Ordering Information. Short Barrel Inductive Prox E2E3-WIREDC. Short Barrel 3-Wire Prox Sensors Meet IP67

Similar documents
Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Cylindrical Proximity Sensor

Inductive Proximity Sensor E2Q2. Ordering Information. Limit Switch Style Proximity Sensor with 5-Position Sensing Head

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

TL-N7MD1 7mm(0.28 in) NC. 12 mm (0.47 in)

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Inductive Proximity Sensor

Inductive Proximity Sensor

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Inductive Proximity Sensor

E2EZ-X2D1-N E2EZ-X2D2-N

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Correction Reissue. Product Discontinuation Notices. Discontinuation Notice of Cylindrical Proximity Sensor Model E2E series.

Inductive Proximity Sensor

Inductive Proximity Sensor

Inductive Proximity Sensor

Transistor Remote Modules

Miniature Enclosed Limit Switch D4MC. Ordering Information. Economical, General-Purpose, Enclosed Switch. H High precision and long life (10,000,000

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Proximity Sensors E-1. Standard E2E/E2EG E-2 Antispatter E2EQ E-32 Chemical Resistance E2FQ E-40. Cylindrical

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

E2Q6. Rectangular Proximity Sensor. Freely Change the Sensing Direction. Ordering Information. Sensors [Refer to Dimensions on page 6] DC Models

G9SA-TH. Two-Hand Controller. Ordering Information. Specifications. 45-mm Wide Two-hand Control Circuit. H Two-hand Controller, easy-to-connect

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Sensing & Safety GENERAL CATALOGUE 2004/2005

Inductive Proximity Sensor

Multiple Plunger Limit Switch

Cylindrical type proximity sensor

E2K-L. Liquid Level Sensor. Applications. Ordering Information

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Analog Input Terminal

Differential Pressure Sensor

Digital display Pressure range ON/OFF output Linear output Model

Inductive Proximity Sensor

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

SYSMAC Transistor Remote Module

Switching Power Supply

Model Pressure range ON/OFF output Linear output

Analog Output Terminal

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

DC2-Wire Unshielded Cylindrical Proximity Switches

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Cylindrical Inductive Proximity Sensor GX-M SERIES

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

E2E/E2EQ NEXT Series. Proximity Sensor. Long-distance Detection Prevents Unexpected Facility Stoppages. E2E/E2EQ NEXT Series Model Number Legend

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

D4DS. Safety-Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. H Conforms to EN (TÜV) standards.

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Ordering Information. Application Example. New General-purpose Incremental-type. Rotary Encoder. Accessories (Order Separately)

Cylindrical Sensors CY-100 SERIES panasonic-electric-works.net/sunx. Cylindrical Inductive Proximity Sensor GX-M SERIES.

Model Pressure range ON/OFF output Linear output

Various applications. Robust housing. The GX-4S uses a robust stainless steel housing. The tightening torque can be 0.58 N m or less.

General Purpose Relay

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

Operation mode. Sensing distance N.O. N.C. N.O. N.C. N.O. N.C. 7mm

AC/DC2-wire Type Cylindrical Proximity Switches

H3DS-X - Solid State Two-Wire Timer

Type Terminal Coil Contact form Model

E2EM-X4X1 2M * E2EM-X4X2 2M Shielded E2EM-X8X1 2M * E2EM-X8X2 2M. M30 15 mm E2EM-X15C1 2M E2EM-X15C2 2M. M18 16 mm E2EM-X16MX1 2M E2EM-X16MX2 2M

General Purpose Relay

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

FL7MSeries. DC2-Wire Regular Cylindrical Proximity Sensors

Power Controller. (see note 1) 10 sec

D4D-N. Safety Limit Switch. Small, Economical Switch Featuring a Positive Opening Mechanism and CE Marking. H Contacts opened by positive opening

Compact Inductive Proximity Sensor. onlinecomponents.com. Various Applications

General Purpose Relay

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Model Number Structure

DC2-Wire Spatter-Guarded Cylindrical Proximity Switches

Switching Power Supply

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Model Number Structure

Small-diameter Proximity Sensor

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

Small Limit Switch D4V

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

A22NK. Key-type Selector Switches

Rectangular-shaped Inductive Proximity Sensor.

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Type Plunger Switch height Operating force Model Without ground terminal With ground terminal. 5.0 mm General-purpose: 100 g 150 g

Ordering Information. Text Surface-Mounting Signal Relay G6K

Cylindrical Proximity Sensor E2GN

Proximity Sensors. Reference Information. Principles of Operation. Proximity Sensors

Hinged Safety Door Switch

Transcription:

R Short Barrel Inductive Prox E2E3-WIREDC Short Barrel 3-Wire Prox Sensors Meet IP67 H Thick nickel-plated brass barrel has wrench flats for easy installation H Solid potted internal circuitry withstands shocks and water washdown to IP67 H High visibility H Miniature and standard sizes Ordering Information J PREWIRED MINIATURE SENSORS Type Size Sensing distance Output Part number configuration NO NC Shielded 4mm dia. M5 5.4 mm dia. 0.8 mm 1 mm 1 mm NPN E2E-CR8C1 E2E-CR8C2 PNP E2E-CR8B1 E2E-CR8B2 NPN E2E-X1C1 E2E-X1C2 PNP E2E-X1B1 E2E-X1B2 NPN E2E-C1C1 E2E-C1C2 PNP E2E-C1B1 E2E-C1B2 J PREWIRED SHIELDED STANDARD SENSORS Type Size Sensing distance Output Part number configuration NO NC Shielded M8 M12 M18 M30 1.5 mm NPN E2E -X1R 5E1 E2E -X1R 5E2 PNP E2E -X1R 5F1 E2E -X1R 5F2 2mm NPN E2E -X2E1 E2E -X2E2 PNP E2E -X2F1 E2E -X2F2 5mm NPN E2E -X5E1 E2E -X5E2 PNP E2E -X5F1 E2E -X5F2 10 mm NPN E2E -X10E1 E2E -X10E2 PNP E2E -X10F1 E2E -X10F2 N ot e: 1. A diff er ent os c illat ing f r equenc y is av ailable. A dd a 5 t o t he par t number ( e. g., E 2E - X 5E 15 ). 2. E 2E s ens or s w it h r obot ic c able ar e av ailable. A dd a - R in t he par t number ( e. g., E 2E - X 5E 1- R ). 2

J PREWIRED UNSHIELDED STANDARD SENSORS Type Size Sensing distance Output Part number configuration NO NC Unshielded M8 M12 M18 2 mm NPN E2E -X2ME1 E2E -X2ME2 PNP E2E -X2MF1 E2E -X2MF2 NPN E2E -X5ME1 E2E -X5ME2 5mm PNP E2E -X5MF1 E2E -X5MF2 10 mm NPN E2E -X10ME1 E2E -X10ME2 PNP E2E -X10MF1 E2E -X10MF2 M30 NPN E2E -X18ME1 E2E -X18ME2 18 mm PNP E2E -X18MF1 E2E -X18MF2 N ot e: 1. A diff er ent os c illat ing f r equenc y is av ailable. A dd a 5 t o t he par t number ( e. g., E 2E - X 5E 15 ). 2. E 2E s ens or s w it h r obot ic c able ar e av ailable. A dd a - R in t he par t number ( e. g., E 2E - X 5E 1- R ). J SENSORS WITH BUILT-IN M12 MICROCHANGE R CONNECTOR Type Size Sensing distance Output Part number configuration NO NC Shielded Unshielded M8 M12 M18 M30 M8 M12 M18 1.5 mm NPN E2E -X1R 5E1 -M1 E2E -X1R 5E2 -M1 PNP E2E -X1R 5F1 -M1 E2E -X1R 5F2 -M1 NPN E2E -X2E1 -M1 E2E -X2E2 -M1 2mm PNP E2E -X2F1 -M1 E2E -X2F2 -M1 5mm NPN E2E -X5E1 -M1 E2E -X5E2 -M1 PNP E2E -X5F1 -M1 E2E -X5F2 -M1 10 mm NPN E2E -X10E1 -M1 E2E -X10E2 -M1 PNP E2E -X10F1 -M1 E2E -X10F2 -M1 NPN E2E -X2ME1 -M1 E2E -X2ME2 -M1 2mm PNP E2E -X2MF1 -M1 E2E -X2MF2 -M1 NPN E2E -X5ME1 -M1 E2E -X5ME2 -M1 5mm PNP E2E -X5MF1 -M1 E2E -X5MF2 -M1 10 mm NPN E2E -X10ME1 -M1 E2E -X10ME2 -M1 PNP E2E -X10MF1 -M1 E2E -X10MF2 -M1 M30 NPN E2E -X18ME1 -M1 E2E -X18ME2 -M1 18 mm PNP E2E -X18MF1 -M1 E2E -X18MF2 -M1 Connector cordsets: For MicroChange R models, use OMRON Y96E-4jDj. J SENSORS WITH BUILT-IN M8 NANOCHANGE R CONNECTOR Type Size Sensing distance Output Part number configuration NO NC Shielded M8 1.5 mm NPN E2E-X1R5E1-M3 E2E-X1R5E2-M3 PNP E2E-X1R5F1-M3 E2E-X1R5F2-M3 Unshielded M8 2mm NPN E2E-X2ME1-M3 E2E-X2ME2-M3 PNP E2E-X2MF1-M3 E2E-X2MF2-M3 Connector cordsets: For NanoChange R models, use OMRON X3SF-M42j-40j-R or Brad Harrison equivalent. 3

J ACCESSORIES Description Part number Mounting brackets Fits M8 size sensors Y92E-B8 Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors Y92E-B12 Y92E-B18 Y92E-B30 Silicone rubber covers for shielded sensors Fits M12 size sensors Y92E-E12-2 Fits M18 size sensors Fits M30 size sensors Y92E-E18-2 Y92E-E30-2 J REPLACEMENT PARTS Description Part number Mounting hardware including one pair of Fits M5 size sensors M5-MHWS metal nuts and one washer Fits M8 size sensors M8-MHWS Fits M12 size sensors Fits M18 size sensors Fits M30 size sensors M12-MHWS M18-MHWS M30-MHWS 4

Specifications J MINIATURE SENSORS Part number E2E-CR8jj E2E-X1jj E2E-C1jj Size 4 mm (0.16 in) dia. M5 5.5 mm (0.21 in) dia. Type Shielded Sensing distance 0.8 mm (0.03 in) ± 15% 1 mm (0.04 in) ± 15% Supply voltage 10 to 30 VDC, 10% max. permissible ripple peak to peak Current consumption 17 ma max. Sensing object Magnetic metals Setting distance 0to0.5mm(0to0.02in) 0to7mm(0to0.03in) Standard object 5x5x1mm(0.2x0.2x0.04in) 8x8x1mm(0.3x0.3x0.04in) (mildsteel,lxwxh) Differential travel 15% max. of effective distance Response frequency 3kHz Control output Operation C1 models: NPN-NO open collector C2 models: NPN-NC open collector B1 models: PNP-NO open collector B1 models: PNP-NC open collector Max. load 100 ma switching capacity Max. on-state voltage drop 2VDC Circuit protection DC power supply reverse polarity Indicators (red LED) Ambient temperature Operating - 25 C to70 C (-13 F to 158 F) with no icing Ambient humidity Operating 35% to 95% Vibration resistance 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude Shock resistance Approx. 50 G s Enclosure UL rating NEMA 1, 3, 4, 6, 12, 13 IEC 144 IP67 Weight with cable Approx. 30 g (1.1 oz.) Materials Housing Stainless steel Nickel-plated brass Nickel-plated brass Sensing Plastic PBT face Cable sheath Polyvinyl chloride 5

J STANDARD SIZE SENSORS Part number E2E-X1R5 Ej/Fj E2E-X2ME j/ Fj E2E-X2Ej /Fj E2E-X5ME j/fj E2E-X5Ej /Fj E2E-X10M Ej/Fj E2E-X10E j/ Fj E2E-X18M Ej/ Fj Size M8 M12 M18 M30 Type Shielded Unshielded Shielded Unshielded Shielded Unshielded Shielded Unshielded Sensing distance 1.5 mm (0.06 in) ±10% 2 mm (0.08 in) ±10% 2 mm (0.08 in) ±10% 5 mm (0.20 in) ±10% 5 mm (0.20 in) ±10% 10 mm (0.39 in) ±10% 10 mm (0.39 in) ±10% 18 mm (0.71 in) ±10% Supply voltage 12 to 24 VDC, ripple (p-p): 10% max., (10 to 40 VDC) (operating voltage range) (See Note 1.) Current consumption 13 ma max. Sensing object Magnetic metals (refer to Engineering Data for non-magnetic metals) Setting distance Standard object (mild steel) 0to1.2 mm (0 to 0.05 in) 8x8x 1 mm (0.31 x0.31x 0.04 in) 0to1.6 mm (0 to 0.06 in) 12 x 12 x 1mm (0.47 x 0.47 x0.04in) 0to1.6mm (0 to 0.06 in) 12 x 12 x 1mm (0.47 x 0.47 x0.04in) 0to4.0mm (0 to 0.16 in) 15 x 15 x 1mm (0.59 x 0.59 x0.04in) 0to4.0mm (0 to 0.16 in) 18 x 18 x 1mm (0.71 x 0.71 x0.04in) 0to8.0mm (0 to 0.31 in) 30 x 30 x 1mm (1.18 x 1.18 x0.04in) 0to8.0mm (0 to 0.31 in) 30 x 30 x 1mm (1.18 x 1.18 x0.04in) 0to14.0 mm (0 to 0.55 in) 54 x 54 x 1mm (2.13 x 2.13 x0.04in) Differential travel 10% max. of sensing distance Response frequency 2.0 khz 0.8 khz 1.5 khz 0.4 khz 0.6 khz 0.2 khz 0.4 khz 0.1 khz Operation (with sensing object approaching) Control output (switching capacity) Circuit protection Indicator Ambient temperature (See Note 2.) E1 models: ON E2 models: OFF 200 ma max. Ambient humidity Operating: 35% to 95% Temperature influence Reverse connection protection, surge absorber, load short-circuit protection (red LED) Operating: -40 C to85 C (-40 F to 185 F) with no icing ±15% max. of sensing distance at 23 C in temperature range of -40 C to85 C (-40 F to 185 F) ±10% max. of sensing distance at 23 C in temperature range of -25 C to70 C (-13 F to 158 F) Voltage influence ±1% max. of sensing distance in rated voltage range ±15% Residual voltage 2.0 V max. (under load current of 200 ma with cable length of 2 m) Insulation resistance 50 MΩ min. (at 500 VDC) between current carry parts and case Dielectric strength 1,000 VAC for 1 min. between current carry parts and case Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z axes Shock resistance 500 m/s 2 (approx. 50G) for10timeseachinx,y, and Z axes Enclosure IEC IP67 rating NEMA 1, 4, 6, 12, 13 1,000 m/s 2 (approx. 50G) for 10 times each in X, Y, and Z axes 500 m/s 2 (approx. 50G) for E2E-X5M Weight Pre-wired Approx. 45 g Approx. 120 g Approx. 160 g Approx. 270 g Connector --- Approx. 25 g Approx. 45 g Approx. 125 g Material Body Stainless steel Sensing PBT face Approx. 124 g 1. E2E models with an M18 or M30 connector operate at a non-smoothed, all-wave rectified, mean voltage range of 24 VDC ±20%. 2. When using an E2E with an M8 connector at an ambient temperature range between 70 C and 85 C (158 F and 185 F), supply 10 to 30 VDC to the E2E and make sure that the E2E has a control output of 100 ma maximum. 6

Operation J OUTPUT CIRCUITS Miniature Models E2E-C/XjCj NPN Output 100Ω Brown E2E-C/XjBj PNP Output Brown Main Circuit Black Output Blue Main Circuit 100Ω Black Output Blue *100 ma max. (sink current) 2 V max. (residual voltage) *100 ma max. (source current) 2 V max. (residual voltage) Target Present Absent E2E-C(X)jC1 NO Present Absent E2E-C(X)jC2 NC Target Present Absent E2E-C(X)jB1 NO Present Absent E2E-C(X)jB2 NC (between brown and black) Operates Releases Operates Releases (between black and blue) Operates Releases Operates Releases (LED) ON OFF ON OFF (LED) ON OFF ON OFF Standard Size Models E2E -Xj E j E2E -Xj F j NPN Output PNP Output Brown Brown +V +V 1.5to3mA Black Black Blue 0V 1.5to3mA Blue 0V Sensing object Red Control output Output voltage Yes No Lit Not lit ON OFF H L Sensing object Red Control output Yes No Lit Not lit ON OFF 7

Engineering Data J OPERATING RANGE (TYPICAL) Shielded Models E2E-CR8jj, E2E-X1jj, E2E-C1jj Sensing distance X [mm (inch)] 1.0 0.4 Operating distance X [mm] E2E-X1/E2E-C1 E2E-CR8 E2E -Xj E j /F j Sensing distance X (mm) E2Ej-X2j E2Ej-X1R5j Sensing distance X (mm) E2Ej - X10j E2Ej - X5j 0.2-3.0-2.0-1.0 0 1.0 2.0 3.0 Y (mm) Y (mm) Shielded Models E2E -Xj ME j /F j Sensing distance X (mm) E2Ej-X5Mj Sensing distance X (mm) E2Ej-X18Mj E2Ej-X2Mj E2Ej-X10Mj Y (mm) Y (mm) J SENSING DISTANCE VS. SENSING OBJECT (TYPICAL) E2E -CR8 jj E2E -X1 jj, E 2 E -C 1 jj E2E -X1R5Ej /F j Mild steel Stainless steel Copper Mild steel Stainless steel Mild steel Stainless steel 8

E2E -X2Ej/Fj E2E -X5Ej/Fj E2E -X10EjFj Mild steel Mild steel Stainless steel Mild steel Stainless steel Stainless steel E2E -X2MEj/Fj E2E -X5MEj/Fj E2E -X10MEj/Fj Mild steel Mild steel Stainless steel Copper Mild steel Stainless steel Stainless steel E2E -X18MEj/Fj E2E -X18MYj Mild steel Stainless steel 9

Dimensions J DRAWING LOCATOR Type Part number Figure number Prewired Shielded 4mmdia. E2E-CR8j 1 M5 E2E-X1j 2 5.4 mm dia. E2E-C1j 3 M8 E2E-X1R 5Ej/Fj 4 M12 E2E-X2Ej/Fj 6 M18 E2E-X5Ej/Fj 8 M30 E2E-X10Ej/Fj 10 Prewired Unshielded M8 E2E-X2MEj/Fj 5 M12 E2E-X5MEj/Fj 7 M18 E2E-X10MEj/Fj 9 M30 E2E-X18MEj/Fj 11 4-pin Shielded M8 E2E-XR 5MEj-M1/Fj-M1 12 connector M12 E2E-X2MEj-M1/Fj-M1 14 (M12) M18 E2E-X5MEj-M1/Fj-M1 16 M30 E2E-X10MEj-M1/Fj-M1 18 Unshielded M8 E2E-X2MEj-M1/Fj-M1 13 M12 E2E0-X5MEj-M1/Fj-M1 15 M18 E2E-X10MEj-M1/Fj-M1 17 M30 E2E-X18MEj-M1/Fj-M1 19 M8 connector Shielded M8 E2E-X1R 5Ej-M3/jF- M3 20 Unshielded E2E-X2MEj-M3/jF- M3 21 Unit: mm (inch) J SENSORS Miniature Shielded DC Types Fig. 1: E2E-CR8C(B)j Fig. 2: E2E-X1C(B)j Fig. 3: E2E-C1C(B)j 10

Prewired Models (Shielded) Prewired Models (Unshielded) Fig. 4: 15 dia. (0.59) E2E -X1R 5Ej/Fj 30 (1.18) 26 (1.02) Fig. 5: 15 dia. (0.59) 6 (0.24) E2E -X2MEj/Fj 30 (1.18) 26 (1.02) Operation M8 x 1 Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia. x 6/10) for robotics cable models Standard length: 2 m 6.1 dia. M8 x 1 Operation Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia. x 6/10) for robotics cable models Standard length: 2 m Fig. 6: E2E -X2Ej/Fj Fig.7: E2E -X5MEj/Fj 21 dia. (0.83) 38 (1.50) 33 (1.30) 21 dia. (0.83) 7 (0.28) 38 (1.50) 33 (1.30) Operation Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia. x 6/10) for robotics cable models Standard length: 2 m 9dia. Operation Two clamping nut Round vinyl-insulated cable 4 dia. (0.08 dia. x 60), 2/3 cores 4 dia. (0.08 dia. x 6/10) for robotics cable models Standard length: 2 m Fig. 8: E2E -X5Ej/Fj F i g. 9: E 2E -X 10ME j/fj 29 dia. (1.14) 43 (1.69) 38 (1.50) 29 dia. (1.14) 10 (0.39) 43 (1.69) 38 (1.50) Operation M18 x 1 Round vinyl-insulated Cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2 m 14.8 dia. M18 x 1 Operation Round vinyl-insulated Cable 6 dia. (0.12 dia. x45),2/3cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2 m F i g. 10: E 2E -X j/fj 10E F i g. 11: E 2E -X 18ME j/fj 42 dia. (1.65) 48 (1.89) 43 (1.69) 42 dia. (1.65) 48 (1.89) 43 (1.69) 13 (0.51) M30 x 1.5 Round vinyl-insulated Cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2 m 26.8 dia. M30 x 1.5 Operation Two clamping nut Round vinyl-insulated Cable 6 dia. (0.12 dia. x 45), 2/3 cores 6 dia. (0.08 dia. x 6/17) robotics cable models Standard length: 2 m 11

Connector Models (Shielded) Connector Models (Unshielded) Fig. 12: E2E -X1R 5Ej -M 1 / j F -M1 Fig. 13: E2E -X2ME j -M 1 / F j -M 1 15 dia. (0.59) 43 (1.69) 30 (1.18) 26 (1.02) 15 dia. (0.59) 43 (1.69) 30 (1.18) 26 (1.02) 6 (0.24) M8 x 1 6.1 dia. M8 x 1 Fig. 14: E2E -X2Ej -M 1 / j F -M1 Fig. 15: E2E -X5ME j -M 1 / F j -M 1 21 dia. (0.83) 48 (1.89) 21 dia. (0.83) 48 (1.89) 33 (1.30) 33 (1.30) 7 (0.28) 9dia. Fig. 16: E2E -X5Ej -M 1 / j F -M1 F i g. 17: E 2E -X 10ME j -M 1 / F j -M 1 29 dia. (1.14) 53 (2.09) 38 (1.50) 29 dia. (1.14) 10 (0.39) 53 (2.09) 38 (1.50 ) M18 x 1 14.8 dia. M18 x 1 F i g. 18: E 2E -X j 10E -M 1 / j F -M1 F i g. 19: E 2E -X 18ME j -M 1 / F j -M 1 42 dia. (1.65) 58 (2.28) 43 (1.69) 42 dia. (1.65) 58 (2.28) 43 (1.69) 13 (0.51) M30 x 1.5 26.8 dia. M30 x 1.5 12

M8 Connector Models (Shielded) M8 Connector Models (Unshielded) Fig. 20: E2E -X1R 5Ej -M 3 / j F -M 3 Fig. 21: E2E -X2MEj -M 3 / j F -M 3 15 dia. (0.59) 39 (1.54) 31 (1.22) 26 (1.02) M8 x 1 15 dia. (0.59) 6 (0.24) 39 (1.54) 31 (1.22) 26 (1.02) M8 x 1 M8 x 1 6.1 dia. M8 x 1 Mounting Holes F Dimensions 4dia. M5 5.4 dia. M8 M12 M18 M30 F (mm) 4.2 +0.5 / 0 dia. 5.5 +0.5 / 0 dia. 5.7 +0.5 / 0 dia. 8.5 +0.5 / 0 dia. 12.5 +0.5 / 0 dia. 18.5 +0.5 / 0 dia. 30.5 +0.5 / 0 dia. Connection J PIN ARRANGEMENT E2E-XjEj-M1 Connector Output configuration Applicable models Pin arrangement M12 Micro NO E2E-XjE1-M1 ChangeR Terminal 2 is not used. E2E-XjF1- M1 Terminal 2 is not used. NC E2E-XjE2-M1 Terminal 4 is not used. E2E-XjF2- M1 Terminal 4 is not used. (This table continues on the next page.) 13

Connector Output configuration Applicable models Pin arrangement M8 Nano NO E2E-XjE1-M3 ChangeR Terminal 2 is not used. E2E-XjF1- M3 Terminal 2 is not used. NC E2E-XjE2-M3 Terminal 4 is not used. E2E-XjF2- M3 Terminal 4 is not used. Installation J MOUNTING Do not tighten the nut with excessive force. A washer must be used with the nut. Shielded Model Unshielded Model Type Part A Part B Length Torque Torque M5 1NS m(10kgfs cm) M8 Shielded 9mm 9NS m 12 N S m Unshielded 3mm (90 kgf S cm) (120 kgf S cm) M12 30 N S m (310 kgf S cm) M18 70 N S m (710 kgf S cm) M30 180 N S m (1,800 kgf S cm) Refer to the following to mount the E2E-CR8 and E2E-C1 nonscrew models. Part B Part A Part B Part A 8to21mm M3 hole The table above right shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. No screw is provided with the E2E-CR8 or E2E-C1. Tighten the screw to a torque of 0.20 N S m(2kgfs cm) maximum to secure the E2E-CR8 and a torque of 0.39 N S m(4kgfs cm) maximum to secure the E2E-C1. 14

J EFFECTS OF SURROUNDING METAL When mounting the E2E within a metal panel, ensure that the clearances given in the following table are maintained. Failure to maintain these distances may cause deterioration in the performance of the sensor. ddia. Type Dimension 4mmdia. M5 5.4 mm M8 M12 M18 M30 dia. E2ECR8jj Shielded l 0mm 0mm 0mm 0mm 0mm 0mm 0mm E2E-X1j d 4mm 5mm 5.4 mm 8mm 12 mm 18 mm 30 mm E2E-C1j D 0mm 0mm 0mm 0mm 0mm 0mm 0mm E2E-XjEj E2E-XjFj m 2.9 mm 3mm 3mm 4.5 mm 8mm 20 mm 40 mm DC 3-wire n 6mm 8mm 8mm 12 mm 18 mm 27 mm 45 mm Unshielded l 6mm 15 mm 22 mm 30 mm d 24 mm 40 mm 55 mm 90 mm D 6mm 15 mm 22 mm 30 mm m 8mm 20 mm 40 mm 70 mm n 24 mm 36 mm 54 mm 90 mm J MUTUAL INTERFERENCE When installing two or more Sensors face to face or side by side, ensure that the minimum distances given in the following table are maintained. A B Type Dimension 4mm dia. E2ECR8j E2E-X1j E2E-C1jj E2E-XjEj E2E-XjFj M5 5.4 mm dia. M8 M12 M18 M30 Shielded A 20 mm 20 mm 20 mm 20 mm 30 (20) mm 50 (30) mm 100 (50) mm B 15 mm 15 mm 15 mm 15 mm 20 (12) mm 35 (18) mm 70 (35) mm Unshielded A 80 mm 120 (60) mm 200 (100) mm 300 (100) mm DC 3-wire B 60 mm 100 (50) mm 110 (60) mm 200 (100) mm The figures in parentheses refer to Sensors operating at different frequencies. 15

Precautions J INSTALLATION Power Reset Time The Proximity Sensor is ready to operate within 100 ms after power is supplied. If power supplies are connected to the Proximity Sensor and load respectively, be sure to supply power to the Proximity Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned off. You must turn off the load before turning off the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Object Metal Coating The sensing distances of the Proximity Sensor vary with the metal coating on sensing objects. J WIRING High-tension Lines Wiring through Metal Conduit If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Tractive Force Do not pull cable with the tractive forces exceeding the following. Diameter Tractive force 4mmdia.max. 30 N max. 4 mm dia. min. 50 N max. J MOUNTING The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, or the Proximity Sensor may be damaged or lose its water-resistance. J ENVIRONMENT Water Resistance Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistant, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). 16

NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON OMRON ON -LINE Global -- http://www.omron.com USA -- http://www.omron.com/oei Canada -- http://www.omron.com/oci OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Cat. No. CEDSAX4 11/01 Specifications subject to change without notice. Printed in U.S.A.