Pamphlet M0000. Three-in-One Pressure Regulator, Separator, and Steam Trap COSPECTR PRESSURE REDUCING VALVES

Similar documents
Surplussing Valve SP-COSR-16

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Float Dynamic Steam Trap J10

Manufacturer Kakogawa, Japan DC5S

IBV Series C-LF2 Carbon Steel Inverted Bucket Vertical Steam Trap

Pneumatic Control Valve for Steam PN-COSR-16

MFP14, MFP14S and MFP14SS Automatic Pumps

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference. PRESSURE REDUCING VALVES FOR STEAM COS/COSR Series.

FLOW TEK VALVES & CONTROL S INC

S and SF Series Cast Iron Inverted Bucket Steam Traps

Primary Pressure Regulating Valve Pressure Sustaining Valve Differential Pressure Regulating Valve

FT47 SG Iron Ball Float Steam Traps (DN15 to DN50)

HYDRAULIC CONTROL VALVES

High-precision Multi-control Valve for Steam COSPECT MC-COS-3/MC-COS-16

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference BALANCED PRESSURE THERMOSTATIC STEAM TRAPS LV SERIES

Bypass Blowdown Steam Trap BT3N / MBT3N / PBT3N

Free Float Air Trap G8

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

CV-COSR. Pneumatic Control Valve. Copyright 2013 by TLV CO., LTD. All rights reserved

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

M21Hi ISO Reduced Bore Ball Valve DN15 to DN150 Flanged PN40

SCA Series Steel Inverted Bucket Steam Traps

SECTION Pressure & Temperature Control

YARWAY FLOAT TRAPS SERIES 23000, 26000, 33000

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference THERMODYNAMIC STEAM TRAPS HR-A SERIES HR150A.

AN ISO 9001:2008 CERTIFIED COMPANY. Safety Valve

UNA 13 UNA 15 UNA 15 Stainless Steel Design. Installation Instructions Steam Traps UNA 13, UNA 15

Motorized Pressure Reducing Valve for Steam COSPECT M-COS-3 / M-COS-16 / M-COS-21

Gauges, Sight Glasses and Vacuum Breakers

M21Fi ISO Ball Valve DN15 to DN150

KLINGER BALLOSTAR KHE

DOROT CONTROL VALVES CATALOGUE

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Direct Contact Desuperheaters

Bypass Blowdown Steam Trap (Free Float Steam Trap with X-element) J3S-X-BV / J3S-X-PB / J3S-X-MB

VAD Variable Area Desuperheaters

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

Air Operated Valve Control Valve

M10Si ISO Ball Valve DN¼" to DN2½"

M21Fi ISO Reduced Bore Firesafe API607 Ball Valve DN15 to DN150 Flanged PN40

HD Series. Pilot-Operated Regulating Valves. HD Series features & benefits

Spiratec ST14, ST16 and ST17 Sensor Chambers and Sensors

Fisher CAV4 Control Valve

Direct Contact Desuperheaters

PV4 and PV6 Piston Valves

The Ultimate Solution in Flow Control. Manufactured By:

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

Fig B34 Carbon Steel 'T' Type or Basket Type Strainers

STEEMCO Flowmeter for Steam

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 APRIL 2004

627 Series Pressure Reducing Regulators

Control Valves & Regulators

T he -A900 series of automatic control

Yarway Hy-Drop Throttling valve

Electric Flanged PN16 Cast Iron Ball Valve

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

M-COSR-3 / M-COSR-16 / M-COSR-21

Butterfly Valves CONCENTRIC BUTTERFLY VALVES 3-OFF SET TYPE BUTTERFLY VALVES AGECT-BFV

Python Series Control Valves

M10F Ball Valve DN¼" to DN2½"

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

AUTOMATIC CONTROL VALVES BY RAPHAEL

MNSD-V MULTIPLE NOZZLE SPRAY DESUPERHEATER BULLETIN 1144 SEPTEMBER 2001

Pilot Operated Pressure Surplussing Valve with Cast Steel Body

PF6 Stainless Steel Piston Actuated On/Off Valves

[DRAFT VERSION] For use for company in Europe who will place the product on the market. Please amend which necessary. Document No:

Fisher CAV4 Control Valve

CASH VALVE B SERIES PRESSURE REGULATORS

Phone (toll-free): (888) Phone (local): (973) Fax: (973) Web:

26 Series Stainless Steel 2-way Ball Valves

DP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

Pressure operated water valve Type WVFX and WVS

PRESSURE REGULATORS PRESSURE REDUCING. APPLICATION: Regulation of inlet pressure to gas compressors. Control of supply or distribution system pressure

627 Series Pressure Reducing Regulators

Piston Actuated Valve Type G

HIGH TEMPERATURE HIGH PRESSURE CONTROL VALVES SERIES

Pressure reducing valves

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

Temperature: TYPE A (1" 3") TYPE B (1/2" TYPE C (1/2" 4") TYPE D (3"

WARCO CHEMAG SERIES GH FILTERS

Iron Horse ED Series Pressure Regulator

M21Ti ISO Reduced Bore Ball Valve for the Tobacco Industry DN15 to DN150 Flanged PN40

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

627 Series Pressure Reducing Regulators

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

DP143, DP143G and DP143H. Pilot Operated Pressure Reducing Valves with Cast Steel Bodies

SDP143 Pilot Operated Pressure Surplussing Valve with Cast Steel Body

Type MR108 Direct-Operated Backpressure Regulators

Mark 60 Series. Pressure Regulators Mark 60 Pressure Regulators. Self Operated Pressure Regulators. CRN Registration Number Available

548 hydraulic separator

GP10L/GT10L GP14L/GT14L GP14M/GT14M

Modulating control valve PN16

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

PF6 Stainless Steel Piston Actuated On/ Off Valves

ACTIVAL Two-way Ball Valve with Threaded-end Connection

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

Direct-Operated Pressure & Temperature Regulating Valves

SMART SOLUTIONS FOR WATER 600 Series Hydraulic Control Valves Waterworks Irrigation

Transcription:

Pamphlet M0000 COSPECTR PRESSURE REDUCING VALVES Three-in-One Pressure Regulator, Separator, and Steam Trap

COSPECT: Three-in-One Design A Product of Advanced Fluid Control Technology Three sub-units combine to form the reliable, accurate, cost-effective COSPECT 1. SAS Shock Absorbing Spherical piston 2. SCE Super Cyclonical Effects separator 3. SST Super Steam Trap Reducing valves had remained essentially unchanged for decades conentional designs seemed good enough. But manufcturers increasingly demanded more effective process control for improved product quality; responded with this remarkable innovation. With conventional pressure reducing valves, wide variations in primary pressure cause the secondary pressure to fluctuate; this produces temperature variaton, which results in inconsistent product quality. Also, valve hunting and vibration make it difficult to accurately set precise system pressure needed. These valves are also subject to failure from the effects of rust, scale, and other impurities. In addition, conventional condensate separators do not efficiently remove condensate, reducing the productivity of steam-using equipment. applied its fluid control technology to solve these critical problems. The answer? The COSPECT an innovative design with three unique features: SAS, SCE and SST. 1

Construction The three remarkable features SAS, SCE, and SST combine into a single space-saving unit, which also simplifies system layout, piping, and maintenance. COSPECT. Three problemsolvers in one to increase productivity and improve product quality. 18 17 16 13 15 14 19 12 Part Material 1 Main body Cast iron or 2 Trap body Cast iron or 10 3 4 5 6 7 Trap cover Separator Float Trap valve seat Main valve seat Cast iron or or 1 7 8 11 9 8 9 Main valve Main valve spring 4 10 Piston 11 12 Separator screen Pilot valve spring 2 13 Pilot body Cast iron or 14 Pilot valve 15 16 Pilot valve seat Diaphragm 5 17 Coil spring Carbon steel 18 19 Adjustment screw Pilot screen 6 3 2

Three COSPECT Design Breakthoughs Provide Dry Saturated Steam at a Constant Pressure and Temperature. 1. SAS: Shock-Absorbing Spherical Piston High Stability of Set Pressure The spherical surface of this new SAS piston creates a low pressure area in the passing steam flow. This pulls the piston down, making the orfice easy to open for accurate, responsive control. The piston is also selfcentering when the valve stem tilts. As illustrated, steam flows slower through the shorter path on the left side than on the right side, creating a high pressure region on the left side and a low pressure region on the right side. This pressure difference causes the piston to self-align. The exclusive SAS design permits a smooth high velocity flow eliminating the turbulent steam flow characteristic of conventional valve designs. Pull down Self-aligning 2. SCE: Super Cyclonical Effects Separator Wet Steam at 85-90% quality Dry steam at ~98% quality 98% Separation Efficiency This unique SCE separator provides dry saturated secondary steam by effectively removing condensate and scale whith its 98% separation efficiency. This raises the heat transfer coefficient by 9% improving steam equipment productivity. The pressure reducing valve service life is extended since the effective removal of condensate and scale protects the main valve from erosion. 3. SST: Super Steam Trap Continuous Discharge and Seal-tight Shut-off Separated condensate is instantly removed by this SST continuous discharge trap. The three-point seating design and precision ground spherical ball float provides seal-tight shut-off even under no-load conditions. 3

Glossary Primary pressure: Steam pressure at the inlet of the pressure regulator. Secondary pressure: Steam pressure at the outlet of the pressure regulator. Minimum adjustable flow rate: Minimum flow that can be maintained at a constant pressure level. Set pressure: Desired secondary pressure. Rated flow rate: Maximum flow rate, at secondary pressure, that can be obtained within a given offset when the primary pressure is held constant. Pressure rise: The increase in set pressure, following steamusing equipment shutdown by closing the inlet valve to the equipment. Offset: Difference between actual secondary pressure and set pressure, when flow rate is increased from the minimum adjustable flow rate to the rated flow rate while primary pressure is held constan. Pressure Rise Following Equipment Shutdown Secondary Pressure (MPaG) Secondary Pressure 0.20 0.19 0.18 0.17 Flow Rate Characteristic Set Pressure Offset P2abs 0,05 Minimum Adjustable Flow Rate Flow Rate (Rated Flow Rate 0.05) 0.3 0.4 0.5 0.6 0.7 0.8 Primary Pressure (MPaG) Rated Flow Rate 0.9 1.0 Pressure vs. Flow Rate Primary pressure 0.2 MPaG, setting 0.1 MPaG, size 25 mm +0.1 Flow Rate (kg/h) +0.05 Setting (MPaG) 0.1 300 0 500 0.05 Offset 0.1 Above: The pressure and flow characteristic data prove stable valve performance: accurate pressure reduction is maintained even if flow varies. This test data was obtained by computer-controlled automated testing equipment. Left: After setting the secondary pressure of 0.2 MPaG when the primary pressure is 0.3 MPaG the chart illustrates the variation of the secondary pressure when the primary pressure is increased to 1.0 MPaG Steam Flow Velocity vs. Separation Rate Condensate SeparationRate (%) 95 90 10 20 30 Steam Flow Velocity (m/sec) Accuracy: ±2% Condensation: - 50 kg per hour This test data demonstrates that the SCE separator provides the exceptionally high condensate separation rate of 98.5% at a steam flow velocity of 10 m/sec. Separation rate (%) is given as: quantity of condensate discharged quantity of incoming condensate This combined with the pressure reducing function of the valve, delivers virtually % dry steam downstream. Condensate Discharge Capacities Model COS-3 Differential Pressure (kg/cm 2 ) Size Discharge Capacity (kg/h) 0.1 0.3 0.6 1 3 800 50 600 0 300 70 0.01 0.03 0.06 0.1 0.2 0.3 Differential Pressure (MPa) 2532 20 Model COS-16 Differential Pressure (kg/cm 2 ) 0.1 0.3 0.6 1 3 5 1016Size 600 300 506580 2532 1520 80 60 Discharge Capacity (kg/h) 20 10 0.01 0.03 0.06 0.1 0.3 0.5 1.0 1.6 Differential Pressure (MPa) Model COS-21 Differential Pressure (kg/cm 2 ) 0.1 0.3 0.6 1 3 5 10 21 Size 600 0 506580 2532 1520 80 60 This discharge capacity chart shows maximum hourly discharge rates of condensate 6 C below saturated steam temperature. The pressure differential is the difference between the trap primary and secondary pressures. Discharge Capacity (kg/h) 20 10 0.01 0.03 0.06 0.1 0.3 0.5 1.0 2.1 Differential Pressure (MPa) 4

1Until upper coil spring is compressed, main valve and pilot valve are held closed by main valve spring and pilot valve spring. Steam enters through passage, passes through pilot screen and enters pilot chamber. Standard Specifications Model Body Material* Connection Size Max. Operating Press. (MPaG) PMO Max. Operating Temp. ( C) TMO Primary Pressure Range (MPaG) Adjustable Pressure Range (all conditions must be met) Minimum Adjustable Flow Rate Dimensions L W H1 10 mm H 15 mm COS-3 Cast Iron ASME 20, 25 Ductile Cast Iron DIN 20, 25,, 50 20-50 0.3 0.1-0.3 0.01-0.05 MPaG 5% of rated flow rate COS-16 Cast Iron Ductile Cast Iron ASME DIN 15-25 15-15 - 25, - 1.57 0.2-1.57 10-84% of primary pressure but with minimum press. 0.03 MPaG Differential press 0.07-0.85 MPa COS-21 Ductile Cast Iron ASME DIN 15-25 15-15 - 25, - 2.1 1.35-2.1 From 0.55 MpaG to 84% of primary pressure Max. differential Press 0.85 MPa 5% of rated flow rate (for 65 - mm: 10% of rated flow rate) * COS-3 & COS-16 also available in stainless steel; contact TLV for details 1 MPa = 10 bar = 10.197 kg/cm 2 PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (MPaG) PMA: 1.57 (cast iron), 2.1 (ductile cast iron); Maximum Allowable Temperature ( C) TMA: CAUTION To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. L Size H H1 Weight** ASME Class DIN2501 (kg) 125FF (150RF) 250RF (300RF) PN25/ (15) 170161 170167 150* 1516 175 495515 285305 (20) 182172 182178 150 1617 25 190 176 188181 188 192187 160 522542 282302 2122 32 206 212 219 2527 572592 302322 209 215 222 224222 2728 50 255 255254 260 261260 230 635655 315335 4346 65 362 372371 377 378377 370* 6970 870892 410422 80 365 374374 383 384384 374* 7274 434 434434 450 450450 434* 10281050 448450 105102 ( ) ASME Class 150 RF and 300 RF do not exist for cast iron and sizes 15 mm and 20 mm ductile cast iron; machined to fit steel flanges Class 125 FF can connect to 150 RF, 250 RF can connect to 300 RF ASME Class 125 FF and 250 RF are not available for ductile cast iron Other standards available, but length and weight may vary * Not DIN length due to size of separator and steam trap ** Weight is for COS-3/COS-16 Class 250 RF/300 RF COS-21 5

2 3 When secondary pressure is set by Some steam, entering the outlet side, tightening adjustment screw, upper flows through outlet pressure passage coil spring is compressed and into a chamber below the diaphragm, diaphragm flexes, forcing pilot guide and lifts it. The position of pilot valve to open pilot valve. is then determined by the balance of Steam enters chamber above piston, the upward force on the diaphragm forcing it down. with the downward force of upper coil Main valve opens the orifice, providing steam to the secondary side. steam pressure itself adjusts the force spring. Thus the preset secondary Before entering the main valve, steam applied to the piston and the opening passes through the separator. of the main valve. Secondary pressure The angled separator blades cause the remains stable, and dry saturated steam steam to whirl and release the entrained is supplied at all times. condensate, which is discharged continuously through the steam trap. Specifications for Other COS Series Pressure Reducing Valves Model Application Body Material* Connection Size Max. Operating Press. (MPaG) PMO Max. Operating Temp. ( C) TMO ACOS-10 Air & Gas Cast Iron ASME 15, 20, 25 15, 20, 25, 32,, 50 0.9 0.1 0.9 0.05 0.7 0.05 Ductile Cast Iron DIN 15, 20, 25,, 50 VCOS Vacuum Pressure Steam Cast Iron ASME Ductile Cast Iron DIN 25,, 50 0.2 150 0.1 0.2-0.08 0.08 0.02 Primary Pressure Range (MPaG) Adjustable Pressure Range (MPaG) Min. Press. Differential (MPa) Minimum Adjustable Flow Rate 10% of rated flow rate PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (MPaG) PMA: 1.57 (ACOS-10), 0.2 (VCOS); Maximum Allowable Temperature ( C) TMA: (ACOS-10), 150 (VCOS) 1 MPa = 10 bar = 10.197 kg/cm 2 CAUTION To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range. Local regulations may restrict the use of this product to below the conditions quoted. Dimensions ACOS-10 VCOS L L 10 mm H1 H 15 mm 10 mm H1 H 15 mm ACOS-10 VCOS Size (15) (20) 25 32 50 25 50 175 190 125FF 176 206 209 255 176 209 255 L ASME Class (150RF) 250RF 170 182 188 188 222 255 260 188 255 (300RF) 170 182 192 224 261 DIN2501 PN25/ 150* 150 160 230 160 230 H 495 522 572 635 580 630 692 H1 285 282 302 315 3 360 372 ( ) No ASME standard exists for cast iron; machined to fit steel flanges Class 125 FF can connect to 150 RF, 250 RF can connect to 300 RF Other standards available, but length and weight may vary * Not DIN length due to size of separator and steam trap ** Weight is for Class 125 FF [150 RF] Weight** (kg) [14] [15] 19 23 25 25 30 45 6

881 Nagasuna, Noguchi, Kakogawa, Hyogo 675-8511, JAPAN Phone: [81]-(0)79-427-1818 Fax: [81]-(0)79-425-1167 E-mail: tlv-japan@tlv.co.jp Manufacturer Kakogawa, Japan is approved by LRQA Ltd. to ISO 9001/101 ISO 9001/ ISO 101 (M) Internet World Wide Web URL http://www.tlv.com Pamphlet M0000 Rev. 9/9 Specifications subject to change without notice.