GENERATOR INTERCONNECTION APPLICATION

Similar documents
Electric Utility Contact Information Indiana Michigan Power

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

PSNH INTERCONNECTION REQUEST

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kva to 10 MVA or less)

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

If any further information is required for CHELCO to fulfill its reporting requirements, please let us know.

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Louisville Gas and Electric Company

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 25 kw)

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

Please Refer to Attached Sample Form

Form C Renewable Energy Micro-Generation Connection Application Distribution System

Section 6. Generation Interconnection

Spec Information. Reactances Per Unit Ohms

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

GENERATOR DATA MAY 10, 2018

GENERATOR DATA SEPTEMBER 29, 2015

Request for Payment Instructions Rule 21 Non-Exporting Generators Submittal Instructions

Please Refer to Attached Sample Form

TERMS AND CONDITIONS

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

APPLICATION Net Energy Metering Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Request for Payment Instructions form. Rule 21 Non-Exporting Generators Submittal Instructions

APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

MICHIGAN ELECTRIC UTILITY

NET METERING APPLICATION

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

Synchronous Generators I. Spring 2013

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

Micro-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Synchronous Generators I. EE 340 Spring 2011

Net Metering Service. Customer Information Package

California PUC Rule 21 Generating. Facility Interconnection Application Guide. Technical Note

TECHNICAL TERMS AND ABBREVIATIONS

Request for Payment Instructions Rule 21 Export Submittal Instructions

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Noble County Rural Electric Membership Corporation

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

ELG4125: Flexible AC Transmission Systems (FACTS)

Electrical Power Electric power electrical electric power Electric power electric electric

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Municipality Generator Interconnection Application Single Meter Application Part I

August 2, 2001 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Product Information Packet CP500808LR-4 800HP,897RPM,3PH,60HZ,G50,A95260M,TEFC,F

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

PM734E - Winding 28. Technical Data Sheet APPROVED DOCUMENT

Optimizing Emergency Power Systems for Health Care Applications

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

APPLICATION Net Energy Metering (NEM2) Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

Interconnection Process for Customer-Owned Generation (QFs)

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

NET METERING ENROLLMENT APPLICATION REFERENCE GUIDE

Michigan Renewable Energy Case Study

PI736F - Winding 312. Technical Data Sheet

S5L1D-G4 Wdg Technical Data Sheet

Scheme - I. Sample Question Paper

Umatilla Electric Cooperative Net Metering Rules

HCI634G - Technical Data Sheet

Measurement and Analysis of the Operation of a Single-Phase Induction Motor

PJM Generator Interconnection R81 Emilie (Fords Mill) MW Impact Study Re-Study

Unit III-Three Phase Induction Motor:

Product Information Packet ECP50504L-4 500HP,1789RPM,3PH,60HZ,5010,TEFC,F1

DHANALAKSHMI COLLEGE OF ENGINEERING MANIMANGALAM. TAMBARAM, CHENNAI B.E. ELECTRICAL AND ELECTRONICS ENGINEERING

P734H - Technical Data Sheet

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

XR500B Universal Voltage Regulator

Street Address. City-Village-Township

ELECTRICAL POWER and POWER ELECTRONICS

MICHIGAN ELECTRIC UTILITY

Lesson 16: Asynchronous Generators/Induction Generators

SE2000BX Static Exciter

Overview of State Distributed Generation Interconnection Rules

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, Sessions Session 1-8:30-9:25 a.m. Motors 101 Session

UCDI224E - Technical Data Sheet

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

PERFORMANCE - DELTA CONNECTION LOAD HP AMPERES RPM % % SPEED TORQUE - WYE / DELTA CONNECTION RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT 61 / 219

HCI634H - Technical Data Sheet

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI274H - Technical Data Sheet Winding 06

Transcription:

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW Also Serves as Application for Category 3 Net Metering (Note: Category 3 Net Metering Program only available to Methane Digester Projects) Electric Utility Contact Information DTE Energy Interconnection Coordinator One Energy Plaza, SB 490 Detroit, MI 48226 Interconnection Hotline: 313.235.4333 Interconnection Email: interconnect@dteenergy.com For Office Use Only Application No. Date & Time Application Received Customer / Account Information Electric Utility Customer Information: ( As shown on utility bill ) Customer Name ( Last, First, Middle): Customer Mailing Address: Customer E-Mail Address: ( optional ) Electric Service Account # Electric Service Meter Number: Are you applying for the Net Metering Program? o Yes o No Are you interested in selling Renewable Energy Credits (REC's) o Yes o No Will you have an Alternative Electric Supplier? o Yes o No Notes: Enter name ONLY if your energy is supplied by a 3rd party, not the utility. You must apply to both the Distribution Utility and your Alternate Energy Provider (if applicable) for Net Metering Alternative Electric Supplier Name Physical Site Service Address (if not Billing Address): Generation System Site Information Annual Site Requirements Without Generation in Kilowatthours Peak Annual Site Demand in Kilowatts (only for customers billed on demand rates) kwh/year kw/year Attached Site Plan: Page # Attached Electrical One-Line Drawing (See the Appendix D for a sample Inverter Type Project) Page # (Per MPSC Order in Case No. U-15787- The one-line diagram must be signed and sealed by a licensed professional engineer, licensed in the State of Michigan or by an electrical contractor licensed by the State of Michigan with the electrical contractor's license number noted on the diagram.) Synchronous/Induction Generators: Must fill out Appendix A or B and provide a Detail One-Line Diagram Page # See Appendix E and F for a sample the Detail One-Line Diagram for Synchronous or Induction projects Note: The following information on these system components shall appear on the preliminary Detail One-Line Diagram Breakers - Rating, location and normal operating status (open or closed) Buses - Operating voltage Capacitors - Size of bank in Kvar Circuit Switchers - Rating, location and normal operating status (open or closed) Current Transformers - Overall ratio, connected ratio Fuses - normal operating status, rating (Amps), type Generators - Capacity rating (kva), location, type, method of grounding Grounding Resistors - Size (ohms), current (Amps) Isolating transformers - Capacity rating (kva), location, impedance, voltage ratings, primary and secondary connections and method of grounding Potential Transformers - Ratio, connection Reactors - Ohms/phase Relays - Types, quantity, IEEE device number, operator lines indicating the device initiated by the relays. Switches - Location and normal operating status (open or closed), type, rating Tagging Point - Location, identification

GENERATOR INTERCONNECTION APPLICATION FOR ALL PROJECTS WITH AGGREGATE GENERATOR OUTPUT OF MORE THAN 150 KW BUT LESS THAN OR EQUAL TO 550 KW Also Serves as Application for Category 3 Net Metering (Note: Category 3 Net Metering Program only available to Methane Projects) Generation System - Manufacturer Information System Type ( Solar, Wind, Biomass, Methane Digester, etc ): Generator Type ( Inverter, Induction, Synchronous ): Generator Nameplate Rating: Expected Annual Output in Kilowatthours A.C. Operating Voltage: Wiring Configuration ( Single Phase, Three Phase ): Certified Test Record No.(Testing to standard UL1741 scope 1.1a) kw kwh/year Inverter Based Systems: Manufacturer Model ( Name / Number ) Inverter Power Rating (kw) Induction & Synchronous Based Systems Manufacturer Model ( Name / Number ) Installation Information Project Single Point of Contact: ( Electric Utility Customer, Developer, or other ) Name: Company ( If Applicable ): Phone Number: E-Mail Address: Requested In Service Date: Licensed Contractor ( Name of Firm or Self ): Contractor Name ( Last, First, MI ): Contractor Phone #: Contractor E-Mail: o Attached $150 Interconnection Application Fee or Customer and Contractor Signature and Fees o Attached $100 combined Interconnection & Net Metering Program application fees (Check # / Money Order # ) ($75 Interconnection Application Fee plus $25 fee required if selecting net metering) ( Sign and Return complete application with Application Fee to Electric Utility Contact ) To the best of my knowledge, all the information provided in this Application Form is complete and correct. Customer Project Developer/Contractor (If Applicable)

APPENDIXES Appendix A: Technical Information for Synchronous-Type Generators Appendix B: Technical Information for Induction-Type Generators Appendix C: Sample Site Plan Appendix D: Sample One-Line diagram for Inverter Type Project Appendix E: Sample One-Line diagram for Synchronous Type Project Appendix F: Sample One-Line diagram for Induction Type Project

Appendix A Synchronous Generators Generator Information a. Generator Nameplate Voltage a. b. Generator Nameplate Watts or Volt-Amperes b. c. Generator Nameplate Power Factor (pf) c. d. RPM d. Technical Information e. Minimum and Maximum Acceptable Terminal Voltage e. f. Direct axis reactance (saturated) f. g. Direct axis reactance (unsaturated) g. h. Quadrature axis reactance (unsaturated) h. i. Direct axis transient reactance (saturated) i. j. Direct axis transient reactance (unsaturated) j. k. Quadrature axis transient reactance (unsaturated) k. l. Direct axis sub-transient reactance (saturated) l. m. Direct axis sub-transient reactance (unsaturated) m. n. Leakage Reactance n. o. Direct axis transient open circuit time constant o. p. Quadrature axis transient open circuit time constant p. q. Direct axis subtransient open circuit time constant q. r. Quadrature axis subtransient open circuit time constant r. s. Open Circuit saturation curve s. t. Reactive Capability Curve showing overexcited and underexcited limits (Reactive Information if non-synchronous) t. u. Excitation System Block Diagram with values for gains and time constants (Laplace transforms) u. v. Short Circuit Current contribution from generator at the Point of Common Coupling v. w. Rotating inertia of overall combination generator, prime mover, couplers and gear drives w. x. Station Power load when generator is off-line, Watts, pf x. y. Station Power load during start-up, Watts, pf y. z. Station Power load during operation, Watts, pf z.

Appendix B Induction Generators Generator Information a. Generator Nameplate Voltage a. b. Generator Nameplate Watts or Volt-Amperes b. c. Generator Nameplate Power Factor (pf) c. d.rpm d. Technical Information e. Synchronous Rotational Speed e. f. Rotation Speed at Rated Power f. g. Slip at Rated Power g. h. Minimum and Maximum Acceptable Terminal Voltage h. i. Motoring Power (kw) i. j. Neutral Grounding Resistor (If Applicable) j. k. I 2 2 t or K (Heating Time Constant) k. l. Rotor Resistance l. m. Stator Resistance m. n. Stator Reactance n. o. Rotor Reactance o. p. Magnetizing Reactance p. q. Short Circuit Reactance q. r. Exciting Current r. s. Temperature Rise s. t. Frame Size t. u. Design Letter u. v. Reactive Power Required in Vars (No Load) v. w. Reactive Power Required in Vars (Full Load) w. x. Short Circuit Current contribution from generator at the Point of Common Coupling x. y. Rotating inertia, H in Per Unit on kva Base, of overall combination generator, prime mover, couplers and gear drives y. z. Station Power load when generator is off-line, Watts, pf z. aa. Station Power load during start-up, Watts, pf bb. Station Power load during operation, Watts, pf aa. bb.

Appendix C Sample Site Plan

Appendix D Inverter Generators One - Line Diagram Name of the Licensed Contractor /PE Contractor Licensed Number Address Sinagture

Appendix E (Not Required for Flow-Back) One - Line Diagram Name of the Licensed Contractor /PE Contractor Licensed Number Address Sinagture

Appendix F (Not Required for Flow-Back) One - Line Diagram Name of the Licensed Contractor /PE Contractor Licensed Number Address Sinagture