Integra Pneumatically Operated Valves

Similar documents
Integra Manually Operated Distribution Valves

Integra Pneumatically Operated Distribution Valves

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

CR8 Manual Multi-turn Valve

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

Flarelock II Tube Fitting

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

InVue Electronic Flowmeter, NT4400

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

Now available. in size. PrimeLocK Fittings. A premium PFA fitting for high-purity and corrosive chemical applications

NT Flowmeter, Model 4401

Flaretek Tube Fitting Heated Flare and Assembly Procedures

CRITICAL MATERIALS HANDLING PRIMELOCK FITTINGS

FluoroLine Ultrapure PFA Tubing

CRITICAL MATERIALS HANDLING FLUOROGARD RS RESIST STRIPPING FILTERS

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

NOWPak Canister Dispense Connector

NT ELECTRONIC FLOWMETER, MODEL 4400

KHR Series Regulators

Optimizer Point-of-use Photochemical Filters

AirHawk Gauge and Alarm Assembly

DP Series Diaphragm Valve Installation and Maintenance Instructions

Overview CHEMLOCK PFA HOUSING. Space-saving housing solution enabling hassle-free cartridge changeouts and reduced exposure to chemicals

RINSEGARD HP AND HPX. Simultaneously removes trace levels of positively charged ions and fine particles in ultrapure DI water

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

CRITICAL MATERIALS HANDLING PROCESSGARD PES CARTRIDGE AND DISPOSABLE FILTERS

InVue Electronic Flowmeter, Model NT4400

BETTIS SERVICE INSTRUCTIONS DISASSEMBLY AND REASSEMBLY FOR CB-SR-S SEISMIC SPRING RETURN SERIES PNEUMATIC ACTUATORS

Mounting and Operating Instructions EB 8053 EN. Series 250 Type and Type Pneumatic Control Valves

Finding Top Center Position for No. 1 Piston. Set The Top Center Position By Temporary Marks On Type 1 Engines and 9RM Engines

Fisher 657 Diaphragm Actuator Sizes and 87

Series 250 Pneumatic Control Valves Type and

Transmission Overhaul Procedures-Bench Service

Packing Replacement Kit for Flowrite VF 599 Series Valves

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

Back Pressure Regulator

CRITICAL MATERIALS HANDLING TORRENTO AT SERIES FILTERS

INSTALLATION INSTRUCTIONS

Pressure Relief Valve Maintenance Manual

Hard Seat Fluid Pressure Regulator

45 VALVE SERIES. 2-Position 4-Way 5-Ports, Installation & Service Instructions. Valve with Stem Operator, Installation & Service Instructions

Anderson Greenwood Series 800 POSRV Installation and Maintenance Instructions

Valtek Spring Cylinder Linear Actuators

18SP597 Series 60 Right-Side EGR Bolt-Together System to a Spherical Joint Tube-and-Shell Cooler with Pneumatic Actuator Valve

Maintenance Information

INSTRUCTION MANUAL AND PARTS LIST FOR SERIES 8L-630J AND 630M WARNING

Escape Cylinder and Valve

OPERATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

INSTALLATION INSTRUCTIONS South Highway 11 Westminster, SC Toll Free (888) (864) FAX (864)

Calibration and Switching Module. User s Manual. A Swagelok Pre-Engineered. Subsystem. Pre-engineered subsystems available in weeks, not months.

INSTALLATION INSTRUCTIONS

Maintenance Information

INSTALLATION INSTRUCTIONS REPAIR SEAL KIT Survivor 35

Miniature Soft Seat Fluid Pressure Regulator

PRODUCT SERVICE MANUAL For G6D-187, 218, 250, 275 and 312 PUMPS

1999 F-150/250 Workshop Manual

DISASSEMBLY AND ASSEMBLY

1.28 ACCESSORY DRIVE. Accessory Drive Assembly Related Parts (Former Design) SERIES 60 SERVICE MANUAL. 1. Locknut 8. Drive Gear

REPAIR PROCEDURES MANUAL

SERIES 90/91 R PNEUMATIC ACTUATOR OPERATION AND MAINTENANCE MANUAL. The High Performance Company

Type N550 Snappy Joe Emergency Shutoff Valves

Gate Valve Maintenance & Adjustment Procedures

Feature Advantage Benefit. Excellent chemical compatibility Better particle removal performance than polypropylene media

TUNE-UP KIT INSTRUCTIONS

Firehawk Second Stage Regulator Fire Service

Maintenance Information

J Flow Controls Model Numbering

EP-2 Three-Piston Pump

IOM Manual. IOM Manual. Series 20/21.

INSTALLATION INSTRUCTIONS

Chevy HD Recoil Traction Bar System. Part#: ,

Firehawk Responder Second Stage Regulator

O-Ring/Backup Ring Kit

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Removal and Installation of Fuel Injection Pumps

Fisher 2052 Diaphragm Rotary Actuator

18SP596 Series 60 Right-Side EGR Bolt-Together System to a Spherical Joint Tube-and-Shell Cooler with Hydraulic Actuator Valve

Maintenance Information

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

155 CARTRIDGE SINGLE SEAL

INSTALLATION INSTRUCTIONS

CP-1, CP-2, CP-2L & CPD-2 Series Overhaul

Encore Manual Powder Spray Gun Trigger Switch Replacement

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

INSTALLATION INSTRUCTIONS

EP-2 Si Three-Piston Pump

2017 Ford Super Duty Recoil Traction Bar System. Part#:

INSTALLATION INSTRUCTIONS

Integrated Flow Controller, Model NT6500

SID REAR SERVICE GUIDE

Valtek VL-HC Spring Cylinder Linear Actuators

DO NOT INSTALL, OPERATE, OR MAINTAIN AN ATI PRODUCT UNLESS TRAINED AND QUALIFIED IN PRODUCT AND ACCESSORY INSTALLATION, OPERATION AND MAINTENANCE.

BETTIS ACTUATOR & CONTROLS SERVICE INSTRUCTIONS FIELD CONVERSION OF SPRING CARTRIDGE FAIL DIRECTION CLOCKWISE TO COUNTER-CLOCKWISE OR THE INVERSE

2006 SID SERVICE GUIDE

Transcription:

P/N 0-025696 REV. D 09/7 INSTRUCTION SHEET Integra Pneumatically Operated Valves ", 2-way, normally open, normally closed, sampling pneumatic designs; 4" 2-way, normally open, normally closed designs REPAIR INSTRUCTIONS For models: " 2-way normally open: DS6-2U-* " 2-way normally closed: DS6-2C-* " Sampling normally open: DS6-SU-* " Sampling normally closed: DS6-SC-* 4" 2-way normally open: DS20-2U-* 4" 2-way normally closed: DS20-2C-* REPAIR PROCEDURE DISASSEMBLY This procedure describes how to disassemble both normally open and normally closed valves. WARNING: Pneumatic distribution valves contain strong springs that could cause injury if the disassembly or assembly procedure is not followed. Please read and understand all instructions before beginning. P5 O-ring P4 or OM3 o-ring P Spring P9 O-ring P0 O-ring P2 Bellows P20 Outer cap P4 Actuator body P6 or OM Piston P8 O-ring (brown) P3 Retainer P5 Stem/ sleeve assembly P Valve body Vent port Figure. Normally open valve.

P5 O-ring P3 Spring P Spring P6 or OM Piston P8 O-ring (brown) P0 O-ring P2 bellows Figure 2. Normally closed valve. P20 Outer cap P4 Actuator body P2 Spring P4 or OM3 O-ring P9 O-ring P3 Retainer P5 Stem/ sleeve assembly Vent port Screw. To become familiar with the components in the valve assembly, refer to Figure (normally open valve) and Figure 2 (normally closed valve). 2. For valves that can be removed from the line, mount the preload fixture (T2) into a vise or fasten to work bench. For valves that are installed in-line and cannot be removed, have one person hold the fixture while another torques the wrench (see Figure 3). If the valve is mounted to a base plate and cannot be removed, remove fixture base plate and have one person hold the fixture while another removes the screw assembly from the preload fixture (T2). 3. Place the valve body stop in the upper position. Loosen the adjustment screws for both port stops. Assemble the fitting nuts onto the valve ports to protect the threads. Place the valve in the preload fixture with the body in contact with the body stop and the port stops in contact with the valve ports. Tighten the adjustment screws on the port stops and secure the valve in place by tightening the wingnuts on the port hooks. 4. Tighten the screw on the preload fixture (T2) until it contacts the valve actuator body (P4). After contact with the actuator body (P4), turn the screw an additional ½-turn. Do not overtighten. Screw assembly T Outer cap wrench Valve body stop Port hooks T2 Preload fixture with small adaptor (see Setup Table) Upper nest Fixture baseplate T5 Large adaptor (see Setup Table) T6 Spacer plate (see Setup Table) Port stops Figure 3. 2 P/N 0-025696 Rev. D 09/7 Entegris, Inc.

5. Position the outer cap wrench (T) onto the outer cap (P20). Align the pins on the outer cap wrench (T) with the holes in the outer cap (P20). 6. Loosen and unthread the outer cap (P20) completely by turning it counterclockwise with the outer cap wrench (T). 7. Loosen the screw on the preload fixture (T2) and remove the screw assembly from the preload fixture (T2). 8. Remove the outer cap (P20) and actuator body (P4) from the valve. 9. Normally closed valve a. Remove the springs (P, P2 and P3). Save for assembly if only installing the Omron sensor kit. b. Remove the piston (P6), stem (P5) and bellows (P2) assembly by carefully applying air pressure to one of the media ports on the valve body while blocking the other. The applied air pressure will force this assembly out of the valve body. Cover the valve to prevent possible chemical spray and point piston away while applying pressure. Do not exceed 68.9 kpa (0 psig). c. For Omron kit only, disassemble and discard the piston (P6) and its o-ring (P4), and skip to step 9 of Assembly repair procedure. d. Disassemble the piston (P6) and retainer (P3) from the stem (P5) and bellows (P2) assembly by unthreading the piston (P6) counterclockwise while firmly holding the poppet of the bellows (P2). e. Slide the retainer (P3) off the stem (P5). f. Discard bellows (P2), stem (P5) and springs (P, P2 and P3). 0. Normally open valve a. Remove the piston (P6), stem (P5), spring (P) and bellows (P2) assembly by carefully applying air pressure to one of the media ports on the valve body while blocking the other. The applied air pressure will force this assembly out of the valve body. Cover the valve to prevent possible chemical spray and point piston away while applying pressure. Do not exceed 68.9 kpa (0 psig). b. For Omron kit only, disassemble and discard the piston (P6) and its o-ring (P4), and skip to step 9 of Assembly repair procedure. c. Disassemble the piston (P6), spring (P) and retainer (P3) from the stem (P5) and bellows (P2) assembly by unthreading the piston (P6) counterclockwise while firmly holding the poppet of the bellows (P2). d. Slide the retainer (P3) off the stem (P5). e. Discard bellows (P2), stem (P5) and spring (P). REPAIR PROCEDURE ASSEMBLY. Thoroughly clean the valve body (P) with isopropyl alcohol (S) and allow it to dry. 2. Apply a thin film of lubricant (P2) to the inside diameter of the bellows (P2). Do not get lubrication on the bellows thread or the flat area surrounding it. 3. Being careful not to damage the gland, remove each o-ring from the following components and replace with the o-ring indicated: a. Actuator body (P4) O-ring (P5) black b. Piston (P6) O-ring (P4) black c. Retainer (P3) O-ring (P8) brown O-ring (P9) black O-ring (P0) black 4. Place the new bellows (P2) into valve body (P) and push the external seal of the bellows into the groove in the body. Entegris, Inc. P/N 0-025696 Rev. D 09/7 3

5. Thread the smaller flanged end of the stem/sleeve assembly (P5) into the bellows (P2) so that it is just tight. Do not overtighten. 6. Lubricate all the o-rings (P8, P9 and P0) on the retainer (P3) with lubricant (P2). 7. Place the retainer (P3) onto the stem/ sleeve assembly (P5) so the black o-ring (P0) is facing the bellows (P2) and push it down in place. 8. For normally open valves only, place the spring (P) into the retainer (P3). (Skip this step for normally closed valves.) 9. Thread the piston (P6 or OM for Omron kit) onto the stem/sleeve assembly (P5). The piston should just contact the stem. Do not overtighten. 0. Lubricate piston o-ring (P4 or OM3 for Omron kit) with lubricant (P2).. For normally closed valves only, place the springs (P, P2 and P3) into the piston (P6 or OM). (Skip this step for normally open valves.) 2. Install the actuator body (P4) so that the pilot port is positioned over port or desired location around valve. 3. Install the outer cap (P20) over the actuator body (P4). 4. Place the screw assembly on the preload fixture (T2) and secure with pin. Fully tighten the screw on the fixture. Lift the outer cap (P20) and make sure the two tabs protruding from the bottom of the actuator body (P4) enter the slots in the valve body (P). 5. Position the outer cap wrench (T) onto the outer cap (P20). Align the pins on the outer cap wrench (T) with the holes in the outer cap (P20). 6. Zero the torque wrench (T) and tighten the outer cap (P20) to 39 N m (29 ft lb) using the outer cap wrench (T) and the torque wrench (T4). 7. Remove the valve from the fixture. 8. After one hour, reinstall the valve into the fixture. Zero the torque wrench (T4) again and reapply 39 N m (29 ft lb) torque to the outer cap (P20) using the outer cap wrench (T) and the torque wrench (T4). 9. Remove the valve from the fixture. 20. For Omron kit only, install the Omron sensor mounting bracket (OM4) using 2X #8-32 mounting screws (OM5). Refer to Figure 4. TESTING The valve must be tested in the following ways: Actuator. Apply and remove 483 kpa (50 psig) pilot pressure to the 3.75 mm ( 8") FNPT port. Verify that the red indicator moves up and down. 2. Increase the pilot pressure to 552 kpa (80 psig) and repeat step. 3. In both cases, make sure there is no audible air leakage from the actuator. Inlet to Outlet Leakage 4. Connect 552 kpa (80 psig) pilot pressure to the 3.75 mm ( 8") FNPT pilot port and cycle the valve several times. 5. On normally closed valves, apply 552 kpa (80 psig) air to port with zero psig pilot pressure. No leakage should be seen at the outlet when the outlet port is submerged in water. 4 P/N 0-025696 Rev. D 09/7 Entegris, Inc.

6. On DS6 normally open valves, apply 345 kpa (50 psig) and on DS20 normally open valves apply 43 kpa (60 psig) pilot pressure to the pilot port and apply 552 kpa (80 psig) air to port with zero psig pilot pressure. No leakage should be seen at the outlet when the outlet port is submerged in water. External media leakage NOTE: Do not have pilot pressure applied when performing this test.. Apply 552 kpa (80 psig) air pressure to both ports. No leakage from the vent port should be observed when the vent port is submerged in water. 2. Testing is now complete. OM5 Mounting screws OM4 Mounting bracket Part Number DS6-SU-RKIT is for the following " normally open sampling valve designs: DS6-SU-* Part Number DS20-NO-RKIT is for the 4" normally open 2-way and normally open sampling valve designs: DS20-2U-* P2 Bellows P5 Stem/sleeve assembly P8 O-ring (brown) P9 O-ring P0 O-ring P Spring P4 O-ring P5 O-ring P2 Lubricant Repair Tool Kit Part Number DS-TOOL-KIT T Outer cap wrench T2 Preload fixture with small adaptor Figure 4. Omron sensor bracket mounting. ORDERING INFORMATION Repair Parts Kit Part Number DS6- NO-RKIT is for the following " normally open 2-way valve designs: DS6-2U-*, DS6-SU-* T3.75 mm (/6") wrench T4 Torque wrench T5 Adapter (large) T6 Spacer plate Customer supplied items S2 Isopropyl alcohol Entegris, Inc. P/N 0-025696 Rev. D 09/7 5

Repair Parts Kit Part Number DS6-NC- RKIT is for the following " normally closed 2-way and normally closed sampling valve designs: DS6-2C-*, DS6-SC-* Part Number DS6-SC-RKIT is for the following " normally closed sampling valve designs: DS6-SC-* Part Number DS20-NC-RKIT is for the 4" normally closed 2-way and normally closed sampling valve designs: DS20-2C-* P2 Bellows DS6 Omron Kit (Part Number DS6-OMRON-RKIT) OM Piston, DS6 Omron OM2 Lubricant OM3 O-ring OM4 Omron sensor bracket OM5 #8-32 screws 2 P5 Stem/sleeve assembly P8 O-ring (brown) P9 O-ring P0 O-ring P Spring P2 Spring P3 Spring P4 O-ring P5 O-ring P2 Lubricant 6 P/N 0-025696 Rev. D 09/7 Entegris, Inc.

Fixture setup table VALVE END CONNECTION T5 ADAPTOR (LARGE OR SMALL) T6 SPACER (YES OR NO) DS6 ½" Flaretek Small No DS6 " Flaretek Small No DS6 " Pillar Large Yes DS6 ¾" PureBond Small No DS6 " PureBond Small No DS6 ¾" PrimeLock Small No DS6 " PrimeLock Large Yes DS20 ¼" PrimeLock Large No DS20 " PureBond Large No Entegris, Inc. P/N 0-025696 Rev. D 09/7 7

FOR MORE INFORMATION Please call your Regional Customer Service Center today to learn what Entegris can do for you. Visit entegris.com and select the Contact Us link to find the customer service center nearest you. TERMS AND CONDITIONS OF SALE All purchases are subject to Entegris Terms and Conditions of Sale. To view and print this information, visit entegris.com and select the Terms & Conditions link in the footer. Corporate Headquarters 29 Concord Road Billerica, MA 082 USA Customer Service Tel + 952 556 48 Fax + 952 556 8022 Toll Free 800 394 4083 Entegris, the Entegris Rings Design, Pure Advantage, Integra, Flaretek, PureBond and PrimeLock are trademarks of Entegris, Inc.; Omron is a registered trademark of Omron Electronics LLC.; Pillar is a registered trademark of Nippon Pillar Packing Company, Ltd. 2006 207 Entegris, Inc. All rights reserved. Printed in the USA 3220-5770ENT-097 P/N 0-025696 Rev. D 09/7 www.entegris.com