INFRESCO-S-4kW X20034 Issue: 7

Similar documents
X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

INFRESCO 2KW VARIABLE CONTROLLER Issue 3

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

INSTALLATION & MAINTENANCE MANUAL HBL

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

25W LED Cross Bezel Bulkhead Light

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Installation & User Instructions

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

HE-PSU(4.0) Power Supply & Battery Charger Installation, Commissioning & Operating Manual

2x 10W LED Slimline Floodlight Twin Flood

LOCAL SWITCH-DISCONNECTORS STANDARD DUTY, TYPE RDMP, 20-63A, IP65, 2-8 POLES TECHNICAL DATA

SDS Enclosed Star-Delta Starter User Guide

10W LED Die Cast Small Rectangle Bulkhead Light

24 Hour Immersion Heater Time Controller

Open Chassis Star-Delta Starter User Guide

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

HIB Enclosed Inverter User Guide

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

3000W Dusk to Dawn Light Controller

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Important Information

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Excellence in Level Measurement

MASTERBOX Series MASTERBOX SERIES DISTRIBUTION ASSEMBLIES

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Your Guide to the Installation, Care and maintenance of PERFORMA. Electronic Self Closing Fittings - Mains Powered 886V (343029) 885V (343027)

IP44 - IP66 Rated RCD, Power & Cable Management

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

U Series Installation Guide

18W Round LED Slimline Emergency Light

E N V I R O N M E N T A L P R O T E C T I O N F O R Y O U R C O N N E C T I O N S

Oil - kerosene burner

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Free Fall Fire Valve Range & Accessories

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Underfloor to desk 231

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Specification Sheet for 2D LED Light

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

PIL0478 ISSUE 01/ 07/16

IP 900 W/KS & IP 900 D/KS

Safety Lampholders and Pendants

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

Guidelines How To Wire DRH Modules

Installation Instructions: K-Safe-T-Drift

SAFETY SWITCHES / ISOLATORS A TECHNICAL DATA

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

I n s t a llat ion & O p e r atin g In s truc t ions

LASERMET MINIATURE LED SIGN POWER AND SWITCH UNIT. Installation Instructions

28W WORK LAMP Model: CTL28 Part No:

ATM Lighting sp. z o.o

1.1 Caution Statements

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

EX-REPAIR AND MAINTENANCE RECEPTACLES

Via Michelangelo Buonarroti, 52/B Cologno M.se (Mi) USER S MANUAL

ATM Lighting sp. z o.o

Actionpac LNS4. Panel Installation Datasheet. Actionpac LNS4 RELEASE 1.0 JUNE In partnership

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

ADS7 AC Contactor Starters

Zone 1 Linear Range - Installation Guide

10.3. Technical data Enclosed motor, heating and lighting control

The Powermatic User Guide Test Sieve Shaker

Light oil - kerosene burner

AUTOMATIC VENT CONTROLLER. Operation Manual

ATX DPD Series Distribution Panelboards Flameproof

Single Phase Electronic Speed Controllers

OPERATION & MAINTENANCE INSTRUCTIONS

Instruction Manual. EBV Gas Ballast Valves. EBV20 Gas Ballast Valve, 110 V, 50/60 Hz. EBV100S Gas Ballast Valve, 240 V, 50/60 Hz

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

LED emergency exit signage from Channel Safety Systems

LED Emergency Luminaires

LED Area Light. This is the fixture of choice for all of our dealerships. Contact Us:

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

IP41. Enclosed Switchgear. Hinged Lid IP41 Enclosures. for technical support call: +44(0) General Description.

OPERATION & MAINTENANCE INSTRUCTIONS

MANUFACTURED IN THE UK

XL Distribution enclosures WORKSHOP SPECIFICATIONS

K25000 & KD25000 Series

ATM Lighting sp. z o.o

Compact System NRGS 11-2 NRGS Original Installation Instructions English

ZB0050 / ZB0051 ZB0070 / ZB0071

CHECKLIST & COMPONENTS

Pan and Tilt Head CDD2416-T

Installation Manual for D154X Series Multi-Indicator, General Purpose Power Supplies

MANUFACTURED IN THE UK

Initial and Periodic Inspection and Testing of Electrical Installations ( ) Sample Test

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: ,

Transcription:

INFRESCO-S-4kW X20034 Issue: 7 User Manual Date: 17/01/17 Page: 1 of 7 KEY FEATURES Extends lamp Life. Ideal for controlling up to 2 x 2kW lamps. Soft-start/zero-voltage switch-off. Low-cost. Easy to install.

TECHNICAL SPECIFICATION Supply Voltage 230V ac +/- 10% 50/60 Hz Supply Fusing (recommended or equiv.) 20LCT or MCB20A (1pole, 440V) Switching Capacity Current Consumption (Control Circuit) Terminals Remote Switch Type Operating Temperature Protection Rating Gland Diameter Enclosure Dimensions (W x L x H) 4kW max. 50mA 2.5mm 2 rising clamp Latching -20-40 C IP65 Max. cable entry 2.5mm² 100 x 100 x 60 (mm) INTRODUCTION The Infresco-S-4kW is part of a family of controllers designed to provide energy saving when used with quartz infrared halogen lamps or other heating and lighting products. The S model switches to soft-start each time power is applied The microcontroller-based unit incorporates zero-voltage switching and a soft-start function to eliminate the lamps initial high inrush current potentially increasing lamp life by as much as 30%. Installation of the unit is simple and once installed is relatively maintenance-free. INSTALLATION Important: Read carefully the following information before installing the unit. The Infresco-S-4kW should be fixed securely using the four mounting holes accessible from the front of the unit. Remove the lid to access the mounting holes. To ease installation, a mounting template is provided on the next page to locate the 4 mounting hole centres. IMPORTANT! The unit must be positioned with the cable glands facing down. Wiring Warning! Ensure all earth wires are connected to maintain earth continuity to the lamp fittings. Isolate the mains supply before wiring this unit. The unit is fitted with two cable glands. Only one cable should be fitted per gland to maintain the unit s IP rating. When fitting two lamps, refer to wiring diagram for an alternative wiring configuration using a junction box. The mains supply connects to the terminal block marked LINE. Connect the supply LIVE to the L terminal, NEUTRAL to the N terminal and EARTH to the E terminal. The lamps connect to the terminal block marked LOAD. Connect the load LIVE to the L terminal, NEUTRAL to the N terminal and EARTH to the E terminal. If two lamps are to be fitted they must be wired in parallel. Check all wiring - particularly the line and load connections and make sure the cable glands are tightened. Fusing It is recommended that fast acting semiconductor type fusing (or MCB) be used in line with the LIVE supply for device and circuit protection. See SRA Data sheet X10255 for further information. Page 2 of 7

MOUNTING TEMPLATE & INSTALLATION Some components may not be fitted for this model. Mounting Template Use this template to locate the 4 mounting hole centres prior to drilling. IMPORTANT! The drilling of any additional holes will immediately void the warranty of this unit. The unit must be positioned with the cable glands facing down. Page 3 of 7

WIRING DIAGRAM Page 4 of 7

WIRING DIAGRAM BASIC INSTALLATION Link Must be fitted to Enable Unit Page 5 of 7

ADDITIONAL INFORMATION When using a remote switch it is important that an additional cable gland (not supplied) is used to ensure the IP rating is maintained. The rear of the enclosure contains the PCB; this will need to be removed before attempting to fit the additional cable gland. Remove the four fixing screws and remove the PCB. The knock-out can then be removed and the additional gland fitted as shown above. This should be done very carefully - ensure the gland is tightened up using a spanner. Refit the PCB and secure with the screws. Remove the link that is fitted into the INPUT/COM terminals and wire in the switch wires. Once the additional gland has been fitted the units should be mounted as shown above. This is the only time the unit should be mounted in this way. If the additional switch is not being used then the unit must be fitted with the gland facing down. Once the unit is wired, the lid should be refitted as shown. CE MARKING This product family carries a CE marking. For more information see RECOMMENDATIONS section and contact our sales desk. A Declaration of Conformity is available on request. RECOMMENDATION & SAFETY REQUIREMENTS Other documents, which may be appropriate for your applications, are available on request. CODE IDENTITY DESCRIPTION X10255 SRA Safety requirements: Addressing the Low Voltage Directive (LVD) including, Thermal data/cooling, Live parts warning Earth requirements and Fusing recommendations. P01.1 COS UAL Conditions of sale. NOTE: It is recommended that installation and maintenance of this equipment should be carried out by suitably qualified personnel, with reference to the current edition of the I.E.E. Wiring Regulations BS7671. The regulations contain important requirements regarding the safety of electrical equipment. Not for general waste Page 6 of 7

PRODUCT APPLICATIONS Garden Lighting Patio Areas Smoking shelters Restaurants Warehouses Workshops Livery stable S o u t h p o r t B u s i n e s s P a r k, W i g h t M o s s W a y, S o u t h p o r t, P R 8 4 H Q T e l : + 4 4 ( 0 ) 1 7 0 4 5 1 6 5 0 0 F a x : + 4 4 ( 0 ) 1 7 0 4 5 1 6 501 e m a i l : s a l e s @ u n i t e d - a u t o m a t i o n. c o m W e b : w w w. u n i t e d - a u t o m a t i o n. c o m