Manufacturing and Comparative Analysis of Threaded Tube Heat Exchanger with Straight Tube Heat Exchanger

Similar documents
Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

International Journal of Advance Engineering and Research Development

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

Performance Evaluation Of A Helical Baffle Heat Exchanger

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

Design and experimental analysis of pipe in pipe heat exchanger

International Journal of Advance Engineering and Research Development

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

CFD ANALYSIS ON LOUVERED FIN

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Thermal Stress Analysis of Diesel Engine Piston

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Heat Exchangers (Chapter 5)

Numerical Simulation of the Thermoelectric Model on Vehicle Turbocharged Diesel Engine Intercooler

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Heat transfer enhancement of a single row of tube

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

A comparative analysis to enhance the effectiveness of EGR coolers used in diesel engine

Back pressure analysis of an engine muffler using cfd and experimental validation

Computational Investigation of Normal and Hybrid Cooling Fins of Internal Combustion Engine

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Design of Shell and Tube Type Heat Exchanger using CFD Tools

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

CFD Integrated Optimum Design and Prototyping of Shell and Tube Heat Exchanger

Investigation of Comparison of Three Different Tube Bundles of Heat Exchanger

Cross Flow Heat Exchanger H352

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

CFD analysis of triple concentric tube heat exchanger

CFD Flow Analysis and Optimization of Exhaust Muffler

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

Numerical Investigation of the Effect of Excess Air and Thermal Power Variation in a Liquid Fuelled Boiler

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Cross Flow Heat Exchanger H352

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

A Study on the Optimum Shape of Automobile Air Cleaner Diffuser

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

Chapter 7: Thermal Study of Transmission Gearbox

CONSTRUCTION AND ANALYSIS OF TUBE IN TUBE TYPE HEAT EXCHANGER

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture

CFD ANALYSIS OF FLUID FLOW AND HEAT TRANSFER IN A SINGLE TUBE-FIN ARRANGEMENT OF AN AUTOMOTIVE RADIATOR

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Thermal Analysis of Multi Tube Pass Shell and Tube Heat Exchanger

DESIGN OPTIMIZATION OF SHELL AND TUBE HEAT EXCHANGER FOR OIL COOLER BY COMSOL MULTIPHYSIS

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

CFD Analysis of Heat Transfer Prediction for Corrugated Shell & Tube Heat Exchanger

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

Static And Modal Analysis of Tractor Power Take Off (PTO) Gearbox Housing

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

Quality Improvement in Design Process of Shell & Tube Type Heat Exchanger by Computer Integrated 3D Modeling

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

INTERCOOLER FOR EXTREMELY LOW TEMPERATURES OF CHARGING

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

Automation of Optimal Design of Air Preheater s Corrugated Heating Elements using CFD

ADVANCES in NATURAL and APPLIED SCIENCES

Investigation of Radiators Size, Orientation of Sub Cooled Section and Fan Position on Twin Fan Cooling Packby 1D Simulation

Exhaust Waste Heat Recovery of I. C. Engine by Thermoelectric Generator

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

An Overview of Shell & Tube Type Heat Exchanger Design by Kern s Method

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Transcription:

Research Inventy: International Journal of Engineering And Science Vol.4, Issue 7 (July 2014), PP 77-85 Issn (e): 2278-4721, Issn (p):2319-6483, www.researchinventy.com Manufacturing and Comparative Analysis of Threaded Tube Heat Exchanger with Straight Tube Heat Exchanger Prof.N.B.Totala 1, Prof.V.P.Desai 2, Pratik Gawade 3, Nikhil Kakade 4,Anant Paralkar 5, ArpitBanerjee 6, Shreenath Agarwal 7 1,2 (Assistant Professor, Department of Mechanical Engineering, MIT Academy of Engineering,Alandi (D), Pune, Maharashtra, 412105) 3,4,5,6 (Department of Mechanical Engineering, MIT Academy of Engineering, Alandi(D), Pune, Maharashtra, 412105) 7 (Assistant Manager, Production G Series, Greaves Cotton Ltd, Diesel Engine Unit, Akurdi.Pune.) ABSTRACT: To intensify the heat transfer from the heat exchanger surface to fluid, it is possible to increase convection coefficient, widen temperature difference between surface and fluid or increase the surface area across which convection occurs. Extended surfaces, in the form of longitudinal or radial fins are common in applications where the need to enhance the heat transfer between a surface and an adjacent fluid exists. Fins are commonly used in extended surface exchangers. To minimize the size of heat exchangers, fins are used to increase the surface area and the heat transfer rate between the heat exchanger surface and the surroundings. Both the conduction through the fin cross section and the convection over the fin surface area take place in and around the fin, the temperature value is limited by the type of material and production technique. Due to all above, finned tube heat exchangers are used in different thermal systems for applications where heat energy is exchanged between different media. Applications range from very large to the small scale (tubes in heat exchangers, the temperature control of electronic components).the subject, which is investigated in this paper, is concentrated on increasing heat transfer rate by provided extended surfaces like threads. By providing threads, heat transfer area increases and it leads to better heat transfer due to turbulence. KEYWORDS: Heat transfer co-efficient, Nusselt number, Reynolds number, Thermal conductivity, I. INTRODUCTION The performance of a conventional heat exchanger, which is an essential unit in heat extraction and recovery systems, can be substantially improved by a number of augmentation techniques. Common thermalhydraulic goals are to reduce the size of heat exchanger required for specified heat duty, to upgrade the capacity of an existing heat exchanger, to reduce the approach temperature difference for the process streams, or to reduce the pumping power. A preferred approach to the problem of increasing heat exchanger effectiveness, while maintaining minimum heat exchanger size and operational cost, is to increase the heat transfer exchange rate.the addition of fins reduces the thermal resistance on that side and thereby increases the net heat transfer from/to the surface for thesame temperature difference. The heat transfer coefficient can also be higher for fins.to develop the correlations for forced convection for the inner pipe in tube in tube heat exchanger having threaded shape using experimental and numerical techniques. This geometry is expected to augment heat transfer for vortex shedding and turbulence because of internal curvatures and enhanced area available for heat transfer.in order to do so, the experiments employ tube in tube heat exchanger with two configurations of the inner tube namely straight smooth tube and threaded tube. The experimentation will be conducted for the Reynolds number in turbulent region ranging from 6000 to 25,000. A.E. Bergles, [1] showed that heat energy is conserved by heat transfer enhancement.c.a. Balaras, [2] reviewed of augmentation techniques for heat transfer surfaces in single-phase heat exchangers.wolverine INC [3] An engineering data book was referred to have a insight for enhanced heat exchangers. Kim[4]Studied the characteristics of flat plate finned-tube heat exchangers with large fin pitch. In this study, 22 heat exchangers were tested with a variation of fin pitch, number of tube row, and tube alignment. The air-side heat transfer coefficient decreased with a reduction of the fin pitch and an increase of the number of tube row. The reduction in the heat transfer coefficient of the four-row heat exchanger coil was approximately 10% as the fin pitch decreased from 15.0 to 7.5 mm over the Reynolds number range of 500 900 that was calculated based on the tube diameter. For all fin pitches, the heat transfer coefficient decreased as the number of tube row increased from 1 to 4. The staggered tube alignment improved heat transfer performance more than 10% compared to the 77

inline tube alignment. A heat transfer correlation was developed from the measured data for flat plate finnedtubes with large fin pitch. The correlation yielded good predictions of the measured data.ht-307[5] was referred to determine the efficiency of given longitudinal /pin fin and compare it with the theoretical value for the given fin. Creed Taylor [6] researched on types of heat exchangers used in refrigeration system and its environmental impact. Friedrich Frass[7] studied principles in heat exchanger designing and constructing heat exchangers with transverse finned tubes in cross-flow, it is necessary to know correlations for calculating heat transfer and pressure drop. In addition to the common use of the Reynolds and Nusselt groups of dimensionless numbers, heat conduction in the fins also has to be accounted for calculating the heat transfer. A reduction coefficient termed fin efficiency is therefore introduced, by which the actual heat transfer coefficient is multiplied in order to get the apparent heat transfer coefficient. J.A. Livinstone [8] studied heat transfer enhancement with different types of fins and studied the heat transfer rates. Shiv Kumar Rathor [9] identified the advantages of low-finned tube Heat Exchangers over Plain tube (Bare Tube) units. To use finned tubes to advantage in this application, several technical issues were to be addressed. Shell side and tube side pressure, cost, weight and size of heat exchanger. Hamid Nabati[10] studied on results of heat transfer rates and pressure drop with different types of fins. The heat exchanger used for this research consists of a rectangular duct fitted with different shape pin fins, and is heated from the lower plate. The pin shape and the compact heat exchanger (CHE) configuration were numerically studied to maximize the heat transfer and minimize the pressure drop across the heat exchanger. A.D.Kadam[11] carried out simulation of fin and tube type heat exchanger with the help of computer simulation software. Sandeep R. Desai [12]carried out analysis of fluid elastic vibrations of heat exchanger tubes and its determination of modal parameters (natural frequency and damping ratios) of the tubes. Kevin Lunsford [13] published a technical paper on how to improve the heat exchanger performance with simulation programs commercial feasibility etc.k P M Wipplinger [14] designed a stainless steel finned tube heat exchanger. M V Ghori [15] experimented threedimensional CFD simulation and carried out investigation on heat transfer and fluid flow characteristics of tworow plain Tube and Fin heat exchanger using FLUENT software. Jiin-Yuh Jang [16] this paper suggests a method for finding the optimal louver angle of a fin heat exchanger by use of simplified conjugate-gradient method (SCGM) and a three-dimensional computational fluid dynamics model. AlaHasan [17] conducted the performance of two evaporatively cooled heat exchangers is investigated under similar operating conditions of air flow rates and inlet hot water temperatures. The heat exchangers are plain and plate-finned circular tube types which occupy the same volume. Chi-ChuanWang[18] the objective of this paper is to summarize the recent progress of fin pattern designs. Some of the designs are from the applied patents and some are from the recent literatures. The fin patterns include interrupted surfaces, enhanced wavy and the vortex generators. Benefits and the associated constraints of these designs are discussed. S.F Tsai [19]A three-dimensional numerical study was conducted to assess the heat transfer performance of extended fins in a two-row finned tube heat exchanger. Fins under investigation were plane and slit types. A finite volume discretization method and a SIMPLE-based solution algorithm were, respectively, applied to working differential equations and their discrete counterparts to compute the gas velocities and pressure. W. K. Ding [20].A circuit data structure (circuit connection network) for a general description of different circuit configurations in computer programs is presented. On basis of this data structure, a general tube-by-tube simulation model and the corresponding code for prediction of plate fin-and-tube heat exchanger performance are developed. Dimensional Parameters Threaded tube (mm) (Aluminium) Straight Tube (mm) (Aluminium) Length of the heat exchanger 1000 1000 Inner diameter of the inner tube, d i 16 16 Outer diameter of the inner tube, d o 26 25 Inner diameter of the outer tube, D i 36 36 Outer diameter of the outer tube, D o 42 42 Pitch distance between threads 2.4 - Depth of threads 1.5 - II. METHODOLOGY AND EXPERIMENTATION Geometry is ascertained based on literature survey, pipe sizes available in market and heat duty. Manufacturing and fabrication of threaded tube. Insertion of simple instrumentation for thermal measurement. Study of variation of Reynolds number on the Nusselt number. Reduction of data to construct useful heat transfer correlations. A schematic diagram of the experimental apparatus is shown in Fig 1. The test loops consists of a test section, hot water loop, cold water loop and data measuring systems. 78

Fig1. Schematic Diagram 1. Suction Pipe 2.Heaters 3. Cold Water Pipe 4. Hot Water Sensor 5. Cold Water Sensor 6. Cold Pipe Outlet 7. Threaded Heat Pipe. 8. M.S Outer Pipes 9. Non Threaded Heat Pipe 10. Delivery Pipe 11. FCV 12.Cold Pipe Inlet The test section is the water-to-water single-phase horizontal double pipe heat exchanger with two different configurations of the inner tube (threaded and non threaded). 2.1experimental Analysis A basic strategy to evaluate the heat exchanger s performance is through the study of parameters like Nusselt Number, Reynolds number, etc and their impact on the overall heat transfer coefficient of the heat exchanger. In result table, LMTD, overall heat transfer coefficient, Nusselt numbers across the inner tube are calculated. The collected data is processed, analyzed and presented Reynolds number (1500 31000 range) and mass flow rates (0.055 to 0.220 kg/s) III. DESIGN OF DOUBLE PIPE HEAT EXCHANGER BY KERN METHOD FOR GIVEN SPECIFICATIONS Hot fluid inlet temperature, Thi= 65 C = 338K Cold fluid inlet temperature, Tci= 30 C = 303K Mass flow rate for hot fluid (water), qh = 200LPH Mass flow rate for cold fluid (water), qc = 200LPH For the process conditions specified above, design the double pipe heat exchanger of 2000W heat duty. Thermo-physical properties Hot fluid (water) at 65 C Cold fluid (water) at 30 C Density, ρ (kg/m 3 ) 987.7 997.46 Thermal conductivity, k (W/m-K) 0.658 0.619 Specific heat, C p (J/Kg-K) 4182 4182 Viscosity, μ (Pa-s) 0.422 x 10-3 0.777 x 10-3 Prandtl number, Pr 2.6062 5.1078 Various heat transfer equations and empirical correlations are used to determine various parameters such as Reynolds number, Nusselt number, heat transfer coefficient etc. The readings and observations are taken prior to calculation of above mentioned parameters In present work, experimentation is done for single-phase water to water tube in tube heat exchanger with threaded and non threaded inner pipe. This analytical work is further studied in detail and presented. 79

results And Discussions Effect of flow rate on Nusselt Number Fig 2.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 200 LPH Fig.3.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 300 LPH Fig.4.Variation of inner tube Nusselt Number with Threaded and Straight inner tube flow rate for cold 400 LPH 80

Effect of Nusselt Number on inner tube side Reynolds Number for different configurations of the inner tube (threaded and Straight) Fig 5.Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 200 LPH. Fig 6. Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 300 LPH 81

Fig 7. Variation of inner tube Nusselt Number with Reynolds number for threaded and Straight tube for cold 400 LPH Effect of Convection coefficient for different configurations of the inner tube (threaded and Straight) Fig.8 Variation of inner tube Convection coefficient with Threaded and Straight inner tube flow rate for cold 200 LPH 82

Fig 9.Variation of inner tube Convection coefficient with Threaded and Straight innertube flow rate for cold 300 LPH F Fig.10.Variation of inner tube Convection coefficient with Threaded and Straight inner tube flow rate for cold 400 LPH Qavgfor different configurations of the inner tube (threaded and Straight) Fig 11.Variation of Q avg with Threaded and Straight inner tube flow rate for cold 200 LPH 83

Fig 12.Variation of Q avg with Threaded and Straight inner tube flow rate for cold 300 LPH Fig.13.Variation of Q avg with Threaded and Straight inner tube flow rate for cold 400 LPH 1. It is observed from the graph that the heat transfer rates of threaded pipe are more as compared to nonthreaded pipe, keeping the cold flow rate (LPH) constant. 2. It is also observed from the graphs, that heat transfer rate for threaded pipe is more than non-threaded pipe for respective cold mass flow rate. 3. It is clear that the Nusselt Number of inner tube increases with increasing flow rate of water through inner tube. IV. CONCLUSIONS An experimental study has been performed to investigate the performance (pressure drop and Nu characteristic) for the two configurations of inner tube in the single phase water-to-water tube in tube heat exchanger (TTHE) i.e. threaded; non threaded. A two to four times more heat transfer enhancement is observed experimentally for the aforesaid heat exchanger with increased pumping power requirement of twice or thrice. Thus this work concludes that significant heat transfer enhancement is achieved for the threaded inner tube in TTHE. The work can be extended further for heavy heat duty industrial applications with wide operating conditions, different fluids and more precise instrumentation, provided that time and money are not constraints. 84

REFERENCES [1] A.E. Bergles, The imperative to enhance heat transfer, Energy Conservation Through Heat Transfer Enhancement of Heat Exchangers, Turkey, 1998, pp. 547-563. [2] C.A. Balaras, A review of augmentation techniques for heat transfer surfaces in single-phase heat exchangers, Energy Conversion and Management, Vol. 15, 1990, pp. 899 906 [3] Wolverine INC Wolverine Tube heat transfer data book [4] Yonghan Kim, Yongchan Kim Heat transfer characteristics of flat plate finned-tube heat exchangers with large fin pitch, Vol. 1 26 January 2005 [5] HT 307 Finned tube heat exchanger. [6] Creed Taylor Measurement of finned-tube heat exchanger performance. [7] Friedrich Frass Principles of finned-tube heat exchanger design for enhanced heat transfer [8] J.A.Livingstone Effective Heat Transfer Enhancement in Finned Tube Heat Exchanger with different Fin Profiles Vol.2, Issue 2, 2013, pp:83-87 [9] Shiv Kumar Rathor Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger Vol. 2, Issue 1, July 2012 [10] Hamid Nabati Optimal pin fin heat exchanger surface 2008 [11] A. D.Kadam Perfomance simulation of fin and tube heat exchanger IJESR Vol.2, Issue 10, 2012 [12] Sandeep R Desai Determination of Modal parameters for finned tube heat exchanger tubes of various configurations UJME 2013 [13] Kevin Lunsford Increasing heat exchanger performance Bryan research and engineering, inc. 2006 [14] K P M Wipplinger Stainless steel finned tube heat exchanger design for waste heat recovery [15] M. V. Ghori Numerical Analysis of Tube-fin Heat Exchanger using Fluent [16] Jiin-YuhJang Optimum louver angle design for a louvered fin heat exchanger IJPS vol.6 pp 6422-6438 [17] AlaHasan Performance investigation of plain and finned tube evaporatively cooled heat exchangers [18] Chi-Chuan Wang Recent advances in fin-and-tube heat exchanger Vol.19, 2011, pp.291-301 [19] S. F Tsai A comparison study on fin surfaces in finned-tube heat exchangers IJNM Vol.9, 1999 pp.92-106 [20] W.K. Ding, J.F. Fan, Y.L. He, W.Q. Tao, Y.X. Zheng, Y.F. Gao, J. Song A general simulation model for performance prediction of plate fin-and-tube heat exchanger with complex circuit configuration Science Direct, 2011, pp.3106-3116. [21] R. K. Shah* and D. R Sekulib,University of Kentucky [22] PiotrWais, Fin-Tube Heat Exchanger Optimization PiotrWais,Cracow University of Technology, Department of Thermal Power Engineering, Poland [23] Kevin M. Lunsford, Increasing Heat Exchanger Performance Bryan Research & Engineering, Inc., Bryan, Texas [24] Comparative Analysis of Finned Tube and Bared Tube Type Shell and Tube Heat Exchanger Shiv Kumar Rathore, AjeetBergaley [25] M.R.Jafari Nasr and A. T. Zoghi Full Analysis Of Low Finned Tube Heat Exchangers,Research Institute of Petroleum Industry (RIPI), National Iranian Oil Company (NIOC) 85