Installation Instructions: HYPERION R-Lite SYSTEM

Similar documents
Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

SloanLED THINLED. Constant Current. Installation Guide

WARNING. Tools: 1. Wire Strippers 2. Screw Driver or Rivet Gun 3. Tape Measure 4. Drill. Components: AWG (0.82mm) Wire-UL Approved

PDX and PX Retrofit Series

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Assembly Instructions Retrofitting

LM79 LM80 L70:5+ YEARS

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

LumaFilm Light Emitter Installation Instructions

G2.1 RETROFIT LED LIGHTING

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps


Installation Instructions: Eco Linear High Bay

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

The Gallery System DIRECTIONS. Components of the System

Chapter 8 Interior Wiring and Lighting

Generator Fire Safety: Generator assemblies should be located outside the building.

LED LINEAR INSTALLATION GUIDE RED 20L VER /13/

VITALink Taped Splice Pigtail Crimp

2 4 L R I G I D L E D L E D S I M U L AT E D N E O N I N S TA L L AT I O N G U I D E MANUAL FOR 48 SYSTEM ADVANCE POWER SUPPLY ONLY!

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Technical Installation Manual

LED LINEAR AMBER 20L INSTALLATION GUIDE /01/16 VER. 1.0 CERTIFIED SAFETY US CA

ThermoLite 40W Solar Panel Installation Instructions

ONE TOUCH CONTROL BOX

INSTALLATION INSTRUCTIONS TRAILER HITCH MAIN HARNESS KIT

Optimax Pro Retrofit Instructions

BUICK SKYLARK & GS CHEVROLET CHEVELLE & MONTE CARLO PONTIAC GTO & LEMANS OLDSMOBILE CUTLASS & 442

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

Universal Retrofit System Installation Instructions Revised:

* * APPLICABLE MODELS: 2014 > Mazda 3

GENUINE PARTS INSTALLATION INSTRUCTIONS

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

RibbonFlex Pro LED Accent Lighting White LED Tape Light. Welcome to RibbonFlex Pro LED Tape Lighting. Notes:

Electric Vehicle Charging Station

LED Recessed Troffer Retrofit Kit

SECTION 300 OVERHEAD SERVICE

LightRider. Instructions for Power Link Helmet Light. Helmet Vertical Midline

METERING REQUIREMENTS

Installation Instructions: Read these instructions in its entirety before performing any installation work.

* * APPLICABLE MODELS: 2014 > Mazda 6

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

10 Commercial, Industrial, Agricultural Services

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

SLIMFLEX LED Tape Lighting

Installation Guide The RSi brief overview:

* * APPLICABLE MODELS: 2017 > CX-5

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

* * APPLICABLE MODELS: 2016 > CX-3

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

COOLEDGE TILE EXTERIOR INSTALLATION INSTRUCTIONS FIT-2. Caution: Observe precautions for handling electrostatic sensitive devices.

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions Studio Makeup Station

SCION xd INTERIOR LIGHTING UPGRADE Preparation

STREET WRAP INSTALLATION GUIDE

6500DC Dual Motor Wireless Controller Kits

Do not work on the system or connect or disconnect cables during periods of lightning activity. Statement 1001

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

THE SERIES-E POWR Slider

Installation Instructions: Read these instructions in its entirety before performing any installation work.

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Lumination TM LED Luminaire LUR Series

GVW AGM Auxiliary Battery Kit for Air-cooled Westfalia Campers and all Vanagon NON-campers

RapidLED NanoCube 24 Aurora Array Retrofit

ThermoLite 110W-330W Solar Panel Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

T-52. r ve Pickup Lift Mounting Instructions Chevy / GMC- Colorado/ Canyon: 2015-present. Preparing the Gate. Installing the Bolt-on Gussets

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Installation and Service Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Ag Leader Technology. Combine Installation New Holland TC 57, 59. Monitor Installation

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS. ITEM QTY DESCRIPTION Usage Chart Service Part Number. 1 1 Mirror Assembly w/ Compass 1

channel damage the internal components and the weight may break the internal wiring or flexible strip.

Parts and Accessories Installation Instructions

A.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

M-150S Series 12-Volt Fuel Pump M-150S-B100-MU Manual Nozzle & M-150S-B100-AU Automatic Nozzle Owner s Manual

BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Illuminator System Series CM

Model LA 4400 Time Delay OFF Controller

Pole Mount COD Installations (PMCOD)

Toyota 4RUNNER With/MR Overhead Video

GENUINE PARTS INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS

TSRT TSRT Tee Splice Kit Installation Instructions

Stik Families GENERAL PURPOSE RETROFIT SIGN CONVERSION FOR USE ONLY IN ACCORDANCE WITH KIT INSTRUCTIONS

Model LA 4100 Time Delay OFF Controller

SAVE THESE INSTRUCTIONS!!

Installation, Maintenance, and Operation Manual

Installation Manual. CS9300 Professional Series Landscape Lighting System

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

INSTALLATION GUIDE AND USER MANUAL

Transcription:

Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire installation manual. The 12-ft rule: keep the runs to 12-ft or under. Properly clean and prep the surface area that the strip will be applied to. For Secondary Low Voltage Wiring use 10AWG or 12AWG Class 2 rated wire only. Using higher than 12AWG wire will result in increased voltage drop. Do not use wire nut connectors for connecting power connectors to secondary low voltage wiring. Use wire nuts to insulate only the ends of the low voltage wires. RETROFITTING OF UL LISTED SIGNS E230263 / 7BA6 E230262 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 1 of 14

The main power to any existing system must be disconnected prior to the installation. The Accent system is intended to be used for new lighting systems or as a retrofit for existing neon, fluorescent or any combination thereof. When installing retrofit systems please refer to the existing products manufacturer for proper removal guidelines. All existing system components must be removed before installation of the Accent system. All removed material must be properly disposed of to meet your federal, state and local regulations. Install in accordance with the NEC and Local Electrical Codes. The Retrofit Kit System is to be installed in Listed Signs only. Hardware Screws IDC connectors Wire nuts Class 2 low voltage wire Tools Scissors Drill Screwdriver Pliers Optional Support Clamps Silicone For Retrofitting When installing retrofit systems please refer to the existing products manufacturer for proper removal guidelines. All existing system components must be removed before installation of the HYPERION R-Lite system. All removed material must be properly disposed of to meet your federal, state and local regulations. Note: After retrofitting is completed, all unused holes and openings must be sealed. Openings greater than 1/2 inch in diameter require a metal patch secured by screws and caulked with non-hardening caulk. Smaller openings can be sealed with non-hardening caulk. SURFACE PREPARATION Surface must be free of dust, dirt, grease, sharp objects, openings or corroded surfaces or other foreign material. Use non-oil based solvent (409, alcohol or heptane) to clean the surface. Area must be dry before application. HYPERION R-Lite strip bonds to all non-porous surfaces. Note: Application temperature range: 32 F to 100 F (0 C to 38 C). Note: If painting is necessary the paint must be dry before installation of strip. Note: Do not place the strip over sharp or non-flat objects or over patched holes. Note: It is recommended to test one or more letters before installation for acceptable color and illumination. REQUIRED FOR ALL FIELD RETROFITS To ensure adhesion of the HYPERION R-LITE strip to the back of the channel letter / cabinet place a plastic support clamp across the LED strip every 4 inches to mechanically secure the strip to the channel letter or cabinet. ( Att. 2) Note: Application temperature range: 32 F to 100 F (0 C to 38 C). Note: Do not place the strip over sharp or non-flat objects or over patched holes. Note: Do not drive the screw through the strip. Note: Do not put the clamp over any bends in the strip. ( Att. 2) Note: It is required that you utilize support clamps and/or a bead of silicone adhesive across the top of LED strip every 4 inches. (Continue to New Install) Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 2 of 14

New Install 1. Surface must be free of dust, dirt and grease. Use non-oil based solvent (409, alcohol) to clean the surface. Area must be dry before application. The HYPERION R-Lite strip bonds to all non-porous surfaces. Note: Application temperature range: 32 F to 100 F (0 C to 38 C). Note: It is recommended to test one or more areas before installation for acceptable color and illumination. 2. Determine the linear footage required for each letter. Do not precut LED strips. Note: Always work from the R-Lite reel to avoid shortages and unnecessary use of jumpers. Note: In most cases, needed linear footage of HYPERION R-Lite strip is equal to neon. For white illumination, linear footage must be determined on a case to case basis to satisfy customer requirements. 3. Expose approximately 6 inches of the adhesive backing. Note: Do not touch adhesive tape with greasy or wet hands! 4. Adhere the HYPERION R-Lite strip inch by inch to the back surface of the channel letter. Note: Remember to place HYPERION R-Lite strip in the center of the channel letter. 5. To make a curve, bend the HYPERION R-Lite flexible conductor strip between the sockets pinching excess strip together between thumb and forefinger. After pinching adhere corner of the turn by firmly pushing down with your forefinger. Note: Do not put support clamps over any bends in the strip. 6. To trim HYPERION R-Lite strip to desired length, cut strip with scissors directly between sockets. Note: Do not make cuts near any socket. Do not use wire cutters or utility knives to trim the strip. Doing so may cause permanent damage to the strip Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 3 of 14

Installing Power Connector 1. a) Unplug the LED module from the socket. To remove the LED module, place thumb and forefinger on side edges of LED module and pull directly upwards until LED module is released from the socket. b) With thumb and forefinger at base of the connector and aligned parallel with the strip, place connector pins into socket and lightly push down on top of connector with forefinger until the connection is secure. c) Plug in previously unplugged LED module to the top of the power connector. Note: Do not tug on connector leads. d) Secure the connector with the connector holder and secure the connector cable with a 1/4 wire clamp. ( Att.1) 2. Drill a 1/4 (6.4 mm) hole into letter or raceway for connection wire access. Hole for connector wire should be off center and to the middle of the channel letter. Place protective rubber grommet on hole. Note: Do not drill through LED strip. Note for Halo-Lit applications: A UL-recognized clear acrylic or polycarbonate should be mounted on back of channel letter. Note: Maximum run length for each power connector is 12 linear feet. Installing Jumper Connector Some letters such as E, A or H require multiple strips of HYPERION R-Lite. In cases like this use single jumper connector to connect two separate runs as shown in picture below. Connect the jumper in the best possible area trying to avoid tight areas or severe bending or stretching of jumper. Please plan ahead when using multiple jumper connectors during installation. Note: Each jumper counts as 1-ft of LED strip and must be factored into the total footage of the power supply. 1. Attach one end of the jumper anywhere on the LED strip and secure with connector holder. 2. Attach the other end of the jumper to separate LED strip and secure with connector holder. Secure all wires with a 1/4 selfadhesive clamp. ( Att.1) Note: The joined LED runs MUST NOT exceed a combined total of 11 feet. Note: Only one jumper connector can be used per power connector. Using more than one jumper connector per power connector will result in voltage drop. Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 4 of 14

Attachment 1 Attachment 2 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 5 of 14

HRL-07-PFC-24 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC 725.61 Cable Substitution Hierarchy. 1. Group letters into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines. ( Table 1) 2. Place the power unit in the middle of the selected load group as shown in the schematic drawing in attachment 3. Run a pair of Class 2 rated wires the length of the selected load group. ( Att.3) Note: Power supplies should be located within 25-ft of LED strip. Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. Note: For wet locations, HRL-07-PFC-24 power unit must be installed in NEMA 3R enclosure or inside of the electric sign. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Note: For dry or damp locations, HRL-07-PFC-24 power unit must be installed in NEMA 1 rated enclosure OR inside of all metallic enclosure, raceway OR a self-contained channel letter. 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! Note: Do not connect power supply outputs in series or parallel! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires inside the raceway/wireway or on the wall with wire clamps. 5. Connect secondary/output wires from the HRL-07-PFC-24 power unit to Class 2 rated wires by using tap and run IDC connectors. ( Att.3) Important: Maximum load is 15 linear feet per power unit. 6. Secure power unit inside of electrical enclosure, channel letter or raceway. Note: Power unit should be secured at least 2 inches from the bottom of the raceway. Note: For wet locations, HRL-07-PFC-24 power unit must be installed in NEMA 3R enclosure or inside of the electric sign. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Note: For dry or damp locations, HRL-07-PFC-24 power unit must be installed in NEMA 1 rated enclosure OR inside of all metallic enclosure, raceway OR as self-contained channel letter. Caution: Have a licensed electrician connect primary. Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 6 of 14

7. Connect the power unit to 120VAC junction box. Note: It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC). 8. Verify if disconnect switch is present. National Electrical Code (NEC) requires disconnect switch with all electrical signs. If disconnect switch is not present, it must be installed between main breaker and first power unit. Power Supplies will be used in listed signs only. Table 1: Power Supply Loading Guidelines HRL-07-PFC-24 Power Supply Outputs Output Voltage Minimum Linear Footage Maximum Linear Footage HRL-07-PFC-24 1 8.0VAC nom. No minimum 15 linear feet Attachment 3 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 7 of 14

HRL-PSSQ-25 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC 725.61 Cable Substitution Hierarchy. 1. Group letters into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines. ( Table 2) 2. Place the power unit in the middle of the selected load group as shown in the schematic drawing in attachment 3. Run a pair of Class 2 rated wires the length of the selected load group. ( Att.4) Note: Power supplies should be located within 25-ft of LED strip. Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. Note: For wet locations, HRL-PSSQ-25 power unit must be installed in NEMA 3R enclosure or inside of the electric sign. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! Note: Do not connect power supply outputs in series or parallel! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires inside the raceway/wireway or on the wall with wire clamps. 5. Connect secondary/output wires from the HRL-PSSQ-25 power unit to Class 2 rated wires by using tap and run IDC connectors. ( Att.4) Important: Minimum load per power unit is 5 linear ft. maximum load 25 linear ft. 6. Secure power unit inside of electrical enclosure, channel letter or on the wall with three screws. Note: Power unit should be secured at least 2 inches from the bottom of the raceway / channel letter. Note: For wet locations, HRL-PSSQ-25 power unit must be installed in NEMA 3R enclosure or inside of the electric sign. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 8 of 14

7. Connect the power unit to 120VAC junction box. Note: HRL-PSSQ-25 is equipped to accept 120VAC, 230VAC OR 240VAC. ( see Att.5 for wiring diagram) Caution: Have a licensed electrician connect primary. Proper connection is as follows: a) For 120VAC: Hot to Black & Yellow; Neutral/Common to Orange & White; DO NOT Connect BROWN and insulate end separately; Green: Ground b) For 230VAC: Hot to BROWN ; Neutral/Common to Orange; White & Yellow connected and insulate ends; DO NOT Connect BLACK and insulate end separately; Green: Ground c) For 240VAC: Hot to BLACK; Neutral/Common to Orange; White & Yellow connected and insulate ends; DO NOT Connect BROWN and insulate end separately; Green: Ground Note: HRL-PSSQ-25 power unit has a cutout for 1/2 conduit fitting. It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC) 8. Verify if disconnect switch is present. National Electrical Code (NEC) requires disconnect switch with all electrical signs. If disconnect switch is not present, it must be installed between main breaker and first power unit. Table 2: HRL-PSSQ-25 Power Supply Loading Guidelines Power Supply Outputs Output Voltage Minimum Linear Footage Maximum Linear Footage HRL-PSSQ-25 1 8.0VAC nom. 5 linear feet 25 linear feet Attachment 4 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 9 of 14

Attachment 5 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 10 of 14

HRL-PS96-70 Power Supply Installation All secondary wiring must comply with Article 725 of the 2002 National Electrical Code (NEC). Class 3 or PLTC wire can be used as a substitution of Class 2 wire. Please refer to NEC 725.61 Cable Substitution Hierarchy. 1. Group letters into equal load groups not to exceed the maximum load as listed in the Power Supply Loading Guidelines. ( Table 3) 2. Place the power unit in the middle of the selected load group as shown in the schematic drawing in attachment 6. Run a pair of Class 2 rated wires the length of the selected load group. ( Att.6) Note: Power supplies should be located within 25-ft of LED strip. Longer runs of 12AWG secondary wiring will decrease maximum allowable linear footage. Note: Using higher than 12AWG wire will result in increased voltage drop. 3. Connect power connector leads to Class 2 rated wires (parallel electrical connection) by using tap and run IDC connectors. Note: Do not use wire nuts for connecting power connectors to Class 2 rated wires! Note: Do not connect power supply outputs in series or parallel! 4. Use wire nuts to insulate ONLY the ENDS of the Class 2 wires. Secure Class 2 rated wires inside the raceway/wireway or on the wall with wire clamps. 5. Connect secondary/output wires to power unit terminals 1 and 2. ( Att.6 ) Note: For better power distribution divide load between terminals 1 and 2. Important: Each terminal must be balanced within 10 linear feet of each other. Important: Minimum load per terminal is 10 linear ft., maximum load is 35 linear ft. 6. Secure power unit inside of the raceway or on the wall with four screws. Note: Power unit should be secured at least 2 inches from the bottom of the raceway. Note: For wet locations, HRL-PS96-70 power unit must be installed in NEMA 3R enclosure or inside of the electric sign. Exit point of low voltage wiring must be secured against water entry into the box (rain tight bushing, cord grip etc.). Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 11 of 14

7. Connect the power unit to 120VAC junction box. ( see Att.7 for wiring diagram) Caution: Have a licensed electrician connect primary. Note: HRL-PS96-70 is equipped to accept 120VAC OR 240VAC. Proper connection is as follows: a) For 120VAC: Hot to Black & Yellow; Neutral/Common to Orange & White; Green: Ground b) For 240VAC: Hot to Black: Neutral/Common to Orange; White & Yellow connected and insulate ends; Green: Ground Note: HRL-PS96-70 power unit has a cutout for 1/2 conduit fitting. It is required to use UL rated metallic or nonmetallic conduit between the junction box and the power supply enclosure. Note: High voltage primary wiring, including wiring within 120VAC junction box, should comply with any applicable grounding and bonding requirements in Article 600 of the 2005 National Electrical Code (NEC). 8. Verify if disconnect switch is present. National Electrical Code (NEC) requires disconnect switch with all electrical signs. If disconnect switch is not present, it must be installed between main breaker and first power unit. Power Supplies will be used in listed signs only. Table 3: HRL-PS96-70 Power Supply Loading Guidelines Power Supply Outputs Output Voltage Minimum Linear Footage Per Terminal Maximum Linear Footage Per Terminal Total Linear Footage HRL-PS96-70 2 8.0VAC nom. 10 linear feet 35 linear feet 70 linear feet Attachment 6 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 12 of 14

Attachment 7 Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 13 of 14

Troubleshooting Issue All letters are off Some letters are off Some LEDs appear dim or intermittent Shadows/uneven lighting Solution Check circuit breaker and AC input connection. Check power supply output connections and re-settable breakers (if applicable). Check IDC connectors to ensure they are fully connected. Check power lead wire connections on strip and verify connections are secure. (See Att. 1) Measure R-Lite strip length to ensure the maximum load length has not been exceeded. Be sure each jumper has been included in the overall footage for the power supply. Properly terminate the supply wire connection(s). Check IDC connectors to ensure they are fully connected. Check power supply output connections and re-settable breakers (if applicable). Check power lead wire connections on strip and verify connections are secure. (See Att. 1) Measure R-Lite strip length to ensure the maximum load length has not been exceeded. Be sure each jumper has been included in the overall footage for the power supply. Check IDC connectors to ensure they are fully connected. Check power supply output connections and re-settable breakers (if applicable). Measure R-Lite strip length to ensure the maximum load length has not been exceeded. Make sure the Class 2 wire has not exceeded the maximum length of 25-ft for remote mounting. Make sure Class 2 wire is not higher than 12AWG. Verify the max load length has not been exceeded and that wire connections and terminations are good. Re-route connecting wire and secure with wire clamps to ensure wire does not cover any of the LEDs. Copyright 2016 Revolution Lighting. All rights reserved. IN064_01_20160907 Page 14 of 14