SSV SL-022 Safety Shut-off Valve

Similar documents
Safety Shut-off Valve SL/SID/RSL

Safety Shut-Off Valve HON 711

Safety Shuttoff Valve Type SL - IZN/M/H.1

Safety Shut-Off Valve HON 711 S2

Fluxi 2000/TZ Turbine Gas Meter

B58 Series Regulator Residential Regulator

CP400 Series Commercial/Industrial Pressure Loaded Pressure Reducing Regulators

B57 Series Regulator Residential Regulator

B57 Series Regulator Residential Regulator

CS800 Series Commercial/Industrial Pressure Reducing Regulators

GOVERNORS. Line Pressure Regulators Mod. Stab

Delta Commercial & Industrial Rotary Meter

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

Delta Commercial & Industrial Rotary Meter

cs200 series commercial / Industrial pressure reducing regulators

627 Series Pressure Reducing Regulators

SLAM-SHUT VALVE. Type OSE

P200 Pressure Regulator

Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)

3/2-way Solenoid Valve for pneumatics

627 Series Pressure Reducing Regulators

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves

P200 Pressure Regulator

P200 Pressure Regulator

627 Series Pressure Reducing Regulators

BM-01. Electrically operated valves 3/2-way G 1/8, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

BM-02. Electrically operated valves 3/2-way G 1/4, Nl/min ( Cv) Technical data for series. Order code BM HNR-162

Gas pressure regulator R 100 / R 100U / R 100UD

Temperature Sensors. Information Sheet

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

T205 Series Tank Blanketing Regulators

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Series 240 Type 3351 Pneumatic On/off Valve

T205VB Series Tank Blanketing Vacuum Breakers

F300 Pressure Regulator

Y610A, Y611A, and Y612A Series Vacuum Service Equipment and Relief Valves

GAS PRESSURE REGULATOR RMG RMG 512b DN 25 to DN 100. RMG 512c DN 150 and DN 250 SERVING THE GAS INDUSTRY WORLDWIDE

ACTUATOR HON 670 /

Gas Pressure Regulator RMG

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

type 630r relief Valve

Series

3 Edition Product brochure GB AGA

Electrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)

Manually operated safety shut-off valve HSAV HSAV/5

Flowmeter for Gases. Type Type can be combined with... Type 8802-YG Process control valve. Type 5281 Solenoid valve

Servo-operated 2/2-way solenoid valves Type EV220A

600, 630. Diaphragm Valve, Plastic

T205 Series Tank Blanketing Regulators

Gas and air filter. GF/1: Rp 1/2 - Rp 2 GF/3: DN 40 GF/4: DN 50 - DN 100 GF: DN DN 200

Series RE-10. Valve terminals > Technical details. Order code RE-10/**-***-*** Temperature range Medium +5 C C

N086, N186, N786. Pressure retaining valve, Plastic

2/2- and 3/2-way Ball Valve with pneumatic rotary actuator, plastic body, DN 10-50

2/2-way Solenoid Valve with servo diaphragm

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Gas Pressure Governors

Type 310A-32A Pressure Reducing Regulator

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Flanged Ball Valves KHBF / KHMF / KHMFF

Type HSR Pressure Reducing Regulator for Residential, Commercial, or Industrial Applications

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

2/2 Pressure operated valves

Battery Life in Water Communication Modules

Series 240 Pneumatic On-off Valve Type 3351

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

3/2 Way Ball Valves KHB3K

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

SAFETY SHUT-OFF VALVE HON

Tightness control TC. Product brochure GB Edition 12.10

Selection Tool. on the Internet at in the section MÄDLER -Tools. Other sizes and designs on request. Connecting Shafts Page 766

KTR Torque Limiters Overload Protection Systems

700 LARGE SIZE SERIES

Maxifluss Rotary Plug Valves VETEC Types 72.3/R and 72.4/R

ACTUATOR HON

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

T200 Pressure Regulator

ARI-STEVI 440 / 441 DVGW type approval

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Performance Literature for J125 Gas Pressure Regulators 1½ and 2 Sizes. Catalogue

B42 Series Regulator Residential Regulator

Maxifluss Rotary Plug Valves VETEC Types 73.3/M and 73.7/M

Differential pressure gauges with Bourdon tube

Type 6213 EV, 6281 EV

Injection Oilers, Micro Pumps

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

P99 Pressure Reducing Regulator

Transcription:

SSV SL-022 Safety Shut-off Valve These shut-off valves are designed for transmission and distribution networks, as well as commercial and industrial use. KEY BENEFITS High accuracy shut-off Low pressure loss Operating temperature up to -20 C Easy maintenance Approved by German DVGW DESCRIPTION These models, designed for both high and low shut-off, automatically interrupt the gas flow when the outlet pressure of the regulator is outside the range of acceptable values. Technical Features Inlet pressure range OPSO* range UPSO* range Pu: up to 101.2 bar Pdso: 20 mbar 60.0 bar Pdsu: 5 mbar 20.0 bar Accuracy class AG 1 to AG 30 Operating temperature Ambient temperature Acceptable gases -20 C to +60 C -30 C to +60 C (body material) Natural gas, propane, butane, air, nitrogen and all non-corrosive gases. * OPSO/UPSO: Over- and under-pressure shut-off Connections Sizes DN 25, 50, 80 Orifice diameter (mm) Ø 28,, 65 Body lengths Flanges Materials Body See table 16, 25, 150, 300, 600 EN-GJS-0-15, GS21 Mn5 N Actuator SSV Steel, zinc coated / Al Mg Si F 28 Orifice Internal parts Seals / O-Rings Diaphragm Brass, steel, zinc coated/stainless steel Brass, Steel, zinc coated/stainless steel NBR rubber/viton NBR rubber/nbr rubber, reinforced fabric SPECIFICATIONS knowledge to shape your future

SAFETY SHUT-OFF VALVE TYPE SL-022 Selecting the SSV SSV Pumax / Orifice - ø Design SL-IZN.1 101.2 bar SSV for over-pressure shut-off SL-IZM.1 (Command range Wdo 35 mbar 60 bar) SL-IZH.1 SSV 022 16 bar SSV for over-pressure and under-pressure shut-off Command range Wdo 0.035 bar - 1.7 bar Wdu 0.01 bar - 0.22 bar DN 25 DN 50 DN 80 16 150 300 Orifice Ø 28 mm Orifice Ø mm Orifice Ø 65 mm * with protection of safety relief valve, type 285 D Flange Flanges according to DIN, 16, with Form C seal Flanges according to 150, 300, and 600 RF Device designation example: Safety shut-off valve, type SL-IZM.1, DN 50, 16

SSV TYPE SL Design and Function The SL-IZ type of safety shut-off valves are designed to automatically interrupt the gas flow in the gas pressure regulating systems as soon as the pressure in the system to be protected reaches an upper response pressure (over-pressure). The devices consist of a control unit 1, which pneumatically controls a switching unit 2, and releases a flap valve 3. The switching unit and the control unit are mounted on the actuator body 4. A special tool (spring tension spanner) is required to assemble the torsion spring (12). 12 7 16 10 6 5 8 13 9 X 1 2 A measuring line with a 90 shift 17 B blow-off ventilation line with a 90 shift Y The pressure to be monitored is transmitted to a diaphragm measuring unit 5 ; connection A measures the connection. 4 3 11 12 The response pressure is controlled by the force of the setting spring 6 at the top of the measuring unit. Use the setting screw 7 to adjust the response pressure. 19 section X - Y 18 Turn the setting screw 7 clockwise to increase the response pressure, or counter-clockwise to reduce it. When the set response pressure is exceeded, the diaphragm unit 5 is raised and an overflow volume is released through the nozzle 8. The resulting increase in pressure acts on the switching diaphragm 9. The switching diaphragm acts against the force of a weak cylindrical coil spring 10, or against the friction force of a locking unit. When pressure acts on the switching unit, the detent 11 is released and the flap valve 3 is closed by the force of one or more ( 300 and higher) torsion springs 12 *. Tightness is guaranteed even at a very low operating pressure due to the dimensions of the closing springs. Use the manipulation valve 18 to compensate for the pressure at the valve flap. Diaphragm Break Protection The safety shut-off valves meet all requirements of the DIN 3381 standard, June 1984 Edition. According to this standard, devices must have a unit that closes the SSV control unit 1 in case the diaphragm is damaged 5. For this reason, these types of safety shut-off valves are equipped with an overpressure valve 13 in the control unit 1. If the comparator diaphragm 5 is damaged, gas flows to the top of the diaphragm. Pressure builds up, thereby opening the over-pressure valve 13. In addition, the switching process is triggered by the overflowing volume, which flows through the bore 16. The pressure in the switching unit 2 is further decreased by means of a small bore 17, which is located in the switching unit. The gas is discharged through the blow-off/ ventilation connection B. This connection also carries gas if the existing control pressure (e.g., pressure test) is above the set response pressure. * A special tool (spring tension spanner) is required to assemble the torsion spring (12). SPRING RANGE AND ACCURACY CLASS AG Type SL-IZN.1, M.1, H.1 Type Spring range Wdso (bar) Spring Number Colour Wire Ø mm Range) Wdso (bar) Accuracy Class SL-IZN.1 0.035 0.25 955-202-36 red 1.8 0.035 0.1 AG10 0.2-0.8 955-202-37 green 2.5 >0.1 0.8 AG 5 SL-IZM.1 0.6 6.6 955-202-38 yellow 3.6 0.6 6.6 AG 5 SL-IZH.1 3.5 10.5 955-201-68 black 6.0 3.5 10.5 AG 2.5 10.5 21.0 955-201-69 grey 7.0 >10.5 60.0 AG 1 18.0 60.0 955-202-84 yellow 10.0

SSV TYPE 022 For over-pressure and under-pressure shut-off Description The SSV 022 is a new and improved version of the tried and tested SSV for upper and lower shut-off of the 133/233 series. It is mounted on the valve body by means of an adapter and can be turned 90. Due to the SSV cap 9 which is equipped with a diaphragm, it is not necessary to install a ventilation line from the SSV into the open. Function The pressure to be monitored Pa is transmitted to the external connection 9 of the SSV-022. When the set Pso / Psu switching pressure is exceeded or falls below the limit, the valve rod 2 is released and pushed against the release lever 3 of the SSV valve disk arm due to the force of the closing spring. The resulting force of the torsion spring 4 turns the valve disk arm and the valve disk 5 around the reset shaft 6 against the nozzle 7 and closes the SSV. Technical Data Pressure stage 16, 150 Nominal width DN 25, 50, 80 Model Flange in DIN and Pe max 16 bar Wdo 0.04 bar to 1.7 bar Wdu 0.01 bar to 0.22 bar Construction Body EN-GJS-0-15 Measuring unit: Al Mg Si 1 F 28 SSV-Body Hot-pressed brass Interior parts Steel, brass, aluminium, perbunan Operating temperature -20 C to +60 C Ambient temperature -30 C to +60 C Connection Po - pulse: G 1/4 Spring Ranges/Shut-off Pressure Groups Spring Range Pso/Spring-No./Colour OPSO Range/Accuracy Class AG 60 mbar 955-200-22 red mbar 0 mbar AG 10 50 120 mbar 955-200-23 blue mbar 0 mbar AG 10 100 450 mbar 955-200-24 green mbar 0 mbar AG 10 350 1000 mbar 955-203-41 black > 0.4 bar 1.0 bar AG 5 800 1700 mbar 955-203-42 yellow > 1.0 bar 1.7 bar AG 2.5 Spring Range Pso/Spring-No./Colour UPSO Range/Accuracy Class AG 10 50 mbar 955-200-32 red 10 mbar 20 mbar AG 30 120 mbar 955-203-51 yellow > 20 mbar 220 mbar AG 15 100 220 mbar 955-203-52 brown PRESSURE LOSS OF THE SAFETY SHUT-OFF VALVE TYPE SL - 022 These types of safety shut-off valves have very low pressure loss. Use the following formula to calculate the pressure loss: p (P inlet - P outlet) = ( Q 1 )2 x = [bar] Cg Pi abs Example Inlet pressure Pu = 3.0 bar Flow rate Q = 500 m 3 /h Natural gas p = ( 500 )2 x 1 = 0.0092 bar 2600 4 Q = Flow rate (m 3 /h Natural gas) Cg = Flow constant (see table) DN 25 50 80 Cg 600 2600 5100 Note: The max. velocity of SL - 022 is 70 m/s.

DIMENSIONS AND WEIGHTS Safety Shut-off Valve, Type SL-IZN.1, M.1, H.1 25 50 DN A B C D E F G H Orifice 28 16, 150 160 230 300, 500, 600 230 300 SL-IZ N.1 M.1 2 245 16 150 300, 0 600 SL-IZ N.1, M.1, H.1 H.1 < 280 285 105 110 57.5 57.5 80 65 310 380 285 330 145 100.0 100.0 95.5 105.0 105.0 155 145 145 154 181 54.0 76.0 62.0 62.0 1 1 16 =110 110 > 150 110 I 105 108 135 135 E 50 for spring replacement C B G H F D A SSV Type SL

Safety Shut-off Valve, Type SL DN Shaft Ø Reset Shaft Spanner Size SW (mm) 16 / 150 Weight in kg 63 300 / 600 25 8 square 6 11 17 50 8 square 6 16 20 80 11.8 two-edged 9 26 39 Installation Position DN 25 and DN 50 = no restriction.»dn» 80 = for a vertical installation, the flow direction must be upwards (weight of the SSV flap has an opening effect), and an additional spring is required. DN 80 > = no restriction. 30 Safety Shut-off Valve, Type SSV 022 Nominal Width A B C D E F G Weight/ Kg) DN 25 160 252 177 57.5 145 287 88 11 DN 50 230 255 180 150 290 91 15 DN 80 310 310 236 100 180 345 147 25 B 11 D Installation Position DN 25 and DN 50 = no restriction. DN 80 = for a vertical installation (flow direction upwards), an additional spring is required. For all other positions, there are no restrictions. DN 80 > = no restriction. E 450 A C 470 (for spring replacement) G Our company is the world s leading provider of smart metering, data collection and utility software systems, with over 8,000 utilities worldwide relying on our technology to optimize the delivery and use of energy and water. To realize your smarter energy and water future, start here: www.itron.com For more information, contact your local sales representative or agency: ITRON GmbH Hardeckstraße 2 D-76185 Karlsruhe Germany Phone: +49-721 5981 0 Fax: +49-721 5981 189 While Itron strives to make the content of its marketing materials as timely and accurate as possible, Itron makes no claims, promises, or guarantees about the accuracy, completeness, or adequacy of, and expressly disclaims liability for errors and omissions in, such materials. No warranty of any kind, implied, expressed, or statutory, including but not limited to the warranties of non-infringement of third party rights, title, merchantability, and fitness for a particular purpose, is given with respect to the content of these marketing materials. Copyright 2013, Itron. All rights reserved. GA-SSVSL022-03-EN-11-13