Ph.no / Kanchan Eneterprises. id- DOL Starter Type 3TW42 00 (open execution)

Similar documents
Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

Bimetal Overload Relays 3UA and 3UC

Automatic Star Delta Starters IEC : 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

LV Switchgear Maximum Retail Price w.e.f 15 th December, Answers for industry.

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

CI-TI Contactors and motor starters Types CI 61 - CI 98

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

SECTION PANELBOARDS

3SB5 Operating Instruction Manual

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

ACS motor protection circuit breakers KT 7 Introduction

BETA Switching Switches and Light Indicators

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

Direct On Line (DOL) Motor Starter. Direct Online Motor Starter

3RT14 Contactors with 3 Main Contacts

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

Magnetic Overload Relays

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

HD 7700 Setup & Operator Manual

Installation Manual for DC Injection Brake Units

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

OLYMPIAN MODEL 740 Operation and Service Manual

Overload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview

A. Submit manufacturer's literature and technical data before starting work.

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

INSTALLATION AND OPERATING INSTRUCTIONS

Q-04: Replace Brake Shoes/Adjust Brakes

C E R T I F I C A T E O F C O M P L I A N C E

ADS7 AC Contactor Starters

INSTALLATION AND OPERATING INSTRUCTIONS

Design Standard. Purpose: Design Standard:

3VU13, 3VU16 Circuit-Breakers

FAN-STOP INSTRUCTION MANUAL

Contactor Relays 3TH30

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Starting of Induction Motors

Enclosed Starters. Contents. Motor nominal powers and current... 20/2. Panorama... 20/3. Starting of three-phase asynchronous motors...

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

INSTALLATION AND OPERATING INSTRUCTIONS

Youngstown Power Limit Switches

HQ Series ¼ Turn Electric Actuator

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

SPECIFICATIONS ULTIMAX SUB-SURFACE DIRECTIONAL AERATION SYSTEM

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

SIGNAL WORDS QUALIFIED PERSON

Motor Protection Circuit Breaker

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

SERVICE AND REPAIR PARTS NEMA SIZE 5, SINGLE POLE, NORMALLY OPEN, P/N SERIES NEMA SIZE 5A, SINGLE POLE, NORMALLY OPEN, P/N SERIES

Electrical operating instructions

(Miniature Circuit Breaker)

Product Selection 3-Pole Contactors

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Techcon Systems TS6500 CIM Automatic Techkit Mixer

CI-TI Contactors and Motor Starters Type CI 6-50

1/4HP - 7.5HP 120/240/277 VOLTS 50/60HZ

INSTALLATION INSTRUCTIONS: Viewline 85 mm

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

ICG Switchgear Price List 2009

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

A200 NEMA Contactors and Starters A200

Owner's/Installation Manual

Motor-drive mechanism, type BUL. Technical guide

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Submersible Tank Pump

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

Manual Motor Starters. Meta-MEC

Operation Care Service

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

12 Series Linear Electric Actuator Installation, Operation & Maintenance Manual

Overload Relay Heater Tables

Designed for ease of integration with automation systems

THE BEST ELECTRICAL CONTROLS BUSINESS ON THE PLANET! Unmatched Service Superior Product Quality Advantage Pricing

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

CABINET REEL OPERATING INSTRUCTIONS

POND PUMP Model Nos:SPP3 & SPP6 0200

Mizer Single Pump and Starter Box

Ktec Contactors and thermal overloads

SECTION 9 CRANKING SYSTEM CONTENTS

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

A1P OPERATING MANUAL

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

MAGNETIC MOTOR STARTERS

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Transcription:

Siemens Ltd. SGR-01-103-035 'Product development is a continuous process. Consequently the data indicated in this Booklet is subject to change without prior notice. For latest issue contact our Sales Office.' 4I-0089-0115980 001 s Installation, Operation & Maintenance Instructions DOL Starter Type 3TW42 00 (open execution)

For dependable service, it is of utmost importance that instructions given below are followed for selection, inspection, installation, commissioning, operation and maintenance. Selection: Refer Table A,B,C and D for recommended selection of starters. Table A: kw/hp rating,thermal overload relay range & fuse rating. Table B: Coil voltage Table C: Relay range codes. Table D: Max full load currents for different types of motors. Inspection: Ensure that the relay range and coil voltage are as per your requirement. Inspect interior for breakage. If you find a serious defect, do not use the product but have it checked by an authorized Siemens dealer or an electrician. Installation: Mount the starter in an enclosure and the enclosure on a vertical rigid surface free from vibration. The drilling template is enclosed for convenience. Refer Fig.1 for mounting dimensions and Fig.2 for permissible displacement from vertical plane. The enclosure should not allow ingress of dust,dirt or contamination. Connect the incoming and outgoing cables as follows : Select the correct size of cables from the table-1. Connect line & motor leads exactly as per wiring diagram. Terminal screws: M4 Tightening Torque: 80-110 N-cm The Starter is now ready for commissioning. * Mounting Dimensions 64 x 108 (Use M4 screws) Fig. 1 : Dimensional Details Maximum 15 O permissible Fig. 2 : Maximum permissible displacement from vertical plane 2 3

Commissioning: Caution: During commissioning or maintenance always ensure that the main supply is disconnected by switching off the main switch. If the relay trips even when set at the rated motor current the suitability of the starter/relay for the particular application should be checked with the nearest Siemens office. Setting of Auto/hand reset mode (Ref.Fig.3) In the delivered condition, the relay is set in H=Hand (manual) resetting mode. To change from H=Hand (manual) H - Hand Reset A - Auto Reset Fig. 3 : Relay Front View Blue Reset Knob resetting to A=Automatic (self) mode, press and turn the Blue button on the relay counter clockwise from H to A. Procedure for setting the overlaod relay : For closer protection, set the overload relay to actual current as measured by an ammeter. In the absence of an ammeter, follow the procedure given below:- Set the relay to rated current mentioned on the motor name plate. Press the ON button of the starter or the green button of the contactor to start the motor and wait till it reaches to normal speed and let it run for approximately 30 minutes on full load.then gradually reduce the relay setting till it trips.set the relay at a slightly higher value than this setting. Allow the reset time of approximately 4 min before pressing the blue button on the relay to reset it (in case the relay is set in HR mode) or the relay resets on its own after approx 4 minutes after it trips (in case the relay is set in SR mode). Restart the motor. If the relay does not trip, consider it to be properly set. If it trips, set it at a little higher value than before and recheck. Overload relay characteristics shown in fig. 4 can be used to estimate the average tripping time at different multiples of the set current. Operating Characteristics The given characteristics (Fig.4) are average values of all the ranges and sizes of bimetal relays and are mainly intended to indicate the inverse time current characteristics of the same. The tripping times shown are for relays starting from the cold state. At operating temperatures (heated at rated current) these are reduced to about 25% of the value obtained from the characteristics. Operation: For starting the motor, install ON push button (Green)- contact element (NO) combination on enclosure cover and wire-up as shown in the wiring diagram. Press Green push button to start the motor. For stopping the motor, install OFF push button (Red) - contact element (NC) combination on enclosure cover and wire-up as shown in the wiring diagram. Press Red push button to stop the motor. For reseting the relay from panel door,use accessoryresseting cord with holder or reset funnel. (refer spares/ accessories list for ordering). In case you want the starter to be in Self-Reset mode, the blue knob on the relay is to be pressed and rotated in the anti-clockwise direction, so that it comes in position A and its edge is flush with the surface. In this mode even if the relay trips on overload,it will be automatically reset in a maximum of 4 minutes. The motor can be restarted only after the relay is reset. In hand reset mode for resetting, press button marked R if the relay has tripped due to overload (use resetting cord with holder). In this case the motor can be restarted only after you reset the relay. Allow a minimum time of 4 minutes, before resetting it. 4 5

Fig. 4 : Operating characteristics of 3UW50 relays Minutes 6 7

Note : It is recommended that relay be set in the HR (hand reset) mode in case of applications involving maintained ON command e.g.use of autoswitch or float switch, etc. in order to avoid damage to the starter/motor. Maintenance: Switch off the starter and disconnect the main supply by switching off the main switch before doing any maintenance. Keep the interior dust free. Re-tighten the terminal screws from time to time. No maintenance is needed for overload relay. Please do not open the relay. Blackening of silver/alloyed contacts does not affect operational life. If necessary, clean the contacts of contactor with CRC 2-26. Remove the globules with a scrapper or a screw-driver with minimal force. Under no circumstances should the contacts be filed or dressed as it will reduce the electrical life drastically. If the contactor hums, clean the magnet pole with a soft cloth/crc2-26/chamois leather/ size 00 emry paper if found rusty. Replace contacts of the contactor if they are severely pitted or when only 40% of the original contact tip remains. For details of contactor maintenance refer to our Guide to Contactor Installation & Maintenance. Replacement of Arc Chamber: Remove the existing arc chamber as shown in (Fig.5) Replace it by a new arc chamber (refer the spares list for item no.) Ensure that the arc chamber is flush with the contactor body. Replacement of overload relay Removal i. Disconnect the wires connected to the relay terminals. ii. Loosen the outgoing terminal screws of the contactor. iii.lift the overload relay vertically upwards to disengage its hook (Fig.6) from the slot of the bracket mounted on the base plate. iv.pull the overload relay away from contactor and in outward direction. Refixing i. Select the overload relay of proper range by referring to table A and spares list. ii. Set the relay either in Hand reset or Auto reset mode as per your requirement. Fig. 5 : Removal of arc chamber iii.connect the relay terminals (L1 L2 L3) to the contactor terminals(t1 T2 T3). iv.ensure that the relay hook (Fig.6-1) is engaged in the slot of the relay mounting bracket (Fig.6-2) and slide the relay inwards till the cover is flush with contactor ribs.(fig.6-3) v. Tighten the contactor terminal screws. vi.reconnect the disconnected relay wires and check the correctness of the starter wiring. Fig. 6 : Contactor-Birelay Connection 1. Hook for relay engagement 2. Relay mounting bracket 3. Contactor ribs flush with relay edge. 8 9 3 1 2

Replacement of the Main Contacts: (Fig.7 & 8) Remove the arc chamber. (Fig.5) Remove and inspect the contacts. When contact tips get eroded and base material is seen, refer spares list to replace contacts. Put back the Arc Chamber. 5 6 7 10 1 2 3 4 Fig. 7 : Fixed/moving, main/auxiliary contacts inspection. 1, 2, 3 : Main contacts 4 : Auxiliary contacts 5, 7 : Fixed contacts 6 : Moving contacts Replacement of Coil: (Fig.9) Disconnect all the wires connected to the contactor. Disconnect the relay from the contactor and remove the contactor from the base plate by loosening the mounting screws. Turn the contactor upside down,unscrew the bottom cover and remove it. Ensure that the new coil is of proper voltage. (Table B). Ensure all springs are placed at proper location. Put back the bottom cover. Nose plier Fig. 8(A) : Replacement of moving contacts Fig. 8(B) Replacement of fixed contacts 2 10 5 4 Fig. 9 Replacement of Coil 1 : Bottom Cover 2 : Liner for shock absorption 3 : Fixed Magnet 4 : Bracket Assembly 5 : Return Spring Ensure that the liner (Fig.9-2) is properly put. Fix the contactor on the base plate, connect the relay and reconnect the disconnected wires and ensure that the connections are proper as per circuit diagram. 9 8 6 : Return Spring 7 : Coil 8 : Contactor housing along with moving magnet 9 : Aux. Contact 10 : Coil terminals 7 6 3 1 11

Table A : Selection Table for RAJA Starter in open execution 1) RAJA DOL Starter for Monobloc pumps 5 3.7 3TW4200-0A*74 6.3-10 25 21 SWG 1.5 - - 3TW4200-0A*75 8-12.5 25 19 SWG 1.5 7.5 5.5 3TW4200-0A*77 10-16 32 18 SWG 2.5 10 7.5 3TW4200-0A*78 12.5-20 32 18 SWG 4 2) RAJA DOL Starter for Submersible Pumps Rating for 4P, Back-up Fuse Recomm- Relay 415V, 3Ph, Rating ended Type Range 50hz Motor HRC fuse Rewir- Cu cable 3UW50 HP # kw Rating (A) able size (mm 2 ) Rating for 4P, Back-up Fuse Recomm- Relay 415V, 3Ph, Rating ended Type Range 50hz Motor HRC fuse Rewir- Cu cable 3UW50 HP # kw Rating (A) able size (mm 2 ) 5 3.7 3TW 4200-0A*75 8-12.5 25 19 SWG 1.5 7.5 5.5 3TW 4200-0A*77 10-16 32 18 SWG 2.5 * Enter code for coil voltage (Table B) # While selecting pl. ensure that rated AC3 current rating ( 20 A ) of the starter is not exceeded. 12 Spares List Sr. No. Description Order No. 1 Contactor 3TW0 290-0A * 51 (Refer Table B for*) 2 Birelay 3UW50 02 - ** (Refer Table C for **) 3 Main contact kit (Each set comprises of 3TX0 200-0YA0 6 Fixed Contacts and 3 Moving Contacts) 4 Contact Kit - Single Pole (Each set 3TX0 200-0YA1 comprises of 2 fixed contacts and 1 moving contact.) 5 Coil 3TX 203-0Y*6 (Refer Table B for *) 6 Cover (Arc chamber) 3TX0 202-0YA0 7 Aux. fixed contact 3TX0 200-1YB0 8 Aux. moving contact 3TX0 200-1YC0 Table B Voltage Code 200-400 V B 130-230V P 415 V W 220 V M Table C Relay Range Code for 6.3-10 1J 8-12.5 1K 10-16 2A 12.5-20 2B 13

Accessories List 14 Sr. No. Description Order No. 1. Complete Push-button Unit 3SB1202-0AE01 Green normal actuator + 1NO contact block 2. Complete Push-button Unit 3SB1203-0AC01 Red normal actuator + 1NC contact block 3. Reset Cord with holder 400 mm length 3UX1015 600 mm length 3UX1016 4. Resetting plunger & funnel arrangement Plunger Funnel 3UX1011 3UX1013 5. Inscription Plates START 2SY2 507-2A STOP 2SY2 508-2B Wiring Diagrams: Raja Direct-On-Line Starter (For Single Phase Motors) 3TW42 00-0A * Connect 3/L2 to 2/T1 by cable of suitable size. (max 4 mm 2 ) * Diagram shows connections made for contactor coils rated at 130-230V, 50Hz and 220V, 50Hz. S01 - Remote OFF Push Button S11 - Remote ON Push Button S4 - Reset knob (Blue) Q1 - Contactor K1 - Bimetal Relay with SPP feature R - Remote Reset Push Button 15

16 RAJA Direct-On-Line Starter (for Three Phase Motors) 3TW42 00-0A S01 - Remote OFF Push Button S11 - Remote ON Push Button S4 - Reset Knob (Blue) Q1 - Contactor K1 - Bimetal Relay R - Remote Reset Push Button * Diagram shows connections made for contactor coils rated 200V-400V (wide-band), 415V(320-455V), 50Hz. * For coils rated 130-230V, 50Hz and 220V, 50Hz disconnect the wire between L3-S01 and connect the neutral of the supply system to the terminal of S01. Table D Max. Full Load Current (Amp) Motor 3 Ph, 415V, 4P 3 Ph, 415V, 2P 1 Ph, 240V Rating Squirrel Cage Submersible CSIR or Split- IS 8789 : 1996 Motor Phase Table 4 IS 9283 : 1995 IS 996 : 1979 HP kw Table 2 Table 9 0.33 0.25 3.8 0.5 0.37 1.4 6 0.75 0.55 1.7 7 1 0.75 2.2 7 1.5 1.1 2.9 3.25 13 2 1.5 3.8 4.5 18 3 2.2 5.1 6.5 5 3.7 8.1 10 7.5 5.5 11.4 14.5 10 7.5 15.4 19.5 12.5 9.3 19.5 25 15 11 23 29 20 15 32 39 25 18.5 38.5 Note : The above table gives the max. full load current for various motors commonly used. It is recommended that the above table be referred to in conjunction with motor name plate data, before selecting the starter with appropriate relay range. 17

Notes Notes 18 19

Reply Card Please Affix Stamp To, Siemens Ltd. (Standard Products Division) Thane Belapur Marg, Kalwe, Thane - 400601. # Electrician registration form I have installed starter Type No : / at village district State Motor HP Type of Motor Brand Please register my name for the future updates about your Motor Starter range My Name : Shop s Name : Address : Pin STD Code : Tel : Fax : Date of Purchase : Date of Installation : Name & address of Siemens Authorised dealer or Siemens Starter House #Name & address of Sub-dealer

16 Spares List Sr. No. Description Order No. 1 Contactor 3TW0 290-0A * 51 (Refer Table B for*) 2 Birelay 3UW50 02 - ** (Refer Table C for **) 3 Main contact kit (Each set comprises of 3TX0 200-0YA0 6 Fixed Contacts and 3 Moving Contacts) 4 Contact Kit - Single Pole 3TX0 200-0YA1 5 Coil 3TX 203-0Y*6 (Refer Table B for *) 6 Cover (Arc chamber) 3TX0 202-0YA0 7 Aux. fixed contact 3TX0 200-1YB0 8 Aux. moving contact 3TX0 200-1YC0 9 ON SPA 3TX0 204-1YA0 10 OFF SPA 3TX0 204-1YB0 11 'Reset' SPA 3TX0 204-1YR0 12 Contact Holder 3TX0 200-0YD0 13 'ON/OFF' contact Element 3SX1 551-1YA 14 Switch for HSD starter 3LA0 204-4YB Table C Relay Range Code for 0.63-1 0J 1-1.6 1A 1.6-2.5 1C 2-3.2 1D 3.2-5 1F 4-6.3 1G 6.3-10 1J 8-12.5 1K 10-16 2A 12.5-20 2B Table B Voltage Code 200-400 V B 130-230V P 415 V W 220 V M Fig. 11(A) Replacement of moving contacts 2 10 5 4 Fig. 12 Replacement of Coil 1 : Bottom Cover 2 : Liner for shock absorption 3 : Fixed Magnet 4 : Bracket Assembly 5 : Return Spring Nose plier Fig. 11(B) Replacement of fixed contacts 9 8 6 : Return Spring 7 : Coil 8 : Contactor housing along with moving magnet 9 : Aux. Contact 10 : Coil terminals 9 7 6 3 1

18 RAJA Direct-On-Line Starter (for Single Phase connection) Wiring Diagram for Single-Phase Motors Note : Connect 3/L2 to 2/T1 by cable of suitable size. (max 4 mm 2 ) 3TW42 90-1A Refixing i. Select the overload relay of proper range by referring to table A and Spares list. Ensure it's blue knob in Auto reset position marked with A. ii. iii. iv. Connect the relay terminals (L1 L2 L3) to the contactor terminals (T1 T2 T3). Ensure that the relay hook (fig. 9-1) is engaged in the slot of the bracket (fig. 9-2) welded to the housing and slide the relay inwards till the cover is flush with contactor ribs. (fig. 9.3) Tighten the contactor terminal screws. v. Reconnect the disconnected relay wires and check the correctness of the starter wiring as shown on the inside of the front cover. l Replacement of main contacts: (fig. 11) Remove the Arc Chamber. 3 1 2 Fig. 9 Contactor - Birelay Connection 1. Hook for relay engagement 2. Relay mounting bracket 3. Contactor ribs flush with relay edge. 7

20 Dimensional Drawings: RAJA Direct-On-Line Starter * Mounting diamensions 154 x 70 Fig. 5 Setting the relay dial 4 3 5 6 Fig. 6 Starter in closed position 1. ON push button (Green) 2. OFF Push button (Red) 3. Cover fixing screws 4. Housing 5. Cover 6. Name Plate 1 2 3 Operation l ON/OFF Operation Switch ON the starter by pressing the green push button (marked I ) (Fig. 6-1) on the starter cover. Switch OFF the starter by pressing the red push button (marked O ) (fig. 6-2) on the starter cover. l Reset Operation If the overload relay trips, it resets automatically. (*Allow a reset time of approx. 4 min.) l It is recommended that the DOL Starter (Self reset type) is not to be used in applications involving maintained 'ON' command. In such applications hand reset type of starter is recommended. iv. Pull the overload relay away from contactor and in outward direction. 5

Table D 22 Motor Rating HP kw Max. Full Load Current (Amp) 3 Ph, 415V, 4P 3 Ph, 415V, 2P 1 Ph, 240V Squirrel Cage Submersible Motor CSIR or Split-Phase IS 8789 : 1996 Table 4 IS 9283 : 1995 Table 2 IS 996 : 1979 Table 9 0.33 0.25 3.8 0.5 0.37 1.4 6 0.75 0.55 1.7 7 1 0.75 2.2 7 1.5 1.1 2.9 3.25 13 2 1.5 3.8 4.5 18 3 2.2 5.1 6.5 5 3.7 8.1 10 7.5 5.5 11.4 14.5 10 7.5 15.4 19.5 12.5 9.3 19.5 25 15 11 23 29 20 15 32 39 25 18.5 38.5 Note : The above table gives the max. full load current for various motors commonly used. It is recommended that the above table be referred to in conjunction with motor name plate data, before selecting the starter with appropriate relay range. Incoming Cable gland Fig. 3 A.B. Connection of outgoing and incoming cable, using cable gland. outgoing cable connections. (fig. 2) l Connect incoming and outgoing cables as follows : (fig. 3) Select correct size of cable from Table-A. (max. cable size allowed is 4 mm 2 ) Remove approx. 10 mm of insulation. Pass the cable through proper cable gland to avoid ingress of material. Connect the cables and tighten the screws firmly. (Terminal Screws : M4, Stripped Length : 10 mm) l Set the overload relay scale (fig. 4A-4) using proper screw driver as per the procedure given below : (fig. 5) Set the relay to rated current mentioned on motor name plate. Press green button of the contactor (fig. 4B-7) to start the motor and wait till it reaches to normal speed. Reduce the relay setting till it trips. 3

Reply Card Please Affix Stamp To, Siemens Ltd. (Standard Products Division) Thane Belapur Marg, Kalwe, Thane - 400601. Electrician registration form I have installed starter Type No : 3TW4290-1A / 3LW4290-0A at village district State Motor HP Type of Motor Brand Please register my name for the future updates about your Motor Starter range My Name : Shop s Name : Address : Pin STD Code : Tel : Fax : Date of Purchase : Date of Installation : Name & address of Siemens Authorised dealer or Siemens Starter House Name & address of Sub-dealer

Auto / Hand Reset RAJA Direct-On-Line Starter