X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Similar documents
INFRESCO-S-4kW X20034 Issue: 7

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

PROFESSIONAL 270 o PIR MOTION DETECTOR

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Installation Instructions

INSTALLATION & MAINTENANCE MANUAL HBL

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

Installation Instructions

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

HIB Enclosed Inverter User Guide

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Compact Security FloodLight

MANUFACTURED IN THE UK

3000W Dusk to Dawn Light Controller

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Differential Pressure Transmitter

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

RVS-AX Instruction Manual

Emergency lighting units EM converterled

MANUFACTURED IN THE UK

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM E1, E7, S1 and S7 Recessed Ceiling Luminaires

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

24 Hour Immersion Heater Time Controller

Emergency lighting units EM converterled

Installation Instructions

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

PBA Series Prelube Controls

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Specification Sheet for 2D LED Light

ASSA ABLOY. 7100SZ Series SafeZone External Sensor. Installation and Instruction Manual ASSA ABLOY. Patent Pending

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

25W LED Cross Bezel Bulkhead Light

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

Installation & User Instructions

ASSEMBLY AND INSTALLATION INSTRUCTIONS

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

LED Emergency Luminaires

Emergency lighting units EM powerled

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

SKC400U SLIDING GATE OPENER OWNER S MANUAL

RF Point Level Control with Sensor Monitor

Emergency lighting units EM series

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

PSU1 Power Supply Unit

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

SG-B1 SERIES / SG-A1 SERIES

Phoenix Inverter

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

MOTORTRONICS Solid State AC Motor Control

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Zip FlushMaster Surface mounted sensor

Emergency lighting units EM powerled

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

Emergency lighting units EM converterled

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Emergency lighting units EM powerled

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

10W LED Die Cast Small Rectangle Bulkhead Light

7100SZ Series SafeZone Installation and Instruction Manual

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

18W Round LED Slimline Emergency Light

Emergency lighting units EM converterled

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

WARRANTY INFORMATION...

EMPAC Metal enclosed capacitor bank for wind applications

DC POWER SUPPLY ALIMENTATION C.C.

Valve monitoring system VDK 200 A S02

Emergency lighting units EM converterled

OPERATING INSTRUCTION

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

ATM Lighting sp. z o.o

INDUSTRIAL POWER SUPPLIES SFL-SERIES

LED Twister II. User manual UK Version 1.0

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Solar Controller SUNGO S

ATM Lighting sp. z o.o

Instrumentation protection

Installation Instructions

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

Transcription:

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16 Page 1 of 9 KEY FEATURES Energy saving:- o Only provides heat when people are present. Extends lamp life. Temperature sensor:- o Lamps inhibited when ambient temperature exceeds set point. Soft-start/zero-voltage switch-off. Low-cost. Easy to install.

TECHNICAL SPECIFICATION Supply Voltage Switching Capacity Detection Range 230VAC +/- 10% @ 50/60Hz 4kW Max. 5 metres Detection Angle 100 Temperature Set Point 1 to 60 C Lamp On-Time Current Consumption (control circuit) Terminals 5 Minutes (fixed) 50mA 2.5mm 2 Rising Clamp Operating Temperature -20 to 40 C Protection Rating Gland Diameter Enclosure Dimensions (WxLxH) IP65 Max Cable Entry 2.5mm² 100x100x60 (mm) Introduction The infresco-p 4kW is part of a family of controllers designed to provide energy saving when used with Quartz Infrared Halogen Lamps. The P model has a built in PIR sensor allowing the lamps to automatically switch on only when people are present. In addition to the PIR, a temperature sensor monitors the outside temperature and inhibits the lamps when the temperature exceeds a pre-determined set point of between 1 C and 60 C. The microcontroller-based system incorporates zero-voltage switching and a soft-start function to eliminate the lamps initial high inrush current potentially increasing lamp life by as much as 30%. The lamps are switched on for a fixed time period of 5 minutes. This period is reset each time the PIR detects any further movement. Installation of the unit is simple and once installed is relatively maintenance-free Installation Important: Read carefully the following information before installing the unit. The passive infrared sensor (PIR) fitted in this unit detects changes of infrared energy through the Fresnel lens on the front face of the unit. The detection area and range depend significantly on its mounting position. The PIR not only detects movement of the human body, but also other heat sources similar to the human body. To prevent false activation, the unit must not be located directly facing or in close proximity to the heater lamps. Avoid locating the unit near to heating flues/exhausts, air conditioning units, moving trees/bushes and reflective surfaces. Note: The PIR cannot detect the presence of a human body that is not moving. To prevent malfunction of the PIR sensor, avoid subjecting it to rapidly-changing temperatures, strong shock or vibration or high humidity and temperature. WIRING DIAGRAM

PIR DETECTION AREA Horizontal Vertical Positioning The Infresco-P 4kW can be wall or ceiling-mounted. For wall mounting, the unit should be positioned 1-3 metres high. The diagram above shows the PIR s detection area. The unit should be fixed securely using the four mounting holes accessible from the front of the unit. Remove the lid to access the mounting holes. To ease installation, a mounting template is provided on the next page to locate the 4 mounting hole centres. IMPORTANT! When wall mounting, the unit must be orientated with the cable glands facing down.

MOUNTING TEMPLATE Use these template dimensions to locate the 4 mounting-hole centres prior to drilling. IMPORTANT! Drilling of any holes through the enclosure will immediately invalidate the warranty of the unit.

WIRING It is recommended that installation and maintenance of this equipment should be done with reference to the current edition of the I.E.E. wiring regulations (BS7671) by suitably qualified/trained personnel. These regulations contain important requirements regarding safety of electrical equipment (for International Standards refer to I.E.C/ directive IEC950). Warning! Isolate the mains supply before commencing any work on the unit. Failure to do so could result in serious injury or fatality. The unit is fitted with two cable glands. Only one cable should be fitted per gland to prevent degrading the unit s IP rating. See Wiring Diagram on the next page for an alternative wiring configuration using a junction box. The mains supply connects to the terminal block marked LINE. Connect the supply LIVE to the L terminal, NEUTRAL to the N terminal and EARTH to the E terminal. The lamps connect to the terminal block marked LOAD. Connect the load LIVE to the L terminal, NEUTRAL to the N terminal and EARTH to the E terminal. If two lamps are to be fitted they must be wired in parallel. Warning! Ensure all earth wires are connected to maintain earth continuity to the lamp fittings. Check all wiring and make sure the cable glands are tightened. Commissioning Turn the set point temperature preset (VR1) fully clockwise to select walk test mode. VR1 is located at the top of the printed circuit board as shown opposite. Replace the lid and switch on the mains supply to the unit. The controller will remain idle for 60 seconds to allow the PIR sensor to stabilise. After 60 seconds, the detection area can be walk tested to verify the PIR s coverage. Each time the PIR detects sufficient movement, the lamps switch on for 5 seconds. Note: Each time the lamps switch off, the PIR is inhibited for 5 seconds to prevent changes in infrared energy, given off by the lamps, from causing a false activation. Once the detection area has been verified, adjust the set point temperature as required. This will automatically disable walk test mode. The lamp on-time is fixed at 5 minutes. Note: If the ambient temperature exceeds the set point temperature, the lamps are inhibited.

TROUBLESHOOTING Problem: Lamps do not switch on. Solution: Check the LINE and LOAD wiring connections to the unit and ensure the mains supply is switched on. The ambient temperature may have exceeded the set point temperature. If necessary, increase the set point temperature (VR1). Check the lamps/lamp fittings. Contact your supplier. Problem: Lamps do not switch off. Solution: Ensure nobody enters the detection area for 5 minutes. This will allow the 5 minute on-time to expire. The PIR might be continually being re-triggered due to false activations. Mask the PIR lens and wait 5 minutes. If the lamps switch off after 5 minutes, the PIR is receiving false activations. See section Installation. Contact your supplier.

RECOMMENDATION & SAFETY REQUIREMENTS SUPPORTING DATASHEETS FOR PRODUCTS AND APPLICATIONS Other documents, which may be appropriate for your applications, are available on request. CODE IDENTITY DESCRIPTION X10255 SRA Safety requirements: Addressing the Low Voltage Directive (LVD) including, Thermal data/cooling, Live parts warning Earth requirements and Fusing recommendations. P01.1 COS UAL Conditions of sale. NOTE: It is recommended that installation and maintenance of this equipment should be carried out by suitably qualified personnel, with reference to the current edition of the I.E.E. Wiring Regulations BS7671. The regulations contain important requirements regarding the safety of electrical equipment. ELECTROSTATIC DISCHARGE (ESD) This product range has been identified has requiring protection from electrostatic discharge (ESD). They include integrated circuits (IC s) that may be damaged or degraded if mishandled. They are much less vulnerable when built in-circuit and suitable and sufficient precautions are taken when being handled. To address this matter, when the products are sold separately they are protected in an ANTI-STATIC polyethylene bag. Appropriate care should be taken when handling the units for installation. Further supporting data is available on request or on our website:- SWP05-06 A guide to ESD Not for general waste

PRODUCT APPLICATIONS Patio areas. Smoking shelters. Restaurants. Warehouses. Workshops. Garden lighting. Livery stables S o u t h p o r t B u s i n e s s P a r k, W i g h t M o s s W a y, S o u t h p o r t, P R 8 4 H Q T e l + 4 4 ( 0 ) 1 7 0 4 5 1 6 5 0 0 F a x : + 4 4 ( 0 ) 1 7 0 4 5 1 6 5 0 1 E m a i l : s a l e s @ u n i t e d - a u t o m a t i o n. c o m W e b : w w w. u n i t e d - a u t o m a t i o n. c o m