INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

ROMAN TUB 3 VALVE LONG STEM AND TRIM INSTALLATION INSTRUCTIONS Valve Body No Trim Kit for Model No s: 1047, 1707, 1727

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions 1662SG SG.222

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4020B

INSTALLATION INSTRUCTIONS

Installation Instructions 1662SG SG.224

PILLOWS DECK-MOUNT BATH FAUCET WITH FLUME SPOUT

Installation Instructions 1662SG SG.223

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation Instructions

Installation Instructions

Deck-Mounted Bath Set with Diverter

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Installation Instructions Series Series

Installation Instructions

Installation Instructions

Britt Single Handle Commercial Kitchen Faucet

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Pressure Balancing Valve Shower or Tub/Shower Installation Instructions

Installation. Tools. Single Handle Kitchen Faucet With Optional Spray. Maintenance. Safety Tips. Important Points. Need Help? For Model:

Installation Instructions

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

INSTALLATION INSTRUCTIONS FOR DECK TUB SETS with HAND SHOWER Valves Numbered: &

Single Lever Pull-Out Kitchen Faucet

INSTALLATION MANUAL Aplos Single Handle Vessel Bathroom Faucet KEF I toll free: I Kraus USA Inc. I REV

Installation Instructions

SERIN MONOBLOCK LAVATORY FAUCET with

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

INSTALLATION, OPERATION & SERVICE INSTRUCTIONS

Installation Instruction for Valve: DFPHY.ID Trim Application: Pressure Balance Tub & Shower

Installation Instructions / Warranty

Installation Instructions

Geo Arch Single Lever Pull-Down Kitchen Faucet With Soap Dispenser

Artec Pro Single Handle Commercial Kitchen Faucet

1/7 HANDLE TRIM INSTALLATION

CW-2651 (WL1100) CB-2651 (BL1100)

INSTALLATION INSTRUCTIONS STUDIO S

FOR TECHNICAL ASSISTANCE

Installation Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

Installation For Service Only

Aquila Single Lever Vessel Faucet

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Installation IMPORTANT! Aerada 900 Series Futura Faucet With Accu-Zone (AZ) Infrared Control

5 5 8 " Description Part # Description Part # O-ring. Tee Connector. Widespread Handle * 1.5 GPM Flow Restrictor PM-080

ROMAN WATERFALL BATHTUB FAUCET

1 - S-2251 Showerhead 6 - S-2288 Showerhead AP - Anchor Plate (S-2280 Showerhead Only)

Installation Instructions

Basin Set INSTALLATION INSTRUCTIONS

Single Lever Pull-Out Kitchen Faucet

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

E-Mini Thermostatic Valve with Shut-Off or with Positive Shut-Off 2-Way Diverter

Installation Guide. Single-Control Bath and Shower Trim A K T948, K T949, K T950 K 951, K 952

INSTALLATION INSTRUCTIONS PATIENCE

Installation Instructions

Single Lever Pull-Down Kitchen Faucet

Installation Instructions

INSTALLATION MANUAL IMPORTANT CONSIDERATIONS TECHNICAL INFORMATION. Tools you may need

Installation Instructions

Installation Instructions Series

FREESTANDING FAUCET LS5B/LS5C INSTALLATION INSTRUCTIONS.

Ramus Single Handle Lavatory Faucet

FOR TECHNICAL ASSISTANCE

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Installation Instructions

Supplies Required. Teflon Tape Allen Key Wrenches Screwdriver 1/2" NPT Brass Pipe Plug Adjustable Wrench IMPORTANT!

Installation Instructions

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

Installation Instructions

See Installation Guide

Installation Instructions

Installation Instructions

Transcription:

INSTALLATION INSTRUCTIONS SHOWN WITH TUB-FILLER SET (NOT INCLUDED) MODEL: VINTAGE 690090 (RH-576L) 690040 (RH-576) REV C

Restoration Hardware Diverter Trim Kit Product Size Specification Diagram Dimensions are in inches and Approximation of a Typical Installation Recommended Deck Hole Sizes: -/4" Diameter for Hand-Held Flange Assy and -/" Diameter for Diverter Flange Assy Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

Common tools needed:. Adjustable Wrench Plumbers Putty Pipe Cutter Solder & Torch Thread Sealant Installation Instructions We Recommend Installation by a Licensed Plumbing Professional Diverter Assembly Apply thread sealant (e.g. Plumber s tape) to hand shower ADAPTER () male threads and tighten onto diverter VALVE BODY (). Remove upper FLANGE NUT () and install diverter BODY () from underside of deck. Reattach upper FLANGE NUT () onto diverter valve. Note: place FLANGE NUT () on finished deck surface. See Figure a. Secure diverter valve BODY () to deck by tightening lower FLANGE NUT (4). Cut diverter STEM (5) to -/4 from finished deck. Cut ALL THREAD (6) -5/8 shorter than STEM (5). 6 5 -/4 Figure a 4 Figure Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

. Deck Flange Assembly Install hand shower DECK FLANGE HOUSING () though hole on finished deck surface, install RUBBER () and STEEL () washer and secure with FLANGE NUT (4). Place plastic HOSE GUIDE (5) onto lower portion of housing threads. 4 Figure 5 4 Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

. Water Supply Connections Note: Piping and plumbing fittings are not supplied. It is recommended that all solder operations be performed prior to attaching fittings to valves. Usage of access panel(s) is highly recommended. The most common methods of water connections are one of the following: a. Flexible Stainless Steel braided hoses i. Access panel(s) are required by plumbing code (UPC). ii. No soldering or brazing is required. b. Rigid Copper tubing / piping i. Requires soldering or brazing. ii. All soldering must be performed a minimum of 4 from valve ports. iii. Brazing must be performed before attaching to valves. Make all necessary connections as shown in Figure. Feed braided hand shower HOSE () through DECK FLANGE () and attach one end of hose into the hand shower OUTLET () of diverter valve. Attach hot/cold supply lines to appropriate valve body. The outlet from each valve body must be joined (ie. mixed) then attached to inlet at bottom of diverter valve. Connect /4 side outlet of diverter valve to tub spout fitting as shown. / NPT Note: Some states require a ASSE 06 approved Tempering Valve installation with this product. See disclaimer following for proper installation. HOT INLET Figure COLD INLET 5 Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

Disclaimer Regarding Roman Tub with Hand Spray To conform to local codes and ordinances, all Roman tub with hand spray products should be used in concert with an ASSE 06 approved tempering valve to reduce the hot water supply to a safe temperature not exceeding 0 F (4 C). Important: Water temperatures in excess 0 F (4 C) are dangerous and may cause scalding, severe injury of death! Tempering valve should be installed and adjusted by a licensed contractor per the valve manufacturer installation instruction, and in accordance with local codes and ordinances. In general, key characteristics to ensure a tempering valve to work best with Roman tub with hand spray products shall be as follows: Tempering valve should be used prior to the Roman tub product to reduce the hot water supply to a safe temperature. To ensure sufficient water flow through the tub spout, tempering valve should be capable to handle a flow rate of 0 gpm or more. Tempering valve should include inlet filter washer and check valves in both the hot and cold water inlets to protect against cross flow. Pressure - Temperature - Flow Rate Minimum supply pressure static: 0psi (07 kpa) Inlet temperature: hot inlet, 0 F 80 F (49 C 8 C) cold inlet, 9 F 85 F (4 C 9 C) Temperature out: Field range: 80 F -0 F (7 C 49 C), adjustable. Accurate within +/- F (.7 C) Maximum temperature: 00 F (9 C) Maximum pressure: 50psi (0. bar) Minimum flow: 0.5 gpm (.9 lpm) @ 0.8psi (0.55 kpa) Maximum flow: 0 gpm (76 lpm) @ 5psi (86 kpa) * TEMPERING VALVE INLET FOR HOT WATER SUPPLY INLET FOR COLD WATER SUPPLY *Note: Valve should be installed in a location where it is accessible for cleaning or service. Due to the effects of various water conditions, periodic verification of outlet water temperature is required. 6 Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

4. Handle Shower Assembly Install DECORATIVE RING () to threaded DECK FLANGE (). Attach braided hose, from diverter, to hand shower DECORATIVE HOSE () and assembly. Turn on water supply, check for leaks and make any final adjustments required. 5. Handle Assembly Figure 4 Turn VALVE STEM (7) to OFF position. Place ESCUTCHEON (6) onto VALVE STEM (7) and thread BONNET (5) until snug against ESCUTCHEON (6). Place HANDLE (4) onto VALVE STEM (7). Check alignment, if necessary reposition handle on stem or rotate body for proper alignment. DO NOT loosen cartridge stem. Secure HANDLE (4) into place by threading SCREW () into STEM (7). Place CAP () onto HANDLE (4). Remove adhesive backing from BUTTON (), align and press onto CAP (). Note: Allow minimal space between HANDLE (4) and BONNET (5). 5 4 6 7 Figure 5 7 Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

6. Test Installed Faucet With handles in the OFF position, turn on water supplies and check all connections for leaks. Using a thin blade screwdriver, remove AERATOR () from SPOUT (). Open both hot and cold valves and allow water to run for several minutes to flush debris from installation. Turn water OFF and reattach AERATOR () to SPOUT (). /4 to / = warm; / to /4 = hot Figure 6 8 Technical support: -866-47-507 Customer Service: -877-747-467 RH-576 REV C

Care and Cleaning The lustrous finish on your Restoration Hardware Bathware fixture should be treated with care. Improper handling or cleaning can damage the surface of any metal finish. Use a soft cloth to wipe clean. Avoid harsh abrasive cleaner. Water contains lime and other mineral deposits that will be left on the surface after the water has evaporated. You can prevent these deposits from forming by always wiping the fixture dry immediately after use. Technical Support and Customer Service For technical support in the installation of your Restoration Hardware Bathware fixture, please call -866-47-507 weekdays between the hours of 7:00am and 4:00pm PST. For other questions regarding your order, to order additional components of the Restoration Hardware Bathware Collection, to order replacement parts, or to address warranty issues, please contact Restoration Hardware Customer Service at -877-747-467. 9 EN-069 RH-576 REV C