Manual: GH2B-MCH Mini Simo Power Unit

Similar documents
GH2A-MC Series Mini Power Unit User Information Manual

Manual: Battery Powered Electro-hydraulic Rescue Tools

! WARNING! Read This Manual Before Operating Equipment

BT-1.5, BT-1.5-LP (NITRO) POWER UNIT Operations Manual

POWER UNIT Operations Manual

User and maintenance instructions. Fluid evacuator plus. Model MV7201. Date of issue November Form number Version 2

Owner s Information Manual

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

L0S ANGELES COUNTY FIRE DEPARTMENT BASIC SKILLS TRAINING PROGRAM HYDRAULIC RESCUE SYSTEM

Operating instructions Form no safety definitions

Hydraulic Immediate Need Power Pack

Instruction Manual. Maximum Operating Pressure 700 bar

Battery Powered Hydraulic Pump; Kit PN [ ]

Air / Hydraulic Pump

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

MANUAL: Foam Aspirators

Instruction Manual. Maximum Operating Pressure 510 bar

HYDRAULIC SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: HS2000 = 4.8 LBS. (2.17 Kg) HS3000 = 22 LBS. (9.98 Kg)

Hydraulic PTO Flow Device

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

High Lift Transmission Jack

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

3-Stage Under Axle Jack Weight: 69.5 kg (153 lbs.)

PORTABLE TRASH PUMPS MDP200

ABSOLUTE EQUIPMENT PTY LTD

ABSOLUTE EQUIPMENT PTY LTD

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

240SS Power Unit. Installation Manual. AMKUS, Inc. is an ISO 9001 registered company.

Installation Instructions

MANUAL FLUID EXTRACTOR

Rear Suspension Bushing Remover/Installer

SPECIFICATIONS SPECIFICATIONS

LS100L Battery-powered Punch Driver

Comprehensive Hydraulic Rescue System Inspection and Maintenance Agreement Revision 1 Effective 1/1/2010

Installation and Service Manual On-Highway Stabilization System

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

HYDRAULIC BODY REPAIR KIT

KLW4000D Multi-Port Power Pack

Operating, Servicing, and Safety Manual Model # Hydraulic Bender

VLW18TE, VLW18TI HYDRAULIC VERTICAL LIFTING WEDGES. Operator Instruction Manual INNOVATION IN ITS MOST FUNCTIONAL FORM

POWER PACK W/OIL COOLER P/N 32800

Walk-Behind Sprayer SL-80 & SL-80SS. Owner's Manual and Installation Instructions Original Instructions CAUTION

Air / Hydraulic Under Axle Jack

Installation and Operation Manual

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

2 Speed Hydraulic Hand Pump

WA 2719 ( 604 ) ( 604 ) , H.E.R.O.

MODEL G300 BRAKE BLEEDER

XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Single and Double Head Powered Screed. Screed King. User Manual. SCR-UM EN-04 (December 2018)

OWNER S MANUAL TOLL-FREE HELPLINE: (Monday - Friday / 8am - 4:30pm CST)

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Under Axle Jack Max. Capacity: 25 Tons

WGCT-A & WGCT-A/E TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Relius UV-Cure Adhesive Coating Dispenser Manual

Models 8100PP & 86110LP. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

60V RECHARGEABLE LITHIUM-ION BATTERY

Trouble Shooting Guide for V100 Positioner

Heavy Duty Electric Hydraulic Pumps PN and

#9040 FUEL TANK SWEEPER

Pistol Grip Battery-powered Pressing Tool

Hydraulic Gear Puller Instruction Manual

HOFFMANN POWER PRODUCTS PARTS LIST 2014

ULTIMATIC, MID-MATIC & HANDLINE

Explanation of Safety Signal Words

Tire Bead Seater. Explanation of Safety Signal Words. The safety signal word designates the degree or level of hazard seriousness.

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

Gas Engine Pumps Instruction Manual

X-Tractor Series. Cutters INSTRUCTION MANUAL

PSR-HP-3000 MANUAL HAND PUMP INTERNAL LIQUID CAPICITY MAXIMUM OUTPUT PRESSURE PsiG (BarG) GALLONS (LITERS) 3000 (207) 5 (19)

Operator s Safety and Service Manual

P239-1 Supply Pumper Instructions

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

MOTORVAC. BrakeVac-II. MODEL NUMBER Brake Fluid Service System. Operator Manual MotorVac

2311FA. Pressure Tester USER INSTRUCTION MANUAL BARFIELD M/N 2311FA Revision C April 12, 2011 BARFIELD, INC. Corporate Headquarters

SERIES OPERATION AND MAINTENANCE MANUAL

Pump Operating and Maintenance Manual - Models

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

OWNER S MANUAL. Model: UTL-60-12V ( ) (60 Gallon Lawn & Garden Utility Sprayer w/5-nozzle Boom)

Air Actuated Hydraulic Treadle Pump

I N S TA L L AT I O N G U I D E

Active Controlled Cooling System

User Manual Stealth s Power Tilt

POWER PINNER HAND WELDER 7200 OPERATOR S MANUAL

Premium Supply. Tilt Deck. Models PCK-TD PCK-PTD. Operator s Manual and Installation Instructions

MODEL B FLANGE SPREADER. Max. Pressure: 10,000 PSI (700 BAR) Unit Weight: 18 LBS. (8.16 Kg)

Refinery Supply Company, Inc.

Table of Contents WARRANTY

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

Instruction Sheet 1 1/8 HP TITAN PUMPS SAFETY FIRST

Transcription:

Understand manual before use. Operating AMKUS Rescue Systems without understanding the manual, receiving proper training, and using appropriate personal protective equipment is a misuse of AMKUS equipment. Obtain safety information at www.amkus.com/ This Safety Manual is intended to familiarize rescue workers and maintenance personnel with the safety messages of AMKUS Rescue Systems, including powered rescue tools (rams, cutters, spreaders, combination tools), power units (electric or gasoline driven), and powered rescue tool components (cable assemblies, hose assemblies, hose reels, etc.). The safety messages in this publication supersede safety information appearing in AMKUS publications prior to April 2016. This manual is intended for use with manuals published by manufacturers of prime movers (engines, electric motors, and pumps) used in AMKUS power units. This manual does NOT address operation or servicing of AMKUS Rescue Systems. Only competent rescue tool repair technicians are quali ed to repair AMKUS equipment. This manual should be available to all personnel involved with AMKUS equipment. Copyright Amkus Rescue Systems, Inc. 2016 LAA-001 April 15, 2016 Rev00 Manual: GH2B-MCH Mini Simo Power Unit Understand manual before use. Operating AMKUS Rescue Systems without understanding the manual, receiving proper training, and using appropriate personal protective equipment is a misuse of AMKUS equipment. This manual does not fully address safety. Additional safety information is published in AMKUS Safety Manual LAA-001. Obtain safety information at www.amkus.com/resources/information SAFETY MANUAL for AMKUS RESCUE SYSTEMS AMKUS RESCUE SYSTEMS www.amkus.com 4201 Montdale Drive, Valparaiso, IN 46383-4098 USA 800-592-6587 219-548-5000 Fax 219-476-1669 Certifi ed Compliant to NFPA 1936, 2015 Edition This manual is intended for use with manuals published by manufacturers of the prime movers (engine and pump) used in this power unit. AMKUS RESCUE SYSTEMS www.amkus.com 4201 Montdale Drive, Valparaiso, IN 46383-4098 USA 800-592-6587 219-548-5000 Fax 219-476-1669

Table Of Contents 1.0 MEANING OF SAFETY SIGNAL WORDS 2.0 SPECIFICATIONS 2.1 PART IDENTIFICATION 3.0 PROTECTIVE CLOTHING 4.0 TRAINING 5.0 SET-UP PROCEDURE 6.0 GETTING STARTED 7.0 OPERATING INSTRUCTIONS 7.1 GENERAL 7.2 SELECTOR VALVES 7.3 BOOST FUNCTION 8.0 TROUBLE SHOOTING 9.0 ROUTINE MAINTENANCE 9.1 ROUTINE MAINTENANCE FOR GASOLINE ENGINE 9.2 ROUTINE MAINTENANCE FOR HYDRAULIC PUMP 9.3 ROUTINE MAINTENANCE FOR HOSES 9.4 ROUTINE MAINTENANCE FOR COUPLINGS 9.5 MAINTENANCE RECORDS 10.0 INSPECTION, CLEANING, DECONTAMINATION, AND STORAGE 11.0 PARTS, SERVICE AND TECHNICAL INFORMATION PERSONAL RESPONSIBILITY CODE The member companies of FEMSA that provide emergency response equipment and services want responders to know and understand the following: 1. Firefi ghting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times. 2. It is your responsibility to read and understand any user s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use. 3. It is your responsibility to know that you have been properly trained in Firefi ghting and /or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use. 4. It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use. 5. It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer s instructions. 6. Failure to follow these guidelines may result in death, burns or other severe injury. FEMSA Fire and Emergency Manufacturers and Service Association P.O. Box 147, Lynnfi eld, MA 01940 www.femsa.org 2

1.0 MEANING OF SAFETY SIGNAL WORDS A safety related message is identifi ed by a safety alert symbol and a signal word to indicate the level of risk involved with a particular hazard. Per ANSI standard Z535.6-2011, the defi nitions of the four signal words are as follows: indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING CAUTION NOTICE WARNING indicates a hazardous situation which, if not avoided, could result in death or serious injury. CAUTION indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE is used to address practices not related to physical injury. 2.0 SPECIFICATIONS GH2B-MCH MINI Power Unit Specifications Length with Standard Couplings 18.0 in 457 mm Length with Mono Couplings 18.65 in 474 mm Width 12.25 in 311 mm Height 19.53 in 496 mm All weights include gas, engine oil, and hydraulic fluid Weight with Standard Couplings 59.55 lbs 27.0 kg Weight with Mono Couplings 59.65 lbs 27.1 kg Rated Output Pressure 10,500 psi 724 bar Rated Flow Of The Pump 2212 cc/min fi rst stage 574 cc/min second stage Fluid Type: AMKUS MV1 Mineral Base Hydraulic Fluid Safety Data Sheet (SDS) for AMKUS MV1 Hydraulic Fluid is available at AMKUS.com and CHEMTREC.com (For equipment stored and operated in environments below 32 deg. F (0 deg C) contact Amkus Rescue Systems for recommendation. Hydraulic Fluid Reservoir Capacity: 0.6 gals. US 2.27 liters Usable Hydraulic Fluid Capacity: 0.5 gals. US 1.89 liters Maximum Angle of Inclination: 20 degrees from horizontal Engine Engine Oil Fuel Engine Specifications Honda GX100 2.8 bhp (2.1 kw) *Refer to Honda GX 100 owner s manual. *Refer to Honda GX 100 owner s manual. 3

MODEL: GH2B-MCH SERIAL #: KXXXXXX DATE OF MFG: MM/YYYY SYSTEM PRESSURE: 10,500 psi (724 bar) 4201 Montdale Drive Valparaiso, IN 46383-4098 800-592-6587 219-548-4000 FLUID: AMKUS MV1 FLUID CAPACITY: 0.6 GAL (2.27L) USABLE FLUID CAPACITY: 0.5 GAL (1.89L) UNDERSTAND MANUAL BEFORE USE. OPERATING AMKUS RESCUE SYSTEMS WITHOUT UNDERSTANDING THE MANUAL, RECEIVING PROPER TRAINING, AND USING APPROPRIATE PERSONAL PROTECTION EQUIPMENT IS A MISUSE OF AMKUS EQUIPMENT. OBTAIN SAFETY INFORMATION AT WWW.AMKUS.COM KEL10-001 THIS POWER UNIT MEETS THE REQUIREMENTS OF NFPA 1936, STANDARD ON POWERED RESCUE TOOLS, 2015 EDITION. DO NOT REMOVE THIS LABEL. KEL10-003 2.1 PART IDENTIFICATION Selector Valve Knobs Fuel Fill Cap Engine Choke Control Hydraulic Fluid Fill Plug Fill/ Vent Cap Engine On/Off Switch Engine Pull Start Cord Sight Gauge Hydraulic Fluid Reservoir Throttle Hydraulic Fluid Drain Plug (bottom of reservoir) Oil Drain Plug Engine Oil Fill Cap Mono Coupling Safety Label Serial Number Standard Coupling 4

3.0 PROTECTIVE CLOTHING It is the responsibility of the user to insure that appropriate protective clothing and equipment are used to provide protection from those hazards to which personnel are exposed or could be exposed while working with this product. 4.0 TRAINING This product is designed to be used by emergency services personnel to facilitate the extrication of victims from entrapment. Its use should be limited to trained personnel only. All personnel using this equipment are assumed to have completed a course of instruction that is acknowledged as being educationally sound by the local authority having jurisdiction over such training. This document contains basic operating and maintenance instructions only. 5.0 SET-UP PROCEDURE AMKUS equipment is manufactured with superior craftsmanship and quality that is backed by the standard warranty which is published on the AMKUS website. Only use AMKUS tools with AMKUS equipment. Mixing AMKUS tools with another manufacturer s equipment may cause operational problems, equipment failure, or denial of warranty claims. NOTICE NOTICE Only use AMKUS mineral-base hydraulic fluid in AMKUS equipment. Using another manufacturer s hydraulic fluid in AMKUS equipment may cause operational problems, equipment failure, or denial of warranty claims. Normally, AMKUS equipment is prepared and serviced by your dealer prior to delivery. If, however, you have decided to place the equipment into service yourself, please review the following instructions carefully. 1. Remove equipment from the packing cartons and carefully inspect for damage. Damage that occurs during shipment should be reported immediately to the carrier. 2. The Honda engine that powers your unit is shipped without engine oil. Fill the engine crankcase with the proper oil as specified in the engine owner s manual. 3. Next, remove the hydraulic fluid reservoir fill plug/vent cap. Fill the hydraulic fluid reservoir with approximately 0.6 gallons U.S. (2.27 liters) of AMKUS mineral base hydraulic fluid. The fluid should reach a level that fills approximately ½ of the sight gauge window. Replace the fill plug/vent cap. 4. Following the instructions in the engine owner s manual, fill the engine fuel tank with the specified fuel. Avoid getting dirt or water in the fuel tank. Never use stale or contaminated gasoline or an oil/ gasoline mixture. 5. This power unit may be supplied either with hydraulic hoses attached (pump hoses) or with couplings (standard or mono) that require extension hoses. If your unit is equipped with pump hoses with standard couplings, connect the male and female couplings at the end of each hose set, creating a loop. If your unit is equipped with standard couplings, attach the extension hoses to the couplings on the power unit, and connect the male and female couplings at the opposite end of each hydraulic hose line set, creating a loop. If your unit is equipped with mono couplings, simply make sure that the hoses are connected to the power unit. 6. Prior to starting the engine, place the selector valves in their neutral positions. Follow the operating instructions in the engine owner s manual for starting the engine. Then operate the engine in the fast throttle position. 7. To purge air from the hydraulic hoses, charge each hose line by moving the knob on the corresponding selector valve to the flow position and allow the fluid to circulate through each hose line for at least one minute. Move each selector valve back to the neutral position. 8. Check the level of the hydraulic fluid in the sight gauge. Add more fluid if necessary. DO NOT OVERFILL. 9. If your unit is equipped with standard couplings, uncouple the male and female couplings on each hydraulic hose line set to open the loop that was created earlier. The power unit is now ready to use. 5

6.0 GETTING STARTED Connect the tool connection hoses to the hose lines from the AMKUS hydraulic power unit. 1. For power units equipped with standard couplings: The male and female couplings on the tool connection hoses should be connected to the corresponding male and female couplings on the hose lines leading from the power unit. To connect the couplings, twist the sleeve on the female coupling so that the notch in the sleeve lines up with the pin. Push the sleeve back so the pin fits into the notch. While holding the sleeve back, push the male coupling into the female coupling. Release the sleeve; it will spring forward into place. Twist the sleeve ¼ turn so that the pin no longer lines up with the notch. Pull on the couplings to check that they are securely connected. 2. For power units equipped with mono couplings: The male coupling on the tool connection hoses should be connected to the corresponding female coupling on the hose lines leading from the power unit. To connect the couplings, place the male coupling into the female coupling. Rotate clockwise until you feel the coupling latch. Pull on the couplings to check that they are securely connected. NOTICE 7.0 OPERATING INSTRUCTIONS 7.1 GENERAL The GH2B-MCH Mini Simo is a simultaneous operation power unit with a BOOST function. Two tools can be connected simultaneously and operated either independently or simultaneously. The BOOST function may be used during independent tool operation only. Prior to starting the engine, place the selector valves in their neutral positions. Start the engine by following the instructions in the engine owner s manual. Operate the engine at fast throttle for maximum rescue tool speed and performance. Use the idle position only when the rescue tools are not being operated. When you have finished operations, follow the instructions in the engine owner s manual to stop the engine. Please note that the minimum safe bend radius of the hoses is 4 inches (101.6 mm). 7.2 SELECTOR VALVES In most cases, the mono couplings can be connected and disconnected while the hose line(s) are under flow. It is usually not necessary to place the directional control(s) of the power unit in the neutral position before connecting and disconnecting. However, certain circumstances, such as back pressure in the return line(s) and/or cold temperatures, may make connecting and disconnecting under flow extremely difficult or impossible. If you are unable to connect or disconnect while the line(s) are under flow, place the directional control(s) of the power unit in the neutral position and then connect or disconnect. The GH2B-MCH Mini Simo is equipped with (2) two, (3) three position selector valves. When facing the front of the power unit with the selector valves in the neutral position, the handle of each valve will be pointing directly at the operator and in line with the hose it controls. In order to operate a tool that is connected to the left set of hoses, move the left selector valve handle to the flow position, or away from the center of the power unit. In order to operate a tool that is connected to the right set of hoses, move the right selector valve handle to the flow position, or away from the center of the power unit. The two tools can be operated independently or simultaneously. Neutral Position Left Flow - Right Flow To stop the flow of hydraulic fluid to each hose line, move the corresponding selector valve handle to the neutral position. The selector valve should be in the neutral position when you are finished with an operation or anytime you wish to stop the flow of hydraulic fluid. 6

7.3 BOOST FUNCTION The BOOST function increases the speed of an AMKUS tool under un-loaded and loaded conditions by combining flow from both pumps to one hose line. While AMKUS tools may be connected to both hose lines, only single tool operation is possible in BOOST mode. To operate a tool that is connected to the left set of hoses in BOOST mode, move the left selector valve handle to the flow position and move the right selector valve handle to the BOOST position, towards the center of the power unit.. This combines the flow from both pumps to the left set of hoses. To operate a tool that is connected to the right set of hoses in BOOST mode, move the right selector valve handle to the flow position and move the left selector valve handle to the BOOST position. Left Line Boost Right Line Boost This combines the flow from both pumps to the right set of hoses. To stop the flow of hydraulic fluid in BOOST mode, both selector valves must be moved to their neutral positions. 8.0 TROUBLE SHOOTING GUIDE Any problem not resolved by the following suggestions may require you to contact your local dealer or AMKUS Rescue Systems for further guidance. Problem Engine will not start or poor engine performance Tool lacks power or speed Fluid leaks at fittings or hoses Tools do not operate Solution Check Honda owner s manual Check hydraulic fluid level in power unit reservoir. Check tightness of hose fittings. Replace damaged hoses. Check to see that the power unit is running. Check to see that the line is charged. Check hydraulic fluid level in power unit reservoir. 7

9.0 ROUTINE MAINTENANCE 9.1 ROUTINE MAINTENANCE FOR GASOLINE ENGINE Follow the maintenance guidelines in the engine owner s manual. 9.2 ROUTINE MAINTENANCE FOR HYDRAULIC PUMP Normally, you will have a maintenance agreement for your system with your local dealer. However, if you have decided to service the equipment yourself, please review the following instructions carefully. Change hydraulic fl uid after each 20 hours of tool operation (approximately every 2 years). If you suspect your hydraulic fl uid has been contaminated in any way, contact your local dealer or AMKUS Rescue Systems. To change the hydraulic fluid, remove the hydraulic fluid reservoir fill plug/vent cap. Place the unit over a drain pan; unscrew and remove the drain plug. Be careful not to lose it! Allow the hydraulic fluid to drain completely. Clean and replace the drain plug. Fill the hydraulic fluid reservoir with new AMKUS mineral base hydraulic fluid. Replace the fill plug/vent cap. The next step is to purge air from the hydraulic hoses. Please see Set-Up Procedures points 5-9. Check the pressure output of the power unit at each hose line by connecting a pressure gauge to the pressure line. Move the selector valve to charge the line to which the gauge is connected. The rated hydraulic pressure at maximum output is 10,500 psi +- 500 psi (724 bar+-34 bar). Verify performance by periodic testing using a pressure gage. If performance falls outside of this range, contact your local dealer or AMKUS Rescue Systems. DO NOT ATTEMPT TO ADJUST THE INTERNAL PRESSURE RELIEF SETTING! Pressure relief valves are NOT user serviceable. User adjustment is a misuse of this equipment. 9.3 ROUTINE MAINTENANCE FOR HOSES After each use, hoses should be wiped clean with a light cleaner such as Simple Green. Inspect hoses for damage to the rubber outer cover. Damage which exposes the wire braided reinforcement subjects the wire to corrosion and may weaken the hose. 9.4 ROUTINE MAINTENANCE FOR COUPLINGS Use care when making hydraulic connections by avoiding dirt, sand, and water puddles at the emergency scene. Even with care, residual oils on the moving parts will gradually accumulate dirt and grit making connections difficult. Couplings and dust caps can be periodically cleaned using an automotive type aerosol solvent de-greaser. Avoid water-based cleaning products. Apply a light spray lube (automotive, lock, or gun type) to keep the collars moving easily. Avoid covering a clean coupling with a dirty dust cap. 9.5 MAINTENANCE RECORDS It is the responsibility of the user to keep maintenance records for each component of the rescue system. Maintenance shall be performed by qualified service technicians in accordance with the recommendations as outlined in this manual. 10.0 INSPECTION, CLEANING, DECONTAMINATION, AND STORAGE 1. Always store the power unit in a clean dry space. 2. Never store a power unit under pressure. 3. Store the power unit upright. BEFORE BEING PLACED BACK IN SERVICE, power units must be inspected to this checklist; 1. Check to see that all markings are legible. Contact your local dealer or AMKUS Rescue Systems for replacement labels. 2. Wipe tool, hoses, fittings and couplings clean (see routine maintenance for hoses and couplings). 3. Inspect the power unit, hoses, fittings and couplings after each use for damage, leakage and excessive wear. 4. If the power unit becomes contaminated, determine the nature of the contamination. IE: biological, chemical, radioactive. The authority having jurisdiction may follow internal decontamination guidelines or request technical advice from AMKUS. 5. Check engine oil per the manufacturer recommendations after each use. 6. Check the hydraulic fluid levels after each use. Replenish as necessary with AMKUS MV1 mineral based hydraulic fluid. Any power unit failing any part of the checklist is unsafe for use and must have the problem WARNING corrected before use or being placed back into service. Operating a power unit that has failed the checklist is a misuse of this equipment. 11.0 PARTS, SERVICE AND TECHNICAL INFORMATION Parts, service and technical information may be obtained from your local AMKUS dealer, or by contacting AMKUS Rescue Systems. AMKUS RESCUE SYSTEMS www.amkus.com 4201 Montdale Drive, Valparaiso, IN 46383-4098 USA 800-592-6587 219-548-5000 Fax 219-476-1669