UNIVERSAL Three Way Diverter Valve For Pressure Balance Shower Systems STYLE No. GUDV65 Installation Guidelines Inspect this product to assure you have all the parts required for proper installation. Refer to the specification and assembly drawings attached. Product is sold partially assembled but shown fully disassembled for illustrative and service purposes only. This product must be installed by a professional licensed contractor. Be sure your installation conforms to all federal, state, and local codes. In the State of Massachusetts, all installations must comply with the rules and regulations set forth within 248 CMR. Check incoming water pressure. FUNCTION: SPECIFICATIONS: Fittings Hole Diameter: Ø2 1/2" * Inlet Connection Size & Type: 1/2" Female NPT Outlet Connection Size & Type: 1/2" Female NPT Unrestricted Maximum Flow at 45psi: 16.9gpm Valve Material: Ceramic Water Pressure Range: 20psi MIN - 80psi MAX Recommended Water Pressure: 45psi * Ø2 1/2" hole is required for servicing the valve REQUIRED PLUMBING DETAILS: Universal Three Way Pressure Balance Diverter Valve Trim STYLE No. UNDV3P Universal Pressure Balance Valve STYLE No. GUPB81 or, Universal Pressure Balance with Diverter Valve STYLE No. GUPB87 IMPORTANT: To ensure this product is installed properly, you must read and follow these guidelines. The Universal Pressure Balance Valves (GUPB81 and GUPB87) control on/off and mix hot and cold water. Mixed water flows out at a fixed volume to the diverter valve (GUDV65) which has 3 positions/outlets to direct water flow to a maximum of 3 devices: Shower head, handshower and secondary shower head. Water cannot flow out of the devices simultaneously (i.e. out of the shower head and handshower together). The GUDV65 can only be connected to the top outlet port of the GUPB81 and GUPB87. The GUPB87 features an integrated diverter for use with a tub spout that does not have a built in diverter. ROUGH-IN: Valve rough-in depth is measured from the centerline of the inlets to the surface of the finished wall and varies depending on the trim being used. DIVERTER VALVE The owner/user of this product must keep this information for future reference. This product can only be used with either the Universal Pressure Balance Valve (GUPB81) or the Universal Pressure Balance with Diverter Valve (GUPB87). This product requires a compatible wall valve trim and trim plate. ALL PRODUCTS SOLD SEPARATELY. CENTER OF INLET ROUGH-IN DEPTH FINISHED WALL This product, the pressure balance valve (GUPB81 or GUPB87) and the associated trims must be on-site prior to rough-in. This allows the installer to visualize the installation. CENTER OF INLET ROUGH-IN DEPTH PRESSURE BALANCE VALVE These guidelines have been prepared for the professional contractor to aid in the installation of: UNIVERSAL THREE WAY DIVERTER VALVE FOR PRESSURE BALANCE SHOWER SYSTEMS (STYLE No. GUDV65). All dimensions are based on original specification and are subject to change and variation. Please consult your Design Associate for current specifications. 5.6.2013 PRODUCT SUPPORT 800.927.2120 8am - 6pm EST Page 1 of 2 Rev - 04
UNIVERSAL Three Way Diverter Valve For Pressure Balance Shower Systems With.25, Flyte, Henry, Opus & R.W. Atlas Trims: GUDV65 Rough-In Depth: 3 1/8" - 3 5/8" GUPB81/87 Rough-In Depth: 2 3/8" - 2 7/8" With All Other Trims: GUDV65 Rough-In Depth: 2 5/8" - 3 5/8" GUPB81/87 Rough-In Depth: 1 7/8" - 2 7/8" You must have the pressure balance valve (GUPB81 or GUPB87) on hand in order to install the diverter valve (GUDV65). 1. Make sure the valve is positioned according to the valve markings with the inlet port situated so that mixed water flows into the inlet. Installation Guidelines 4. After the rough-in is completed, turn on the hot and cold supplies and check for leaks. Allow the water to run so the lines can be flushed completely. 5. Verify all the valves are functioning properly. 6. Attach the stem extension to the cartridge stem with the screw then install the tile guard. STEM EXTENSION SCREW TILE GUARD If further assistance is required, please contact Product Support at 1-800-927-2120 (8am-6pm EST). MIXED WATER INLET 2. Rough-in the diverter valve to an appropriate depth based on the trim being used. 3. The cartridge stem and threaded tube on the diverter valve can be cut to various lengths depending on the style of trim. Refer to the Installation Guidelines of individual trims for cutting dimensions and related information. CARTRIDGE STEM THREADED TUBE These guidelines have been prepared for the professional contractor to aid in the installation of: UNIVERSAL THREE WAY DIVERTER VALVE FOR PRESSURE BALANCE SHOWER SYSTEMS (STYLE No. GUDV65). All dimensions are based on original specification and are subject to change and variation. Please consult your Design Associate for current specifications. 5.6.2013 PRODUCT SUPPORT 800.927.2120 8am - 6pm EST Page 2 of 2 Rev - 04
service parts STYLE GUDV65 Universal Three Way Diverter Valve for Pressure Balance Shower Systems STYLE GUDV66 Universal Three Way Diverter Valve for Thermostatic Shower Systems
WELCOME TO WATERWORKS For over three decades, Waterworks has transformed the bath through an absolute commitment to design authenticity, innovation and quality. A blend of scholarly appreciation and applied experience guarantees mechanical integrity, meticulous craftsmanship, and timeless designs. TO ORDER PARTS CALL 1 (800) 927-2120 (EXT 2) Order by part number and specify color, finish, or other options if required. PRODUCT SUPPORT Our Product Support team provides troubleshooting and technical problem resolution, including replacement parts and installation recommendations throughout the life of your product. Product Support is available Monday through Friday, 8AM-6PM EST. LIMITED LIFETIME WARRANTY Our warranty covers repair and replacement of Waterworks products if within the applicable coverage period and deemed defective by Waterworks. Waterworks will, at its option, repair or replace such products; this does not include installation costs, labor charges, or other incidental or consequential costs. To obtain your complete warranty or inquire about warranty service, please visit us at www.waterworks.com or contact our Product Support Team. 1
STYLES: GUDV65, GUDV66 *FINISH/COLOR MUST BE SPECIFIED WHEN ORDERING ++SUPPLIED AS A PAIR MAIN KITS 103666 REPLACEMENT DISC FOR CONCEALED DIVERTER 890831 WALL VALVE EXTENSION 103666 REPLACEMENT DISC FOR CONCEALED DIVERTER 103668 TILE GUARD FOR DIVERTER 2 PRODUCT SUPPORT: 1 (800) 927-2120 (EXT 2) 3
STYLES: GUDV65, GUDV66 *FINISH/COLOR MUST BE SPECIFIED WHEN ORDERING ++SUPPLIED AS A PAIR KIT COMPONENTS 103666 REPLACEMENT DISC FOR CONCEALED DIVERTER KIT COMPONENTS 890831 WALL VALVE EXTENSION O-RINGS 657531 HANDLE CONNECTOR COUPLER SCREW CERAMIC DISC CERAMIC DISC 4 PRODUCT SUPPORT: 1 (800) 927-2120 (EXT 2) 5
STYLES: GUDV65, GUDV66 *FINISH/COLOR MUST BE SPECIFIED WHEN ORDERING ++SUPPLIED AS A PAIR SERVICE PARTS INDEX STYLE DESCRIPTION PG NOTES 657531 103666 103668 890831 HANDLE CONNECTOR REPLACEMENT DISC FOR CONCEALED DIVERTER TILE GUARD FOR DIVERTER WALL VALVE EXTENSION 5 4 3 5 DOCUMENT: SPGU10_REV01 6 PRODUCT SUPPORT: 1 (800) 927-2120 (EXT 2) 7
STYLES: GUDV65, GUDV66 *FINISH/COLOR MUST BE SPECIFIED WHEN ORDERING ++SUPPLIED AS A PAIR NOTES NOTES 8 PRODUCT SUPPORT: 1 (800) 927-2120 (EXT 2) 9
PRODUCT SUPPORT 60 BACKUS AVENUE DANBURY, CT 06810 1 (800) 927-2120 (EXT 2)