WARNING Risk of property damage, injury, or death.

Similar documents
21", 33", 45", & 61" Installation & Operation Manual

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

UV-AIRE AIR PURIFYING SYSTEM

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

HARDWARE KIT INSTALLATION GLOVES

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Installation Instructions

PHOTO-CATALYTIC AIR PURIFIER SYSTEMS

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

FOODSAFE IL INSTALLATION MANUAL

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

MINISTICK TM UV Germicidal Ultraviolet Light

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

UV-AIRE AIR PURIFYING SYSTEM

INSTALLATION INSTRUCTIONS TRAILER HITCH MAIN HARNESS KIT

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Portable Sanitizing Wand. Model: VH03. The CleanWave Portable Sanitizing Wand kills up to 99.9% of germs and odorcausing. surfaces.

COLD WEATHER START KIT Platinum Mini Split

FOG LAMPS INSTALL KIT

INSTALLATION INSTRUCTIONS

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

TOYOTA RAV4/HV INTERIOR LIGHT KIT Preparation

T A A 120 S 4 D - 1 M

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

SCION xb SIRIUS SATELLITE RADIO TUNER Preparation

Model AERO-24. Model ADHO24-4. Model AD24-2

Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

Mania EF1 user manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Platinum Split 8000 & Platinum Split 8000 Fully Ducted COLD WEATHER START KIT Installation Manual

LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

TOYOTA YARIS HATCHBACK INTERIOR LIGHT UPGRADE Preparation

Toyota Prius Interior Light Upgrade

TOYOTA im INTERIOR LIGHT KIT Preparation

LUNA Air for life. Featuring: NASA Developed Technology. Owner s Manual. Photocatalytic Oxidation Induct Air Purification System.

SCION xd INTERIOR LIGHTING UPGRADE Preparation

Section II - Installation Procedures Part Number : Accessory Code IL1 Kit Contents. Color Applicability/Trim Level. Hardware Bag Contents

OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER

TOYOTA AVALON INTERIOR LIGHT UPGRADE Section TOYOTA II - Installation AVALON Procedures

INSTALLATION INSTRUCTIONS

VH03 SAVE THESE INSTRUCTIONS

ELITE Series R-410A - Upflow / Horizontal

TOYOTA TUNDRA TVIP V4 REMOTE ENGINE STARTER (RES)

Air flow GUV-161. Box size is 8.25 high x 4.25 wide For service please call Germicidal UV-C Lamp. Furnace. 2.

TOYOTA TUNDRA TVIP V4 Preparation

Altman Stage Lighting Safety Instructions & Warnings UV-250 Blacklight Floodflight

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

Installation Instructions BLTR and 2BLTR Relight Assembly

GENUINE PARTS INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Owner s Manual. Installation, Operation & Maintenance. Read and Follow All Safety Instructions. Save These Instructions. Model TM36-2.

INSTALLATION INSTRUCTIONS INFINITI CELLPORT UNIVERSAL HANDS FREE SYSTEM

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Preparation Part Number: PT Kit Contents Item # Quantity Reqd. Description 1 1 Rear Spoiler 2 1 Hardware Kit. Hardware Bag Contents

WARNING. Important Notice

General Applicability Note: Recommended Tools. Personal & Vehicle Protection Safety Goggles Seat Covers Floor Covers Special Tools. Installation Tools

INSTALLATION INSTRUCTIONS

TOYOTA CAMRY HANDS FREE BLU LOGIC Preparation

INSTALLATION AND USER INSTRUCTIONS

Scion xb Interior Light Upgrade Part Number: Accessory Code: YI1

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Air for life Featuring: NASA Developed Technology

Air Knight REME by RGF

Conflicts. Toyota Avalon Interior Light Upgrade. Part Number Accesory Code: IL2. Color Applicability/Trim Level.

Installation Instructions Part Number

SCION tc ILLUMINATED DOOR SILLS Preparation

Toyota Venza Interior Light Upgrade

COLD WEATHER START KIT Ceiling Mount 8000

Inazuma Installation and Operating Instructions INAZUMA HD PRO UV-C. High-Performence Duo UVC Lamp

TOYOTA VENZA HANDS FREE BLU LOGIC Preparation

BL7000 SYSTEM OPERATING MANUAL

PART NUMBER: H630SSJ000. Kit Contents: A. Amplifier with Bracket (1) D. Badge (2) with push nuts (4)

Corded and Cordless LED Worklight

UNPACKING THE UNIT. Alcohol cleaning pad

TOYOTA RAV INTERFACE KIT FOR IPOD Preparation Part Number: PT

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

4000 SYSTEM OPERATING MANUAL

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TOYOTA SEQUOIA TVIP V4 REMOTE ENGINE STARTER (RES)

ROOM AIR SANITIZER GERMICIDAL ULTRAVIOLET ADVANTAGES OF THE SANITAIRE SYSTEM

Conflicts: JBL Audio, Factory Navigation, Accessory XM Satellite Radio, and Accessory Sirius Satellite Radio

TOYOTA CAMRY LE / SE / XLE DUAL SEAT HEATER KIT Section I Pre-Installation Check

Transcription:

INDOOR AIR QUALITY PRODUCTS KITS AND ACCESSORIES 506412 01 10/09 Litho U.S.A. HEALTHY CLIMATE GERMICIDAL LIGHT KIT INSTALLATION & USER INSTRUCTIONS FOR HEALTHY CLIMATE GERMICIDAL LIGHT MODELS C1UVCL10B 1 (54W62) WARNING Risk of property damage, injury, or death. Installation, adjustments, alterations, service and maintenance must be performed by a licensed professional service technician (or equivalent). General The Healthy Climate germicidal light emits ultraviolet (UVC) energy that has been proven effective in reducing microbial life forms (viruses, bacteria, yeasts, and molds) in the air. UVC germicidal lamps greatly reduce the growth and proliferation of mold and other bio aerosols (bacteria and viruses) on illuminated surfaces. Germicidal lamps are NOT intended to be used for removal of active mold growth. Existing mold growth must be appropriately removed PRIOR to installation of the germicidal lamp. Model C1UVCL10B 1 is covered by this document. DANGER Ultraviolet (UVC) Radiation Hazard. Any exposure will cause significant eye damage and may cause skin damage. DO NOT look into UVC light source. Access panels must be in place during appliance operation. Disconnect power to UVC appliance before general servicing air handler. Application The Healthy Climate UVC light kit is specifically designed for the Lennox rooftop models: LCH092 150, LGH092 150, KCA092 150, KGA092 150, KHA092 150. In addition, the light is equipped with shields to focus the UVC light on the coil surface where it is needed and reduce the exposure of light on other components and access panels for improved safety and overall effectiveness. Enhanced rapid start ballast provides UVC lamp operation at a full range of operating conditions. Lamps operate on 110 230V single-phase power supply. Step-down transformer may be ordered separately for 460V and 575V rooftop units. Alternately, 110V power supply may be used to directly power the UVC ballast(s). Shipping & Packing List Contents 1 Healthy Climate germicidal light consisting of: 1 UVC light assembly 1 UVC lamp 2 36" long, 1" diameter convoluted tubing 2 9" long, 1" diameter convoluted tubing 1 24" long, 1" diameter convoluted tubing 1 Bag assembly, includes: 1 Installation instructions 1 Warranty sheet 1 UVC Danger label 16 Wire ties 7 #10 16 x 5/8" screws 2 dual quick connect adapters 1 wire harness NOTE Not all components provided in kit are used in each application. Check parts for shipping damage. Receiving party should contact last carrier immediately if shipping damage is found. 10/09 506412 01 Page 1

WARNING Potential Mold Spore Release. Application of UVC lamps to existing mold growth can cause respiratory irritation and allergic symptoms. Do not use UVC lamps where active mold growth exists. Remove active mold growth from surfaces prior to operation of UVC lamps. NOTICE Potential odor emissions. Odors may be present when some materials are exposed to UV light. These materials may include Technicoated or E Coated Coils. Other materials may include chemicals, solvents, polymers and organic materials. Some occupants may notice irritation or discomfort. If odors are present, the UV Lights should be turned off and fresh air should be introduced into the occupied space immediately. Contact your Independent Lennox Dealer. CAUTION Potential Risk of Degradation of Materials. Potential of degraded wire insulation may cause human injury through electrical shock. UVC light may damage plastics and rubber materials. May cause fabric discoloration. Avoid UVC light exposure to plastic drain pans, wire insulation, flex duct or other plastic/rubber components. Before installation, confirm that any corrosion-resistant coating (if applied to the coil) will not be negatively impacted by the UVC light exposure. Required Tools and Unique Supplies Drill Phillips screw bit or screwdriver Cotton cloth and gloves Part No. X7623 X7625 Replacement Part Description UVC lamp Enhanced ballast 506412 01 10/09 Page 2

Dimensions/Specifications Dimensions (All models) Lamp Assembly Triangular sheet metal panel Electrical Power Supply C1UVCL10B 1 110/230V, 50/60Hz, 0.5A NOTE For 460V & 575V rooftop units, order separate step-down transformers. Power Consumption C1UVCL10B 1 Lamp/Ballast Operating Environment (All models) Temperature (outside of duct): Relative humidity Specifications subject to change without notice. Unpacking List SHIPPING CARTON CARTON DIVIDER SUB ASSEMBLY UVC 37" L x 4.5" W x 4.5" H (940mm x 114mm x 114mm) 28" L x 12" W x 0.5" H (711mm x 305mm x 13mm) 55 Watts 5 F to 140 F ( 15 C to 60 C) <95%. LAMP SHIELD PANEL SIGHT GLASS BAG ASSEMBLY DANGER LABEL LAMP SLEEVE Page 3 HEALTHY CLIMATE GERMICIDAL LIGHT KIT

Parts Arrangement UV LIGHT CABLE UV LIGHT ASSEMBLY CONTROL PANEL TRIANGULAR SHEET METAL PANEL Figure 1. Parts arrangement with wire routing (Typical) 506412 01 10/09 Page 4

Installation Preparing for installation Before installing the UVC devices: Turn off power to the rooftop unit. Open access to the control box, blower compartment and the filter section. Review unpacking list and parts arrangement and wire routing as shown in figure 1. WARNING Electric shock hazard. Can cause injury or death. Disconnect all remote power supplies before opening any unit access panels. Unit may have multiple power supplies. Do not operate without access panels in place. UVC exposure protection The UVC light is equipped with a unique directional shield to focus the UVC light on the coil surface and drain pan where it is needed and reduce the exposure of light on other components such as wiring, plastic parts etc. For shielding of electrical wiring in the rooftop unit, black convoluted tubing is included with the kit. However, if there is any concern, aluminum foil tape can also be used to cover up any exposed component. WARNING Potential Risk of Fire. Dust, lint and other debris may cause fire if allowed to come in contact with illuminated UVC lamp. Remove any dust, lint or other debris from lamps and surrounding duct system. CAUTION Sharp Edges Hazard. Equipment sharp edges can cause injury. Use protective gloves when grasping equipment edges. Installation of UVC light assembly The lamp for the UVC light assembly comes separately packaged in a foam sleeve. Install the lamp to the UVC assemlbly prior to installing it in the rooftop unit. 1. Wear cotton gloves or use a cotton cloth when handling the new lamp. To install the lamp, remove black plastic splash guards from the (2) lamp holders of the UVC assembly. Gently but firmly push in the splash guards on each end of the lamp (see figure 2). Align and insert the lamp with splash guard into the lamp holders of the UVC assembly until each end clicks into place (see figure 2). Install plastic splash guards and snap each end of the lamp into place. Figure 2. Installing Lamp in Holder Clips 2. Carefully place the UVC assembly on the blower deck. Line up the mounting holes on the UVC assembly with the mounting holes on the blower deck (see figure 3). Use the #10 screws provided to attach the UVC assembly in place. UVCLIGHT ASSEMBLY #10 SCREWS Figure 3. Attaching UVC Light Assembly Page 5 HEALTHY CLIMATE GERMICIDAL LIGHT KIT

Installation of Lamp Cable UVC LIGHT ASSEMBLY UVC LIGHT CABLE Figure 4. Installing Lamp Cable 1. Run the UVC cable along the limit switch wire harness (see figure 4). 2. Route the UVC cable through the coil bracket and divider panel (see figure 5) into the controls section. Wire tie the cable at multiple locations along the existing wire harness. 3. Connect the UVC cable to the control panel based on the applicable section described below in sections A through C. A For all 230V rooftop models, connect the black and white conductors of the UVC cable to transformer T1 using (2) quick connect adapters included in the kit (see figure 6). B C For 460V or 575V rooftop models without T3 transformer, install new step down transformer T49 (ordered separately: 460/230,75VA minimum or 575/230, 75VA minimum). Connect the black conductor of the ballast power cable to the black conductor of the T49 transformer (see figure 7). Connect the white conductor of the ballast power cord to the L2 terminal of the K1 contactor using the adapter provided in the kit. For 575V rooftop models with T3 transformer (for gas heat), connect the black conductor of the ballast power cable to the black conductor of the T3 transformer using the wire harness provided in the kit (see figure 8). Connect the white conductor of the ballast power cord to the L2 terminal of the K1 contactor using the adapter provided in the kit. UVC SUB ASSEMBLY COIL BRACKET UVC CABLE DIVIDER PANEL Figure 5. UVC Wire Routing 506412 01 10/09 Page 6

PRE EXISTING WIRING UVC CABLE ADAPTER LOCATION DETAIL A SEE DETAIL A Figure 6. Connect cable to transformer T1 (230 Volt units) UVC CABLE ADAPTER Figure 7. Connect cable to Step down Transformer T49 (460/575 Volt units) PRE EXISTING GAS HARNESS UVC CABLE WIRE HARNESS (IN- CLUDED IN UVC KIT) ADAPTER Figure 8. Connect cable to transformer T3 (575 Volt units) Page 7 HEALTHY CLIMATE GERMICIDAL LIGHT KIT

Installation of Convoluted Tubing for Shielding Electrical Wiring 1. Install (2) 36" long, 1" diameter convoluted tubing (included in the kit) to shield electrical wiring running along the coil bracket (see figure 9). The tubing is split type making it easy to slip on the wiring. Black wire ties are provided to tie the tubing in place. 2. Install (2) 9" long, 1" diameter convoluted tubing (included in the kit) to shield freeze stat wiring (if applicable) and tied using black wire ties (see figure 9). 3. Install (1) 24" long, 1" diameter convoluted tubing (included in the kit) to shield electrical wiring along the top of the rooftop unit between blower deck and control panel (see figure 9). Black wire ties are provided to tie the tubing in place. 4. In addition, aluminum tape (not provided) can be used if needed to further shield any other surface of concern. NOTE: The cable should not extend past the UVC assembly to be in direct line of sight of UVC lamp. Wrap wires with 24" convoluted tubing. Use wire ties to secure (3 Places) Wire Tie UVC Cable (2 Places) Wrap freezestat wires with 9" convoluted tubing. Use wire ties to secure (4 Places) Wrap wires with 36" convoluted tubing. Use wire ties to secure (4 Places) NOTE: Install Convoluted Tubing after completing wiring of UVC Kit. Installation of sheet metal shield panel To block the UVC light from reaching the filter access door, install the sheet metal panel (see figure 10). Figure 9. Installing Convuluted Tubing With the left flange of the triangular sheet metal panel facing out, insert and lower the bottom of the panel through the opening in the filter access door, to the right of the coil and ahead of the refrigerant lines. Slide the panel against the coil bracket and align the holes of the panel with the pre punched holes on the coil bracket. Use #10 screws (included) to attach the panel to the coil bracket. NOTE The view port in the triangular panel provides a visual verification when the UVC lamp is turned on. Do not remove the view port as it shields UVC light and protects eyes from UVC exposure. TRIANGULAR UV SHIELD Figure 10. Installing Triangular Panel 506412 01 10/09 Page 8

Finish Installation Close all access doors before powering UVC lamp. Apply UVC Danger label to blower access door so that it is clearly visible (see figure 11). The lamp should be replaced every 12 months, as UVC energy production diminishes over time. 1. Obtain the correct replacement lamp for your Healthy Climate germicidal light model. 2. Disconnect power to the rooftop unit before servicing the UVC kit. 3. Open the blower access door. 4. Disconnect the UVC cable quick connects (black/ white). UVC DANGER LABEL Figure 11. Adding UVC DANGER labels Operation For optimal performance, continuous operation of the UVC germicidal lamp is recommended. Maintenance For all maintenance, contact a qualified HVAC technician. If UVC lamp does not come on: 1. Check Power Wiring: Disconnect 1/4" QC (quick connects) of the UVC cable near the UVC assembly. With Power ON, use multimeter to test 110 230V at the 1/4"QC quick connects from the control panel. 2. Check Lamp: Carefully remove the UVC assembly out of the rooftop unit. Use multimeter to test for continuity across each pair of pins at each end of the lamp. 3. Check Lamp Installation: Make sure that lamp s pins snap properly into the lamp holder. Annual Lamp Replacement WARNING Personal Burn Hazard. Personal injury may result from hot lamps. During replacement, allow lamp to cool for 10 minutes before removing lamp from fixture. 5. Remove the (3) mounting screws of the UVC assembly. Carefully remove the complete UVC assembly out through the blower access door. 6. Allow 10 minutes before touching the lamps. Then, carefully remove the lamp splash guards and lamp from each of the lamp holders. 7. Wear cotton gloves or use a cotton cloth when handling the new lamp. Gently but firmly push in the splash guards on each end of the lamp. Align and insert the lamp with splash guard into the lamp holders of the UVC assembly until each end clicks into place (see figure 2 on Page 5). 8. Carefully place the UVC assembly on the blower deck. Line up the mounting holes on the UVC assembly with the mounting holes on the blower deck (see figure 3 on Page 5). Use the #10 screws provided to attach the UVC assembly in place. 9. Close the blower access door. 10. Reconnect power to the rooftop unit. 11. Open the filter access door and look through the view port in the triangular sheet metal panel to verify that the UVC light is on. Lamp Disposal Hg Lamp Contains Mercury Manage in accordance with local, state and federal disposal laws. Refer to www.lamprecycle.org or call 1 800 9 LENNOX. Proper Clean up Technique in Case of Lamp Breakage Wear protective gloves, eye wear and mask. Sweep the broken glass and debris into a plastic bag, seal the bag, and dispose of properly. Contact your local waste management office for proper disposal. Do not use a vacuum cleaner. Do not incinerate. Page 9 HEALTHY CLIMATE GERMICIDAL LIGHT KIT