MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS

Similar documents
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL RBK FRP FAN

INSTALLATION, OPERATION & MAINTENANCE MANUAL AXIAL UPBLAST FANS RTA, RWTA, RHTA, RB, RD, RTA SH

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP

INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS

MODEL CLS Centrifugal Filtered Supply Fans

Jet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL CNW DHK PVK

Duct Blower Cabinet Fans

Installation, Operation and Maintenance Manual

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting

DUCT BLOWER Cabinet Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

MARLEY ENGINEERED PRODUCTS OPERATING INSTRUCTIONS AND PARTS LIST

SQI Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Tubular Centrifugal Inline Fans TCN

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting

Emergency Smoke Control Centrifugal Roof Exhaust Fans

READ AND SAVE THESE INSTRUCTIONS. Centrifugal Upblast Exhaust Fan (Standard & High Pressure Exhaust) Belt Driven for Roof & Wall Mounting

Installation. Centrifugal Roof and Wall Exhausters

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

Installation, Operation and Maintenance Manual

Operation and Maintenance Manual. Series BI Centrifugal Blowers

AC/VCR Centrifugal Roof and Wall Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

DPL/DPL-AF SERIES PLENUM FANS OPERATION INSTRUCTIONS AND PARTS MANUAL MODELS: DPL/DPL-AF-12, 13, 15, 16, 18, 20, 22, 24, 27, 30, 33, 36 GENERAL SAFETY

Models TXB & TXB-W Installation, Operation, and Maintenance Manual

Model CFD Installation, Operation, and Maintenance Manual

INSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS

Model CFD Installation, Operation, and Maintenance Manual

Model CFD Installation, Operation, and Maintenance Manual

ASP/KSP Centrifugal Filtered Supply Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Models STXB,STXBW, STXBRHUL, STXBHP Installation, Operation, and Maintenance Manual

SRSH Tamper Proof Centrifugal Exhauster INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

Models TXB,TXB-W, TXB-RHUL Installation, Operation, and Maintenance Manual

ECONOMIZER FAN. Receiving and Inspection

REBEL/AQ/SEP/ETE/ETS IO&M

SECTION CENTRIFUGAL HVAC FANS

Models BVS & CM - Level 1 Construction Installation, Operation, and Maintenance Manual

SQN Centrifugal Square Inline Fans INSTALLATION, OPERATION AND MAINTENANCE MANUAL

SECTION AXIAL HVAC FANS

CFS Centrifugal Filtered Supply Fans

LO-PRO. Receiving and Inspection. Handling Lift the fan by the base. NOTICE! Never lift by the shaft, motor or housing.

INDUSTRIES AMERICAN COOLAIR CORPORATION. Centrifugal Filtered Supply Roof Ventilators TYPE CFS - TYPE SIS

DATA SHEET CP MOTORIZED PUMP UNITS 3CP1120, 3CP1130, 3CP1140 5CP2140WCS, 5CP2150W

CPL Centrifugal Plenum Fans

FCE/FCRU Fiberglass Roof Exhausters INSTALLATION, OPERATION AND MAINTENANCE MANUAL

CCP Centrifugal Plug Fans

IM Centrifugal Power Roof & Wall Ventilators. Introduction. Shipment and Receiving. Handling. Storage. Issue Date: 4-97 Rev.

Model SDB Installation, Operation, and Maintenance Manual

Models LC, L2 & L3 Installation, Operation, and Maintenance Manual

IM-210 INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS HOODED ROOF VENTILATORS UPBLAST ROOF VENTILATORS AIR PRESSURE AND SUCTION A WORD ABOUT SAFETY

TMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL


Models GED/GSD, DFE/DFS & DDE/DDS Installation, Operation, and Maintenance Manual

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

Power Roof Ventilator Installation, Operation, and Maintenance Manual. Down-blast Centrifugal Fan Utility Set Axial Fan

DESIGN GUIDELINES FANS PAGE 1 of 7

CP Pumps BD Motorized Pump Units

NSGV Direct Drive Pressure Blower (AF) Aluminum Housing & Wheel

Centrifugal Upblast Power Roof Ventilators

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

IMH Industrial Material Handler INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Tube Axial Fan Page Specifications & Dimension Data Performance Data

QMX Mixed Flow Inline INSTALLATION, OPERATION AND MAINTENANCE MANUAL

FCP Fiberglass Blower INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Axial Roof Ventilators & Tubeaxial Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

Fixed Pitch Vane Axial Fan

Electro-Brake 375, 475, 650, 825, 1000, 1225

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

Installation, Operation and Maintenance Manual

Upblast Propeller Roof Fans

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

BCFS Belt Driven Centrifugal Filtered Supply Fans

Model CWD Installation, Operation, and Maintenance Manual

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Propeller Upblast Roof Fans

Installation Instructions

Advanced Technology Tension Clutches

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com

SECTION HVAC POWER VENTILATORS

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

F O R M. Rotating Biological Contractor Drives Installation and Maintenance Manual. 8368E Revised October Table of Contents.

TB Series Brakes Tension Control System

Advantage Fan 36" and 48"

/ Marley Ultra Low-Noise Fan / User Manual

TU-WAY ROOF VENTILATORS

AC Induction Motors. Installation and operating instructions

Series Base mounted pump. Installation and operating instructions

Amerigear SF Spindle

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

HOOD EXHAUST OR SUPPLY PROPELLER FAN

ROTO-CON RONK ELECTRICAL INDUSTRIES, INC. NOKOMIS, IL FIELD INSTALLATION & OPERATION INSTRUCTIONS

IMPORTANT! READ BEFORE PROCEEDING! PHR Axial Flow Hooded Roof Ventilators

Type VA Vanax Fans. Models VA, VAD, & VAB

IM-230 AIR KITS INSTALLATION MAINTENANCE, OPERATING INSTRUCTIONS

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

11-24 CKCP: KCM: 7-34 CKCM:

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

Transcription:

READ AND SAVE THESE INSTRUCTIONS 9668-D Heinrich Hertz Drive, San Diego, CA 92154 PH: 619-946-1224 MODEL VBO-HV & VBO UPBLAST PROPELLER ROOF FANS SHIPPING INSPECTION Romlair Model VBO-HV & VBO fans are thoroughly inspected and test run at the factory.however, damage may occur during handling and shipping. Upon receiving unit, check for any damage and report it immediately to the shipper. Also check to see that all accessory items are accounted for. INSTALLATION When lifting the fans into place, attach an acceptable chain or strap to the four welded corner supports. It is important not to lift the fan by the motor, windband, or accessories. INSTALLATION AND MAINTENANCE INSTRUCTIONS Welded Corner Supports (4 Corners) Carefully move the fan to the desired location and fasten securely to the roof curb. Use fasteners to suit construction and material. Fasteners are not supplied by Romla Ventilator Company. SERVICE ACCESS Removable Windband - The windband can easily be removed by removing the bolts from the windband mounting brackets. Access to the fan bearings, fan shaft, driven pulley, and propeller can be gained through the butterfly dampers. The dampers can also be easily removed to allow more open access to the interior parts of the fan. Motor Cover - A removable motor cover provides easy access to the motor, belt, and drives from the roof. ELECTRICAL CONNECTIONS The motor s amperage and voltage rating must be checked for compatibility to the supply voltage prior to final electrical connection. Consult local and national electrical codes regarding supply wiring requirements. Emergency Smoke Removal Installation - Electrical supply must be out of the airstream. Isolated power supply may be required so that if power is cut to the building in a fire, the fans will be able to operate. Consult the local and national electrical codes regarding emergency smoke removal fan applications. PRE START-UP CHECKS Check all fasteners for tightness. Movement may occur during shipment and it is very important that all fasteners are secure, This is very important on the bearings and propellers. Manually rotate the propeller by hand to make sure it turns freely and does not make contact with the fan housing. Direction of propeller rotation is critical. Reversed rotation will result in poor air performance, motor overloading and possible burnout. Rotation should correspond to the rotation arrow located on the fan propeller. 1

WARNING Disconnect and secure to the off position all electrical power to the fan prior to inspection or servicing. Use Extreme caution when working around the fusible link damper lifter. The lifters could release accidently. The fans have extra heavy duty damper lifters under very high spring tension. Because of safety concerns, lifters must be secured to prevent accidental release. See Figure 2 for details on securing the lifter arms. FAILURE TO COMPLY WITH THESE SAFETY PRECAUTIONS MAY RESULT IN SERIOUS INJURY OR DEATH Model VBO-HV with high temperature option - UL Listed For Power Ventilators For Smoke Control Systems. Figure 2 WARNING! These fans have extra heavy duty fusible link damper lifters designed for a 10 lb sq ft loading. These lifters are under very high spring tension and must be secured with the safety bolt so they can not be accidentally released when servicing the fan. These damper lifters are located under the damper blades. Figure 2 shows where the safety bolt must be placed when the fan is being serviced. It also shows where to store safety bolt. Extreme caution must be taken when working around these damper lifters. FAILURE TO COMPLY WITH THESE SAFETY PRECAUTIONS MAY RESULT IN SERIOUS INJURY OR DEATH. CARE AND MAINTENANCE Recommended Torque for Setscrews/Bolts (IN/LB.) Good fan maintenance requires regular and systematic inspection of all fan parts. Severity of the application should determine frequency of inspection. SIZE SETSCREWS RECOMMENDED TORQUE M IN. MAX. HOLD DOWN BOLTS SIZE WRENCH TORQUE NO. 10 28 33 3/8"-16 240 1/4" 66 80 1/"-13 600 5/16" 126 156 5/8"-11 1200 3/8" 228 275 3/4"-10 2100 1/2" 504 600 1"-8 3000 FASTENERS AND SET SCREWS Normal fan vibration can loosen fastens. Periodic inspection should include checking all fasteners and set screws. Check the propeller fasteners for tightness. 7/16" 348 384 7/8"-9 2040 5/8" 1104 1200 1-1/8"-7 4200 3/4" 1440 1800 1-1/4"-7 6000 LUBRICATION-PILLOW BLOCK BEARINGS The bearings can be operated for long times without supplement of the grease. See the following Greasing Interval Table. Because the model VBO-HV is designed for high temperature emergency exhaust, it is important to be relubricated with special high temperature grease. Romla uses SealMaster Goldplex-HT. GoldPlex-HT is classifed as a NLGI Grade 2 lithiumbased grease suitable for applications with temperatures up to 400 F. 2

LUBRICATION-PILLOW BLOCK BEARINGS (CONTINUED) Use following table as a guide for greasing intreval. Model VBO-HV and VBO fans have extended lubrication lines as standard. The grease fittings are located on the exterior of the fan housing under the belt tube.always clean the fitting before relubrication. It is best to lubricate the bearings while the fan is rotating. Do not unseat the bearing seals by over lubricating. Excessive grease can burst seals thus reducing the bearing life. Use no more than three injections with a hand operated grease gun. Operating temperature of bearing C F Clean Greasing interval Environmental condition Dirty Very dirty heavy humid 50 122 3 years 6 months 3 months * 70 158 1 year 2 months 1 month 100 212 3 months 2 weeks 1 week 120 248 6 weeks 1 week 3 days 150 302 2 weeks 3 days Daily *Normal bearing temperature LUBRICATION INSTRUCTIONS FOR BALL BEARING MOTORS (WITH GREASE FITTINGS) This is a ball bearing motor. The bearings have been given initial lubrication at the factory, and are adequate for a long period of operation without relubrication. Lubrication is intended only when fittings are provided. Regreasing will vary depending on motor size, speed, and environment. PROCEDURE FOR LUBRICATION If motor is equipped with Alemite fitting, clean tip of fitting and apply grease gun. Use 1 to 2 full strokes on motors in NEMA 215 frame and smaller. Use 2 to 3 strokes on larger motors. CAUTION: Keep grease clean! RELUBRICATION INTERVALS FOR MOTORS WITH GREASE FITTINGS The following intervals are suggested as a guide. HOURS OF SERVICE PER YEAR SUGGESTED RELUBE INTERVAL 5000 Every 5 years Continuous Normal Application Once a year Continuous In high ambient, or dirty or moist location: or where motor is idle for 6 months or more, and applications with high vibration or where shaft end is hot (pumps-fans) Every 6 Months LUBRICANT A high grade ball or roller bearing grease should be used. Recommended grease for standard service conditions is Polyrex EM (Exxon Mobil). Equivalent and compatible grease include: Texaco Polystar, Rykon Premium #2, Pennzoil Pen 2 Lube and Chevron SRI. 3

BELTS AND PULLEYS Drive pulleys must remain in proper alignment after adjustments are made. Figure 4 illustrates correct and incorrect pulley alignment. Figure 3 Improper belt tension or misaligned pulleys frequently cause premature belt failures. The V-belt tension should be at the lowest tension where the belts will not slip at peak load. For proper tension, a deflection of approximately 1/4 per foot of center distance should be obtained by firmly pressing the belt. Refer to Figure 3 Belt tension should be checked during the first 24 hours of operation and re-adjusted if required. Loosen or tighten the nuts on the threaded motor supports to make the required tension adjustments. Figure 4 BEARING REPLACEMENT 1.To gain access to the fan, remove the windband and damper assembly. 2. Loosen the mounting bolts on the adjustable motor plate so that the drive belts can be removed. 3. Remove the propeller from the fan shaft. This is done by remving all three capscrews from the propeller and hub assembly. Start the capscrews into the threaded holes in the bushing flange. Tighten each bolt part of a turn successively to force the propeller off the tapered bushing. Pull the bushing off the fan shaft. 4. Remove the metal bearing cover and the bearing hold down bolts. This will allow you to remove the fan shaft, fan bearings, and the driven sheave from the fan as one assembly. 5. To aid the reassembly, measure and record the location of the bearings and sheave on the fan shaft. 6. Install the pulley in the correct location on the shaft. 7. Place the new bearings on the shaft loosely. Drop mounting bolts in place, snug them and adjust the position of shaft. 8. Center both shaft ends in housing using the clearance in the mounting holes for horizontal adjustment and shims if necessary for vertical adjustment. 9. Tighten the bearings on the propeller end first, then tighten the other bearing. 10. Tap the locking collar lightly at the end away from the propeller. The shaft should slide freely end to end. 11. The final step is to align the shaft with the motor sheave and tighten the locking collars. 12. If the fan is supplied with a lubrication line, attach it to the grease connection. 13. Install the propeller on the fan shaft and adjust bearing position to center the propeller in the fan housing. If the fan shaft is dropped, it may get bent and cause unbalanced operation of the fan. Place a support through the hub for lifting, making sure not to damage the finished bore of the propeller. PROPELLER AND SHAFT REPLACEMENT CAUTION. Do not allow the propeller to rest it s entire weight on the fan blades. Use caution if lifting the propeller by chain. Use sufficient protection to prevent the scoring of the shaft or injury to the propeller. 4

Many Romlair belt driven fans are furnished with variable-pitch motor sheaves. On some of these fans sheaves may be adjusted for lower fan speeds without concern of over-loading motors. When adjusting sheaves to increase fan speed, check motor current to be sure motor is not overloaded. Keep motor current within nameplate and service factor ratings. The sheaves used are the VL,VM, and the VP Type. These sheaves are easily adjusted and come in various styles depending upon the size drive and motor shaft. The following steps should be taken to adjust the pitch diameter: 1. Release the belt tension and remove belt or belts from the sheave. ADJUSTING VARIABLE PITCH SHEAVES 2. Loosen the set screw and remove key holding adjustable half of the groove. 3. Screw adjustable half of sheave out for a smaller pitch diameter (decreased speed), or in for a larger pitch diameter (increased speed). Each one-half turn will change the pitch diameter one tenth of an inch. Adjust two-groove sheaves the same amount on each groove. 4L or A belts will operate satisfactory with the sheave fully closed to a maximum of five full turns open. 5L or B belts will operate satisfactory with the sheave one full turn open to a maximum of six full turns open. 4. Replace the key and tighten set-screw to lock sheave half in position. 5. Replace the belts and tighten to proper tension. INSTALLATION INSTRUCTIONS FOR PROPELERS EQUIPPED WITH BROWNING MALLEABLE IRON SPLIT TAPER BUSHING Romlair cast aluminum and steel fabricated propellers are furnished with split taper bushings for mounting the propeller to the shaft. When properly assembled, the bushings grip the hub with a positive clamping action. A. Bushing barrrel and bore of propeller are taperedthis assures concentric mounting and a true running propeller. enough to engage threads in tapped holes on propeller. Do not use a wrench at the time. The bushing should be loose enough in the propeller to move slightly. Be sure shaft and keyway are clean and smooth. Check key size with both shaft and bushing. B. Capscrews, when tightened, lock bushing in propeller. Use plated cap-screws threaded full length. BUSHIN- G NO. DIA. LENGTH TORQUE FT. LBS. H P-1 P-2 Q-2 R-2 1/4-20 5/16-18 5/16-18 3/8-16 3/8-16 1-1/4" 1-1/2" 1-3/4" 2-1/2" 3" 7-1/2 13 13 24 24 Slide propeller and bushing assembly onto the shaft, making allowance for end play of shaft to prevent rubbing. Do not force propeller and bushing onto shaft. If it does not go on easily, check shaft, bushing and key sizes. C. Bushing is split so that when the locking capscrews force the bushing into the tapered bore, the bushing grips the shaft with a positive clamping fit-this will withstand vibration and punishing loads without being loosened. D. Propeller and bushing assembly is keyed to shaft and held in place by compression. Put bushing loosely into propeller. Do not press or drive. Start cap-screws by hand, turning them just Tighten capscrews progressively with wrench. Do this evenly as in mounting an automobile wheel. Take a part turn on each capscrew successively until all are tight. These capscrews force the taper bushing into the hub which in turn compresses the bushing onto the shaft. This makes a positive clamping fit. The torque must not exceed that shown in table at left. WARNING: Do not attempt to pull bushing flange flush with hub end. There should be 1/8 to 1/4 clearance when tightened. 5

TROUBLE SHOOTING PROBLEM Low Capacity or Pressure CAUSE Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the propeller. Poor fan inlet conditions. There should be a straight clear duct at the inlet. Improper propeller alignment. Damaged or unbalanced propeller. Belts too loose: worn or oily belts. Excessive Vibration and Noise Overheated Motor Speed too high. Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the propeller. Bearing need lubrication or replacement. Motor improperly wired. Incorrect direction of rotation. Make sure the fan rotates in same direction as the arrows on the propeller. Cooling air diverted or blocked. Improper inlet clearance. Incorrect fan RPM's Incorrect voltage. Overheated Bearings Improper bearing lubrication. Excessive belt tension. WARRANTY The Romla Ventilator Company warrants this equipment to be free from defects in material and workmanship under normal use and service for a period of one year from date of delivery. During the warranty period if any parts prove to be defective, they will be repaired or replaced free of charge at factory option: If upon receipt of written authorization they are delivered prepaid to the factory. This guarantee does not cover any damage caused by neglect of lubrication, accident or overload, improper installation, nor does it cover the cost of repairs made or attempted outside the factory, without authorization from Romla Co. Electric motors are guaranteed only to the extent of the motor manufacturer s warranty. Romla Co., is not responsible for the cost of removal of the defective product or part, or the installation of the repaired or replaced products or part. Correction of any verified defects by repair or replacement shall constitute fulfillment of this warranty. VENTILATION PRODUCTS 9668-D Heinrich Hertz Drive, San Diego, CA 92154 PH: 619-946-1224 6