequencer relay brings elements on and off line, in sequence and equal increments, with time delay between each. Initiates and terminates blower operation. Heating control relay(s) furnished as standard. Control box and access cover constructed of heavy gauge galvanized steel. Factory assembled with controls installed and wired. Electric heat low voltage controls plug-in to air handler. Breaker Models ECB9-CB, -CB, -6CB, -8CB, -9CB, -0CB, -.CB, -CB, -0CB, -CB and -0CB (08/0V-ph) and ECB9-CB, -0CB and -CB (08/0V-ph) heaters are equipped with circuit breakers for overload and short circuit protection. Factory wired and mounted on electric heat unit. Current sensitive and temperature actuated. Manual reset. breakers qualify as disconnect means at unit in many areas, eliminate the need for field provided disconnect. Consult local electrical code in your area. NOTE - 60V- phase air handlers can be used in 7V applications. 7V electric heaters are shipped with a 7V to 60V step-down transformer. Optional Accessories Breaker Cover Kit Flexible plastic cover protects circuit breaker. Recommended in areas with high humidity or unconditioned areas to prevent nuisance tripping. Single-Point Power Source Control Box Control Box may be used with optional electric heat when single power supply is connected to multi-circuit electric heat. Field installs external to the unit cabinet on either side or top. Constructed of heavy gauge steel, baked enamel finish, prepunched mounting holes, electrical inlet knockouts, and terminal strip. Removable cover provides easy access. Dimensions (H x W x D) - 7 x 7 x in.

I FEATURES INDOOR AIR QUALITY Air Filter Tool-less access to filter area for quick and easy servicing. Disposable frame type filter furnished and factory installed in rails in cabinet. See Specifications tables for sizes. Optional Accessories Healthy Climate Germicidal UVC Light Germicidal lamp emits C-Band ultra-violet (UVC) energy at.7 nanometers, which is proven to be effective in reducing microbes such as viruses, bacteria, yeasts, and molds. This process either destroys the organism or controls its ability to reproduce. UVC germicidal light greatly reduces the growth and proliferation of mold and other bioaerosols (bacteria and viruses) on illuminated surfaces (particularly coil and drain pan). Surfaces must be cleaned prior to UVC light being installed. Available in volt and 0.0V-ph models. Air handlers have a factory provided knockout in the coil delta plate for mounting light within coil area. Shielding baffle is required when installing light above a non-uvc resistant component, such as a filter. Baffle must be ordered separately. INSTALLATION CLEARANCES WITH ELECTRIC HEAT Cabinet 0 inch (0 mm) To Plenum inch ( mm) To Outlet Duct within feet (9 mm) inch ( mm) Floor See Note # Service / Maintenance See Note # Units installed on combustible floors in the downflow position with electric heat require optional downflow combustible flooring base. Front service access - inches (60 mm) minimum. NOTE - If cabinet depth is more than inches (60 mm), allow a minimum of the cabinet depth plus inches ( mm). CBX7UH / Page

SPECIFICATIONS General Data Model Number CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 Nominal tonnage.. Connections Suction (vapor) line (o.d.) - in. sweat / / / / Liquid line (o.d.) - in. sweat /8 /8 /8 /8 Condensate - in. fpt () / () / () / () / Indoor Coil Net face area - ft....0.0 Tube outside diameter - in. /8 /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. 0 x 8 0 x 8 x 8 x 8 Blower motor output - hp / / / / Filters Size of filter - in. 0 x 0 x 0 x 0 x 0 x 0 x 0 x 0 x Shipping Data - package - lbs. 8 8 9 9 ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V-ph 08/0V-ph 08/0V-ph Voltage - phase - 60hz - - - - - - - - - 60V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V Blower Motor Full Load Amps - 08/0V.... circuit ampacity (unit only) - 60V - - - - - - - - -.6 Blower Motor Full Load Amps - 60V - - - - - - - - -. OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 7000 Thermostat Y08 Y08 Y08 Y08 Remote Outdoor Temperature Sensor (for ComfortSense 7000) X68 X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K K Downflow Conversion Kit 8M7 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables. to 0 kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K K Single Point Power Source Control Box H9 H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBX7UH / Page 6

SPECIFICATIONS General Data Model Number CBX7UH-0 CBX7UH-08 CBX7UH-060 Nominal tonnage. Connections Suction (vapor) line (o.d.) - in. sweat 7/8 7/8 7/8 Liquid line (o.d.) - in. sweat /8 /8 /8 Condensate - in. fpt () / () / () / Indoor Coil Net face area - ft. 7. 7. 8. Tube outside diameter - in. /8 /8 /8 Number of rows Fins per inch Blower Wheel nominal diameter x width - in. x 9 x 9 x 9 Blower motor output - hp Filters Size of filter - in. 0 x x 0 x x 0 x x Shipping Data - package lbs. 9 9 6 ELECTRICAL DATA Voltage - phase - 60hz 08/0V-ph 08/0V- ph 08/0V- ph Voltage - phase - 60hz - - - 60V-ph 60V-ph overcurrent protection (unit only) - All voltages circuit ampacity (unit only) - 08/0V 0 0 0 Blower Motor Full Load Amps - 08/0V 7.6 7.6 7.6 circuit ampacity (unit only) - 60V - - - Blower Motor Full Load Amps - 60V - - - OPTIONAL ACCESSORIES - ORDER SEPARATELY ComfortSense 7000 Thermostat Y08 Y08 Y08 Remote Outdoor Temperature Sensor (for ComfortSense 7000) X68 X68 X68 Dehumidification Relay Kit 6W6 6W6 6W6 Downflow Combustible Flooring Base K K K Downflow Conversion Kit 8M7 8M7 8M7 Electric Heat - See Electric Heat Data tables to kw Electric Heat Breaker Cover Kit 8W0 8W0 8W0 Healthy Climate Germicidal Light UVC-V (V) X9 X9 X9 Shielding Baffle (required) Y0 Y0 Y0 UVC-W-S (0/0v- ph) X9 X9 X9 Shielding Baffle (required) X9900 X9900 X9900 Horizontal Support Frame Kit 6J8 6J8 6J8 Side Return Unit Stand (Upflow Only) K K K Single Point Power Source Control Box H9 H9 H9 Wall Hanging Bracket Kit (Upflow Only) K0 K0 K0 Disposable frame type filter. HACR type circuit breaker or fuse. Blower motor is 60V - phase. Optional electric heat is 60V - phase. CBX7UH / Page 7

BLOWER DATA CBX7UH-08 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 8 80 80 77 8 86 8 89 00 7 80 8 8 77 8 8 80 9 00 0.0 70 7 700 68 7 76 790 89 980 70 7 7 7 7 77 79 89 97.0 80 9 60 8 66 76 7 99 90 70 9 80 60 660 77 7 99 90.0 00 6 0 60 78 70 0 90 7 0 6 0 8 6 80 7 0 90 60.0 00 6 0 9 80 87 68 870 66 67 60 7 89 680 87 70.0 6 7 90 60 0 96 60 8 76 77 00 6 0 99 60 8 80 79.60 7 80 68 00 80 800 79 0 77 70 7 0 0 7 9 80 8.70 N/A N/A 0 7 90 0 8 7 87 N/A N/A 0 7 9 06 7 780 9.80 N/A N/A 70 7 09 70 6 70 9 N/A N/A 7 76 6 8 7 00 CBX7UH-0 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 88 89 88 89 90 97 0 0 8 8 890 9 89 90 90 99 00 0 90 89.0 7 77 760 77 80 98 99 9 0 9 78 8 770 78 8 00 000 00.0 66 7 670 7 80 06 970 8 00 0 67 76 670 76 80 960 0 07.0 60 77 600 77 77 90 070 60 80 60 80 780 90 6 08 9.0 60 8 88 7 88 6 0 9 70 88 88 7 890 66 0.0 9 9 67 8 7 000 8 6 99 6 99 670 80 7 00.60 00 98 9 96 70 7 80 79 960 0 0 0 0 9 8 8 97 6.70 N/A N/A 0 0 70 9 90 N/A N/A 0 06 0 70 97 9 8.80 N/A N/A 0 06 60 8 6 0 8 N/A N/A 0 8 660 07 89 60 CBX7UH-00 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 0 8 7 0 8 70 77 08 0 80 6 80 79 6.0 0 8 06 6 0 0 8 9 00 8 08 0 8.0 90 0 90 0 60 0 9 0 9 0 9 6 0 6 0 9 0 7.0 70 89 870 7 00 69 6 0 0 8 7 9 88 8 060 7 70 07 6.0 60 9 8 0 00 76 09 0 8 6 9 80 00 80 0.0 0 0 7 6 980 8 08 8 80 7 0 0 7 6 98 8 090 9 6.60 70 06 670 90 9 0 0 6 7 07 670 9 9 9 00 0 70.70 N/A N/A 60 8 07 99 0 7 N/A N/A 60 9 860 00 0 80.80 N/A N/A 9 78 7 90 0 8 N/A N/A 60 6 80 9 8 00 9 CBX7UH-06 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 8 6 9 0 8 0 9 80 9 0 0 9 0 8 99.0 070 7 80 96 9 0 08 9 9 0 0 0.0 960 00 0 0 0 60 7 9 0 60 6 6 8.0 8 0 970 6 9 0 6 0 80 0 97 0 9 0 7 7.0 70 06 9 8 7 7 8 770 90 70 8 8 0.0 670 9 870 0 0 8 670 8 870 9 0 0 9 6 7.60 60 0 8 6 060 90 90 60 80 7 080 9 0 07 0 67.70 7 7 77 0 0 70 9 6 7 8 00 60 60 8 78.80 670 8 970 6 00 69 6 67 9 980 76 0 9 CBX7UH / Page 8

BLOWER DATA CBX7UH-0 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 7 98 0 8 60 70 9 80 9 7 00 0 6 70 00 8 0.0 70 8 0 07 660 07 780 6 60 8 07 66 0 77 68.0 7 0 89 66 6 70 78 7 0 90 69 60 6 70 8.0 090 0 00 70 78 600 6 70 90 090 0 70 78 60 7 9.0 00 6 90 0 0 9 60 6 68 07 00 6 00 0 00 6 680 08.0 9 77 8 0 0 7 60 8 9 78 0 9 8 0 7 60 0.60 88 8 090 0 9 7 8 90 9 8 09 0 80 90 9.70 N/A N/A 00 8 0 0 6 7 N/A N/A 000 6 0 08 6 68.80 N/A N/A 990 60 00 6 9 0 7 N/A N/A 000 00 6 7 9 8 CBX7UH-08 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 0 00 670 0 690 80 0 0 7 680 09 700 9 860.0 70 88 60 8 670 9 8 70 89 6 66 68 80.0 60 7 6 7 660 7 8 6 77 60 67 80.0 0 66 80 60 60 800 7 67 80 6 9 6 8 8 6.0 0 7 60 6 9 67 770 6 0 77 6 8 8 60 7 780 7.0 960 90 9 7 0 7 77 7 79 970 9 90 78 78 70 8 7 90.60 89 9 0 8 90 89 0 0 69 89 890 0 0 96 00 96 08 70 06.70 N/A N/A 0 07 70 8 60 N/A N/A 0 08 90 66.80 N/A N/A 09 7 8 6 0 60 0 N/A N/A 07 0 0 60 CBX7UH-060 BLOWER PERFORMANCE External Air Volume and Motor Watts at 08V Air Volume and Motor Watts at 0V / 60V Static Tap Tap Tap Tap Tap Tap Tap Tap Tap Tap Pressure in. w.g. cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts.00 90 07 76 970 00 9 6 799 0 77 7 980 6 0 97 6 8.0 9 9 70 90 66 98 07 8 80 00 98 7 90 7 990 89.0 0 9 700 900 80 9 00 87 96 70 6 90 90 96 0 80.0 7 06 670 67 87 87 9 6 8 70 67 7 890 07 90 0 8 86.0 0 60 78 8 0 890 80 0 6 90 80 6 90 6 88.0 70 6 7 9 79 9 80 0 86 8 90 0 8 87 7 89.60 09 70 9 80 69 7 87 0 9 9 78 0 8 8 90 908.70 N/A N/A 90 7 70 77 8 88 N/A N/A 0 6 7 6 79 60 9.80 N/A N/A 70 9 68 7 70 9 08 89 N/A N/A 80 700 7 760 69 0 90 REPLACEMENT CIRCUIT BREAKERS Voltage Description Catalog No. amp, pole K 0 amp, pole 7K70 amp, pole 7K07 08/0V - Phase 0 amp, pole 9K amp, pole 7K7 0 amp, pole K 60 amp, pole 7K7 0 amp, pole 6W7 amp, pole K 08/0V - Phase 0 amp, pole K6 amp, pole 8M86 0 amp, pole K 60 amp, pole K7 CBX7UH / Page 9

ELECTRIC HEAT DATA - CBX7UH-08 Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps SINGLE PHASE. kw lbs. kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9-. (L7) ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker 08.9 6,00. 6 0 0. 7,00. 8 0 0. 7,800. 8 0 0. 8,00. 8 0 08.0 0,0. 0.,0. 6 0 0.7,0. 6 0 0.0,60. 6 0 08.8,800. 8 0 0.,00. 0.6,700. 0.0 7,00. 08.,00. 0.0 7,00. 6 0 0. 8,800. 6 0 0 6.0 0,00. 6 0 08 6.0 0,00. 0 6.7,900. 7 0 0 7.,00. 7 0 0 8.0 7,00. 7 0 08 6.8,00. 6 0 0 7.6,800. 60 0 8. 8,00. 60 0 9.0 0,700. 60 08 7.,600. 0 0 0 8. 8,700. 7 60 0 9.,00. 7 60 0 0.0,00. 7 60 NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 0

ELECTRIC HEAT DATA - CBX7UH-0 Model Number No. of Stages Input Volts kw Btuh Blower Motor Full Load Amps SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs. ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker 08.0 0,0. 0.,0. 6 0 0.7,0. 6 0 0.0,60. 6 0 08.8,800. 8 0 0.,00. 0.6,700. 0.0 7,00. 08.,00. 0.0 7,00. 6 0 0. 8,800. 6 0 0 6.0 0,00. 6 0 08 6.0 0,00. 0 6.7,900. 7 0 0 7.,00. 7 0 0 8.0 7,00. 7 0 08 6.8,00. 6 0 0 7.6,800. 60 0 8. 8,00. 60 0 9.0 0,700. 60 08 7.,600. 0 0 0 8. 8,700. 7 60 0 9.,00. 7 60 0 0.0,00. 7 60 NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

ELECTRIC HEAT DATA - CBX7UH-00 Model Number SINGLE PHASE kw ECB9- (L0) lbs. ECB9-CB (L) 0A breaker kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker ECB9-.CB (L) () A breaker & () 0A breaker ECB9-CB (L6) () 0A breaker & () 60A Breaker ECB9-8 (L6) ECB9-0 (L6) ECB9-CB (L6) () 0A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08.0 0,0. - - - - - - - - - - - - 0.,0. 6 - - - 0 - - - - - - - - - 0.7,0. 6 - - - 0 - - - - - - - - - 0.0,60. 6 - - - 0 - - - - - - - - - 08.8,800. 8 - - - 0 - - - - - - - - - 0.,00. - - - - - - - - - - - - 0.6,700. - - - - - - - - - - - - 0.0 7,00. - - - - - - - - - - - - 08.,00. - - - - - - - - - - - - 0.0 7,00. 6 - - - 0 - - - - - - - - - 0. 8,800. 6 - - - 0 - - - - - - - - - 0 6.0 0,00. 6 - - - 0 - - - - - - - - - 08 6.0 0,00. - - - - - - - - - - - - 0 6.7,900. 7 - - - 0 - - - - - - - - - 0 7.,00. 7 - - - 0 - - - - - - - - - 0 8.0 7,00. 7 - - - 0 - - - - - - - - - 08 6.8,00. 6 - - - 0 - - - - - - - - - 0 7.6,800. - - - 60 - - - - - - - - - 0 8. 8,00. - - - 60 - - - - - - - - - 0 9.0 0,700. - - - 60 - - - - - - - - - 08 7.,600. 0 - - - 0 - - - - - - - - - 0 8. 8,700. 7 - - - 60 - - - - - - - - - 0 9.,00. 7 - - - 60 - - - - - - - - - 0 0.0,00. 7 - - - 60 - - - - - - - - - 08 9.,000. 8 0 6 70 0 0.,800. 7 0 70 70 0. 9,00. 7 0 70 70 0.,600. 7 0 70 70 08. 8,00. 8 0 7 80 0.6,000. 60 8 90 0.8 7,000. 60 8 90 0.0,00. 60 8 90 08 6.0 0,00. 6 - - - 0 - - - - - - - - - 0 6.7,900. 9 - - - 0 - - - - - - - - - 0 7.,00. 9 - - - 0 - - - - - - - - - 0 8.0 7,00. 9 - - - 0 - - - - - - - - - 08 7.,600. - - - - - - - - - - - - 0 8. 8,700. - - - - - - - - - - - - 0 9.,00. - - - - - - - - - - - - 0 0.0,00. - - - - - - - - - - - - 08. 8,00. - - - - - - - - - - - - 0.6,000. 0 - - - 0 - - - - - - - - - 0. 7,000. 0 - - - 0 - - - - - - - - - 0.0,00. 0 - - - 0 - - - - - - - - - Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

ELECTRIC HEAT DATA - CBX7UH-06 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs. 0 kw 6 lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-0 (L) ECB9-0CB (L) 60A breaker ECB9-.CB (L) () A breaker and () 0A breaker ECB9-CB (L6) () 0A breaker and () 60A Breaker ECB9-0CB (L8) () 0A breaker and () 60A Breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08.0 0,0. - - - - - - - - - - - - 0.,0. 6 - - - 0 - - - - - - - - - 0.7,0. 6 - - - 0 - - - - - - - - - 0.0,60. 6 - - - 0 - - - - - - - - - 08.8,800. 8 - - - 0 - - - - - - - - - 0.,00. - - - - - - - - - - - - 0.6,700. - - - - - - - - - - - - 0.0 7,00. - - - - - - - - - - - - 08.,00. - - - - - - - - - - - - 0.0 7,00. 6 - - - 0 - - - - - - - - - 0. 8,800. 6 - - - 0 - - - - - - - - - 0 6.0 0,00. 6 - - - 0 - - - - - - - - - 08 6.0 0,00. - - - - - - - - - - - - 0 6.7,900. 7 - - - 0 - - - - - - - - - 0 7.,00. 7 - - - 0 - - - - - - - - - 0 8.0 7,00. 7 - - - 0 - - - - - - - - - 08 6.8,00. 6 - - - 0 - - - - - - - - - 0 7.6,800. - - - 60 - - - - - - - - - 0 8. 8,00. - - - 60 - - - - - - - - - 0 9.0 0,700. - - - 60 - - - - - - - - - 08 7.,600. 0 - - - 0 - - - - - - - - - 0 8. 8,700. 7 - - - 60 - - - - - - - - - 0 9.,00. 7 - - - 60 - - - - - - - - - 0 0.0,00. 7 - - - 60 - - - - - - - - - 08 9.,000. 8 0 6 70 0 0.,800. 7 0 70 70 0. 9,00. 7 0 70 70 0.,600. 7 0 70 70 08. 8,00. 8 0 7 80 0.6,000. 60 8 90 0.8 7,000. 60 8 90 0.0,00. 60 8 90 08.0,00. 6 0 0 0 96 00 0 6.8 7,00. 7 60 60 09 0 8. 6,700. 7 60 60 09 0 0.0 68,00. 7 60 60 09 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

ELECTRIC HEAT DATA - CBX7UH-06 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. Model Number ECB9-8 (L6) ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) () 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08 6.0 0,00. 6 - - - 0 - - - - - - - - - 0 6.7,900. 9 - - - 0 - - - - - - - - - 0 7.,00. 9 - - - 0 - - - - - - - - - 0 8.0 7,00. 9 - - - 0 - - - - - - - - - 08 7.,600. - - - - - - - - - - - - 0 8. 8,700. - - - - - - - - - - - - 0 9.,00. - - - - - - - - - - - - 0 0.0,00. - - - - - - - - - - - - 0 8. 8,700. 6 - - - 0 - - - - - - - - - 60 9.,00. 7 - - - 0 - - - - - - - - - 80 0.0,00. 7 - - - 0 - - - - - - - - - 08. 8,00. - - - - - - - - - - - - 0.6,000. 0 - - - 0 - - - - - - - - - 0. 7,000. 0 - - - 0 - - - - - - - - - 0.0,00. 0 - - - 0 - - - - - - - - - 0.6,000. - - - - - - - - - - - - 60. 7,000. - - - - - - - - - - - - 80.0,00. - - - 0 - - - - - - - - - 08.0,00. 6 0 7 60 0 6.8 7,00. 0 0 6 70 0 8. 6,700. 0 0 6 70 0 0.0 68,00. 0 0 6 70 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

ELECTRIC HEAT DATA - CBX7UH-0 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. No. Volts kw Model Number of Input Input Stages ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker 60A breaker ECB9-.CB (L) () A breaker and () 0A breaker ECB9-CB (L6) () 0A breaker and () 60A breaker ECB9-0CB (L8) () 0A breaker and () 60A breaker ECB9-CB (L9) () 0A breakers Btuh Input Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source 08.0 0,0 7.6 8 - - - - - - 0 - - - - - - - - - - - - 0.,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.7,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.0,60 7.6 0 - - - - - - 0 - - - - - - - - - - - - 08.8,800 7.6 - - - - - - - - - - - - - - - - - - 0.,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.6,700 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 08.,00 7.6 7 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 - - - - - - - - - - - - - - - - - - 0. 8,800 7.6 - - - - - - - - - - - - - - - - - - 0 6.0 0,00 7.6 - - - - - - - - - - - - - - - - - - 08 6.0 0,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0 6.7,900 7.6 - - - - - - 60 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - 60 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - 60 - - - - - - - - - - - - 08 6.8,00 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0 7.6,800 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 8. 8,00 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 9.0 0,700 7.6 6 - - - - - - 60 - - - - - - - - - - - - 08 9.,000 7.6 8 8 - - - 0 0 - - - 66 80 0 0.,800 7.6 - - - - - - 7 80 0. 9,00 7.6 - - - - - - 7 80 0.,600 7.6 - - - - - - 7 80 08. 8,00 7.6 - - - - - - 77 80 0.6,000 7.6 6 - - - 0 60 - - - 88 90 0. 7,000 7.6 6 - - - 0 60 - - - 88 90 0.0,00 7.6 6 - - - 0 60 - - - 88 90 08.0,00 7.6 0 0 - - - 0 0 - - - 00 0 6.8 7,00 7.6 6 7 - - - 60 60 - - - 0 8. 6,700 7.6 6 7 - - - 60 60 - - - 0 0.0 68,00 7.6 6 7 - - - 60 60 - - - 08 8.8 6,00 7.6 7 8 8 0 0 0 0.0 7,700 7.6 60 0 0 0.0 78,00 7.6 60 0 0 0.0 8,00 7.6 60 0 0 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page

ELECTRIC HEAT DATA - CBX7UH-0 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08 6.0 0,00 7.6 0 - - - 0 - - - - - - - - - 0 6.7,900 7.6 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - - - - - - - 08 7.,600 7.6 6 - - - 0 - - - - - - - - - 0 8. 8,700 7.6 0 - - - 0 - - - - - - - - - 0 9.,00 7.6 0 - - - 0 - - - - - - - - - 0 0.0,00 7.6 0 - - - 0 - - - - - - - - - 0 8. 8,700 - - - - - - - - - - - - - - - - - - - - - 60 9.,00 - - - - - - - - - - - - - - - - - - - - - 80 0.0,00 - - - - - - - - - - - - - - - - - - - - - 08. 8,00 7.6 9 - - - 0 - - - - - - - - - 0.6,000 7.6 - - - 60 - - - - - - - - - 0. 7,000 7.6 - - - 60 - - - - - - - - - 0.0,00 7.6 - - - 60 - - - - - - - - - 0.6,000 - - - - - - - - - - - - - - - - - - - - - 60. 7,000 - - - - - - - - - - - - - - - - - - - - - 80.0,00 - - - - - - - - - - - - - - - - - - - - - 08.0,00 7.6 6 6 0 0 6 70 0 6.8 7,00 7.6 0 0 0 0 70 70 0 8. 6,700 7.6 0 0 0 0 70 70 0 0.0 68,00 7.6 0 0 0 0 70 70 0 6.8 7,00 - - - - - - - - - - - - - - - - - - - - - 60 8. 6,700 - - - - - - - - - - - - - - - - - - - - - 80 0.0 68,00 - - - - - - - - - - - - - - - - - - - - - 0 6.8 7,00 - - - - - - - - - - - - - - - - - - - - - 7 8. 6,700 - - - - - - - - - - - - - - - - - - - - - 600 0.0 68,00 - - - - - - - - - - - - - - - - - - - - - 08 8.8 6,00 7.6 0 6 70 0.0 7,700 7.6 7 8 0 0 8 90 0.0 78,00 7.6 7 8 0 0 8 90 0.0 8,00 7.6 7 8 0 0 8 90 0.0 7,700 - - - - - - - - - - - - - - - - - - - - - 60.0 78,00 - - - - - - - - - - - - - - - - - - - - - 80.0 8,00 - - - - - - - - - - - - - - - - - - - - - 0.0 7,700 - - - - - - - - - - - - - - - - - - - - - 7.0 78,00 - - - - - - - - - - - - - - - - - - - - - 600.0 8,00 - - - - - - - - - - - - - - - - - - - - - Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 6

ELECTRIC HEAT DATA - CBX7UH-08 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-.CB (L) (9K68) () A breaker & () 0A breaker ECB9-CB (L6) () 0A breaker & () 60A breaker ECB9-0CB (L8) () 0A breaker & () 60A breaker ECB9-CB (L9) () 0A breakers No. of Stages Input Blower Motor Full Load Amps NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source 08.0 0,0 7.6 8 - - - - - - 0 - - - - - - - - - - - - 0.,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.7,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.0,60 7.6 0 - - - - - - 0 - - - - - - - - - - - - 08.8,800 7.6 - - - - - - - - - - - - - - - - - - 0.,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.6,700 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 08.,00 7.6 7 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 - - - - - - - - - - - - - - - - - - 0. 8,800 7.6 - - - - - - - - - - - - - - - - - - 0 6.0 0,00 7.6 - - - - - - - - - - - - - - - - - - 08 6.0 0,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0 6.7,900 7.6 - - - - - - 60 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - 60 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - 60 - - - - - - - - - - - - 08 6.8,00 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0 7.6,800 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 8. 8,00 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 9.0 0,700 7.6 6 - - - - - - 60 - - - - - - - - - - - - 08 9.,000 7.6 8 8 - - - 0 0 - - - 66 80 0 0.,800 7.6 - - - - - - 7 80 0. 9,00 7.6 - - - - - - 7 80 0.,600 7.6 - - - - - - 7 80 08. 8,00 7.6 - - - - - - 77 80 0.6,000 7.6 6 - - - 0 60 - - - 88 90 0. 7,000 7.6 6 - - - 0 60 - - - 88 90 0.0,00 7.6 6 - - - 0 60 - - - 88 90 08.0,00 7.6 0 0 - - - 0 0 - - - 00 0 6.8 7,00 7.6 6 7 - - - 60 60 - - - 0 8. 6,700 7.6 6 7 - - - 60 60 - - - 0 0.0 68,00 7.6 6 7 - - - 60 60 - - - 08 8.8 6,00 7.6 7 8 8 0 0 0 0.0 7,700 7.6 60 0 0 0.0 78,00 7.6 60 0 0 0.0 8,00 7.6 60 0 0 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 7

ELECTRIC HEAT DATA - CBX7UH-08 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08 6.0 0,00 7.6 0 - - - 0 - - - - - - - - - 0 6.7,900 7.6 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - - - - - - - 08 7.,600 7.6 6 - - - 0 - - - - - - - - - 0 8. 8,700 7.6 0 - - - 0 - - - - - - - - - 0 9.,00 7.6 0 - - - 0 - - - - - - - - - 0 0.0,00 7.6 0 - - - 0 - - - - - - - - - 0 8. 8,700.0 8 - - - 0 - - - - - - - - - 60 9.,00.0 9 - - - 0 - - - - - - - - - 80 0.0,00.0 0 - - - - - - - - - - - - 08. 8,00 7.6 9 - - - 0 - - - - - - - - - 0.6,000 7.6 - - - 60 - - - - - - - - - 0. 7,000 7.6 - - - 60 - - - - - - - - - 0.0,00 7.6 - - - 60 - - - - - - - - - 0.6,000.0 - - - 0 - - - - - - - - - 60. 7,000.0 6 - - - 0 - - - - - - - - - 80.0,00.0 7 - - - 0 - - - - - - - - - 08.0,00 7.6 6 6 0 0 6 70 0 6.8 7,00 7.6 0 0 0 0 70 70 0 8. 6,700 7.6 0 0 0 0 70 70 0 0.0 68,00 7.6 0 0 0 0 70 70 0 6.8 7,00.0 - - - - - - - - - - - - 60 8. 6,700.0 - - - - - - - - - - - - 80 0.0 68,00.0 - - - 0 - - - - - - - - - 0 6.8 7,00.0 7 - - - 0 - - - - - - - - - 7 8. 6,700.0 8 - - - 0 - - - - - - - - - 600 0.0 68,00.0 9 - - - 0 - - - - - - - - - 08 8.8 6,00 7.6 0 7 80 0.0 7,700 7.6 7 8 0 0 8 90 0.0 78,00 7.6 7 8 0 0 8 90 0.0 8,00 7.6 7 8 0 0 8 90 0.0 7,700.0 9 - - - 0 - - - - - - - - - 60.0 78,00.0 - - - - - - - - - - - - 80.0 8,00.0 - - - - - - - - - - - - 0.0 7,700.0 - - - - - - - - - - - - 7.0 78,00.0 - - - - - - - - - - - - 600.0 8,00.0 - - - 0 - - - - - - - - - Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 8

ELECTRIC HEAT DATA - CBX7UH-060 SINGLE PHASE kw lbs. kw lbs. 6 kw lbs. 8 kw lbs. 9 kw lbs.. kw 0 lbs. Model Number ECB9- (L0) ECB9-CB (L) 0A breaker ECB9- (L) ECB9-CB (L7) 0A breaker ECB9-6 (L) ECB9-6CB (L9) A breaker ECB9-8 (L0) ECB9-8CB (L) A breaker ECB9-9CB (L) 60A breaker ECB9-.CB (L) () A Breaker and () 0A breaker No. of Stages Input Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Ckt Ckt Single Point Power Source 08.0 0,0 7.6 8 - - - - - - 0 - - - - - - - - - - - - 0.,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.7,0 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0.0,60 7.6 0 - - - - - - 0 - - - - - - - - - - - - 08.8,800 7.6 - - - - - - - - - - - - - - - - - - 0.,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.6,700 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 08.,00 7.6 7 - - - - - - 0 - - - - - - - - - - - - 0.0 7,00 7.6 - - - - - - - - - - - - - - - - - - 0. 8,800 7.6 - - - - - - - - - - - - - - - - - - 0 6.0 0,00 7.6 - - - - - - - - - - - - - - - - - - 08 6.0 0,00 7.6 6 - - - - - - 0 - - - - - - - - - - - - 0 6.7,900 7.6 - - - - - - 60 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - 60 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - 60 - - - - - - - - - - - - 08 6.8,00 7.6 0 - - - - - - 0 - - - - - - - - - - - - 0 7.6,800 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 8. 8,00 7.6 6 - - - - - - 60 - - - - - - - - - - - - 0 9.0 0,700 7.6 6 - - - - - - 60 - - - - - - - - - - - - 08 9.,000 7.6 8 8 - - - 0 0 - - - 66 70 0 0.,800 7.6 - - - - - - 7 80 0. 9,00 7.6 - - - - - - 7 80 0.,600 7.6 - - - - - - 7 80 kw lbs. 0 kw 9 lbs. ECB9-CB (L6) () 0A breaker and () 60A breaker ECB9-0CB (L8) () 0A Breaker and () 60A breaker 08. 8,00 7.6 - - - - - - 77 80 0.6,000 7.6 6 - - - 0 60 - - - 88 90 0. 7,000 7.6 6 - - - 0 60 - - - 88 90 0.0,00 7.6 6 - - - 0 60 - - - 88 90 08.0,00 7.6 0 0 - - - 0 0 - - - 00 0 6.8 7,00 7.6 6 7 - - - 60 60 - - - 0 8. 6,700 7.6 6 7 - - - 60 60 - - - 0 0.0 68,00 7.6 6 7 - - - 60 60 - - - kw 9 lbs. ECB9-CB (L9) () 0A breakers NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. 08 8.8 6,00 7.6 7 8 8 0 0 0 0.0 7,700 7.6 60 0 0 0.0 78,00 7.6 60 0 0 0.0 8,00 7.6 60 0 0 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. CBX7UH / Page 9

ELECTRIC HEAT DATA - CBX7UH-060 THREE PHASE 8 kw lbs. 0 kw 6 lbs. kw lbs. 0 kw 9 lbs. kw 9 lbs. Model Number ECB9-8 (L6) Terminal block ECB9-0 (L6) ECB9-0 (8K7) () 0A Fuses ECB9-CB (L6) 0A breaker ECB9- (8K8) () A Fuses ECB9-0CB (L6) () A breaker ECB9-0 (8K9) () A Fuses 6 ECB9-0 (8K) () A Fuses ECB9-CB (L6) () A breaker ECB9- (8K0) () 0A Fuses 6 ECB9- (8K) () A Fuses No. of Stages Input NOTE - includes the Blower Motor Full Load Amps. Electric heater capacity only - does not include additional blower motor heat capacity. Amps shown are for blower motor only. Blower Motor Full Load Amps Volts kw Btuh Ckt Ckt Ckt Ckt Single Point Power Source 08 6.0 0,00 7.6 0 - - - 0 - - - - - - - - - 0 6.7,900 7.6 - - - - - - - - - - - - 0 7.,00 7.6 - - - - - - - - - - - - 0 8.0 7,00 7.6 - - - - - - - - - - - - 08 7.,600 7.6 6 - - - 0 - - - - - - - - - 0 8. 8,700 7.6 0 - - - 0 - - - - - - - - - 0 9.,00 7.6 0 - - - 0 - - - - - - - - - 0 0.0,00 7.6 0 - - - 0 - - - - - - - - - 0 8. 8,700.0 8 - - - 0 - - - - - - - - - 60 9.,00.0 9 - - - 0 - - - - - - - - - 80 0.0,00.0 0 - - - - - - - - - - - - 08. 8,00 7.6 9 - - - 0 - - - - - - - - - 0.6,000 7.6 - - - 60 - - - - - - - - - 0. 7,000 7.6 - - - 60 - - - - - - - - - 0.0,00 7.6 - - - 60 - - - - - - - - - 0.6,000.0 - - - 0 - - - - - - - - - 60. 7,000.0 6 - - - 0 - - - - - - - - - 80.0,00.0 7 - - - 0 - - - - - - - - - 08.0,00 7.6 6 6 0 0 6 70 0 6.8 7,00 7.6 0 0 0 0 70 70 0 8. 6,700 7.6 0 0 0 0 70 70 0 0.0 68,00 7.6 0 0 0 0 70 70 0 6.8 7,00.0 - - - - - - - - - - - - 60 8. 6,700.0 - - - - - - - - - - - - 80 0.0 68,00.0 - - - 0 - - - - - - - - - 0 6.8 7,00.0 7 - - - 0 - - - - - - - - - 7 8. 6,700.0 8 - - - 0 - - - - - - - - - 600 0.0 68,00.0 9 - - - 0 - - - - - - - - - 08 8.8 6,00 7.6 7 80 0.0 7,700 7.6 7 8 0 0 8 90 0.0 78,00 7.6 7 8 0 0 8 90 0.0 8,00 7.6 7 8 0 0 8 90 0.0 7,700.0 9 - - - 0 - - - - - - - - - 60.0 78,00.0 - - - - - - - - - - - - 80.0 8,00.0 - - - - - - - - - - - - 0.0 7,700.0 - - - - - - - - - - - - 7.0 78,00.0 - - - - - - - - - - - - 600.0 8,00.0 - - - 0 - - - - - - - - - Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. Use wires suitable for at least 67 F. Bold text indicates that the circuit breaker on CB circuit breaker models must be replaced with size noted. See Table on Page 9. HACR type circuit breaker or fuse. 6 Blower motor is rated at 60V. CBX7UH / Page 0

DIMENSIONS - INCHES (MM) UPFLOW POSITION / (9) / (9) -/6 (8) D LINE VOLTAGE INLETS (Top and Left Side) TOP VIEW B SUPPLY AIR OPENING / (9) LOW VOLTAGE INLETS (Top and Right Side) /8 (6) -/8 (9) SUCTION LINE () -/8 (7) LIQUID LINE C -/ (70) DETAIL OF PIPING PLATE -/ () -/8 () -/ (89) CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Upflow and Downflow) AIR FLOW G OPTIONAL ELECTRIC HEAT (Field Installed) BLOWER Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. A PIPING PLATE H SUCTION LINE COIL LIQUID LINE /8 (6) Return Air F FRONT VIEW /8 (6) FILTER ACCESS FILTER () Return Air E SIDE VIEW /8 (6) Model No. A B C D E F G H CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 CBX7UH-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm 0 0 8 08 6 6 in. -/ -/8 9-/ 0 6-/8 -/8 mm 9 0 7 0 08 670 6 in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm 86 0 6 0 8 08 708 778 in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm 88 0 6 0 8 08 708 879 CBX7UH / Page

DIMENSIONS - INCHES (MM) DOWNFLOW POSITION with Optional Downflow Conversion Kit (Required) DETAIL OF PIPING PLATE /8 (6) E /8 (6) F RETURN AIR OPENING /8 (6) -/8 (9) SUCTION LINE () /8 (9) LIQUID LINE -/8 () CONDENSATE DRAINS () (Horizontal) CONDENSATE DRAINS () (Up-Flow and Downflow) () TOP VIEW () -/ () -/ (89) B FILTER ACCESS C FILTER H PIPING PLATE SUCTION LINE COIL LIQUID LINE AIR FLOW G A OPTIONAL ELECTRIC HEAT (Field Installed) LOW VOLTAGE (Right Side) LINE VOLTAGE (Left Side) BLOWER / (9) Supply Air D FRONT VIEW / (9) /8 (6) Supply Air -/6 (8) SIDE VIEW /8 (6) Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. Model No. A B C D E F G H CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 CBX7UH-060 in. 9-/ -/ 0-/8 9-/ 9 0 -/8 -/8 mm 0 0 8 08 6 6 in. -/ -/8 9-/ 0 6-/8 -/8 mm 9 0 7 0 08 670 6 in. 8-/ -/ -/8 9-/ 0 7-7/8 0-/8 mm 86 0 6 0 8 08 708 778 in. 6-/ -/ -/8 9-/ 0 7-7/8 -/8 mm 88 0 6 0 8 08 708 879 CBX7UH / Page

DIMENSIONS - INCHES (MM) DETAIL OF PIPING PLATE RIGHT-HAND AIR DISCHARGE -/8 (7) () LIQUID LINE FILTER SUCTION LINE -/ (6) CONDENSATE DRAINS () (Upflow and Downflow) /8 (6) -/ () -/ (8) -/8 (9) -/8 () CONDENSATE DRAINS () (Horizontal) LIQUID LINE COIL SUCTION LINE H TOP VIEW A BLOWER OPTIONAL ELECTRIC HEAT (Field Installed) G C Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. /8 (6) LINE VOLTAGE INLETS (Top and Right Side) -/6 (8) / (9) / (9) E /8 (6) F RETURN AIR OPENING () PIPING PLATE AIR FLOW B SUPPLY AIR OPENING D /8 (6) END VIEW FILTER ACCESS FRONT VIEW LOW VOLTAGE INLETS (Bottom and Right Side) END VIEW / (9) LEFT-HAND AIR DISCHARGE FILTER DETAIL OF PIPING PLATE C BLOWER COIL -/8 () Note Units are shipped in one piece but may be disassembled into two separate sections for ease of installation. OPTIONAL ELECTRIC HEAT (Field Installed) TOP VIEW SUCTION LINE LIQUID LINE -/8 (9) SUCTION LINE LIQUID LINE () -/8 (7) / (9) / (9) -/6 (8) LOW VOLTAGE INLETS (Top and Left Side) /8 (6) G A H /8 (6) D SUPPLY AIR OPENING B AIR FLOW PIPING PLATE FILTER ACCESS CONDENSATE DRAINS () (Horizontal) () E RETURN AIR OPENING F /8 (6) / (9) END VIEW LINE VOLTAGE INLETS (Bottom and Left Side) FRONT VIEW -/ () -/ (6) -/ (8) /8 (6) END VIEW Model No. CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 A B C D E F G H inch mm inch mm inch mm inch mm inch mm inch mm inch mm inch mm 9-/ -/ 0 0-/8 9-/ 0 9 8 0 08 -/8 6 -/8 6 9 -/ 0 -/8 7 9-/ 0 0 08 6-/8 670 -/8 6 8-/ 86 -/ 0 -/8 6 9-/ 0 8 0 08 7-7/8 708 0-/8 778 CBX7UH-060 6-/ 88 -/ 0 -/8 6 9-/ 0 8 0 08 7-7/8 708 -/8 879 CBX7UH / Page

DIMENSIONS - INCHES (MM) AIR FLOW PIPING PLATE AIR FLOW B B AIR FLOW PIPING PLATE A /8 (6) RIGHT-HAND AIR FLOW B /8 (6) /8 (6) A LEFT-HAND AIR FLOW B AIR FLOW PIPING PLATE A Model No. CBX7UH-08 CBX7UH-0 CBX7UH-00 CBX7UH-06 CBX7UH-0 CBX7UH-08 A B in. mm in. mm 9-/ -/ 0 9 -/ 0 8-/ 86 -/ 0 CBX7UH-060 6-/ 88 -/ 0 PIPING PLATE AIR FLOW A UPFLOW DOWNFLOW /8 (6) SIDE RETURN UNIT STAND (Upflow Only) 6 (06) 6 () -/ (0) ADJUSTABLE 0 (08) to (6) ALL UNITS CBX7UH / Page

DIMENSIONS - INCHES (MM) DOWNFLOW COMBUSTIBLE FLOORING BASE AIR HANDLER DOWNFLOW COMBUSTIBLE FLOORING BASE Catalog No. K -/8 () -/8 () 0 (08) TOP VIEW -/8 (89) / (9) Break off extended width at pre-perforated line to fit specific air handler application. NOTE - Width of base includes an additional in. ( mm) for air handler positioning adjustment. -/8 () SUPPLY AIR OPENING /8 (6) -/ () Opening SIDE VIEW (76) A B C D No modification required. Model No. 08, 0 00, 06 0, 08, 060 in. mm in. mm in. mm A -/8 7 - - - - - - - - - - - - B - - - - - - -/8 6 - - - - - - C - - - - - - - - - - - - 6-/8 676 CBX7UH / Page

REVISIONS Sections Electric Heat Data Description of Change New catalog numbers for electric heat models. Removed EvenHeater electric heat models. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800--LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 0 Lennox Industries, Inc.