Tubes OTR Testing Report

Similar documents
INTERNATIONAL PERMEATION MEASUREMENT STANDARDS

DTC P1223, P1226, P1229, P1232, P1235, P1238, P1241, or P1244

DTC P1415 Secondary Air Injection (AIR) System Bank 1

DTC P0201, P0202, P0203, P0204, P0205, P0206, P0207, or P0208

impulse Single-Use Mixers

VIVA IML TUBES. In Mold Labeled Tubes - Cutting Edge Innovation for Top Tier Brands VIVA IML TUBES

PRINETO Price List Prineto

Economic Benefits of Utilizing MDO Films in Flexible Packaging

Percent Change in Seal Strength Relative to the Control for Maximum Load ASTM F88

We create chemistry that makes compost love plastic. Thomas Pitzi Sales Manager North America BASF Biopolymers June 23, 2016

Motorcycle Catalyst Presentation: Meeting the Euro-3 Challenge for 4-Stroke Motorcycles

FILTERS DOUBLE LENGTH, DUPLEX DOUBLE LENGTH, SIMPLEX SINGLE LENGTH, SIMPLEX SINGLE LENGTH, DUPLEX

SECTION U -- STANDBY ENGINE/ALTERNATOR SETS

Beauty.

K-Resin SB Copolymer/Crystal Polystyrene Sheet Property Modification with High Impact Polystyrene

hotrod Cartridge Heaters Application Fields

DTC P0216 Injection Timing Control Circuit

Technical Offer. Antek Model 6200 Analyzer Determine Total Sulfur and Total Nitrogen in a single analyzer

Economic Benefits of Utilizing MDO Films in Flexible Packaging

Drip In PC Pressure Compensating Dripline

Vaporproof Strip - 4 Foot 1-3 Lamps

Cartridge Heaters. Application Field. Application examples

VSL4 Series. Description. Specifications. 2.13in. 2.03in. 3.50in

DTC P1336 Crankshaft Position (CKP) System Variation Not Learned

impulse Single-Use Mixers

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

Compostable Solutions for Packaging. FlexPackCon 2016 Randy Jester

Test Report. for. Chilicon Power 1563 Calle Patricia Pacific Palisades, CA USA. Project Number: G Prepared By:

Tex-614-J, Testing Epoxy Materials

0.3 mm Pitch, 1.0 mm Height FPC Connector

F. VAV hoods shall have a restricted bypass plate.


TKD SERIES 3-WAY BALL VALVES - TRUE UNION

CHECK AND CALIBRATION PROCEDURES FOR FATIGUE TEST BENCHES OF WHEEL

9. Subaru Select Monitor

2000 BUICK LESABRE A 3.8 V6 (K) GAS Excellent

Comparison of Styropor and Neopor Expanded Polystyrene Foam Insulations HAI Project No. 1JJB

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

BROAD SAMPLING TPO TEST PROGRAM

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

Not to be distributed outside of FM Approvals and its affiliates except by Customer


REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

TKD SERIES 3-WAY BALL VALVES - TRUE UNION

MG7000 Operating Instructions & Parts Manual

Tex-614-J, Testing Epoxy Materials

Document Number: AUP003 Revision:00 Page 1 of 5. This specification is applicable to GP Ultra Plus Alkaline Cell, GP15AUP(No mercury added).

Standard G50 90 degree Table with cable to upper machine crosshead and G227 upper grips. G Width 130 mm (5.1 )

FEATURES PORT ARRANGEMENTS

THE AMAZING INTRODUCING FUEL RESERVOIR SYSTEM. Race Proven in ARCA Racing Series!

QualityWatch. Report Number 1 CAPA. November A Periodic Report on Non CAPA Certified Aftermarket Replacement Parts

Type Electrically Actuated Ball Valve

PROVEX Installation Guide. Version 1.0

Engine Control (1MZ-FE)

STRYKER VEHICLE ADVANCED PROPULSION WITH ONBOARD POWER

Type Electrically Actuated Ball Valve

Highly Engineered Tooth and Pawl Design for Maximum Engagement MINIATURE (PAGE J37) INTERMEDIATE (PAGE J37)

Thermocouples W A T L O W

Reliability Report Reliability Data for IX9908

Type 375. True Union Ball Valve

Dependence of particle size distribution on injection pressure

General Description and Quick Selection Guide...E2. Series SAS Panel Mount Hockey Puck Relays...E4. Series SAR DIN-Rail Mount Relays...

LOADHOG BATTERY CHARGER

Chapter 20 OBD-II Diesel Monitors

Electrical Characteristics of MAX220/222/232A/242/ Rev. G /883B for /883B and SMD page 1 of 5

R. Lang Company SLIDING PATIO DOORS SECTION D. Page 27. Tel: Fax: SECTION C SECTION D

Quick Splice II. 35 kv Molded Rubber Inline Splicing Kit Data Sheet. 2. Applications. 1. Product Description


Integrated Vector-Type Pump Drive Product Group D and W

DTC P1515 Control Module Throttle Actuator Position Performance

CABLED TWISTED PAIRS CONDUCTORS

Jogging and Plugging of AC and DC Motors. Prepared by Engr. John Paul Timola, LPT

Fast, Effective Blowout Protection

Standard G50 90 degree Table with cable to upper machine crosshead and G227 upper grips

Physical Properties. Temperature Limits. Durometer 60 +/-5. Average Elongation 350% Specific Gravity 1.50 Polymer Content 20% -20 o F to +212 o F

Reliability Report Reliability Data for CPC5001G

this, they are not used as in installation tool. Residential projects do not require a layout to be generated.

Installation and Operation Manual PN Eff

CCS Zone/Bypass Damper Assembly

Document ID: General Motors Corporation. All rights reserved.

TECHLINE 16 SELF- CLEANING, PRESSURE-COMPENSATING TUBING

ASTM Consensus Standards The Latest in Packaging Testing. Presented by: Dhuanne Dodrill President Rollprint Packaging Products, Inc.

DL 38 DOOR LOCK WIRELESS DOOR LOCK CONTROL SYSTEM REGISTRATION

C2, C3, C4 Monomer Analysis

Report On Sequence IIIG Evaluation. Version. Conducted For. NR = Non-Reference Oil Test RO = Reference Oil Test

EnVibe, Inc. Houston, Texas. Carbon Seal Rub on a Steam Turbine

DTC P0420. Circuit Description. Conditions for Running the DTC.

DTC P0743 sets when the TCM detects an open circuit, a short to power, or a short to ground in the TCC PWM solenoid circuit for 1.5 seconds.

PVC SCHEDULE 40 FITTINGS

Tender No. : Ref. No. : LSGS-13-CX User / Customer : Page No. : 1 of 9. Specification. For

DTC P1518 Throttle Actuator Control (TAC) Module Serial Data Circuit

Injection Moulding Kit - Section: Situation / Brief

Model Year: 2008 Model: ES350 Doc ID: RM000000PFA04GX

Sportsman SXS Technical Specifications

Quick Splice II 5451R. 25/28 kv Molded Rubber Cable Repair Splicing Kit Data Sheet. 1. Product Description. 2. Applications

SEMCO CONSUMABLES. Packaging & Application Systems TO ORDER, PLEASE CALL

MICROPOROUS POLYMERIC LUBRICANTS

THERMOELECTRIC SAMPLE CONDITIONER SYSTEM (TESC)

Breast module: all stages

Gasoline Specifications

Transcription:

Tubes OTR Testing Report We have approached Mocon, a specialized Oxygen Transmission Rate (OTR) testing equipment manufacturer to run a series of OTR tests on both Viva injection-molded tubes and extruded tubes commonly available in the market. We ran the OTR tests using method of ASTM D3985, ASTM F1927, ASTM F1307. Test reports have been enclosed at the end of this report. We did different tests with different samples with control tests and samples to assure test results are accurate and consistent. Below are the 5 key findings summarized from all different tests and samples: ITEM OTR Test Results ( cc/pkg/day ) OTR Test Results ( cc/m²/day ) 1. Extruded tube with EVOH barrier 0.270730 10.6 2. Viva injection-molded tube with Foil barrier 0.255750 9.2 3. Viva injection-molded tube with Foil barrier including shoulder area 0.091569 4.6 4. Viva injection-molded tube with EVOH barrier 0.216101 9.9 5. Viva injection-molded tube with EVOH barrier including shoulder area 0.091976 4.2 Remarks: The OTR test result (cc/pkg/day) needs to be converted to (cc/m²/day) in order to be compared. Calculation method as follows: Total packaging surface area = tube body area + shoulder area = A m² OTR (transmission rate @ 100%) from test report = Z cc/pkg/day OTR (cc/m²/day) = (Z/A) cc/m²/day Summary: Viva injection-molded tube with foil/evoh barrier can achieve better OTR than extruded tube with EVOH barrier. This will cover most applications in the current market which require barrier properties e.g. sunscreen, hair care, skin care, personal care and food etc. For applications which require higher level of barrier properties, e.g. toothpaste, we can offer tube with foil/evoh barrier including shoulder area. However, some products may cause the tubes to fail and so testing of tubes with the intended products are still required.

Material Id: C3 Test Number: <D50 Extruded Tube with EVOH Barrier> Using Method: ASTMD3985, ASTMF1927,ASTMF1307 Auto: 23.0 / 23.0 C. Manual: 760.00 mmhg Permeant - Auto: 65.0%, Carrier - Auto: 0.8% 0.056853 cc / [ pkg - day ] 0.270730 cc / [ pkg - day ] 0.270730 cc - mil / [ pkg - day ] ExamMinutes: 30 Conditioning: 5 Hours Cycles Complete: 6 1/22/2011 8:38:04 AM Elapsed Time: 12:31 0:00 Condition 5:00 Test 6:15 0.381410 7:15 0.331250 9:00 0.278504 10:00 0.272031 11:45 0.271307 12:31 0.270730 12:39 Complete 0.400 0.350 0.300 0.250 0.200 0.150 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Printed on 1/22/2011 at 9:18:10 PM Page 1 of 1

Material Id: <v16a> Test Number: <D50 Injection-molded Tube with Foil Barrier> Using Method: ASTMD3985, ASTMF1927,ASTMF1307 Auto: 23.0 / 23.1 C. Auto: 737.37 mmhg Permeant - Auto: 63.4%, Carrier - Auto: 0.0% 0.053707 cc / [ pkg - day ] 0.255750 cc / [ pkg - day ] 0.102300 cc - mm/ [ pkg - day ] ExamMinutes: 45 Conditioning: 5 Hours 9/21/2011 5:18:57 PM Elapsed Time: 20:00 0:00 Condition 5:00 Test 6:30 0.268904 8:45 0.253837 11:00 0.254084 13:15 0.255499 15:30 0.257819 17:45 0.255686 20:00 0.255750 21:16 Complete 0.400 0.350 0.300 0.250 0.200 0.150 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Printed on 9/22/2011 at 2:35:42 PM Page 1 of 1

Material Id: <V21a> Test Number: <D40 Injection-molded Tube with Foil Barrier & Shoulder> Using Method: ASTM D3985, ASTMF1927, ASTM F1307 Auto: 23.0 / 23.0 C. Auto: 756.15 mmhg Permeant - Auto: 61.4%, Carrier - Auto: 0.0% 20.9 % Transmission at 20.9% 0.019138 cc / [ pkg - day ] Transmission at 100% 0.091569 cc / [ pkg - day ] 0.036628 cc - mm / [ pkg - day ] ExamMinutes: 45 Conditioning: 5 Hours 11/29/2011 4:50:36 PM Elapsed Time: 17:45 0:00 Condition 5:00 Test 6:30 0.098507 8:00 0.094598 10:15 0.092000 11:45 0.091675 14:00 0.091297 15:30 0.091541 17:45 0.091569 18:48 Complete 0.090 0.080 0.070 0.060 0.040 0.030 0.020 0.010 0.00 2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 Printed on 11/30/2011 at 11:40:53 AM Page 1 of 1

Material Id: <23b> Test Number: <D40 Injection-molded Tube with EVOH Barrier> Using Method: ASTM D 3985, ASTM F 1927, ASTM F 1307 Auto: 23.0 / 23.1 C. Manual: 760.00 mmhg Permeant - Auto: 28.9%, Carrier - Auto: 0.7% 0.045381 cc / [ pkg - day ] 0.216101 cc / [ pkg - day ] 3.403171 cc - mil / [ pkg - day ] CELL B INFORMATION: ExamMinutes: 30 Conditioning: Disabled 12/27/2011 8:09:01 AM Elapsed Time: 8:00 0:00 Test 1:30 0.191019 2:30 0.200941 3:30 0.214988 4:30 0.217060 6:00 0.216762 7:00 0.216172 8:00 0.216101 8:00 Complete 0.300 0.250 0.200 0.150 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 Printed on 12/27/2011 at 4:09:45 PM Page 1 of 1

Material Id: <24a> MOCON OX-TRAN 2/21 - Single Test Report Test Number: <D40 Injection-molded Tube with EVOH Barrier & Shoulder> Using Method: ASTM D 3985, ASTM F 1927, ASTM F 1307 Auto: 23.0 / 23.0 C. Manual: 760.00 mmhg Permeant - Auto: 26.0%, Carrier - Auto: 0.1% 0.019315 cc / [ pkg - day ] 0.091976 cc / [ pkg - day ] 1.448461 cc - mil / [ pkg - day ] ExamMinutes: 30 Conditioning: Disabled 12/30/2011 8:01:36 AM Elapsed Time: 7:30 0:00 Test 1:00 0.081440 2:00 0.092307 3:00 0.093571 4:00 0.092998 5:30 0.092020 6:30 0.091160 7:30 0.091976 8:11 Complete 0.090 0.080 0.070 0.060 0.040 0.030 0.020 0.010 0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 Printed on 12/30/2011 at 4:12:58 PM Page 1 of 1