Axis MEDICAL GAS TERMINAL UNITS

Similar documents
Axis AGSS TERMINAL UNITS

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

PRECISION UK Ltd. Medical Gas Outlet BS Standard

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

Technical Datasheet. SP Terminal Units. Classification. Services. Terminal Block. Check Valve Assembly. Tailpipe Options

PRECISION UK Ltd DUPLEX AGSS PLANT

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Compatible

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Slim Style Compatible

Technical Specification

THERMOSTATIC CONCENTRIC DUAL CONTROL SHOWER VALVES Installation & aftercare instructions

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

3 Ton Trolley Jack. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Servicing Instructions

Pan and Tilt Head CDD2416-T

Warning. Document ref: A October 2015

Aerocourse Fan Assisted Trench Heating

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

CEGA FORANO BY GREGGERSEN

KD1E Range Potential Indicators

THERMOSTATIC INLINE CONTROL SHOWER VALVES Installation & aftercare instructions

ORIGINAL INSTRUCTIONS

(UK) Date : January 2014

Outlets and Accessories

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

OWNER S MANUAL PRODUCT CODE: BOD1907

LNG Screw Down Non-Return Valve Installation, Operation and Maintenance Manual

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

CPX DUPLEX MEDICAL VACUUM PLANT INSTALLATION, OPERATIONS & MAINTENANCE MANUAL

Navigator 550 Sodium wet-section

Operating Instructions. International English. CCS Dust Extractor

OWNER S MANUAL PRODUCT CODE: 2006T

HEAVY DUTY TROLLEY JACK. Operation Manual

INSTALLATION INSTRUCTIONS

Installation & Operation Manual

Acura TMV3 Bath Filler AC50010CP and AC50020CP

Welker Adjustable Probe with Check Valve and Welker Automatic Insertion Probe with Check Valve

1901 Thermostatic Shower Mixer

SB ISS.04. Operation Manual AGMDPRO Automatic Spray Gun

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Degas Shower Valve System 5400-X... Valve includes stops 5400-TRM... Trim only

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

SELF PRIMING CHEMICAL SERVICE PUMPS

BOLT TENSIONERS. carefully before use and retain it for reference.

SERIES G3DB/AG3DB ELEVATOR

60V RECHARGEABLE LITHIUM-ION BATTERY

HYDRAULIC BENDER VZ1536

OPERATING MANUAL C-1350 CABLE PUSHER. Copyright 2003 by CBS Products (KT), Ltd


INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR T40 Mk. 2 DISC BRAKE CALIPER M1492

Heating and Gas Installations - December 2014

VANDAL RESISTANT FITTINGS VR105, VR125, VR145 (VR106, VR115 Export only) PRODUCT MANUAL IMPORTANT

Hydraulic Immediate Need Power Pack

Model DS1000/DT20 System

SRK12KX Battery-powered Crimping Tool

12v / 24v Diesel Transfer Pump Kit

BATH FILLER & BATH / SHOWER MIXER Installation & aftercare instructions

THERAPY EQUIPMENT LTD

2200 North Main Street Washington, PA PH: FX:

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

VR2-CC VR2-RS VR2-ES PRODUCT MANUAL

Service Manual Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

SB-E ISS.05. Operation Manual AA4400A Automatic Air Assisted Airless Spray Gun

Vic-Press PFT510 TM-PFT510 WARNING SCHEDULE 10S SYSTEM PRODUCTS OPERATING AND MAINTENANCE INSTRUCTIONS MANUAL

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

TANKERS OPERATING & SAFETY INSTRUCTIONS FOR SPARE PARTS GO TO

CT-930 MANUAL HYDRAULIC COMPRESSION TOOL TABLE OF CONTENTS

Gemini, Diamond II and Diamond III Medical Gas Outlets for Concealed Piping and Console Applications

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Finishing Mower Estate 72

Instructions for INSTALLATION -- OPERATION -- MAINTENANCE of the SELAS AIR/GAS BLENDER VALVE. (for PROPANE/AIR, BUTANE/AIR AND OTHER BLENDS)

EK1240KL Battery-powered Crimping Tool

HILLSTONE DC LOAD BANK

EH Mechanical Booster Pumps

INSTALLATION INSTRUCTIONS

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

NEOTECHA NTB-NTC BALL VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

TIX402 EOS Installation and Operating Guide

Internal Pipe Cleaning Tool

Installation Operation Maintenance

Operation Manual FLG-G5 Transtech Gravity Spray Gun SB-E ISS.05

AIR PAINT SHAKER OWNER'S MANUAL

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual

PROMAX INSTRUCTION MANUAL

2 TON CAPACITY PROFESSIONAL SERIES ALUMINUM JACK OWNER'S MANUAL SPECIFICATIONS

Installation and Operation Instruction Manual FWINSMAN303. Yardney - Filtaworx FW06EX - FW10

G600 Series Replacement Intermittent Pilot Ignition Controls

Instruction Manual. XDS Dry Pump. Description Electrical Supply Item Number

FABER BURNER ROUTINE MAINTENANCE

Operating, Safety. Maintenance Manual. for. Roller Shutter & Sectional. Overhead Doors

Hydraulic PTO Flow Device

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Lynx 3:1 Pump. Model: OPERATION, INSTALLATION, MAINTENANCE AND REPAIR GUIDE

4.2 WATER PUMP (GEAR CASE MOUNTED AND LATER) (GCM)

INSTRS30709 rev 1 02/10/09 Page 1

Quickdraw. Model 2400 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Rental Industry Safety Tester Safe Check 5s

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

AP50 MANUAL AND PARTS LIST VERSA-MATIC PUMP. Service / Maintenance Log SUBMERSIBLE CENTRIFUGAL PUMP. Contact Information. Date Details Completed

Transcription:

Axis MEDICAL GAS TERMINAL UNITS Phoenix Pipeline Products Limited. Unit 8, McKenzie Industrial Park, Tel No.: 44 (0) 161 428 7200 Bird Hall Lane, Fax No.: 44 (0) 161 428 7010 Stockport, Email: info@p3-phoenix.com U.K., SK3 0SB www.p3-phoenix.com

Contents Page Section Page Product Description General 3 First Fix Assembly 3 Check Valve Assembly 3 Second Fix Assembly 3 Operation General 4 Probe Connection/Disconnection 4 Safety General 4 Installation General 4 Assembly 5 Surface Mounting 5 Flush Mounting Solid Wall 6 Flush Mounting Partition Wall 6 Bedhead Mounting Standard 6 Bedhead Mounting Rear Entry 7 Bedhead Mounting 90 0 Left Hand 7 Bedhead Mounting 90 0 Right Hand 7 Pendant Mounting 8 Testing General 9 First Fix Testing 9 Second Fix Testing 9 Commissioning 9 Maintenance General 9 Preventative Maintenance 10 First Fix Assembly 10 Check Valve Assembly 11 Spare Parts Lists General Components 12 Gas Specific Components 12-2 - Axis Medical Gas Terminal Units Rev 3

1. Product Description 1.1 General Axis Terminal Units comprise a first fix, second fix and check valve. The first fix assembly includes a copper pipe for brazing to the fixed pipeline system, a NIST connector for connection to a hose assembly or a permanently crimped hose assembly. Terminal units are available for oxygen, nitrous oxide, 50% oxygen/50% nitrous oxide mixture, medical air, surgical air and medical vacuum. Terminal units are available for wall mounting (flush or surface), bedhead trunking and pendant mounting. 1.2 First Fix Assembly The first fix assembly comprises of a machined brass block which is mounted in a die cast housing. The unit is indexed for each different gas service to prevent interchangeability. The unit incorporates a maintenance valve which will automatically shut off the gas supply if the second fix assembly is removed whilst the pipeline system is under pressure. 1.3 Check Valve Assembly The check valve assembly comprises of a spring loaded valve housed in a machined brass body. The check valve permits the gas to flow when a probe is connected and seals off the gas flow when the probe is disconnected. The unit is installed between the first fix and the second fix. 1.4 Second Fix Assembly The second fix assembly comprises of a gas specific body which accepts, retains and releases the probe. The base of the body is indexed to match the first fix assembly. The front face of the second fix assembly incorporates a colour coded gas identity label. The unit will only accept the probe for the appropriate service. - 3 - Axis Medical Gas Terminal Units Rev 3

2. Operation 2.1 General Each terminal unit is gas specific and will only accept the appropriate BS probe ensuring that a probe for one service cannot be inserted into a terminal unit for another service. It is important that only probes conforming to BS 5682 are used. The probe should be inserted so that the cutout in the indexing collar is uppermost. This cut-out aligns with an anti-swivel pin incorporated into the second fix assembly which prevents the probe from rotating. This ensures that equipment such as flowmeters remain vertical when plugged directly into the terminal unit. 2.2 Probe Connection/Disconnection 3. Safety To connect, the appropriate probe is pushed firmly into the second fix until it engages. This action opens the check valve and allows gas to flow. To disconnect, the probe should be held and the front of the second fix pushed forward. This action releases the probe. When the probe is removed, the check valve closes providing a gas tight seal. 3.1 General This equipment should be installed, operated and maintained by personnel who are suitably trained, are fully conversant with HTM 2022/HTM 02 & BS EN 737 and are familiar with this product. This equipment should be kept clean and be free from oil and grease at all times. Oil and grease will ignite spontaneously in the presence of Oxygen. If you suspect that any equipment is contaminated, do not use it. No attempt should be made to use or modify this equipment for use with a gas other than as identified. This equipment should not be operated at pressures exceeding those stated in HTM 2022/HTM 02 and BS EN 737. DO NOT USE CLEANING/DETECTION FLUIDS WHICH CONTAIN COCONUT DIETHANOLAMIDE AS THIS IS HARMFUL TO ENGINEERING POLYMERS SEALS AND METAL PARTS. 4. Installation 4.1 General Terminal units should be mounted at a height of between 900mm and 1400mm above finished floor level and be not less than 200mm from any obstruction. Where more than one terminal unit is to be mounted in one location, these should be mounted at the following spacing; Two terminal units - 150mm centres. Three or more terminal units - 135mm centres. Terminal units mounted in a horizontal array shall be installed in the following sequence when viewed from the front, left to right; O2; N2O; 50% O2/50% N2O; Medical Air; Surgical Air; Vacuum; AGSS - 4 - Axis Medical Gas Terminal Units Rev 3

4.2 Assembly 1. Determine the required position of the terminal unit and secure the first fix assembly and wall mounting box, if required, using suitable fixings ensuring that the assembly is horizontal and plumb. 2. Braze the copper stub pipe to the fixed pipeline system. If the joint to be brazed is close to the brass block, remove the internal components prior to the brazing operation. 3. Fit the first fix test plug into the first fix assembly and pressure test the pipeline system. 4. Upon satisfactory completion of the pressure test, fit a plaster shield if required. 5. When the wall is finished, remove the plaster shield if fitted, remove the test plug and fit the check valve assembly and second fix assembly. 6. Fit the fascia and flush surround if required, pressure test and purge the pipeline system. 7. Check the anti swivel pin is at the top, reposition if necessary using a 1/16 Allen key. 8. Remove the anti-swivel pin if this is not required, using a 1/16 Allen key. 9. Fit Danger Do Not Use label as required. 4.3 Surface Mounting - 5 - Axis Medical Gas Terminal Units Rev 3

4.4 Flush Mounting Solid Walls 4.5 Flush Mounting Partition Walls 4.6 Bedhead Mounting - Standard - 6 - Axis Medical Gas Terminal Units Rev 3

4.7 Bedhead Mounting Rear Entry 4.8 Bedhead Mounting 90 0 Left Hand 4.9 Bedhead Mounting 90 0 Right Hand - 7 - Axis Medical Gas Terminal Units Rev 3

4.10 Pendant Mounting Rear Entry Nist Nut & Nipple 4.11 Pendant Mounting Rear Entry Barb Type 4.12 Pendant Mounting Rear Entry 90 0 NIST Nut & Nipple - 8 - Axis Medical Gas Terminal Units Rev 3

5. Testing 5.1 General All terminal units should be pressure tested once incorporated into the fixed pipeline system. The testing is split into two phases as detailed below. The second phase of testing can only be carried out when the first phase has been deemed satisfactory and accepted. 5.2 First Fix Testing This pressure test is carried out when the first fix installation has been completed. The required testing pressures are as stated below or as per the contract specification if different. First fix testing pressures in accordance with HTM 2022/HTM 02 are; (a) 10 barg. for compressed medical gas systems. (b) 18 barg. for compressed surgical gas systems. (c) 7 barg. for vacuum systems. First fix pressure tests in accordance with BS EN 737-3 are 1.5 times nominal distribution pressure for compressed gas systems and 500 kpa for vacuum systems. 5.3 Second Fix Testing This pressure test is carried out upon completion of the second (final) fix installation with the system pressurised to nominal distribution pressure in accordance with HTM 2022/HTM 02 and BS EN 737. 5.4 Commissioning The terminal unit must not be used until all testing & commissioning procedures for the pipeline system as detailed in HTM 2022/HTM 02 and/or BS EN 737-3 have been satisfactorily completed and accepted. 6. Maintenance 6.1 General The only maintenance required is to replace parts that will become worn during normal usage, however the use of damaged probes or faulty equipment may require further maintenance to be undertaken. The first fix assembly and check valve assembly incorporate o rings that will require replacing periodically. The second fix assembly is maintenance free and should be replaced if damaged. The maintenance valve in the first fix assembly is designed to prevent the flow of gas during short periods of maintenance. If a second fix assembly is to be removed for a long period, it is recommended that alternative arrangements are made for a more secure seal. Should the external surfaces of the terminal unit require cleaning, we recommend that this is carried out using a damp cloth along with a mild soap solution if required. Do not use abrasive or solvent based cleaning solutions. Do not let any liquid enter the terminal unit. DO NOT USE CLEANING/DETECTION FLUIDS WHICH CONTAIN COCONUT DIETHANOLAMIDE AS THIS IS HARMFUL TO ENGINEERING POLYMERS SEALS AND METAL PARTS. - 9 - Axis Medical Gas Terminal Units Rev 3

6.2 Preventative Maintenance Regular inspections and maintenance of the terminal unit will prolong it s life and reduce the possibility of sudden, inconvenient component failures. Terminal units should be subjected to regular inspection and testing as detailed below. Monthly; (a) Visually inspect the terminal unit for signs of damage. (b) Check the second fix assembly operates freely. (c) Any reluctance in the operation of the second fix should result in the removal of the unit for closer inspection/repair/replacement as necessary. Annually; (a) Remove fascia and clean any debris from the mounting box. (b) Remove second fix assembly and replace the first fix o rings. (c) Remove second fix assembly and replace check valve assembly. (d) Test second fix for correct operation (connection and disconnection of probe) using a blank probe. 6.3 First Fix Assembly To replace the o rings in the first fix assembly; 1. Isolate the gas supply to the terminal unit via the AVSU or line valve. 2. Undo the two screws and remove the fascia and flush surround if applicable. 3. Undo the two Allen head screws that secure the second fix assembly to the first fix assembly. 4. Remove the second fix assembly and check valve assembly and place to one side. 5. Remove the o rings from inside the brass block taking care not to damage the grooves. 6. Fit new o rings into the grooves after checking that the maintenance valve is in place and the right way round. - 10 - Axis Medical Gas Terminal Units Rev 3

Note: There is no maintenance valve in vacuum terminal units. 7. Place the check valve assembly and second fix assembly in position. Fully tighten the two Allen head screws, alternating between the two, screwing them in a few turns at a time. 8. Turn on the gas supply and check for leaks. 9. Re-fit the fascia and flush surround if applicable. 6.4 Check Valve Assembly To replace the check valve assembly; 1. Undo the two Allen head screws that secure the second fix assembly to the first fix assembly. 2. Remove the second fix assembly and check valve assembly. 3. Discard the check valve assembly and place the second fix assembly to one side. Note: The maintenance valve will restrict the gas flow. On vacuum terminal units, place a blank disc over the inlet if the system is under vacuum, or quickly install the new check valve. 4. Insert a new replacement check valve assembly into the first fix block and re-fit the second fix assembly. Fully tighten the two Allen head screws, alternating between the two, screwing them in a few turns at a time. 5. Test second fix for correct operation (connection and disconnection of probe) using a blank probe. 6. Turn on the gas supply and check for leaks. 7. Spare Parts Lists When ordering spare parts, please use the following component descriptions and part numbers to ensure that you receive the component that you require! 7.1 General Components Description Part Number First Fix Assembly Refer to 7.2 Second Fix Assembly Refer to 7.2 Mounting Box 1-09101-09 Mounting Box Cover 1-09102-09 Mounting Box Flush Plate 1-09103-09 Check Valve Assembly 1-09090-09 Maintenance Valve 1-09105-09 First Fix O Ring 1-09106-09 First Fix Test Plug 1-09104-09-11 - Axis Medical Gas Terminal Units Rev 3

7.2 Gas Specific Components Description Part Number Flush TU First Fix Assy, 12mm, Oxygen 1-09010-01 Flush TU First Fix Assy, 12mm, N2O 1-09011-02 Flush TU First Fix Assy, 12mm, O2/N2O 1-09012-03 Flush TU First Fix Assy, 12mm, MA4 1-09013-04 Flush TU First Fix Assy, 12mm, SA7 1-09014-05 Flush TU First Fix Assy, 12mm, Vacuum 1-09015-06 Flush TU First Fix Assy, 2 metre 15mm stub pipe, O2 1-09200-01 Flush TU First Fix Assy, 2 metre 15mm stub pipe, N2O 1-09201-02 Flush TU First Fix Assy, 2 metre 15mm stub pipe, O2/N2O 1-09202-03 Flush TU First Fix Assy, 2 metre 15mm stub pipe, MA4 1-09203-04 Flush TU First Fix Assy, 2 metre 15mm stub pipe, SA7 1-09204-05 Flush TU First Fix Assy, 2 metre 15mm stub pipe, Vacuum 1-09205-06 Bedhead TU First Fix Assy, 12mm, Oxygen 1-09030-01 Bedhead TU First Fix Assy, 12mm, N2O 1-09031-02 Bedhead TU First Fix Assy, 12mm, O2/N2O 1-09032-03 Bedhead TU First Fix Assy, 12mm, MA4 1-09033-04 Bedhead TU First Fix Assy, 12mm, SA7 1-09034-05 Bedhead TU First Fix Assy, 12mm, Vacuum 1-09035-06 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, O2 1-09260-01 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, N2O 1-09261-02 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, O2/N2O 1-09262-03 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, MA4 1-09263-04 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, SA7 1-09264-05 Bedhead TU First Fix Assy, 2 metre 15mm stub pipe, Vacuum 1-09265-06 LH Bedhead TU First Fix Assy, 12mm, Oxygen 1-09220-01 LH Bedhead TU First Fix Assy, 12mm, N2O 1-09221-02 LH Bedhead TU First Fix Assy, 12mm, O2/N2O 1-09222-03 LH Bedhead TU First Fix Assy, 12mm, MA4 1-09223-04 LH Bedhead TU First Fix Assy, 12mm, SA7 1-09224-05 LH Bedhead TU First Fix Assy, 12mm, Vacuum 1-09225-06-12 - Axis Medical Gas Terminal Units Rev 3

7.2 Gas Specific Components (continued) Description Part Number RH Bedhead TU First Fix Assy, 12mm, Oxygen 1-09240-01 RH Bedhead TU First Fix Assy, 12mm, N2O 1-09241-02 RH Bedhead TU First Fix Assy, 12mm, O2/N2O 1-09242-03 RH Bedhead TU First Fix Assy, 12mm, MA4 1-09243-04 RH Bedhead TU First Fix Assy, 12mm, SA7 1-09244-05 RH Bedhead TU First Fix Assy, 12mm, Vacuum 1-09245-06 Rear-entry Bedhead TU First Fix Assy, 15mm, Oxygen 1-09060-01 Rear-entry Bedhead TU First Fix Assy, 15mm, N2O 1-09061-02 Rear-entry Bedhead TU First Fix Assy, 15mm, O2/N2O 1-09062-03 Rear-entry Bedhead TU First Fix Assy, 15mm, MA4 1-09063-04 Rear-entry Bedhead TU First Fix Assy, 15mm, SA7 1-09064-05 Rear-entry Bedhead TU First Fix Assy, 15mm, Vacuum 1-09065-06 Rear-entry Bedhead TU First Fix Assy, 15mm, AGSS 1-09066-07 Rear-entry Bedhead TU First Fix Assy, 12mm, Oxygen 1-09300-01 Rear-entry Bedhead TU First Fix Assy, 12mm, N2O 1-09301-02 Rear-entry Bedhead TU First Fix Assy, 12mm, O2/N2O 1-09302-03 Rear-entry Bedhead TU First Fix Assy, 12mm, MA4 1-09303-04 Rear-entry Bedhead TU First Fix Assy, 12mm, SA7 1-09304-05 Rear-entry Bedhead TU First Fix Assy, 12mm, Vacuum 1-09305-06 Pendant TU First Fix Assy, Rear-entry NIST, Oxygen 1-09040-01 Pendant TU First Fix Assy, Rear-entry NIST, N2O 1-09041-02 Pendant TU First Fix Assy, Rear-entry NIST, O2/N2O 1-09042-03 Pendant TU First Fix Assy, Rear-entry NIST, MA4 1-09043-04 Pendant TU First Fix Assy, Rear-entry NIST, SA7 1-09044-05 Pendant TU First Fix Assy, Rear-entry NIST, Vacuum 1-09045-06 Pendant TU First Fix Assy, 90 Rear-entry NIST, Oxygen 1-09280-01 Pendant TU First Fix Assy, 90 Rear-entry NIST, N2O 1-09281-02 Pendant TU First Fix Assy, 90 Rear-entry NIST, O2/N2O 1-09282-03 Pendant TU First Fix Assy, 90 Rear-entry NIST, MA4 1-09283-04 Pendant TU First Fix Assy, 90 Rear-entry NIST, SA7 1-09284-05 Pendant TU First Fix Assy, 90 Rear-entry NIST, Vacuum 1-09285-06-13 - Axis Medical Gas Terminal Units Rev 3

7.2 Gas Specific Components (continued) Description Part Number Pendant TU First Fix Assy, Rear-entry hose barb, Oxygen 1-09050-01 Pendant TU First Fix Assy, Rear-entry hose barb, N2O 1-09051-02 Pendant TU First Fix Assy, Rear-entry hose barb, O2/N2O 1-09052-03 Pendant TU First Fix Assy, Rear-entry hose barb, MA4 1-09053-04 Pendant TU First Fix Assy, Rear-entry hose barb, SA7 1-09054-05 Pendant TU First Fix Assy, Rear-entry hose barb, Vacuum 1-09055-06 Surface/Flush TU First Fix Assy, Top-entry NIST, Oxygen 1-09070-01 Surface/Flush TU First Fix Assy, Top-entry NIST, N2O 1-09071-02 Surface/Flush TU First Fix Assy, Top-entry NIST, O2/N2O 1-09072-03 Surface/Flush TU First Fix Assy, Top-entry NIST, MA4 1-09073-04 Surface/Flush TU First Fix Assy, Top-entry NIST, SA7 1-09074-05 Surface/Flush TU First Fix Assy, Top-entry NIST, Vacuum 1-09075-06 TU Second Fix Assy, Oxygen 1-09080-01 TU Second Fix Assy, N2O 1-09081-02 TU Second Fix Assy, O2/N2O 1-09082-03 TU Second Fix Assy, MA4 1-09083-04 TU Second Fix Assy, SA7 1-09084-05 TU Second Fix Assy, Vacuum 1-09085-06 Due to our policy of continuous product improvement, Phoenix Pipeline Products Ltd. reserve the right to alter dimensions and/or specification without notice although every effort will be made to advise of any such modifications. Certain aspects of P³ Ltd. designs are protected. - 14 - Axis Medical Gas Terminal Units Rev 3